Board Of Secondary Education Tender
... More
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Board Of Secondary Education Tender
Civil And Construction
Building Construction
Eprocure
Opening Date16 Jan 2024
Closing Date30 Jan 2024
Tender Amount₹ 70,25,015
Costs
EMD
₹ 70,250Document Cost
₹ 10,000Tender Fee
₹ 830
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MPBSE_326763_1Bid Award Id
ViewTender No
TN/227/Bldg/e Tender/24 BPL dt 09-01-2024Tender Authority
Board Of Secondary Education ViewPurchaser Address
-Website
http://http://rajeduboard.rajasthan.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supplying and erection of 33KV (10 KN) polymer pin insulator complete with long steel head G.I. pin, nut, washer etc. as required
15
8925
595
... More
Supplying and erection of 33KV (45 KN) polymer disc insulators for 33KV overhead lines with galvanized insulator fittings, ball and socket type, and complete with galvanized strain clamp, bolts, nuts, washers etc. as required
12
12216
1018
... More
Supplying installing, testing & commissioning of outdoor H.T., AB switch assembly set gang operated with brass contact parts, including required GI pipe operating rod, handle & locking arrangement on OnOff position conforming to IS complete with required material and installing on existing DP structure to complete the job as required as per specification.(Set of 3 nos.)33KV, 600Amp
2
63050
31525
... More
Supplying installing, testing & commissioning D.O. fuse assembly with brass part contact for 33 or 11/0.4 KV DP Structure set of 3 Nos. with fuse barrel i/c required fuse element & other materials as per specification on existing D.P. structure as required33KV
2
32000
16000
... More
Supplying and erection of single piece non-linear resistor polymer type lightning arrestor (set of 3 nos) for 3 wire, 33KV overhead lines/ sub-station with rated voltage of 27KV (rms) with a nominal discharge current rating of 10 KA and complete with galvanized clamping arrangement, G.I. bolts, nuts, washer etc. as required.
2
71394
35697
... More
Supplying & installing G.I. pipe for protection of underground cable fixed on wall/support/in trench/fixed between two rigid existing support of wall/beam for erection of ceiling Fan/down rod for stiff pendent for light luminaries /fan/protective for earthing, lightening conductor down strip/overhead service line/for submersible cable or centrifugal pump for water supply with necessary iron clamp coupler, bend, tee, elbow, nuts and bolts etc. complete in an approved manner as required to complete excluding cost of excavation/dismantling & other finished masonry Item complete.For 'A' class G.I. pipe ISI marked(IS1161-69) 100.00mm
566
651466
1151
... More
Prima coat over new steel and other metallic surface with red oxide zinc chromide paint complete with supply of material labour etc. including preparation of surface.152x6=912mm=0.912 mtrx13x6=71.136sq mtr
71.14
5406
76
... More
Prima coat with aluminium paint, brushing complete with material and labour including preparation of surface152x6=912mm=0.912 mtrx10.8x6=59.09sq mtr
59.09
5672
96
... More
Supplying, drawing and testing of XLPE insulated covered aluminium conductor of approved make, stringing, making off complete with binding at existing insulator, jointing, jumpering, tearing off, connecting etc. as required and clearing of obstacles (if any) etc99 Sqmm XLPE 33KV grade
0.07
47530
679000
... More
Supply and erection of approved make safe earthing electrode consisting pipe-in-pipe technology as per IS 3043-1987 made of corrosion free G.I. pipes with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for effective and maintenance free earthing in earth pit of minimum bore dia. 150mm size, as mentioned below :With 3 metre pipe of 80mm outer dia., 40mm inner dia and 14mm terminal dia. In soft/hard rock/marshy soil with 50 kgs. (two bag) back filling bentonite compound UL listed and confirm to relevant International/Indian standards around electrode upto ground level.With 3 metre pipe of 80mm outer dia., 40mm inner dia and 14mm terminal dia. In soft/hard rock/marshy soil with 50 kgs. (two bag) back filling bentonite compound UL listed and confirm to relevant International/Indian standards around electrode upto ground level.
14
299866
21419
... More
Supply and laying 50mm X 6mm G.I. strip at 0.5 metre below ground level/surface as strip earth electrode including jointing etc. as required.
200
63800
319
... More
Designing and construction of pedestal (plinth) for transformer of desired size including excavation in hard rock/soft rock, base concrete M-7.5 (1:4:8), 20mm metal and pedestal of RCC M-15 (1:2:4) including required tar steel reinforcement for required height as per IE rules from base concrete including shuttering and finishing with 10mm thick plaster in cement mortar 1:3 curing & white washing etc. complete as per specifications.
10
73790
7379
... More
Supplying, installing, testing and commissioning of 33/0.4 KV 3 Phase 50 cycle oil immersed, naturally cooled, outdoor type transformer connected delta on H.T. side and star on L.T. side, hand operated off load Tap changer switch, rating and diagram plate, two earthing terminal, lifting lugs, oil level gauge, drain valve with plug, temperature not exceeding 50ºC on load, temperature dial gauge, Bucholz relay, oil conservator with drain plug, oil filling hole with plug, dehydrating silica gel breather on eye level, four unidirectional roller, arcing horns, explosion vent, terminal arrangement bushing on H.V. side and cable box on LV side, first filling of oil upto desired level and transformer installing on existing structure with all required materials arrangement as required ISI marked & as per IS specification.Copper wound, 1000 KVA
1
2108565
2108565
... More
Supplying, installation, testing and commissioning of triple pole outdoor type 11KV/33KV vacuum circuit breaker with outdoor control & relay panel with numerical static relay for feeder protection (1F). The installation of VCB shall be carried out in accordance with IS: 3072. The VCB shall be mounted on suitable size duly painted MS channel/angle iron structure with nut bolts and washer. The structure shall be fixed on existing cement concrete foundation. The complete work should be done as per IS specification.33 KV, 1250A VCB
1
319644
319644
... More
Supplying, installation, testing and commissioning of single phase C.T./P.T. outdoor type 11KV/33KV with terminal box. The C.T./P.T. shall be mounted on existing structure fabricated with suitable size MS channel/angle iron structure with nut bolts and washer duly painted. The structure shall be fixed on existing cement concrete foundation as per IS specification as mentioned below33 KV CT outdoor type 200-100/5 Amp
3
54882
18294
... More
Supplying, installation, testing and commissioning of single phase C.T./P.T. outdoor type 11KV/33KV with terminal box. The C.T./P.T. shall be mounted on existing structure fabricated with suitable size MS channel/angle iron structure with nut bolts and washer duly painted. The structure shall be fixed on existing cement concrete foundation as per IS specification as mentioned below33 KV/110V single phase PTs oil immersed
3
61464
20488
... More
Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor3½ core armoured, 300 sq. mm.
100
179200
1792
... More
Laying of one number armoured / unarmoured power cable 1.1 KV grade of size exceeding 120 sq. mm but not exceeding 400 sq. mm. in the existing RCC Hume /Stone ware/G.I. Pipe/surface in existing trench as required.
100
5400
54
... More
Supply of ISI marked and approved make of air circuit breaker (ACB) with microprocessor release with overload, short circuit, neutral protection, instantaneous, ground fault protection (LSING) Ics=Icu=Icw for 1sec for total selectivity, ambient temperature 50deg.C, In with breaking capacity of 50 kA/60kA/75kA, 4 pole, 415 Volts conforming to IS/IEC : 60947-21600Amp, manual, drawout 50kA
1
365740
365740
... More
Supply of ISI marked and approved make of moulded case circuit breaker (MCCB) suitable for 3 phase,3 pole, 50 Hz, 415 Volts, AC supply with respective interrupting capacity (KA) at 415 Volts cited against their range standard conforming to IS – 8828MCCB 400A, 36kA, 3P MCCB 36kA current rating, 3P -400Amp &adjustable:
4
97652
24413
... More
Supply, fixing, testing & commissioning wall/floor mounted LT panel primer coated with powder coated paint & provided with required gasket for dust/vermin proof with degree of protection IP42 suitable for 415Volt 3 phase, 50 Hz, 4 wire system fabricated out of CRCA sheet upto 2 mm thick (1.6 mm for doors) duly compartmentalized for incomer, bus section, outgoings, cable alleys & CT, PT Ampere Metre, Volt Metre, selector switches, frequency Metre, phase indicating lamp, Energy Metre complete including cost of busbar supports, detachable cable gland plates, 2 earthing terminals, internal wiring & fixing of separately supplied MCBs, MCCBs, ACB, panel mounted changeover switch/SFUs, etc. as required but excluding cost of busbar strips, Ampere Metre, Volt Metre, selector switch as per approved design & specification
200
79400
397
... More
Supply and fixing of LT panel accessories of approved make in existing LT panel including connections etc. as required as per specification
-
-
-
... More
Aluminium bus bar strips with PVC sleeves (100x10 mm) Double
100
28400
284
... More
Digital Ampere Metre with CTs with selector switch
5
10625
2125
... More
Digital Volt Metre with selector switch & HRC fuse
1
2398
2398
... More
LED lamp indicator
15
3825
255
... More
Supply of approved high-tension XLPE cable (conforming IS-7098/II/85) as per ISI standard 3 core armoured with alu. solid/stranded conductor ISI marked as required3 core XLPE cable 33 Kv grade, 95 sq. mm.
760
1270720
1672
... More
Laying of one number 3 core H.T armoured/unarmoured power cable 33KV grade of size not exceeding 300 sq. mm in the existing RCC/hume/stoneware/G.I. pipe/surface in existing trench as required.
566
28300
50
... More
Laying of one number 3 core H.T armoured/unarmoured power cable 33KV grade of size not exceeding 300 sq. mm. in the existing masonry open duct as required
176
8624
49
... More
Laying of one number 3 core H.T armoured/unarmoured power cable 33KV grade of size not exceeding 300 sq. mm on wall/pole etc. as required.
8
1216
152
... More
Laying of one number 3 core H.T armoured/unarmoured power cable of grade 33KV of size not exceeding 300 sq. mm direct in ground including excavation in all soil/murrum/soft rock, sand cushioning, excluding protective covering and refilling the trench etc. as required
5
1150
230
... More
Laying of one number additional 3 core H.T armoured/unarmoured power cable 33KV grade of size not exceeding 300 sq. mm direct in ground in the same trench in one tier horizontal formation including sand cushioning, excluding protective covering and refilling the trench etc. as required
5
715
143
... More
Supplying and erection of stay set complete with 19/20mm.dia 1.8 metre long stay rod, turn buckle, anchor plate of size 300mm x 300mm x 7.5mm thimble stay clamp, bow tightener, 7/4.00 dia G.I. stay wire etc. in cement concrete M-10 (1 cement: 3 coarse and: 6 granded stone aggregate 40mm nominal size) foundation including excavation and back refilling etc. as required.
1
4856
4856
... More
Supply & fixing anti climbing device with 2 ply G.I. barbed wire 1 Kg. per pole complete as per MPMKVVCO. Specification
6
1386
231
... More
Supply, laying and fixing of G.I. earth coil of 4mm dia G.I. wire having 120 turns of nearly 50mm dia. and 3 mt. long tail in existing pit duly earthed with pole etc complete as required as per specification.
6
1758
293
... More
Supplying and fixing 33/11/0.4 KV enamel coated danger board size 200x250mm with clamp on existing HT/LT structure/poles.
6
1230
205
... More
Supplying and fixing limit switch with accessories & arrangement on existing HT/LT structure/poles AB switch handle for inter locking between distribution panel main incoming LT switch gear/ system as required to complete the job.
1
4851
4851
... More
Supply of XLPE insulated FRLS heavy duty power cable conforming IS-7098 (Part-1) 1988, 1100 Volt grade, 2/3/4/8/10/12 core ISI marked with copper stranded/solid conductor.
-
-
-
... More
Armoured, 2 Core 2.5 sq. mm
20
2720
136
... More
Armoured , 10 Core 2.5 sq. mm
100
46900
469
... More
Providing & Making cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 33 KV/11 KV 3 core XLPE alum. conductor cable as required as per specification and as per accepted standard including connection testing complete.Heat shrinkable joint, kit 33 KV XLPE, 3 core, Heat shrinkable jointing kit 33 KV XLPE cable O.D. termination, 3x 70-95 sq. mm.
6
97866
16311
... More
Supply & fixing fencing of chain link mesh 100 x 100 mm, 12 SWG GI wire for for D.P. structure electric sub-station switch yard including single post of angle iron size 50x50x5mm, 2.5 mt long should be provided upto 2.00 mt. apart or as required. The panel frame with required angle iron/ flat iron members/cross members including mesh welded in frame panel shall be erected between the posts. The angle iron post shall be erected in cement concrete M-15 (1:2:4) (20 mm graded metal) foundation, including excavation of pit and refilling the same. The fencing shall be provided with one entrance gate including locking arrangement as required as per specification. The height of fencing shall be 2 mt. above ground level. Fencing shall be painted with required shade.
88
160248
1821
... More
Collection and spreading of metal dust, murum and 40mm graded hard metal in sub-station yard or as required as mentioned below -Metal 40 mm
60
88680
1478
... More
Supply of fiber D.O operating rod for 11/33KV tested
1
3854
3854
... More
Supply of first aid box complete with medicine & bandage as per specification
1
1646
1646
... More
Supply of shock instruction chart duly framed with glass, as reqd
4
2156
539
... More
Supply, installation, testing & commissioning of HT trivector energy meter, DLMS compliant category-A (for substation/feeder metering energy audit), 3 phase 4 wire, 110 Volts, 5 Amp, accuracy class 0.5S with GSM (GPRS compatible) modem suitable for required C.T. including uPVC box/sheet metal box with TTB duly tested from electricity board.
1
22454
22454
... More
Supply of rubber mat 2 x 1.0Mtr, 1100V tested
8
15304
1913
... More
Supply of hand gloves 33KV tested
2
2582
1291
... More
Supply of fiber discharge rod I/C connection copper lead tested
1
4042
4042
... More
Excavation of the trenches in hard rock not exceeding 1.5 metre in width and lift upto 1.5 metre including getting out the excavated metal and disposal of surplus excavated soil/metal as directed within the lead of 50 metre (without blasting)
166
114706
691
... More
Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. (No extra lift is payable if work is done by mechanical means). All kinds of soil
20
2580
129
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : With 20mm nominal size graded stone aggregate. M-15 Grade concrete
3.46
15469
4471
... More
Supplying and filling in plinth with crusher stone dust / coarse sand under floors including, watering, ramming consolidating in layers not exceeding 20cm in depth and dressing complete. Note: - Maximum thickness of this
layer shall be 20 cm.
6.4
4300
672
... More
Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone aggregate) excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :M 20 –Grade Concrete
2.8
17228
6153
... More
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire up to floor two level including all wastage etc. complete.Thermo-Mechanically Treated bars.(TMT/TMX) FE 500 D conforming to IS 1786.
196
15680
80
... More
Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for concrete up to plinth level.
36
6861
190.6
... More
40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 sand) including pointing with cement mortar 1:2 (1 cement : 2 sand) with an admixture of pigment to match the shade of stone.Red sand stone
10
6420
642
... More
Brick work with well burnt chimney bricks in bulls patent trench kiln manufactured by ghol process, crushing strength not less than 40kg /cm2 and water absorption not more than 15% in foundation and plinth i/c curing etc complete.Cement mortar 1:6 (1 cement : 6 sand)
9.24
51984
5626
... More
12 mm cement plaster of mix : 1:6 (1 cement : 6 sand)
35.2
5632
160