Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Madhya Pradesh Power Generating Company Limited - MPPGCL Tender
Energy, Oil and Gas
Eprocure
Opening Date10 Dec 2024
Closing Date6 Jan 2025
Tender Amount₹ 3,16,20,000
Costs
EMD
₹ 3,16,200Document Cost
₹ 5,000Tender Fee
₹ 1,534
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MPPGC_375619_1Tender No
WT-2474Tender Authority
Madhya Pradesh Power Generating Company Limited ViewPurchaser Address
-Website
http://http://www.mppgcl.mp.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Cleaning of Ash in Dead Chamber, Penthouse, Cat House
4
-
-
... More
PREPARATION OF SCAFFOLDING
-
-
-
... More
Preparation of Scaffolding in Boiler Horizontal Pass ( Including Goosneck Part, Screen Tubes , TT Coil , Reheater Coils)
16
-
-
... More
Preparation of scaffolding above Economiser Hopper for inspection & attending of Economiser Lower Bank Coil
4
-
-
... More
Preparation of Scaffolding in Wind Box at Each Corner
8
-
-
... More
Preparation of Scaffolding in Cat House for S-Panel Back Side Checking, Reparing
16
-
-
... More
Preparation of Scaffolding in Bottom Ash Hopper Area
4
-
-
... More
Preparation & Operation of Skyclimber in Furnace
4
-
-
... More
INSPECTION
-
-
-
... More
Inspection and repairs of doors/windows & peep holes of Boiler
20
-
-
... More
SERVICING OF SECONDARY AIR DAMPERS
320
-
-
... More
DP Test
2000
-
-
... More
Assistance in Non-Destructive Testing (NDT) such as Radiography, Tube Thickness Survey, Oxide Scale Measurement etc.
4
-
-
... More
CLEANING & REPAIR OF WIND BOX
-
-
-
... More
Repair of Windbox by patching
200
-
-
... More
Dismanteling of Steel Structures/Installation of new steel plate
2
-
-
... More
Rectification, Replacement & Refixing of protection sleeve (shielding) in various areas of Boiler tubes
1000
-
-
... More
Rectification, Replacement & Refixing of Cassette Baffles Over Boiler tubes
80
-
-
... More
WELDING OF HP JOINTS OF BOILER TUBES
-
-
-
... More
Replacement of W/W burner panel tubes
20
-
-
... More
Waterwall tubes, Screen tubes, Hanger tubes, Rear arch tubes, Steam Cooled Tubes etc.
400
-
-
... More
Economiser tubes/ LTSH tubes/Steam Cooled Tubes Below Economiser Bank area
400
-
-
... More
Platen Superheater tubes
60
-
-
... More
Divisional Superheater tubes
60
-
-
... More
Economiser Support tubes
80
-
-
... More
LTSH Support tubes
80
-
-
... More
Superheater Steam cooled spacer tubes
80
-
-
... More
Reheater (Front Assembly) tubes
80
-
-
... More
Reheater (Rear Assembly) tubes
80
-
-
... More
Reheater cross over tubes
20
-
-
... More
Reheater Steam cooled spacer tubes.
20
-
-
... More
Lower/Upper corner transition tubes
20
-
-
... More
Roof tubes
20
-
-
... More
Hydrastep
4
-
-
... More
Welding & Replacement of Drain & Vent Joints
40
-
-
... More
Welding of Fins
600
-
-
... More
Re- enforcement of Welding Joints
600
-
-
... More
Pad Welding of Thinned tubes (50mm to 150mm)
1000
-
-
... More
ALIGNMENT OF COILS/TUBES/BLOWERS
-
-
-
... More
Alignment of Coils of SH Divisional Panel
20
-
-
... More
Alignment of tubes of Platen Superheater
10
-
-
... More
Algnment of Coil of Reheater (Front/Rear)
40
-
-
... More
Alignment of Coil of Economiser tubes ( Upper/Middle/Lower)
60
-
-
... More
Alignment of LTSH coils ( Upper/Middle/Lower)
60
-
-
... More
Checking and Rectification of Expansion Indicator in Boiler Area
20
-
-
... More
Assistance in Hydraulic Test & Preparation of Boiler Light Up
8
-
-
... More
Assistance in Safety Valve Setting
4
-
-
... More
APPLICATION OF REFRACTORY AT VARIOUS LOCATION OF BOILER
-
-
-
... More
Pent house,Dead Chamber, Rear Arch, Door & Windows Etc. Grade 'C'
8
-
-
... More
Coal Burner, Soot Blower Area , Peep Holes Grade 'A'
8
-
-
... More
Removal /Breaking of Damaged Refractory & Transportation
10
-
-
... More
GLAND PACKING OF HP/LP VALVES
-
-
-
... More
Up to 25.0 mm
50
-
-
... More
25 mm to 50 mm
60
-
-
... More
50 mm to 100 mm
50
-
-
... More
100 mm to 200 mm
40
-
-
... More
Above 200 mm
20
-
-
... More
COMPLETE SERVICING OF HP/LP VALVES (EXCLUDING ACTUATORS)
-
-
-
... More
Up to 25.0 mm
50
-
-
... More
25 mm to 50 mm
60
-
-
... More
50 mm to 100 mm
50
-
-
... More
100 mm to 200 mm
40
-
-
... More
Above 200 mm
20
-
-
... More
REPLACEMENT OF HP/LP VALVES (WELDED TYPE)
-
-
-
... More
Up to 25.0 mm
60
-
-
... More
25 mm to 50 mm
40
-
-
... More
50 mm to 100 mm
20
-
-
... More
100 mm to 200 mm
10
-
-
... More
ASSISTANCE IN REMOVAL/INSTALLATION OF ACTUATORS OF HP/LP VALVES
40
-
-
... More
SERVICING OF MAIN STEAM STOP VALVE
4
-
-
... More
COMPLETE SERVICING OF SPRING LOADED SAFETY VALVES /ERV
-
-
-
... More
Boiler Drum
12
-
-
... More
Main Steam line/ CRH LINE/HRH LINE/SOOT BLOWER LINE Safety Valve
10
-
-
... More
Electromatic Relief Valve and Pilot Valve
6
-
-
... More
Cleaning /Repairing of Safety Valve Drain Tray & Line
10
-
-
... More
Peparation of HP tube bends
100
-
-
... More
Repair & Refixing of seal platesof water wall S-Panel at Trough seal
24
-
-
... More
REPAIR OF PENT HOUSE
-
-
-
... More
Repair of Pent House by patching
200
-
-
... More
Dismanteling of Steel Structures/Installation of new steel plate
2
-
-
... More
REPAIR OF DEAD CHAMBER
-
-
-
... More
Repair of Dead Chamber by patching
300
-
-
... More
Dismanteling of Steel Structures/Installation of new steel plate
2
-
-
... More
REPAIR & SERVICING
-
-
-
... More
BUCKSTAYS
20
-
-
... More
DIAMOND TYPE LOCKS
20
-
-
... More
ROCKERS
20
-
-
... More
DISMANTELING , INSTALLATION, FEBRICATION OF STRUCTURE & MISC. WORK I.E. CANOPY, BROKEN STAIR/RAILING/DRAIN
10
-
-
... More
REPAIR OF CAT HOUSE
-
-
-
... More
Repair of Cat House by patching
200
-
-
... More
Dismanteling of Steel Structures/Installation of new steel plate
2
-
-
... More
SERVICING, CLEANING & REPAIRING OF SAMPLING LINE COOLERS
10
-
-
... More
SERVICING & REPAIRING OF HANGERS & SUPPORTS
60
-
-
... More
Safety Valve setting ( Tightining/Loosening)
12
-
-
... More
Assistance for Pressure setting of steam of Wall Blower/LRSB
4
-
-
... More
Repair/Refixing/fixing of SS Wire Mesh inside Bottom Ash Hopper
200
-
-
... More
FIXING OF CORRUGATED GI SHEET AT BOILER ROOF & OTHER PLACES
1000
-
-
... More
PAINTING OF BOILER BASE STRUCTURE & ASSOCIATED AUXILIRIES
4000
-
-
... More
Fabrication & Erection Work of Platform & Approach ( As & where required in Boiler)
20
-
-
... More
IDLING CHARGES.
24
-
-
... More
Routine maintenance of Boiler Pressure Parts & Fuel Oil Handling System (FOHS) for Boiler Unit# 1 &2, 2x600 MW SSTPP: MPPGCL, Dongalia.
Note: - Quoted amount should meet the Minimum Workable criteria i.e., should not be lower than Rs. 6,13,852.38 per month else offer shall be rejected.
24
-
-