Airports Authority Of India Tender
Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Airports Authority Of India - AAI Tender
Civil And Construction
Eprocure
Opening Date8 Mar 2022
Closing Date28 Mar 2022
Tender Amount₹ 1,48,29,760 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 3,61,860Document Cost
₹ 1,180Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_AAI_108294_1Bid Award Id
ViewTender No
AAI/ID/ENGG(E)/eNIT-07/2021-22Tender Authority
Airports Authority Of India ViewPurchaser Address
-Website
http://https://www.aai.aero/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
For second Year
12
-
-
SH:II MAINTENANCE JOBS
-
-
-
Lifting and Lowering of Submersible Pump below ground level upto 450 ft including transportation,loading,unloading charges etc. complete as required.
-
-
-
3.0 HP (For First Year)
1
-
-
7.5 HP (For First Year)
2
-
-
10.0 HP (For First Year)
1
-
-
3.0 HP (For second Year)
1
-
-
7.5 HP (For second Year)
2
-
-
10.0 HP (For second Year)
1
-
-
Complete rewinding of the motor of following capacity Submersible pump including transportation,loading,unloading charges, replacement of bearing, greasing etc. complete as required.(DLP of the job shall be 6 months)
-
-
-
3.0 HP (For First Year)
1
-
-
7.5 HP (For First Year)
2
-
-
10.0 HP (For First Year)
1
-
-
3.0 HP (For second Year)
1
-
-
7.5 HP (For second Year)
2
-
-
10.0 HP (For second Year)
1
-
-
Complete rewinding of the motor of following capacity monoblock pump including transportation,loading,unloading charges, replacement of bearing, greasing etc. complete as required.(DLP of the job shall be 6 months)
-
-
-
3.0 HP (For First Year)
1
-
-
5.0 HP (For First Year)
1
-
-
10.0 HP (For First Year)
1
-
-
3.0 HP (For second Year)
1
-
-
5.0 HP (For second Year)
1
-
-
10.0 HP (For second Year)
1
-
-
Complete rewinding of ceiling/wall fan including transportation, loading, unloading charges, reinstallation etc. complete as required.
-
-
-
For First Year
35
-
-
For Second Year
35
-
-
Complete rewinding of following size exhaust fan including transportation, loading, unloading charges, reinstallation etc. complete as required.
-
-
-
up to 225 mm size (For First Year )
10
-
-
up to 450 mm size (For First Year )
10
-
-
up to 225 mm size (For second Year )
10
-
-
up to 450 mm size (For second Year )
10
-
-
Inspection, servicing and testing of oil circuit breaker of 3 Pole, 400A , 11 KV Oil Circuit Breaker of the HT panel (Make: Crompton Greaves) from Manufacturer or Authorised Service Dealer or Specialised Agency installed at Old power house alongwith submission of the test reports.
-
-
-
For First Year
3
-
-
For Second Year
3
-
-
Inspection, Servicing, Setting, Calibration and Testing of relay(2 nos. O/C relay & 1 no. E/F relay-3 Sets) of oil circuit breaker of 11 KV HT panel of old power house complete in all respect along with submission of test report.
-
-
-
For First Year
1
-
-
For Second Year
1
-
-
Dehydration and filtration of transformer oil at site includnig testing the BDV and acidity before and after testing and submission of test reports etc. as required for 750 KVA, 11/0.415 KV Transformers.
-
-
-
For First Year
2
-
-
For Second Year
2
-
-
Supply of transformer oil for topping up in transformers as required.
-
-
-
For First Year
100
-
-
For Second Year
100
-
-
Inspection, Servicing and Testing(all tests) of 750 KVA, 11/0.415 KV Transformers of old power house includes replacement of silica gel, rectification of any oil leakage etc. as required at site along with submission of test report.
-
-
-
For First Year
2
-
-
For Second Year
2
-
-
Inspection , Servicing and Testing of 100 KVA , 3.3 / 0.433 KV Dry Type Transformer i/c carrying out Insulation Test HT / LT side with Meggar , Voltage Ratio Test , Magnetic Balance Test , Tightning of Stamping , Removing of Moisture if Insulation value low and Insulation Testing of 3.3 KV HT Cable etc. as required at site.
-
-
-
For First Year
4
-
-
For Second Year
4
-
-
Painting of following poles in 2 coats by using Aluminium paint of approved make (Asian / Berger) including pole boxes, cleaning of surface etc., as required including rewriting the identification Sl.No.
-
-
-
80 mm Dia Gl pipe pole of length not exceeding 2 Mt.
480
-
-
Spray Painting of sheet metal enclosures of electrical panels / feeder pillars inside the power house, Pump room & ATC building including cleaning the surface and one coats of grey or any other color of make (Asian / Berger) including rewriting the identification the circuit, Protecting and covering the electrical accessories during painting and removing after work is over etc., as reqd.
50
-
-
SH:III EXECUTION OF WORKS AS PER CPWD SCHEDULE OF WORKS (E&M) 2018 AND SPECIFICATIONS AS AND WHEN REQUIRED.
-
-
-
Execution of works as per CPWD DSR (E&M) 2018, DAR (E&M) 2018 & Latest CPWD Specifications as & when required.
CPWD DSR (E&M) - Chapter 1 to 10 & 14
The rate shall be quoted for this item as per examples given below: -
Please refer SCC before quoting rates for this item.
• If Bidder wants to quote the rate at par with rates of DSR - 2018 (E&M), then bidder has to quote 1.00 in the rate column.
• If Bidder wants to quote the rate 10 % Above the rates of DSR - 2018 (E&M), then bidder has to quote 1.10 in the rate column.
• If Bidder wants to quote the rate 10 % Below the rates of DSR - 2018 (E&M), then bidder has to quote 0.90 in the rate column.
-
-
-
First Year
200000
-
-
Second Year
200000
-
-
SH:IV CMC of ACs, Water Coolers and Water Purifiers
-
-
-
Annual Comprehensive Maintenance Contract of the following Capacity AC units (including replacement of compressor & refilling of refrigerant) installed at various locations in the Airport Premises as per general and special terms and conditions attached.
-
-
-
1 TR Window/split Type AC Units ( For First year )
18
-
-
1.5 TR/ 2.0 TR Window/split Type AC Units ( For First year )
48
-
-
3.0 TR Split/Cassette Type AC Units ( For First year )
15
-
-
1 TR Window/split Type AC Units ( For Second year )
18
-
-
1.5 TR/ 2.0 TR Window/split Type AC Units ( For Second year )
48
-
-
3.0 TR Split/Cassette Type AC Units ( For Second year )
15
-
-
Annual Comprehensive Maintenance Contract of the following Capacity AC units( excluding compressor but including refilling of refrigerant) installed at various locations in the Airport Premises as per general and special terms and conditions attached.
-
-
-
1 TR Window/split Type AC Units ( For First year )
5
-
-
1.5 TR/ 2.0 TR Window/split Type AC Units ( For First year )
34
-
-
3.0 TR Split/Cassette Type AC Units ( For First year )
9
-
-
1 TR Window/split Type AC Units (For Second Year )
5
-
-
1.5 TR/ 2.0 TR Window/split Type AC Units (For Second Year )
34
-
-
3.0 TR Split/Cassette Type AC Units (For Second Year )
9
-
-
Annual Comprehensive Maintenance Contract of the following Capacity Conventional Type Water Coolers (excluding compressor but including refilling of refrigerant) installed at various locations in the Airport Premises as per general and special terms and conditions attached.
-
-
-
Water Coolers of 80 Ltrs capacity (For First Year)
6
-
-
Water Coolers of 80 Ltrs capacity (For Second Year)
6
-
-
Annual Comprehensive Maintenance Contract of the following Capacity Conventional Type Water Coolers (including replacement of compressor & refilling of refrigerant) installed at various locations in the Airport Premises as per general and special terms and conditions attached.
-
-
-
Water Coolers of 80 Ltrs capacity (For First Year)
7
-
-
Water Coolers of 80 Ltrs capacity (For Second Year)
7
-
-
Supply and fixing of suitable size copper refrigerant piping with expanded polythene foam insulation tubing covering for A/C units.
50
-
-
Annual comprehensive maintenance & repair including attending preventive & breakdown maintenance of following Water Purifiers (with and without integral chiller units) by deputing authorized service dealer of RO/UVwater purifiers of different makes & capacities, installed at different places including replacement of filter cartridge, RO Membrane, carbon filter & defective parts/PVC pipes/Iron clamps, internal filter elements etc. with same company make spares including arresting the leaks etc. as required.
-
-
-
CMC of 10 Ltr Storage RO filter Cum UV water Purifier of make Eureka Forbes Model : Aquaguard Reviva RO+ UV with all accessories for providing drinking, complete as required.
-
-
-
For First Year
1
-
-
For Second Year
1
-
-
CMC of Hot and Cool type RO water filter Cum UV Purifier of make Eureka Forbes Model : Aquaguard RO+ UV with all accessoriesfor providing drinking water complete as required.
-
-
-
For First Year
1
-
-
For Second Year
1
-
-
CMC of the Aquaguard Pure Chill 60/80 UV Water Cooler cum purifier, make : Eureka Forbes, including replacement of compressor, filters, PCB, pumps/motors, U.V. Lamp etc. as per breakdown / preventive maintenance requirement.
-
-
-
For First Year
2
-
-
For Second Year
2
-
-
CMC of Cooler cum Purifier of capacity 40 LPH, 3 stage purification, make : Eureka Forbes, model: Aquaguard AGCCP, Including replacement of Filters(pre filter & carbon filter), Solinoied Valve, PCB, U.V.Lamp etc. as per breakdown maintenance requirement.
-
-
-
For First Year
4
-
-
For Second Year
4
-
-
CMC of Purifier of make : Eureka Forbes, model: Aquaguard AG -200, Including replacement of Filters(pre filter & carbon filter), Solinoied Valve, PCB, U.V.Lamp etc. as per breakdown maintenance requirement.
-
-
-
For First Year
5
-
-
For Second Year
5
-
-
CMC of 25 LPH capacity RO+UV+UF water Purifier of make: Kent, Model :Elite Plus, with all accessories for providing drinking water, complete as required.
-
-
-
For First Year
3
-
-
For Second Year
3
-
-
CMC of 50 LPH capacity RO+UV+UF water Purifier of make: Kent, Model :Elite Plus, with all accessories for providing drinking water, complete as required.
-
-
-
For First Year
8
-
-
For Second Year
8
-
-
CMC of 40 LPH capacity RO filter Cum UV water Purifier of make: Kent, Model :Elite, with all accessories for providing drinking water, complete as required.
-
-
-
For First Year
2
-
-
For Second Year
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements