Board Of Secondary Education Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Board Of Secondary Education Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date23 Oct 2023
Closing Date6 Nov 2023
Tender Amount₹ 14,43,815 
Notes
Download

Costs

  • EMD

    ₹ 28,876
  • Document Cost

    ₹ 2,000
  • Tender Fee

    ₹ 295

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Extra long -II

14

56630

4045

... More
Extra long -III

20

100660

5033

... More
Supplying and fixing PVC conduit ISI marked FRLS along with accessories on surface etc. as required

-

-

-

... More
PVC conduit 20 mm. (MMS)

50

2550

51

... More
PVC conduit 25mm. (MMS)

100

6700

67

... More
Supplying and drawing single core PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification.4.00 sq. mm. Wire

-

-

-

... More
3 X 4.00 sq. mm.

180

24120

134

... More
Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:-3 Module PVC box

41

7257

177

... More
Supplying of approved make, powder coated metal double door vertical TPN MCB DB IP 43 protection with provision for MCCB upto160A TP/FP 36kA as incomer and space for SP/TP MCBs as outgoing (without MCCB/MCBs) inclusive of busbar & connections etc4 Way without MCCB

4

55288

13822

... More
Supply of ISI marked and approved make of moulded case circuit breaker (MCCB) suitable for 3 phase,3 pole, 50 Hz, 415 Volts, AC supply with respective interrupting capacity (KA) at 415 Volts cited against their range standard conforming to IS – 8828MCCB 25kA current rating, 3P -160Amp & 80% -100% adjustable

4

50804

12701

... More
Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :-Single poleMCB SP 6Amp to 32Amp 10kA rating

48

12624

263

... More
Labour charges for fixing sheet steel enclosures, MCB DB surface mounting type, as per accepted practice on 25x25x 5 mm angle iron clamp, including supplying and fixing of clamp duly embedded in wall, cable connection etc. complete :-For item no :-27.11.6 & 27.11.7; 27.12.5 ; 27.13.2 to 27.13.4 & 27.14.1 to 27.14.4 ; 27.15.1 to 27.15.4

4

1656

414

... More
Fixing of MCB/MCCB/Isolator in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete (labour only)

-

-

-

... More
MCB/Isolator SP/DP

48

1056

22

... More
MCB/MCCB Isolator TP/TPN/FP

4

112

28

... More
Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor3½ core armoured

-

-

-

... More
35 sq. mm

120

33600

280

... More
70 sq. mm

160

80000

500

... More
Laying of one number armoured / unarmoured power cable 1.1 KV grade of size exceeding 25 sq. mm but not exceeding 120 sq. mm. in the existing RCC Hume /Stone ware/G.I. Pipe/surface in existing trench as required.

280

9800

35

... More
Supply, fixing, testing & commissioning wall/floor mounted LT panel primer coated with powder coated paint & provided with required gasket for dust/vermin proof with degree of protection IP42 suitable for 415Volt 3 phase, 50 Hz, 4 wire system fabricated out of CRCA sheet upto 2 mm thick (1.6 mm for doors) duly compartmentalized for incomer, bus section, outgoings, cable alleys & CT, PT Ampere Metre, Volt Metre, selector switches, frequency Metre, phase indicating lamp, Energy Metre complete including cost of busbar supports, detachable cable gland plates, 2 earthing terminals, internal wiring & fixing of separately supplied MCBs, MCCBs, ACB, panel mounted changeover switch/SFUs, etc. as required but excluding cost of busbar strips, Ampere Metre, Volt Metre, selector switch as per approved design & specification

160

63520

397

... More
Supply and fixing of LT panel accessories of approved make in existing LT panel including connections etc. as required as per specification.

-

-

-

... More
Digital Ampere Metre with CTs with selector switch

1

2125

2125

... More
Digital Volt Metre with selector switch & HRC fuse

1

2398

2398

... More
Copper bus bar strips with PVC sleeves

25

19700

788

... More
Aluminium bus bar strips with PVC sleeves

10

2840

284

... More
LED lamp indicator

3

765

255

... More
Supply of ISI marked switch disconnector fuse (SDF), open execution (Panel mounting cubicle type) conforming to IS:13947 (part I & III ) 3 pole and neutral, AC -23A ,50 Hz , 415 Volt with 3 HBC fuses complete.

-

-

-

... More
100Amp

8

37744

4718

... More
200Amp

1

8074

8074

... More
320Amp

1

12215

12215

... More
AC installation: - Installation of split type wall mounted air conditioner indoor, outdoor unit fitted with rotary compressor, copper condenser and first charge refrigerant R410A, including connection of copper pipe and material supplied with complete unit etc as required. (excluding cost of copper pipe)

10

15000

1500

... More
Gas charging (R410A/Eco Friendly Green Gas) of window/split air conditioning unit including flushing of cooling & condensing units with nitrogen gas & rectification of leakage, replacement of filter, flair nut etc. if any.2.0 TR

10

20420

2042

... More
Supply, installation, testing & commissioning of suction/discharge copper pipe line in split air conditioning unit 1.0/1.5 TR/2 TR/3 TR capacity including brazing, nitrile rubber insulation 6/9mm thick class 'O', etc complete as required.

-

-

-

... More
Copper tube 1/4"

20

8740

437

... More
Copper tube 3/8"

20

11000

550

... More
Copper tube 1/2"

100

65700

657

... More
Copper tube 5/8"

100

81500

815

... More
Supply and fixing of multi core round FRLSH PVC insulated copper (flexible) conductor & PVC sheathed cables 1100Volts as per IS:694-1990 of approved make(56/0.3 mm) Three core 4.0 sq.mm.

200

26400

132

... More
Replacement & connection of thermostat switch of required size & capacity for Refrigerator upto 300 ltr capacity including all required material to complete the job.

10

16840

1684

... More
Replacement & connection of starting relay required size & capacity for Refrigerator upto 300 ltr capacity including all required material to complete the job.

10

9390

939

... More
Split AC (non inverter) :- Supply installation testing and commissioning of split type wall mounted air conditioning unit of following capacity including indoor, outdoor unit fitted with rotary compressor, copper condenser and first charge refrigerant R410A. The condensing unit working range should be capable of providing cooling between +/-5deg.C to 50 deg. C including connection of copper pipe of required size upto 3 mtr., insulation, cordless remote control, auto air swing louvers, wall stand for outdoor unit, connection copper lead wire, condense water outlet pipe 2 mtr. complete etc as required. Outdoor/indoor units should be of same make (brand). 1.8/2 TR star rating 3 sta

10

530290

53029

... More
Drain piping :- Providing and fixing of CPVC, 6Kg/cm2 drain water piping with fittings, support and insulated with 6 mm thick closed cell elastomeric nitrile rubber insulation complete as per specification. 25 mm dia ID

100

20200

202

... More
Outdoor stand fabrication :- Supply, fabrication and erection of angle/channel/flat iron stand, hanging arrangement for air conditioning machines & ducts etc, back /support clamps or other similar work etc. including nut bolts of required size, making holes, fabrication, welding, cutting, etc. and painting with one coat of red oxide paint & two coat of enamel paint as required as per specification.

300

25500

85



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.