Madhya Pradesh Power Generating Company Limited Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Madhya Pradesh Power Generating Company Limited - MPPGCL Tender

Works
Machinery and Tools
Eprocure
Opening Date17 Jan 2020
Closing Date24 Mar 2020
Tender Amount₹ 4,45,00,000 
Notes
Download

Costs

  • EMD

    ₹ 4,45,000
  • Document Cost

    ₹ 5,000
  • Tender Fee

    ₹ 1,534

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Pent House (During AOH)

4

-

-

... More
Pent House (During Preventive / Break Down Maintenance)

12

-

-

... More
Dead Chamber (During AOH)

4

-

-

... More
Dead Chamber (During Preventive / Break Down Maintenance)

4

-

-

... More
Economizer Hoppers with Connecting Ducts (During AOH)

4

-

-

... More
Economizer Hoppers with Connecting Ducts (During Preventive / Break Down Maintenance)

16

-

-

... More
Bottom Ash Hoppers

4

-

-

... More
Cleaning of Entire Second Pass Coils / Tubes

5

-

-

... More
Hydrojet Cleaning of Coils & Tubes

-

-

-

... More
Cleaning of Final Super Heater Coils

5

-

-

... More
Cleaning of Platen Super Heater Coils

5

-

-

... More
Cleaning of Pendent Re-heater Coils

5

-

-

... More
Cleaning of Water Wall Tubes

5000

-

-

... More
SCAFFOLDING

-

-

-

... More
Re-heater / Final / Platen Super Heater (from Goose Neck to Roof)

4

-

-

... More
Furnace (From Bottom Ash Hopper to Goose Neck)

-

-

-

... More
a) Convection Method

4

-

-

... More
b) Cup-lox Method (Entire Boiler 1st & 2nd Pass)

2

-

-

... More
Preparation of Scaffolding above Goose Neck for Inspection of Pendent Re-heater Final / Platen Super Heater (During Preventive / Break Down Maintenance)

12

-

-

... More
HP Joints in Boiler Tubes

-

-

-

... More
Economiser

3500

-

-

... More
Primary Super Heater / Baffle Tubes

650

-

-

... More
Final & Platen Super Heater

290

-

-

... More
Water Wall

210

-

-

... More
Horizontal Re-heater (100% radiography)

1100

-

-

... More
Pendant Re-heater (100% radiography)

670

-

-

... More
Slings (Riser Tubes)

40

-

-

... More
Bleed Tubes

110

-

-

... More
Stringer Tubes

75

-

-

... More
Cage Tubes

150

-

-

... More
Hydra Step

60

-

-

... More
Drains

300

-

-

... More
Vents

300

-

-

... More
Instrument Piping

240

-

-

... More
Reinforcement of Welding Joints

-

-

-

... More
Economiser / Bleed

2910

-

-

... More
Re-heater / Water Wall

530

-

-

... More
Slings / Riser

250

-

-

... More
Drum Vent

30

-

-

... More
B

-

-

-

... More
Assistance in Non-destructive Test (During AOH)

4

-

-

... More
Assistance in Thickness Survey & Radiography (During Preventive / Break Down Maintenance)

13

-

-

... More
Alignment of Economizer / Super Heater / Re-heater Coils

1500

-

-

... More
Welding on Eroded Tubes

-

-

-

... More
a) Size 50x50 sqmm

4100

-

-

... More
Welding of Fins

1200

-

-

... More
Header Inspection & Flashing / Inspection of Spray Nozzle Attemperator

48

-

-

... More
Bend Fabrication

210

-

-

... More
Fabrication & Fixing of Erosion Shield / Casstte Baffle

-

-

-

... More
Fabrication & Fixing

1400

-

-

... More
Fixing Only

11600

-

-

... More
Fabriction / repairing / fixing of Cassette Baffle in Economizer, Primary Super Heater, Horizontal Re-heater

1050

-

-

... More
H.P.Valves

-

-

-

... More
Root Valves (Upto 25 mm)

-

-

-

... More
a) Replacement

90

-

-

... More
b) Repair / Servicing

180

-

-

... More
c) Gland Packing

260

-

-

... More
Above 25 mm to 100 mm

-

-

-

... More
a) Replacement

70

-

-

... More
b) Repair / Servicing

260

-

-

... More
c) Gland Packing

430

-

-

... More
Above 100 mm

-

-

-

... More
a) Replacement

21

-

-

... More
b) Repair / Servicing

65

-

-

... More
c) Gland Packing

96

-

-

... More
Boiler Safety Valves

-

-

-

... More
a) Repair / Servicing

48

-

-

... More
Feed Regulating Valve with Actuator

-

-

-

... More
a) Repair / Servicing

23

-

-

... More
NRV

11

-

-

... More
Boiler Drum Cleaning & Repairing with Associated Piping

4

-

-

... More
Repairing of Pent House and Internals

3

-

-

... More
Replacement of Pent House Boxses

-

-

-

... More
a) With Steel

26

-

-

... More
b) With out Steel

2200

-

-

... More
Repairing of Dead Chamber

-

-

-

... More
a) With Steel

12

-

-

... More
b) With out Steel

1000

-

-

... More
Repairing of Economiser Hoppers & Connection Joint Ducting & Making / Strenghten of their Platform

4

-

-

... More
Repairing of Economiser Casing

2

-

-

... More
Repairing of Bottom Ash Hopper Liner & Seal Trough Including Fixing of Dipper Plate

4

-

-

... More
Repairing of Furnace Zone & Rest of the Areas

-

-

-

... More
a) With Steel

8

-

-

... More
b) With out Steel

1000

-

-

... More
Repairing of Second pass casing

-

-

-

... More
a) With Steel

30

-

-

... More
b) With out Steel

1800

-

-

... More
Replacement / Strengthening of Baffle Plate between PSH & Re-heater

-

-

-

... More
a) With Steel

15

-

-

... More
b) With out Steel

900

-

-

... More
Repairing of Cat House

-

-

-

... More
a) With Steel

6

-

-

... More
b) With out Steel

550

-

-

... More
Repairing & Servicing

-

-

-

... More
a) Buckstays

220

-

-

... More
b) Diamond Type Locks

220

-

-

... More
c) Rockers

220

-

-

... More
Servicing of Hangers and Supports

220

-

-

... More
Application of Refractory Grade “A”

23

-

-

... More
Application of Refractory Grade-“C”

-

-

-

... More
a) Penthouse

36

-

-

... More
b) Dead Chamber & Screen Wall

28

-

-

... More
c) Other Areas like BAH/Hoppers/Headers etc.

33

-

-

... More
Assistance in Hydraulic Test.

4

-

-

... More
Installation of MITP

35

-

-

... More
Servicing / Repairing of Drum Sampling Cooler

14

-

-

... More
Repairing of Furnace Man Hole / Peep Hole / View Window

55

-

-

... More
Application of Thermal Insulation at Boiler and Associated Auxiliaries

-

-

-

... More
Complete Bolier from Bottom Ash Hopper to Penthouse

2300

-

-

... More
Steam and Water Piping

1500

-

-

... More
Boiler Drum and Piping

250

-

-

... More
Wind Box

1500

-

-

... More
Air and Flue Gas Ducting upto Chimney

1700

-

-

... More
ID/FD/PA Fan Ducting

1300

-

-

... More
ESP

1900

-

-

... More
Coal Mill and Fuel Pipings

250

-

-

... More
Painting of Boiler Base Structure

12000

-

-

... More
Repairing of Re- heater & PSH Aero Dynamic Damper inclding Top / Bottom and Near by Area

2

-

-

... More
Removal of Thermal Insulation of Boiler and Associated Auxiliaries

8400

-

-

... More
Disposal of Rubbish Thermal Insulation

2

-

-

... More
Removal of Erosion Shield

10000

-

-

... More
WIND BOX

-

-

-

... More
Cleaning of Wind Box & Ash Transportation

4

-

-

... More
Repairing of Wind Box

-

-

-

... More
a) With Steel

26

-

-

... More
b) With out Steel

1400

-

-

... More
Repairing of Wind Box roof

-

-

-

... More
a) With Steel

15

-

-

... More
b) With out Steel

900

-

-

... More
AIR RESISTERS

-

-

-

... More
Servicing of Air Resisters in position (Major)

40

-

-

... More
Making Air registers operative (Minor)

28

-

-

... More
Replacement of Air Resisters

4

-

-

... More
Repairing of Core Tube

18

-

-

... More
Replacement of Core Tube

61

-

-

... More
COAL BURNERS

-

-

-

... More
Servicing of PF Burners (During AOH) (PH-I)

24

-

-

... More
Repairing of PF Burner Assembly (During Preventive / Break Down Maintenance)

24

-

-

... More
Servicing of PF Nozzle (PH-I)

9

-

-

... More
Servicing of PF Burners (PH-II)

22

-

-

... More
Replacement of PF Burners Assembly (PH-I)

24

-

-

... More
Replacement of PF Nozzle

39

-

-

... More
Replacement of PF Burners Assembly (PH-II)

12

-

-

... More
Refractory

3

-

-

... More
Repair/Replacement of Liners of Banjo

25

-

-

... More
FUEL OIL CIRCUIT

-

-

-

... More
Servicing of Complete Oil Burner Assembly

96

-

-

... More
Re-visioning of isolating and control valve

-

-

-

... More
HFO Isolating V/v Glove 25 mm

77

-

-

... More
LDO Isolating V/v Glove 20 mm

77

-

-

... More
Attomisation Steam V/v Glove 15 mm

77

-

-

... More
NRV's Glove 25 mm

87

-

-

... More
Control Valve Glove 25 mm

87

-

-

... More
HFO Control / Shut off Valve 50 mm

16

-

-

... More
LDO Control /Shut off Valve 50 mm

16

-

-

... More
HFO /LDO Isolating Valve 50mm

101

-

-

... More
Heating Line Drain / Trapes Glove V/v 25 mm

107

-

-

... More
SERVICING OF HFO /LDO PRES. SYSTEM

-

-

-

... More
Serv. of HFO COMP. Press. Sys. Pumps, Filter

10

-

-

... More
Heaters

8

-

-

... More
Serv. of LDO COMP. Press. Sys. Pumps, Filter

7

-

-

... More
Servicing / Replacement of Valves

-

-

-

... More
a. Up to 50 mm

66

-

-

... More
b. Above 50 mm

33

-

-

... More
HFO / LDO Unloading System

-

-

-

... More
Servicing of Basket Filter.

18

-

-

... More
Serv. of Newly Installed HFO / LDO COMP. Unloading Sys. Pumps from Tankers, Heaters

4

-

-

... More
Cleaning and Disposal of Fly Ash / Coarse Ash Debris upto the suitable place i.e. Ash Dyke etc. (During Preventive / Break Down Maintenance)

1500

-

-

... More
Assistant in Safety Valve Setting

4

-

-

... More
Initial Mobilization Charges during Tube Leakage Attending

12

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.