Madhya Pradesh Power Generating Company Limited Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Madhya Pradesh Power Generating Company Limited - MPPGCL Tender

Works
Machinery and Tools
Eprocure
Opening Date7 Mar 2024
Closing Date27 May 2024
Tender Amount₹ 6,84,81,600 
Notes
Download

Costs

  • EMD

    ₹ 6,84,900
  • Document Cost

    ₹ 5,000
  • Tender Fee

    ₹ 1,534

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
eNIT Document. Please note that the NIT bearing tender ID 2023_MPPGC_ 318332_2 shall be applicable for instant tendering process
Price bid/BoQ/Financial Bid
Tender Schedule, Specifications and Scope of Work along with other terms and conditions
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
CLEANING OF ASH FROM ECONOMISER HOPPER WITH CONNECTING DUCTS

2

-

-

... More
CLEANING OF PENT HOUSE, CAT HOUSE, DEAD CHAMBER

2

-

-

... More
BOTTOM ASH HOPPER CLEANING

2

-

-

... More
PREPARATION OF SCAFFOLDING

-

-

-

... More
PREPARATION OF SCAFFOLDING ABOVE ECONOMISER HOPPER FOR INSPECTION OF ECONOMISER COILS

2

-

-

... More
PREPARATION OF QUICK ERECT SCAFFOLDING SYSTEM (CUP-LOCK SYSTEM) IN BOILER FURNACE (FROM TOP TO BOTTOM) along with providing cup-lock system by firm

2

-

-

... More
PREPARATION OF SCAFFOLDING IN BOTTOM ASH HOPPER

2

-

-

... More
INSPECTION

-

-

-

... More
INSPECTION OF COMPLTE BOILER PRESSURE PARTS (IST & IIND PASS)

2

-

-

... More
INSPECTION & REPAIR OF ALL DOORS ,WINDOWS AND PEEP HOLES IN BOILER

50

-

-

... More
HEADER INSPECTION & INSPACTION OF SPRAY NOZZLE ATTEMPERATOR

20

-

-

... More
INTERNAL INSPECTION & CLEANING OF BOILER DRUM

2

-

-

... More
CLEANING AND REPAIR OF WIND BOX

-

-

-

... More
WITH STEEL

10

-

-

... More
WITHOUT STEEL

1600

-

-

... More
DYE PENETRATION TEST (DP TEST) WITH KIT

2000

-

-

... More
HYDRO JET CLEANING OF COMPLETE BOILER PRESSURE PARTS

-

-

-

... More
PLATEN SUPERHEATER COILS.

2

-

-

... More
PENDENT RE-HEATER COILS.

2

-

-

... More
FINAL SUPERHEATER

2

-

-

... More
WATER WALL ( FRONT, REAR, LEFT & RIGHT, ROOF)

2

-

-

... More
Section B

-

-

-

... More
ASSISTANCE IN RADIOGRAPHY

2

-

-

... More
RECTIFICATION, REPLACEMENT AND REFIXING OF CASSETTE BAFFLES IN VARIOUS AREAS OF BOILER TUBES.

300

-

-

... More
Erosion Shield

-

-

-

... More
FABRICATION & FIXING OF EROSION SHIELD

400

-

-

... More
FIXING OF EROSION SHIELD

3000

-

-

... More
REMOVAL OF EROSION SHIELD

3000

-

-

... More
PREPARATION OF BOILER TUBE SURFACE FOR TUBE THICKNESS SURVEY/OXIDE SCALE MEASUREMENT/STRESS RELIEVING

100000

-

-

... More
WELDING OF HP JOINTS OF BOILER TUBES

-

-

-

... More
WATER WALL TUBES-SCREEN TUBES, HANGER TUBES, REAR ARCH TUBES ETC.

1000

-

-

... More
PRIMARY SUPERHEATER TUBES

300

-

-

... More
PLATEN SUPERHEATER TUBES

400

-

-

... More
FINAL SUPERHEATER TUBES

400

-

-

... More
HORIZONTAL REHEATER

4000

-

-

... More
PENDANT REHEATER

600

-

-

... More
ECONOMIZER TUBES

1000

-

-

... More
SLING

10

-

-

... More
RISER

10

-

-

... More
BLEED

204

-

-

... More
HYDRASTEP

40

-

-

... More
INSTRUMENT PIPINGS

100

-

-

... More
WELDING OF FINS

400

-

-

... More
ECONOMISER/WATER WALL/CAGE WALL

2000

-

-

... More
SLING

200

-

-

... More
REHEATER

200

-

-

... More
DRUM VENT

100

-

-

... More
WELDING & REPLACEMENT OF DRAIN & VENTS JOINTS

400

-

-

... More
WELDING & REPLACEMENT OF TRACING LINE / SAMPLING LINE

40

-

-

... More
REPLACEMENT OF COILS- HORIZONTAL RE-HEATER(Bottom/Middle/Top)/ECONOMISER(TOP/MIDDLE/BOTTOM)

482

-

-

... More
PAD WELDING OF ERODED TUBES OF VARIOUS SIZE

-

-

-

... More
PAD WELDING OF BOILER TUBES AT VARIOUS LOCATIONS (SIZE 50MM X 50MM)

2000

-

-

... More
PAD WELDING OF BOILER TUBES AT VARIOUS LOCATIONS (SIZE 50MM X 100MM)

400

-

-

... More
PAD WELDING OF BOILER TUBES AT VARIOUS LOCATIONS (SIZE 50MM X 300MM)

400

-

-

... More
ALIGNMENT OF COILS/ TUBES / BLOWERS

-

-

-

... More
ALIGNMENT OF COILS OF SH DIVISIONAL PANEL/FINAL

40

-

-

... More
ALIGNMENT OF COILS OF PLATEN SUPERHEATERS

30

-

-

... More
ALIGNMENT OF COIL OF ECONOMISER

240

-

-

... More
ALIGNMENT OF COIL OF LTSH (UPPER / LOWER) / PRIMARY SH

230

-

-

... More
ALIGNMENT OF REHEATER COIL (HORIZONTAL / PENDENT)

355

-

-

... More
ASSISTANCE IN HYDRAULIC TEST OF BOILER PRESSURE PART & PREPARATION FOR BOILER LIGHT UP

2

-

-

... More
APPLICATION OF REFRACTORY AT VARIOUS LOCATIONS OF BOILER (GRADE A + PLASTIC)

-

-

-

... More
BURNER MOUTH

10

-

-

... More
APPLICATION OF REFRACTORY AT VARIOUS LOCATIONS OF BOILER (GRADE C + PLASTIC)

-

-

-

... More
PENT HOUSE, DOOR, WINDOW MANHOLE & PEEPHOLE, ETC

10

-

-

... More
DEAD CHAMBER & SCREEN VALVE

10

-

-

... More
COOLING PIPE OF SEAL PLATE (BOTTOM ASH HOPPER)

14

-

-

... More
OTHER AREAS (LIKE HOPPER HEADER ETC.)

6

-

-

... More
REMOVAL / BREAKING OF DAMAGED REFRACTORY & TRANSPORTATION

20

-

-

... More
Section C

-

-

-

... More
GLAND PACKING OF HP VALVES

-

-

-

... More
UPTO 25 MM

100

-

-

... More
25 MM TO 50 MM

120

-

-

... More
50MM TO 100 MM

40

-

-

... More
100 MM TO 200 MM

16

-

-

... More
COMPLETE SERVICING OF VALVES (EXCLUDING ACTUATOR):

-

-

-

... More
UPTO 25 MM

100

-

-

... More
25 MM TO 50 MM

150

-

-

... More
50 MM TO 100 MM

20

-

-

... More
100 MM TO 200 MM

10

-

-

... More
REPLACEMENT OF VALVES (WELDED TYPE)

-

-

-

... More
UPTO 25 MM

20

-

-

... More
25 MM TO 50 MM

20

-

-

... More
50 MM TO 100 MM

4

-

-

... More
100 MM And Above

4

-

-

... More
SERVICING OF MAIN STEAM STOP VALVE

4

-

-

... More
SERVICING OF VALVE/CONTROL VALVE OF FEED REGULATING STATION IN-SITU

16

-

-

... More
Section D

-

-

-

... More
COMPLETE SERVICING OF SPRING LOADED SAFETY VALVES (SV)

-

-

-

... More
BOILER DRUM SV

6

-

-

... More
MAIN STEAM LINES SV

4

-

-

... More
CRH LINES SV

8

-

-

... More
HRH LINES SV

4

-

-

... More
BAS LINE SV

4

-

-

... More
SECTION-E

-

-

-

... More
PREPARATION / FABRICATION OF HP TUBE BENDS

200

-

-

... More
REPAIR OF PENT HOUSE OF BOILER

-

-

-

... More
REPAIR OF PENT HOUSE BY PATCHING (WITHOUT STEEL)

1600

-

-

... More
DISMANTELING OF STEEL STRUCTURES/INSTALLATION OF NEW STEEL STRUCTURES (WITH STEEL)

10

-

-

... More
REPAIRING SEALING DEAD CHAMBER

2

-

-

... More
BUCKSTAYS

100

-

-

... More
DIAMOND TYPE LOCKS

100

-

-

... More
ROCKERS

100

-

-

... More
REPAIRING OF ECONOMISER HOPPERS & CONNECTION JOINT DUCTING & MAKING / STREGNTHEN OF THEIR PLATEFORM

2

-

-

... More
REPAIRING OF ECONOMIZER CASING

2

-

-

... More
REPAIRING OF BOTTOM ASH HOPPER LINER & SEAL TROUGH INCLUDING FIXING OF DIPPER PLATE

2

-

-

... More
REPAIRING OF FURNACE ZONE & REST OF THE AREAS

-

-

-

... More
WITH STEEL

4

-

-

... More
WITHOUT STEEL

600

-

-

... More
REPAIRING OF SECOND PASS CASING

-

-

-

... More
WITH STEEL

16

-

-

... More
WITHOUT STEEL

1200

-

-

... More
DISMNETLING, INSTALLATION, FEBRICATION OF STRUTURE & MISC. WORKS I.E. CANOPY, BROKEN STAIR/RAILING/DRAIN COVERING ETC.

10

-

-

... More
REPLACEMENT / STRENGTHENING OF BAFFLE PLATE BETWEEN PRIMARY SUPER HEATER & HORIZONTAL RE-HEATER

-

-

-

... More
WITHOUT STEEL

400

-

-

... More
REPAIRING/SEALING OF CAT HOUSE

2

-

-

... More
INSTALLATION OF MITP

20

-

-

... More
SERVICING, CLEANING & REPAIRING OF SAMPLING LINE COOLERS

4

-

-

... More
SERVICING & REPAIRING OF HANGERS & SUPPORTS

100

-

-

... More
REPAIRING OF Tapper DUCT & NEAR BY AREAS

-

-

-

... More
WITH STEEL

6

-

-

... More
WITHOUT STEEL

1400

-

-

... More
SECTION F

-

-

-

... More
REPAIRING OF RE-HEATER & SUPER HEATER AERO DYNAMIC DAMPER INCLUDING TOP / BOTTOM & NEAR BY AREAS

2

-

-

... More
DISPOSAL OF RUBBISH THERMAL INSULATION

2

-

-

... More
Insulation Work

-

-

-

... More
REMOVAL & APPLICATION OF THERMAL INSULATION IN COMPLETE BOILER FROM BOTTOM ASH HOPPER TO PENT HOUSE

4000

-

-

... More
REMOVAL & APPLICATION OF THERMAL INSULATION IN STEAM AND WATER PIPING

2000

-

-

... More
REMOVAL & APPLICATION OF THERMAL INSULATION IN ESP

2000

-

-

... More
REMOVAL & APPLICATION OF THERMAL INSULATION INAIR HEATER & HOPPER

2000

-

-

... More
COAL MILL, FUEL OIL AND ITS STEAM PIPING INCLUDING HEATERS FILTERS ETC.

1000

-

-

... More
FLUE GAS & HOT AIR DUCT

1000

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.