Electricity Department Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Electricity Department Tender

Works
Electrical and Electronics
Eprocure
Opening Date27 Dec 2023
Closing Date15 Jan 2024
Tender Amount₹ 9,71,48,388 
Notes
Download

Costs

  • EMD

    ₹ 19,42,968
  • Document Cost

    ₹ 1,500
  • Tender Fee

    ₹ 6,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with two Load Break Switches and one Circuit Breaker conforming to International Standards and complete with Fault Passage Indicator & SCADA Compliant as per technical specification.

17

9605000

565000

... More
Supply of 11KV, 630A, 25KA, 3 way Outdoor Load Break Switch comprising of 3 nos. 630A isolators and all required accessories, confirming to International standards complete with fault passage indicator as per Technical specs and SCADA compliant.

2

1230000

615000

... More
Supply of Outdoor type, heat shrinkable, three phase, end termination kit complete, for 11KV XLPE cable of size 3 x 95sq.mm including sockets /lugs / connectors etc. Make:- Raychem

17

172584

10152

... More
Supply of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11KV XLPE cable of size 3 x 95sq.mm including sockets /lugs / connectors etc.Make:- Raychem

17

114427

6731

... More
Supply of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11KV XLPE cable of size 3 x 300sq.mm including sockets /lugs / connectors etc.Make:- Raychem

40

353600

8840

... More
Supply Outdoor type, heat shrinkable, three phase, end termination kit complete, for 11KV XLPE cable of size 3 x 300sq.mm including sockets /lugs / connectors etc.Make:- Raychem

2

23334

11667

... More
Supply of 11KV, three phase, Heat shrinkable, Straight Through Jointing Kit complete for XLPE cable of size 3 core 300sq.mm.Make:- Raychem

54

1596186

29559

... More
Supply of Cable route Markers (for entire route length) as per technical specification and drawing.

240.16

126804

528

... More
Supply and Laying of Warning Tapes (for entire route length) as per technical specification and drawing.

12.46

186915

15000

... More
Design & Supply of RCC Hume pipes for road crossings, nullah crossings, small river crossings, culverts of 150 mm inner diameter, alongwith required no. of collars, PCC and Masonary work as per technical specifications.

520

211640

407

... More
Design & Supply of Medium duty, HDGI Class B pipe of nominal diameter 150 mm (alongwith HDGI bends wherever required) for bridge crossing, riser pipe for 95Sq.mm & 300Sq.mm XLPE Cable etc., as per technical specifications including supporting arrangement for the pipe.

180

302580

1681

... More
Supply of 3 phase, 50Hz, 11/0.433KV, 200KVA, Distribution Transformer complete, suitable for outdoor use and for plinth mounting.

2

754810

377405

... More
Outdoor LV Switch board with 1 no 630A ACB incoming and 4 nos 315Amps MCCB outgoing suitable for 200KVA Transformer centre made out of CRCA sheet with PU painted complete with all accessories and HDGI mounting channels.

2

458208

229104

... More
HDGI Fencing complete with Gate as per specification for Distribution Transformer (Size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5)Cu.mt. x 12 nos each. Ratio 1:3:6.

15

1150005

76667

... More
Supply of Distribution Transformer metering unit.

2

51376

25688

... More
Supply and fixing of CAMR Modem as per technical specification.

2

10000

5000

... More
Supply of underground cable protective cover as per specification. The concrete slab shall be machine made using semi-dry concrete that is batched infully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-Press" machine with a high vibration frequency and hydraulic pressure of 40 MT, the size of the slab shall be 480mm x 250mm x 50mm.(+/-2mm) and the concrete grade shall be M30 adhering to IS 456:2000 and shall have a minimun crushing strength of 30N/mm2 (28 days trength) when tested.

29248

3948480

135

... More
Supply and laying of fine river sand of approved quality (except sandy soil) for cushioning of 11KV/LT underground cables.

1528.95

3317821

2170

... More
Supply and laying of burnt clay wire cut bricks of 75 Kgs class.Wire cut bricks.

26779

241011

9

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundation of Ring Main Unit, Load Break Switch, Transformer & LV SwitchBoard

1.15

6366

5535.67

... More
Centering and shuttering including struttings, propping etc and removal of form work for Ring Main Unit, Load Break Switch, Transformer & LV SwitchBoard.

6.87

3867

563

... More
Providing of 12 mm cement plaster 1:4 (1- cement: 4-fine sand ) for foundations of Ring Main Unit, Load Break Switch, Transformer & LV SwitchBoard.

8.31

1221

147

... More
Brick work using common burnt clay building bricks in cement mortar 1:4 ( 1 cement; 4 coarse sand) in foundation and Plinth(b) with bricks of class designation 75 kgs/sq.cm ( wire cut bricks) for TRANSFORMER foundations.

2.81

20838

7416

... More
Earthing complete with 40mm GI pipe, 2.5mts long alongwith Batonite complete with brick masonary.

89

699362

7858

... More
Supply of HDGI flat of size 50mm x 5 mm including supply and fixing of required quantity of HDGI nut bolts for earthing of all euipment.

1335

213600

160

... More
Cost of Erection

-

-

-

... More
Laying of UG cables by open trench method. (Excavation of trench is shown as separate item)

9000

3078000

342

... More
Laying of 11KV UG cables by trenchless technology by adopting horizontal directional drilling (HDD Method) The work includes preparation of site . Boring as wll as drawing of cable in normal soft/hard soil with minimun 8" bore size, including Supply and erection of HDPE pipe 110 mm PN6 PE 80 wall thickness 6.5 mm.(minimum) as per IS 4984:1995 ammendment 2016. The depth shall be 1.65 m to 1.85 m(1650mm-1850mm) only except at entryand exit pits where minimum depth shal be 1200mm.

7004

19611200

2800

... More
Erection, Testing & Commissioning of 3 core, 95sq.mm. aluminium, XLPE insulated, Flat Type armoured, 11KV (Earthed) Cable, type A2XFY conforming I.S. 7098 PART 2 and carrying ISI MARK (for the Ring Main Unit to Distr. Transformer)

255

50745

199

... More
11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with two Load Break Switches and one Circuit Breaker conforming to International Standards and complete with Fault Passage Indicator & SCADA Compliant as per technical specification.

17

165240

9720

... More
Erection & Commissioning of 11KV, 630A, 25KA, 3 way Outdoor Load Break Switch comprising of 3 nos. 630A isolators and all required accessories, confirming to International standards complete with fault passage indicator as per Technical specs and SCADA compliant.

2

19440

9720

... More
Erection, Testing and Comissioning of Outdoor type, heat shrinkable, three phase, end termination kit complete, for 11KV XLPE cable of size 3 x 95sq.mm including sockets /lugs / connectors etc. Make:- Raychem

17

45016

2648

... More
Erection, Testing and Comissioning of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11KV XLPE cable of size 3 x 95sq.mm including sockets /lugs / connectors etc.Make:- Raychem

17

43146

2538

... More
Erection, Testing and Comissioning of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11KV XLPE cable of size 3 x 300sq.mm including sockets /lugs / connectors etc.Make:- Raychem

40

101920

2548

... More
Erection, Testing and Comissioning of Outdoor type, heat shrinkable, three phase, end termination kit complete, for 11KV XLPE cable of size 3 x 300sq.mm including sockets /lugs / connectors etc.Make:- Raychem

2

5436

2718

... More
Erection, Testing & comissioning of 11KV, three phase, Heat shrinkable, Straight Through Jointing Kit complete for XLPE cable of size 3 core 300sq.mm.Make:- Raychem

54

200502

3713

... More
Erection and Comissioning of Cable route Markers (for entire route length) as per technical specification and drawing.

240.16

61480

256

... More
Erection of RCC Hume pipes for road crossings, nullah crossings, small river crossings, culverts of 150 mm inner diameter, alongwith required no. of collars, PCC and Masonary work as per technical specifications.

520

78520

151

... More
Erection of Medium duty, HDGI Class B pipe of nominal diameter 150 mm (alongwith HDGI bends wherever required) for bridge crossing, riser pipe for 95Sq.mm & 300Sq.mm XLPE Cable etc., as per technical specifications including supporting arrangement for the pipe.

180

32760

182

... More
Erection, Testing and Comissioning of 3 phase, 50Hz, 11/0.433KV, 200KVA, Distribution Transformer complete, suitable for outdoor use and for plinth mounting.

2

31276

15638

... More
Outdoor LV Switch board with 1 no 630A ACB incoming and 4 nos 315Amps MCCB outgoing suitable for 200KVA Transformer centre made out of CRCA sheet with PU painted complete with all accessories and HDGI mounting channels.

2

25000

12500

... More
HDGI Fencing complete with Gate as per specification for Distribution Transformer (Size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5)Cu.mt. x 12 nos each. Ratio 1:3:6.

15

600000

40000

... More
Erection of Distribution Transformer metering unit.

2

2144

1072

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/ manual means in foundation pipeline trenches drain (not exceeding 1.5 mt in width or 10 sq.m on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m(a) for laying of HT/LT cables of various sizes in all kinds of soil, hard rock , providing barricading, danger lighting guarding etc. The trench lengths are as follows:

-

-

-

... More
All kinds of soil/rocks/laterite stone

-

-

-

... More
Size 1.1 x 0.4 x HT cable length mts for laying of 1 run.

3649.64

1708031

468

... More
Size 1.1 x 0.6 x HT cable length mts for laying of 2 run.

3358.08

2562215

763

... More
Filling of available excavated earth (excluding rock/stones) in trench in layer not exceeding 0.2mts. Depth, consolidating each deposited layer by ramming and watering lead up to 40mts.

4459.46

535135

120

... More
Rubble packig with hard laterite stone inder floors including watering, ramming and concolidating etc in pipeline trenches and other foundations complete for

-

-

-

... More
a) Single circuit 11KV Cable trench

1032.22

2282238

2211

... More
b) Double circuit 11KV Cable trench

310.86

687311

2211

... More
Laying of underground cable protective cover as per specification. The concrete slab shall be machine made using semi-dry concrete that is batched infully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-Press" machine with a high vibration frequency and hydraulic pressure of 40 MT, the size of the slab shall be 480mm x 250mm x 50mm.(+/-2mm) and the concrete grade shall be M30 adhering to IS 456:2000 and shall have a minimun crushing strength of 30N/mm2 (28 days trength) when tested.

29248

1754880

60

... More
Earthing complete with 40mm GI pipe, 2.5mts long alongwith Batonite complete with brick masonary.

89

436723

4907

... More
Erection of HDGI flat of size 50mm x 5 mm including supply and fixing of required quantity of HDGI nut bolts for earthing of all euipment.

1335

49395

37

... More
Carrying out detailed physical survey of the area including detailed Ground penentrating Radar survey which includes indicating and marking location of other utilities if any, furnishing of optimum and economical route and design for laying of 11KV, 3 core, 300 sq.mm, XLPE cable and accessories, including plotting on the scaled land base map of size 1:1000 indicating all features, and submitting drilling profile indicating proposed plan for HDD, open trenching, road, nullah, culvert, over bridge, rail crossing or any other special crossing. The work shall include digging of trial pits at suitable intervals and re-instatement of dug-up area of trial pits. The Detailed documents as well as the write-up shall be furnished in 2 nos. of hard copies and soft copies for approval. Upon approval fresh 6 Nos. of hard copies alongwith a soft copy shall be furnished duly corrected. On completion, the contractor has to submit final survey map with longitude and latitude of each every item with other details for Asset Mapping.

10110

151650

15

... More
Dismantling of 11 KV Pin insulators with G.I. Pin

180

13680

76

... More
Dismantling of 11 KV Disc insulators 70 KN with metal parts for 11 KV Disc 70KN.

120

22500

187.5

... More
Removal of RCC Poles-9mtr

35

77140

2204

... More
Dismantling of M.S. Rail Pole 105 lb/yd 11 mts

10

133175

13317.5

... More
Removal of ACSR conductor 'WEASEL'

1.5

5332

3555

... More
Removal of ACSR conductor 'RACCOON'

9.6

49603

5167

... More
Dismantling of HDGI 11 KV V-Shape 'X' arm

60

10140

169

... More
Dismantling of Cut point channel 1.3 mtr long

18

4428

246

... More
Dismantling of HDGI top fitting cross arm ISMC channel 75x40x6mm, 0.7mtrs long for 11KV

72

8208

114



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.