Indian Institute Of Management Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Indian Institute Of Management - IIM Tender

Works
Software and IT Solutions
Eprocure
Opening Date26 Apr 2024
Closing Date6 May 2024
Tender Amount₹ 36,49,361 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
OLT should support single line command to register Onts to the PON port. OLT should support Loopguard/storm control features. Detection /recovery time for loop should be configurable. The OEM Brand should be having valid ISO 9000, ISO 14000 and ISO 45001 cerficates, all these cerificates must be submitted in technical bid. Latest Datasheet should be attached with the Tender. Compliance should be attached with tender on OEM Letterhead, OLT/ONT/EMS including Splitters offered shall be of the same Make/manufacturer and shall be covered under same back-up guarantee from the same OEM, to Ensure full compatibility,Bidder should be Authorized Dealer/System Integrator of the quoted product. (Manufacturer Authorization Certificate from the principal specific to the tender should be enclosed with the bid). Approved Make : Cisco / Extreem / ZyXel / Ubnt / Digisol

1

-

-

... More
Supplying, Erecting & testing of Routers which includes Network Management Software compatible for GPON System and G.984.3 transmission convergence layer specifications, G.984.4 ONT management and control interface specification, Support DS/US transmission rate to 2.488 Gbps/1.244 Gbps,Wavelength: 1490 nm downstream & 1310 nm upstream,Comply with class B+ type PMD,Physical distance reach to 20 km,Support Dynamic Bandwidth Allocation (DBA),GPON Encapsulation Method (GEM) supports Ethernet packet,Supports GEM header removal/insertion and data extraction/segmentation (GEM SAR),Configurable AES DS and FEC DS/US,Support up to 8 T-CONs each with priority queues (US),Codecs: G.711 a/u, G.723, G.726,DTMF tone: detection and generation,Internal call, T.38 FAX relay, T30, Call waiting, Call hold/call retrieve,Call forwarding (No condition, Busy, No answer),Call transferring (Blind, ConsultOnHold, Attendant),

-

-

-

... More
Three-way conference, Support flexible traffic classification,Second call/Adding an outgoing call, Switch between 2 active calls,Port-based VLAN/802.1Q, DSCP/802.1P,IEEE 802.11n 2.4 GHz with up to 300 Mbps data rate,Wireless Protected Setup (WPS),WEP data encryption (64/128 bit),WPA/WPA2 (Wi-Fi Protected Access),Multiple SSID (up to 4),IGMP v1/v2/V3,Network Address Translation (NAT)/Network Address Port Translation (NAPT),Generic packet filter,Gateway/Firewall/DMZ,USB2.0 port for file sharing,WAN/PON: One Giga optical interface (SC/APC),Phone: Minimum One FXS phone ports RJ-11 for voice connectivity,ONT should support one SIP server to be mapped with one FXS port ,

-

-

-

... More
LAN: Four 10/100/1000Mbps Ethernet ports RJ-45,WLAN button: Wi-Fi tact Switch, WPS button: WPS tact switch,Reset: A tact switch. One reset/restore factory default button,Power switch: Push-push type button,Operating tempurature 0°C to 45°C (32°F to °F),Storage Temperature: -30°C to 70°C (-°F to 140°F),Power redundancy (Optional),Supported certificates: EMC: CE, Safety: CE LVD, Energy Saving: CE ErP,ONT should supply with SC/APC to SC/APC OFC Patch cord and loded SMB,Compliance should be attached with tender on OEM Letterhead,Latest Datasheet should be attached with the Tender. ,OLT/ONT/EMS including Splitters offered shall be of the same Make/manufacturer and shall be covered under same back-up guarantee from the same OEM, to Ensure full compatibility,,Bidder should be Authorized Dealer/System Integrator of the quoted product. (Manufacturer Authorization Certificate from the principal specific to the tender should be enclosed with the bid). Approved Make : Cisco / Extreem / Zyxel / Ubnt / Digisol

50

-

-

... More
Supplying, Erecting & testing of Network Management Software for the GPON System should have following features: -,Tenderer should carry out Installation, testing & commissioning as per Principle’s,The EMS /NMS should have Client-Server architecture. Server application must should support free based OS (Linux/Ubuntu) and client is support web based access support ,(OEM’s) Manual (if any) and instruction of site in charge., NMS should be capable of real time monitoring of all the device of the complete,Topology such as OLT, ONT, Splitter monitoring.,ONT Configuration from the EMS with the help of a script, Graph for Traffic.,ONT WAN configure remotely.,

-

-

-

... More
Batch ONT add by Script run., Inventory Check,Should be able to configure which can be done through CLI mode.,Multiple admin support and admin can restrict the access for sub-admin,Compliance should be attached with tender on OEM Letterhead,Latest Datasheet should be attached with the Tender. ,OLT/ONT/EMS including Splitters offered shall be of the same Make/manufacturer and shall be covered under same back-up guarantee from the same OEM, to Ensure full compatibility,,Bidder should be Authorized Dealer/System Integrator of the quoted product. (Manufacturer Authorization Certificate from the principal specific to the tender should be enclosed with the bid).,The 1U OLT should supports various interfaces including eight Gigabit Ethernet optical interfaces and four 10G interfaces; with which customers can have better flexibility and unified management to integrate more services. The 10G interfaces can be used with ERPS function for ring protection or to cascade other GPON devices without sacrificing bandwidth. Approved Make : Cisco / Extreem / Zyxel / Ubnt / Digisol

1

-

-

... More
Supplying, Erecting & testing of 1 x 8 Optical Splitter Optical Performance Requirements,Fiber typ G.657A,Operating Wavelength(nm) 1260nm~1650nm,A Class-≤4.0 dB,P Class ≤4.3 dB,S Class ≤4.5 dB,Environmental Performance Requirements,Should support Temperature -40℃~+85℃,splitter should support Immersion test temperature, tap water; 168h,Low temperature support -40 ° C (± 2 ° C); duration 96 h; online,Should support Salt spray test 5% NaCl, 6.5 PH 7.2; 35 ° C; duration 96 h,support Low temperature storage -40 ° C (± 5 ° C) or maximum storage temperature,,The OEM Brand should be having valid ISO 9000, ISO 45001, ISO 14001 cerficates, all these cerificates must be submitted in technical bid.,Compliance should be attached with tender on OEM Letterhead,Latest Datasheet should be attached with the Tender. ,OLT/ONT/EMS including Splitters offered shall be of the same Make/manufacturer and shall be covered under same back-up guarantee from the same OEM, to Ensure full compatibility,,Bidder should be Authorized Dealer/System Integrator of the quoted product. (Manufacturer Authorization Certificate from the principal specific to the tender should be enclosed with the bid). Approved Make : Cisco / Extreem / Zyxel / Ubnt / Digisol

8

-

-

... More
Supplying & drawing of Single Mode fiber 6 core: ‐Armored Uni‐Tube, 9/125μm,OS 2 Type Optical Fiber Cable, Cable Type : Optical fibers in water blocked loose tube, taped, corrugated steel tape armored (STA) polyethylene (HDPE) outer sheathed embedded with two steel wires on the periphery. The cables are with UV Stabilized PE Jacket and protected from Rodent attacks. Complying to ISO/IEC 11801, EN50173, ANSI/TIA 568-C.3, Telcordia GR-20; suitable for use in indoor / outdoor ducts, direct burial and backbone cabling. Fiber Type : Single Mode, 9/125-micron primary coated buffers, OS2 (IEC 60793-2-50, B1.3 and ITU T G652.d). Construction type : Uni-tube construction, Tube: Polybutylene, Terephthalate (PBT), Tube color: Polybutylene, Terephthalate (PBT), Tube color: White, Tube diameter : 3.0/2.0 mm nominal OD/ID, No of fibers: 6, Fiber color sequence : Blue, Orange, Green, Brown, Slate (Grey), White, Red, Black, Yellow, Violet, Pink, Aqua, Water Blocking : Thixotropic Gel (Tube) Petroleum Jelly (Interstices), (Continued...)

-

-

-

... More
Core Wrapping : Polyethylene Terephthalate, Armoring:Corrugated Steel Tape Armor (ECCS Tape) Thickness 0.125mm, Peripheral Strength Member : Two Steel wires (0.9 mm dia), Ripcord:Polyester based yarns below armored tape for easy ripping, Sheath thickness : 2.0 mm nominal, Sheath color : Black, Standards : ISO/IEC 11801 2nd Edition, type OS1/OS2; AS/ACIF S008; AS/NZS 3080 ; TIA/EIA 568.C.3; IEC-60793-1, 60793-2 EN50173, ANSI/TIA 568-C.3, Telcordia GR-20; suitable for use in indoor / outdoor ducts, direct burial and backbone cabling, RoHS Complaint, Mechanical characteristics : Required Value, Dimensions and Mass Overall, Cable (Nominal): 9.0 MM, Mass (Nominal), 80 kg/km +‐ 10 %, Cable length, 2 km ± 10%, Max. Bending Radius (During installation), 20 X Overall diameters, Max. Bending Radius (During full load): 10 X Overall diameters, Max. Tensile Strength‐Short Term : 1500N, Max. Crush Resistance‐ Short Term: 2000N/10 cm, Operating Temperature range : . ‐20°C ±70°C, Electrical/Optical Characteristics, Attenuation : Characteristics‐Optical Performance Max. Attenuation (Cable with fibers) At 1310 nm: 0.35 dB/km At 1550 nm: 0.22 dB/km Max. Average Attenuation; At 1310 nm: 0.33 dB/km At 1550 nm: 0.21 dB/km, Approved Make : Sysimax / Penduit / Molex / Legrand

3000

-

-

... More
Supplying & drawing of 2 Core Optical Fiber Drop cable,Feature:Specification,Feature & Benefits:All Dielectric Flat Drop Cable consists of 1-4 250μm individuallycoloured optical fibres with fibre reinforced plastic (FRP) strength membersand Low Smoke Zero Halogen (LSOH) jacket. Individually coloured optical fibres Notched construction for easy stripping White LSOH jacket for internal use,Application:Internal FTTH applications horizontaland riserContruction details:Number of elements :2Fibre Identification :Blue, Orange Tube Identification :Blue, Orange Central Strength Member:Fibre ReinforcedPlastic(FRP) 2 Nos(0.50±0.05mm)Outer Sheath : :LSZH (White)Packing length :1km or 2km per SpoolDimensions and Mass:Cable (Height):2.0 ± 0.2 mmCable (width):3.0 ± 0.2 mmMass (Nominal):9.0± 1 kg/kmFiber identificationfiber 1:bluefiber 2:orangeMechanical CharacteristicsMax. Bending Radius (during full load):20D ; D is ODMin. Bending Radius :32 MmMin. Tensile Strength-Short Term:60NMin. (Continued...)

-

-

-

... More
Crush Resistance-Short Term:500N/10 cm Operating Temperature range :-20°C ±60°CElectrical/Optical CharacteristicsMax. Attenuation;At 1310 nm : 0.35 dB/kmAt 1550 nm : 0.22 dB/km, Chromatic Dispersion1285-1330nm:≤3.5 ps/nm.km1550nm:≤18.0 ps/nm.km:Zero Dispersion Wavelength:1310 to 1324nmZero Dispersion Slope:≤0.092 ps/nm2.kmCable cut-off wavelength:≤1260 nmMode Field Diametre at 1310nm:8.8±0.4 μmCore clad Concentricity Eror:≤0.5 µmCladding Non Circularity:≤0.7 %Optical CharacteristicsCore Diameter:9.2 ± 0.4 μmCladding Diameter:125 ± 0.7 μmCore-Cladding Concentricity error:≤12.0 μmCoating Diameter:242 ± 5 μmFire performanceSmoke emmision: IEC 61034-1 & 2Flammability: IEC 60332-1Toxicity: IEC 60754-1Acid gas emission: IEC 60754-Commercial StandardsANSI/TIA/EIA-568-C.3,ISO/IEC 11801, ITU-T G.652D,ITU-T G657A1 & A2 Approved Make : Sysimax / Penduit / Molex / Legrand

2000

-

-

... More
Supplying of 2 Port Fibre Wall Outlet Features and Benefits FeatureSpecificationFeature & Benefits2 ports modular with adapter unloaded. This wall termination outlet is designed for FTTX applications, with standard 86*86mm dimensions to existing telephone/ network connections it is well suited to home or office environments. The outlet can support up to 4 fibres, A variety of adaptors (LC/SC, & square ST, FC) can be used giving the user aAllows SC Simplex, LC duplex, and square flange ST/FC simplex adaptors to be installedflexible solution.Integral fibre managementAccommodates splice protectorsMulti point fibre entryShutters for non-live portsStandard colour: whiteCommerical Standards:Compliant to RoHS, Reach / SVHCDesigned in accordance withTIA/EIA 568.C, ISO/IEC 11801, EN50173, IEC 60304, IEC 61754, EN297-1Product Specification:Material:ABS UL94V-0Operating Temperature:-40°C to + 50°CDimension:86 x 86 x 27 mm Approved Make : Sysimax / Penduit / Molex / Legrand

55

-

-

... More
Supply & fixing of Simplex SC/APC Adapter Features and BenefitsFeature & BenefitsSimplex SC adapters feature either a snap or flange mount and are designed to support the TIA/EIA commercial building telecommunication wiring standardsAdapters are also available as precise zirconia ceramic alignment sleeve. Utilises standard NTT-SC and Bellcore 326 compliant connectorsMeets TIA-568.3-D and IEC 874-109 standardsRoHS compliantAvailable in SInglemode and MultimodeColours - Singlemode (Blue), Singlemode APC (Green), Multimode (Beige/Aqua/Erica Violet/Lime Green)Zirconia ceramia alignment sleeveProduct SpecificationHousing:PolymerAlignment sleeve:Zirconia CeramicOperating Temperature:-40 to +75°C / -40 to +167°FDurability:1000 cycles minShipping Weight:35g Approved Make : Sysimax / Penduit / Molex / Legrand

150

-

-

... More
Supplying & fixing of SCAPC-SCUPC Simplex Type 9/125µm Singlemode OS2 Optical Fiber Patch Cords:-9/125 µm, OS2 , Simplex Zipcord.Connectors:The optical fiber patch leads shall comprise of Single-mode 9/125μm OS2 fiber with SCAPC type fiber connectors terminated at one end and SCUPC type fiber connectors at other end of the patch cord.Cordage O.D(Simplexlex): 2.0mm ± 0.1mm x 4.1± 0.2mmBuffer Diameter:900µ tight bufferStrength Member:Aramid YarnJacket Material:LS0H IEC 61034-1 & 2,IEC-60332-1, IEC-60754-1 & 2Connector Loss0.30dB(max)Operating Temperature:-40°C to +85°CStandardsISO/IEC 1108:2008, ANSI/TIA/ EIA 568.C.3, ANSI/TIA/EIA-492, TELECORDIA GR-409, ICEA-596 Approved Make : Sysimax / Penduit / Molex / Digisol

300

-

-

... More
Providing and Fixing of 12 Port Fiber Optic Rack Mount LIU with Adaptors Plates ,Splice Tray and Pigtails:-Connector Type:LC/SC-Style:Operating temperature:-20 Degree C to +70 Degree C or betterMM connectors:500 cycles, BeigeSM connectors:200 cycles, BlueFerrules:Pre-radiused Ceramic FerrulesAttenuation:Not more than 0.75 dB per mated pairFiber Optic Patch panels:12 Ports LoadedFMS- Front Patching / Splicing Shelf:1U 19” / ETSI versions availableThe FMS fiber management shelf series is ideal for high density front patching applications.Its compact design and high density capacity allows it to deliver carrier class fiber management to central offices, Pops, FTTx, mobile systems and LANs.High Density:1U: 12/24 Fiber terminations Upgradable Upto 96 LC port in 1 UShould be supplied loaded with secondary coated LC pigtails, Splice Tray & Splice ProtectorMounting brackets can be placed in different positionsSlidding Drawer concept allows for:Easy access to splicing trayEasy access to back side of connectorLabeling strip for adhesive labels and better cable managementFiber guides, radius controls & secure tie downs provided Approved Make : Sysimax / Penduit / Molex / Legrand

9

-

-

... More
Supplying and Fixing of 6A U/FTP Cable is specifically designed to support high speed data network applications such as 10-Gigabit Ethernet (10GBASE-T). The cable is constructed of 4 screened pairs and a drain wire. This cable minimises alien crosstalk, provides excellent signal isolation and provides superior electromagnetic interference (EMI) protection, Technical Characteristics "Primary Insulation: Polyolefin, Screen material: Laminated Aluminium, Sheath Type: PVC or LSOH (Flame Test IEC 60332-1), Nominal OD: 7.2, NVP: 75-77%, Screen: Each pair enclosed in, laminated aluminium foil : Drain Wire: tin-coated copper", Electrical Characteristics "Capacitance: 40 pF/m nom. @1 KHz., DC Resistance: 72 /Km max. Propagation Delay: 514 + 36f1/2 nS/100m, max @1-500 MHz, Propagation Delay Skew: 45 nS/100 max @ 1-500 MHz, Mean Impedance: 100 ± 6 @ 1-500 MHz, Resistance Unbalance: 2% max.

-

-

-

... More
Coupling Attenuation: 45dB min @30-100 MHz, 40-20 Log (f/100) @ 100-500 MHz", Applications "Category 6A U/FTP Cable is intended for high speed, data applications up to 500MHz including: IEEE 802.3 10GBASE-T 10Gb/s, IEEE 802.3 1000GBASE-T 1Gb/s, TIA/EIA-854 1000BASE-TX 1Gb/s, ATM 155Mb/s 155Mb/s", Operating Temperature "Storage: -20˚C to +75˚C, Operation: -20˚C to +60˚C" , "Commercial Standards: " "ANSI/TIA/EIA-568-C.2, ISO/IEC 11801 A1.1, ETL independant testing" ETL Certification : Compliant Approved Make : Sysimax / Penduit / Molex / Legrand

610

-

-

... More
Supplying and Fixing of Cat-6A Shielded Connectors/ RJ45 Plug (Toll Less )Minimum Specifications Should be conform to Category 6ARJ-45 meets TIA-568.2-D Category 6A component performance.IP 20 ratedPlug Insertion Life should be Minimum 750 timesShould support for 23-26 AWG wire size Should Supports 10GB networksContact plating material should have 50u” gold platingShall be RoHS CompliantShould be certified by ETL/UL. Approved Make : Sysimax / Penduit / Molex / Legrand

500

-

-

... More
Supplying of Floor Stand 42U Construction:Standard Rack configuration would be welded frame with 4 nos. of pillars of 1.5 mm thick CRCA sheet of 5 folded profile and welded from top to bottom for reinforcement. This is joined to top cover and bottom cover having air cooled ventilation for exhaust of hot air. Front door having provision of glass as well as perforation with adequate ventilation in the rear door. Both the Side panels are fitted with slam latches for easy removal.Frame:1.5 mm CRCA Multi Fold Fabricated Frame to achieve high structural Strength. Designed to carry load of 1250 Kgs. Easy to Assemble with the SKD design.Doors- Single, :Front Perforated Dual Door & Rear Dual Perforated door, Support Channels:Support Channel gets screw fixed directly to front & Rear frame. Gives High strength Load gets divide on robust Welded Frame. Top Panel:Made of 1.2 mm CRCA and concealed from exterior view. Allows provision for 4 nos. Fan mounting. Helps in easy installation like cable tray support 19” Rails, :4 nos. U marked Rails made of 2mm CRCA sheet. These are adjustable with the depth space provided in the rack.Certifications:Degrees of Ingress Protection (Continued...)

-

-

-

... More
Should be IP 20 according to IEC 60529 Degree of Impact Protection, IK 08 according to IEC 62262 Corrosion Resistance through Salt Spray test according to ISO 9227 for 168 hours protection Process validations thru’ NABL labs Ensures a Compliant & Robust Product, Weight Capacity:Weight carrying capacity upto 1250 Kg Process validations thru’ NABL labs Ensures a Compliant & Robust Product Weight Capacity:Weight carrying capacity upto 1250 Kg Painting Shade:RAL 9005 Fine Texture – 60 to 80uM. Powder Coating :Fine texture finish achieved through Epoxy polyester Hybrid Powder :60 – 80 Micron powder deposit Fine Texture Finish for Aesthetic appearance:High Scratch resistance against any sharp objectSide Panel:sheet steel, Removable Side panels, single point locking with quick release latchesCooling Fans :Fan's -230V AC - 90 CFM, dB 42 Power Distribution Unit - 06/13 or 6/16 Amp Multi-Standard - 12 Socket Set of 4 castors (2"/3" height), 2 of brakes on front side and 2 without brakesMounting Hardware Packets with set of M 6 screw, Cage Nuts and Washer set of 10 or 20Characteristics value Indicated (H x W x D) 1000Wx1200D - 42U, Fully Equiped with Required PDU and Blacnks Plates and Mounting Hardware, Approved Make : Netrack / Rittal / Tata / Valrack

1

-

-

... More
Supplying & fixing Cat 6 UTP jack with strain relief and bend limiting boot as required including polycarbonate modular type shuttered face plate, RJ-45 Data jack including GI /PVC box alongwith modular base & cover plate for modular switches in recess/ surface as required.

100

-

-

... More
Supplying & fixing of single partition (two-tier) 105 mm x 50 mm DLP U-PVC Trucking with all accessories including necessary cutting, fixing & finishing the same, placing in position, etc. as required. Make: Legrand or eqv)

50

-

-

... More
Making indoor type LAN OFC cable end termination of 6 core Optical Fiber Cable as required

60

-

-

... More
Supply, Erecting & testing of CAT6 Patch Cord as required. (Make- D-link, Molex,Avaya) (3 Mtr)

100

-

-

... More
Supply, Erecting & testing of Fibre Patch Cord with Fibre Module as required. (Make- D-link, Molex,Avaya, Legrand)

6

-

-

... More
Supply, installation testing, commissioning of 10 kva (Single Phase Out) ON-LINE Smart UPS SystemSimple Network Management Protocol ( SNMP card ) along with sealed lead acid batteries (Mainntenance free ) suiteble for 30 minnuts backup facility on full load with racks & connectors (including suitable size copper cable connection between ups ,battery bank and input power of UPS enlcuding MCCB or RCCB) complete with battery rack required One year warranty for ups & two years for battery.

1

-

-

... More
Supply & laying of 25mm dia permanent lubricated HDPE pipe in compliance with international quality standard to be used for fiber cable in the existing trench as underground conduits. Make: Finolex or equivalent

3000

-

-

... More
Supply installation of Prefabricated room Room of Size - 10'x10' Steel Structure - MS steel structure shall be designed as per prevailing codes & zone and same shall be completed with red oxide primer and good quality spray paint. Kindly Note: Structure will be designed as per the standards Walls - Providing & Fixing 0.5 mm thick profiled MS Sheet ((Specifications of Colour Coating - Base Substrate IS 15961 & Colour coated as per IS 15965, Al-Zn Coating - 150-200 g/m2, Primer paint + polyester paint coating (25 microns) min.)) in approved design on both sides with 50mm thick rockwool insulation in between as per direction of engineer in charge. Roof - Providing & Fixing 0.5 mm thick profiled MS Sheet ((Specifications of Colour Coating - Base Substrate IS 15961 & Colour coated as per IS 15965, Al-Zn Coating - 150-200 g/m2, Primer paint + polyester paint coating (25 microns) min.)) in approved design on both sides with 50mm thick rockwool insulation in between as per direction of engineer in charge. Roof will be completely water proof and providing & fixing of Rain water drains are inclusive. The height of the roof is 3 meters from flooring.

-

-

-

... More
Room Door - 1 No. - FLUSH DOOR - 30 mm (±2mm) thick Flush Door with L drop locking arrangements & Tower bolt and all related accessories and door shall be fixed with MS chokat and furnished with primer and paint (Including Hardware). Size of Door - 6'x2.5' Window - 1 No. - Window shall be made up of two track powder quoted aluminium Sliding Window having 4mm thick float glass with mosquito net, canopy and grill. Window will open on front side. With all the required accessories. Size of window - 2'x2'.

-

-

-

... More
Flashing - All type of required Flashing (Ridge/Corner/Gable Flashing etc.) in running meter. Hardware - All type of nut bolts self taping screws silicon or any other required hardware. Ply Board Below Tile Flooring - Providing and Fixing 18 mm thick Ply board in approved design below tile flooring on Ground Floor supported by MS structure complete as per the direction of the engineer in charge. Room Flooring - Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints. Size of Tile 600 x 600 mm of approved colour and design Make- JSW / TATA / ARCELOR MITTAL / Legrand

100

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.

10

-

-

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) (Make: L & T/Seimens / Schneider / Legrand / ABB / Havells / Hager)

-

-

-

... More
4 way (4 + 12), Double door

1

-

-

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: L & T/Seimens / Schneider / Legrand / ABB / Havells / Hager)

-

-

-

... More
Single pole

20

-

-

... More
Supplying and fixing 40 A to 50 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make:L & T/Seimens / Schneider / Legrand / ABB / Havells / Hager)

-

-

-

... More
Double pole

1

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make:L & T/Seimens / Schneider / Legrand / ABB / Havells / Hager)

-

-

-

1

-

-

... More
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 40/50 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required. (Make:L & T/Seimens / Schneider / Legrand / ABB / Havells / Hager)

1

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Make:L & T/Seimens / Schneider / Legrand / ABB / Havells / Hager)

-

-

-

... More
8 way , Double door

1

-

-

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. (Make:L & T/Seimens / Schneider / Legrand / ABB / Havells / Hager)

5

-

-

... More
Supply of 4 Core 16 Sqmm size of 1.1 KV grade mulit-core XLPE Armoured Aluminium Conductor Power cable conforming to IS 7098 (Part-1) / IS 1554 ( Part -1 ) with upto date amendments as required. (From Electrical Panel/MCB to DB) (Make: KEI/Finolex/RR Kabel/Havells/polycab/Lapp )

100

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
Upto 35 sq. mm

30

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.

-

-

-

... More
Upto 35 sq. mm

30

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.

-

-

-

... More
Upto 35 sq. mm (clamped with 1mm thick saddle)

40

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (Make for wire: Finolex/RR Kabel/Havells/polycab/Lapp) (Make for conduit :Precision/Avonplast/AKG/Modi/Polycab)

-

-

-

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

50

-

-

... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire

50

-

-

... More
2 X 10 sq. mm + 1 X 6 sq. mm earth wire

50

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

50

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

50

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Group C)

4

-

-

... More
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in Surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. (Group C)

2

-

-

... More
Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard length anti suicide down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts including connections with all necessary material complete as required confirming to IS :374/1979 with upto date ammendments. (Make: Crompton/Bajaj/Orient/Usha/Henolex/Havells)

-

-

-

... More
Ceiling Fan (5 star & ISI)-1200 mm Sweep

1

-

-

... More
Supplying and fixing of Deluxe fresh air fan with louvers (ventilating fan ) with self closing louvers of decorative PVC blades mounting square frame of approved make complete with all necessary material as required. (Make: Crompton/Bajaj/Orient/Usha/Henolex/Havells)

-

-

-

... More
200mm RPM1300/1400 Min.

1

-

-

... More
Supply and fixing of surface mounting LED down lighter of 1 to 3 W each assembled on single MCPCB, having color temp 4000K TO 6500K & having 25000 to 50000 burning hrs life with minimum @ L 80, system lumen output should be minimum with efficacy80lm/W. LED driver, PF 0.90. The colour rendering index of LED light should be more than 70. Housing made of CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 80-08 Form LED Source Manufacturer & LM79-08 / IS16106 from NABL approved lab. Manufacturer manadatory i/c connection wire, testing etc. to complete the job. 1 Yrs Guarantee certificate from manufacturer.

-

-

-

... More
Surface mounted round/square slim panel LED downlighter', 12W, 4-6.5K, Make: Wipro Model No. LD80-101-XXX-60-SM or equivalent in Philips, Crompton Greaves, Bajaj, Jaquar, havells etc.

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.