Airports Authority Of India Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Airports Authority Of India - AAI Tender
Civil And Construction
Building Construction
Eprocure
Opening Date17 Oct 2024
Closing Date7 Nov 2024
Tender Amount₹ 67,47,718
Costs
EMD
₹ 1,35,000Document Cost
₹ 1,120Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_AAI_208426_1Bid Award Id
ViewTender No
AAI/BPL/ENGG(E)/NIT-09/2024-25Tender Authority
Airports Authority Of India ViewPurchaser Address
-Website
http://https://www.aai.aero/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
1.50 TR
6
-
-
... More
2.00 TR
2
-
-
... More
Indoor VRV/VRF Units (Nominal Capacity) - Hi wall type Unit.
Supply, installation, testing and commissioning of following minimum VRV/VRF Hi wall Type Indoor unit equipped with synthetic washable media pre- filter, fan section with low noise fan/dynamically balanced blower, multi speed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, necessary supports, cordless remote control etc., suitable for operation on single phase 230V±10%, 50 Hz AC supply, complete as required.
-
-
-
... More
1.50 TR
6
-
-
... More
2.00 TR
8
-
-
... More
Supply, Installation, Testing and Commissioning of DIRECT EXPANSION MICROPROCESSOR BASED PRECISION A/C UNITS complete with All four sides doubled skin sandwich panels with A1 class insulation, air cooled condenser with independent casing and stepless variable speed fans for winter operation for each circuit, Brushless DC Inverter based scroll compressor with its evaporator coil with hydrophilic coating, Electronically commuted brushless motor Backward curved Plug fan, Electronic Expansion Valve, first fill of environment friendly refrigerant (R410a), variable capacity auto-modulating humidifier and vibration isolator. Motor shall be suitable for 415 + 10% volts IE 3, 50 cycles, 3 phase AC supply and external static pressure shall be 20 Pa. Outdoor unit motor protection should be with IP-54 protection and should be weather proof. PAC shall be bottom throw. Auto sequencing of the unit for equal run time should be integral part of the micro-processor.
Each unit shall be complete with powder coated electrical panel and double earthing. The cables should be Cross linked polythene insulated, armoured Copper cabling and all termination between main panel and PAC. Timers shall be provided in Electrical panel for delayed start of units. For each unit installation price shall be inclusive of First Charge of Refrigerant, Lifting shifting to the designated floor, Power cabling from MCB to indoor unit upto 10 RMT per unit, Powder coated Adjustable Height Indoor Stand and outdoor MS stand for Outdoor condenser, Commissioning of the unit. Each unit shall have inbuilt sequential controller for operating unit in N+1 confguration. Microprocessor should have inbuilt features of Team Mode and cascade mode incase required. Indoor unit capacity and Condensers should be adequately sized for return Air temperature as per specification.
-
-
-
... More
5.50 TR
5
-
-
... More
Supply Installation, testing and commissioning of Y-joints of suitable size as per site requirements.
25
-
-
... More
Supply, Installation, Testing and Commissioning U-PVC pipe with fittings of 10 kg /cm3 with 9 mm thick Nitrile rubber of Class "1" including all fittings and jointing with solvent cement and including cutting chieseling / holes in walls, wherever required and making good the same, complete as directed by the Engineer in charge.
-
-
-
... More
40 mm nominal dia Pipes
30
-
-
... More
32 mm nominal dia Pipes
60
-
-
... More
25 mm nominal dia Pipes
100
-
-
... More
Supply, Installation, Testing and Commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft / harddrawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquidlines, all accessories as per specifications etc. as required.
-
-
-
... More
38.10 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
50
-
-
... More
34.90 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
50
-
-
... More
31.60 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
50
-
-
... More
28.58 mm dia (OD) (Hard drawn) with tube thickness 1.20 mm with 19 mm thick insulation
75
-
-
... More
25.20 mm dia (OD) (Hard drawn) with tube thickness 1.20 mm with 19 mm thick insulation
100
-
-
... More
22.20 mm dia (OD) (Hard drawn) with tube thickness 1.20 mm with 19 mm thick insulation
100
-
-
... More
19.00 mm dia (OD) (Hard drawn) with tube thickness 1.20 mm with 19 mm thick insulation
100
-
-
... More
Supply & fixing of 25 mm Thick nitrile rubber Class O insulation for exposed roof area as shown in the drawings. Quoted price shall be inclusive of adhesive, two coat of primer, nut etc as required and as per the tender specifications.
250
-
-
... More
Supply, Installation, testing and Commissioning of Communication cable between indoor to outdoor 2C x 1.0 Sqmm Copper Shielded cable in medium class PVC Conduit Complete etc as required.
250
-
-
... More
Supplying and fixing of Pre wired 8 way (4 + 24), Double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.
1
-
-
... More
Supply of 4 Core X 10 Sq.mm sizes of Power Cables multi stranded Copper conductor, XLPE Insulated, cores laid up PVC tape / Extruded Inner sheath, Armour, FRLS at outer sheath, 1100V grade as per IS 7098 (Part 1) 1988 with upto date amendments.
200
-
-
... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
8
-
-
... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Four pole
4
-
-
... More
Supplying and fixing 63 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Four pole
1
-
-
... More
Supplying and fixing 63 A rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1
-
-