Awadhesh Pratap Singh University Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Awadhesh Pratap Singh University - APSU Tender

Works
Civil And Construction
Eprocure
Opening Date7 Feb 2020
Closing Date25 Feb 2020
Tender Amount₹ 36,06,438 
Notes
Download

Costs

  • EMD

    ₹ 50,000
  • Document Cost

    ₹ 5,000
  • Tender Fee

    ₹ 426

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.

20.95

-

-

... More
Providing half brick masonary with well burnt chimney bricks in bull patent trench klin crushing strength not less than 25 kg /cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level Cement mortar 1:3 (1 cement : 3 sand)

26.27

-

-

... More
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement : 4 sand)

190

-

-

... More
Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead : 1:4 (1 cement : 4 sand)

1160.25

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for : Weather shade, Chajjas, corbels etc., including edges.

187

-

-

... More
Brick work with well burnt chimney bricks in bulls patent trench kiln manufactured by ghol process ,crushing strength not less than 40kg /cm2 and water absorption not more than 15% in superstructure above plinth level and up to floor two level i/c curing etc complete. Cement mortar 1:6 (1 cement : 6 sand)

2.54

-

-

... More
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete

5772

-

-

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, Like birla white /JK white or equivalent, over the plastered wall surface to prepare the surface even and smooth i/c all cost of material, labour and scaffold etc in all position complete.

4576

-

-

... More
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work

5772

-

-

... More
Providing and laying vitrified floor tiles in different sizes with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 sand) including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600x9-10 mm

1082

-

-

... More
6 mm cement plaster 1:3 (1 cement : 3 sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams.

1393

-

-

... More
Providing and fixing unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes for working pressure of 4 kg/sqcm. 110 mm diameter (minimum wall thickness 3.2mm)

200

-

-

... More
Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 110mm bend

20

-

-

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.

427

-

-

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

1130

-

-

... More
Point wiring (excluding metallic switch box & sheet but including switches,sockes,lamp,holders,ceiling roses etc) with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for :- Light Point/Fan Points. a) Short point

60

-

-

... More
b) Medium point

130

-

-

... More
c) Long point

110

-

-

... More
Twin Control light points b) Medium point

6

-

-

... More
Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp. Socket outlet point with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit with required materials as per specification on same board .

33

-

-

... More
Wiring for circuit wiring with PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) of ISI marked suitable size etc. as required as per specification a) 2x2.5 Sq.mm.

417

-

-

... More
b) 4x2.5 Sq.mm.

256

-

-

... More
Point wiring (excluding metallic switch box & sheet ) for 3 Pin 16 Amp. Socket Outlet Point With 4 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in Concealed rigid P.V.C Conduit (HMS) ISI Marked of suitable size etc. with 16 Amp. F.T. Switch & Socket / S.S.Combined 6/16 Amp. of ISI Marked and 4 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit as per specification for New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution. C. Long Point

6

-

-

... More
D. Extra Long –I

8

-

-

... More
E. Extra Long –II

5

-

-

... More
F. Extra Long –III

3

-

-

... More
Same board switch socket 6/16 Amp

10

-

-

... More
Supplying and fixing of approved make modular type metal box with modular frame/ base plate and cover plate including fixing in concealed / surface excluding switch,socket etc. as required for:- 4 Module

12

-

-

... More
6 Module

23

-

-

... More
8 / 9 Module

29

-

-

... More
Supplying and fixing of approved make modular type P.V.C. box with modular base and cover plate including fixing on surface excluding switch,socket etc. as required for:- 4 Module

12

-

-

... More
6 Module

23

-

-

... More
8 / 9 Module

29

-

-

... More
3 1/2 WIRE SUB MAIN c) 3 x 6.0 + 1 x 4.0 sq mm cable in 25 mm conduit

87

-

-

... More
d) 3 x 10.0 + 1 x 6.0 sq mm cable in 25 mm conduit

103

-

-

... More
Supplying of metal clad ISI Marked bus bar chamber made of heavy gauge iron sheet complete with copper strip and bus bar supports as per specification confirming to IS -4064100 AMP 415 VOLTS, 4 way

4

-

-

... More
Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of 'C' series suitable for 240/415 Volts, 50 Cycle , 10 kA Value AC supply confirming to IS : 8828 : 1996, IEC : 60898 :2002 but without enclosures :- 6 Amp to 32 Amp Rating

48

-

-

... More
50 Amp to 63 Amp Rating

13

-

-

... More
Supplying of MCB Isolators suitable for 240/415 Volts, 50 Hz AC supply with KA value rating 10 kA of approved make confirming to IS :13947-Part III : 1993 & IEC :60947- 3:2001 (without enclosures ) :- 100 Amps.

4

-

-

... More
Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of Bus bar, Neutral bar, Earth bar & two earth terminals etc. complete as per IS:13032( exclusive of MCB & isolator )- 4 way single door

4

-

-

... More
Supply & fixing of approved make Industrial type metal plug & socket, 3 pin (2P + E) conforming to IEC : 60309 -1&3 complete as per specification 20 Amps Plug only

12

-

-

... More
Supplying and fixing of approved make Resistance type Fan regulator including connection etc. as required on existing board

31

-

-

... More
Ceiling Fan ( ISI )-1400 mm Sweep

2

-

-

... More
Supplying, erection and testing of approved make 'Fresh Air Fan' AC 230-250 volts with connection and including frame bolt/Anchor hole fasteners etc. complete finished of approved as required 300mm sweep

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.