Airports Authority Of India Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Airports Authority Of India - AAI Tender
Civil And Construction
Building Construction
Eprocure
Opening Date5 May 2022
Closing Date2 Jun 2022
Tender Amount₹ 32,96,309
Costs
EMD
₹ 65,930Document Cost
₹ 1,120Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_AAI_114860_1Bid Award Id
ViewTender No
AAI/BPL/ENGG(E)/NIT-04/2022-23Tender Authority
Airports Authority Of India ViewPurchaser Address
-Website
http://https://www.aai.aero/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply, installation, testing and commissioning of following minimum capacity 4- way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (INDOOR UNIT-CASSETTE TYPE) 2.4 TR
1
-
-
Supply, installation, testing and commissioning of following minimum capacity 4- way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (INDOOR UNIT-CASSETTE TYPE) 2 TR
1
-
-
Supply, installation, testing and commissioning of following minimum capacity 4- way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (INDOOR UNIT-CASSETTE TYPE) 1.6 TR
2
-
-
Supply, installation, testing and commissioning of following minimum capacity 4- way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (INDOOR UNIT-CASSETTE TYPE) 1.2 TR
1
-
-
Supply, installation, testing and commissioning of following minimum capacity VRV / VRF Highwall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan / dynamically balanced blower, multi speed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cordless remote control, drainpan, necessary accessories etc., suitable for operation on 230V ± 10 %, 50Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.
(HIGH WALL TYPE) 1.45 TR
2
-
-
Supply, installation, testing and commissioning of following minimum capacity VRV / VRF Highwall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan / dynamically balanced blower, multi speed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cordless remote control, drainpan, necessary accessories etc., suitable for operation on 230V ± 10 %, 50Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.
(HIGH WALL TYPE) 1.3 TR
2
-
-
Supply, installation, testing and commissioning of following minimum capacity VRV / VRF Highwall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan / dynamically balanced blower, multi speed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cordless remote control, drainpan, necessary accessories etc., suitable for operation on 230V ± 10 %, 50Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.
(HIGH WALL TYPE) 1 TR
3
-
-
SITC of Seamless heavy gauge Copper refrigerant piping of adequate size duly insulated with nitrile insulation of adequate thickness. Refrigeration piping will have to be taken in the piping rack / Cable tray Support individually connecting to all indoor units for the respective floors. Even necessary supports, fittings, valves & ref. joints where ever required will be included.(Supply + Return) with 13mm thick insulation on liquid line & 19mm thick insulation sleeves on Suction Line)
125
-
-
Supply, installation, testing & commissioning of ref nut / Y-joints of brass for indoor and outdoor units for suitable size as per requirement.
For Outdoor Unit
1
-
-
Supply, installation, testing & commissioning of Ref nut / Y-joints of brass for indoor and outdoor units for suitable size as per requirement.
For Indoor Unit
18
-
-
Supply and fixing of drain piping in hard PVC with all fittings, supports and clamps, including drilling hole in wall to route the drain pipe with 6mm thick nitrile rubber insulation.- 25mm with 9mm nitrile tubes.
50
-
-
Supply and drawing Control Cable between the indoor units & outdoor units. 2C x 0.75 Sq.mm Shielded Braided PVC inner sheathed, copper conductor, communication cable from indoor to outdoor units & between central controller.
100
-
-
Supply, fabrication and installation at proposed location of MS base frame ( for VRF machine Out Door Unit).The same shall be fabricated form 100mm wide "C" channels & shall be painted with primer and black paint.
2
-
-