All India Institute Of Medical Sciences Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
All India Institute Of Medical Sciences - AIIMS Tender
Civil And Construction
Building Construction
Eprocure
Opening Date16 Sep 2024
Closing Date7 Oct 2024
Tender AmountRefer Documents
Costs
EMD
₹ 1,80,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_IMSBP_826250_1Bid Award Id
ViewTender No
07/NIT/EEC/ABEU /AIIMS/BPL/2024-25Tender Authority
All India Institute Of Medical Sciences ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Filling of existing earth into depression for foundation_columns
-
-
-
... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
-
-
-
... More
All kinds of soil.
145.4
-
-
... More
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up
to 50 m and lift up to 1.5 m.
-
-
-
... More
All kinds of soil
748
-
-
... More
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
748
-
-
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
-
-
-
... More
1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
22.68
-
-
... More
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources).
32.12
-
-
... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103
to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and
reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. (Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have
discretion to either re-design the mix or bear the cost of extra cement.)
-
-
-
... More
All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum
28.83
-
-
... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
-
-
-
... More
1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources)
4.16
-
-
... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
-
-
-
... More
Cement mortar 1:6 (1 cement : 6 coarse sand)
31.2
-
-
... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
-
-
-
... More
Thermo-Mechanically Treated bars of grade Fe-500D or more.
904.64
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for
-
-
-
... More
Foundations, footings, bases of columns, etc. for mass concrete
85.2
-
-
... More
Columns, Pillars, Piers, Abutments, Posts and Struts
47.7
-
-
... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers
47.84
-
-
... More
12 mm cement plaster of mix :
-
-
-
... More
1:6 (1 cement: 6 fine sand)
126.4
-
-
... More
15 mm cement plaster on the rough side of single or half brick wall of mix :
-
-
-
... More
1:6 (1 cement: 6 fine sand)
140.8
-
-
... More
Finishing Wall with textured exterior paint of required shade
-
-
-
... More
New work (Two or more coats appiled @ 3.28 kg/10 sqm) over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm
145.6
-
-
... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
-
-
-
... More
110 mm diameter
280
-
-
... More
Supply and unloading of stone aggregate (Royalty included) of following size with all labour, material and consumables including all lifts and lead anywhere in AIIMS Premises : Stone Aggregate (Single size) : 40 mm nominal size
44.18
-
-
... More
Supply and unloading of stone aggregate (Royalty included) of following size with all labour, material and consumables including all lifts and lead anywhere in AIIMS Premises : Stone Aggregate (Single size) : 20 mm nominal size
29.45
-
-
... More
Supply and unloading of stone aggregate (Royalty included) of following size with all labour, material and consumables including all lifts and lead anywhere in AIIMS Premises : Stone Aggregate (Single size) : 10 mm nominal size
23.56
-
-
... More
Supply and unloading of stone aggregate (Royalty included) of following size with all labour, material and consumables including all lifts and lead anywhere in AIIMS Premises : Crushed stone 2.36 mm to 12.5 mm size
11.78
-
-
... More
Supply and unloading of stone aggregate (Royalty included) of following size with all labour, material and consumables including all lifts and lead anywhere in AIIMS Premises : Stone dust
11.78
-
-
... More
Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/ vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density .
120.75
-
-
... More
Providing and laying of 50 mm Football Turf FIFA Pro Approved with PU adheshive, Backing double Layer Latex with triple layer protective coating of PU. Grass Pile Height 50mm, Pile Shape of the Yarn-Diamond / C-shape. Carpet Mass-2360 grams/sqm. Yarn per unit area- 8820, Guage/pile width 1.4mm, DTEX-14000 Test cycles in hours of play 80000 hrs, Bi-Colour Meter dark & 2 meter light ( Light Green & Dark Green dual colour), Backing stitch (AIG ZAG/ Straight) Roll Size 4 MTR x 25 MTR/ 4 MTR x 30 MTR, Rubber Infilling (500 grams/per sqft) Silica Sand Infilling (2.5kg/ per sqft) All complete as per directioon of Engineer-in-charge.
589
-
-
... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
-
-
-
... More
Hot finished seamless type tubes
14500
-
-
... More
Supply and installation of green colored nets of 2.5 MM BRAIDED 50 MM MESH SINGLE LAYER on vertical surface with all labour,material and consumables Border & Tie Cord Rope : 12 mm @ Inside Twine Dia : 2.5 mm HDPE Twine (100 Kgf) @ Mesh Size - 50mm x 50mm Square.
@ Fabricating - Heat treated machine made knotting
@ Tie Rope & Tie Cord - As per site condition to make the safety net tight and strethced without any sagging (beyond persmissible by codes) or loosening. @ Standard/ Approved – P.P. Rope confirming to IS:14929 & Safety Net Made as per EN:1263 Part 1 and 2
(Test certificate of nets to be provided at the time of execution)
800
-
-
... More
Providing & installation of foam padding (25mm high density foam for cushion + high & quality PVC coated rexine for cover including chain & runner
250
-
-
... More
Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge)0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
840.4
-
-
... More
Providing and fixing precoated galvanised steel sheet roofingaccessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
-
-
-
... More
Ridges plain (500 - 600mm)
39.6
-
-
... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved makeconforming to IS: 733 and IS: 1285, fixing with dash fasteners ofrequired dia and size, including necessary filling up the gaps atjunctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rustfree, straight, mitred and jointed mechanically wherever requiredincluding cleat angle, Aluminium snap beading for glazing / paneling,C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
-
-
-
... More
For fixed portion Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)
30
-
-
... More
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)
25
-
-
... More
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windowsshutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-in-charge
-
-
-
... More
Pre-laminated particle board with decorative laminationon one side and balancing lamination on other side
5
-
-
... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall bepaid in basic item):
-
-
-
... More
With float glass panes of 5.50 mm thickness
5
-
-
... More
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors,embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.
-
-
-
... More
With stainless steel cover plate minimum 3.00 mm thickness
1
-
-
... More
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
2
-
-
... More
Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in- charge
-
-
-
... More
Polyester powder coated minimum thickness 50 micron
2
-
-
... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of
approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints
with white cement and matching pigments etc., complete.
-
-
-
... More
Size of Tile 600x600 mm for store room
12
-
-
... More
Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in :
-
-
-
... More
Cement mortar 1:6 (1 cement : 6 Coarse sand) for store room
9.81
-
-
... More
Providing, laying and fixing following dia G.I. pipe (medium class) in ground /road cutting complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required
-
-
-
... More
100 mm dia
40
-
-
... More
Supply and Laying of following size Aluminum conductor armoured , one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
-
-
-
... More
3.5X185 SQMM
150
-
-
... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
-
-
-
... More
120 mm dia (OD-120 mm & ID-103 mm nominal)
200
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
-
-
-
... More
3½ X 185 sq. mm (57mm)
4
-
-
... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
2
-
-
... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
130
-
-
... More
Supply and Laying of following size Aluminum conductor armoured , one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
-
-
-
... More
3.5X35 SQMM
70
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
-
-
-
... More
3½ X 35 sq. mm (32mm)
12
-
-
... More
Supply, installation,testing,commissioning Electrical LT indoor panel following .
-
-
-
... More
Out door PANEL DESCRIPTION AS PER "ANNEXURE A"
1
-
-
... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
2
-
-
... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm
50
-
-
... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
-
-
-
... More
Group C
45
-
-
... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
200
-
-
... More
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
150
-
-
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
-
-
-
... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
250
-
-
... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
250
-
-
... More
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
100
-
-
... More
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
170
-
-
... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
10
-
-
... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
15
-
-
... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
51
-
-
... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings)
10
-
-
... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
-
-
-
... More
8 way (4 + 24), Double door
4
-
-
... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
... More
Single pole
70
-
-
... More
Single pole and neutral
6
-
-
... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
... More
40 A
9
-
-
... More
63 A
3
-
-
... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required
-
-
-
... More
40 A
3
-
-
... More
63 A
1
-
-
... More
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required
3
-
-
... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
61
-
-
... More
SITC of highbay Led light sutaible for sports hall with minimum power 125 watt ,minimum luminous efficacy 160 lm/w,CRI =70,beam angle of light source 60 degreeor better ,mimimum color temperature 5700 k,input voltage 120 to 277 V,50Hz , mimimum Power factor (fraction) 0.90,optical cover type is micro lens optic in polycarbonate cover or better,housing material aluminium pressure die cast, pressure die cast aluminum material, IP 65 or better ,minimum life is 50,000 hours,wit all nesseary material like junction box, nut bolt, etc material .