Airports Authority Of India Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Airports Authority Of India - AAI Tender

Works
Electrical Cables And Wires
Electrical and Electronics
Eprocure
Opening Date10 Jun 2022
Closing Date1 Jul 2022
Tender Amount₹ 23,85,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Laying of 1 no. 63 mm dia OD DWC Pipe along with all accessories like sockets, bends, couplers etc. complete with fitting, cutting and jointing etc. direct in ground including excavation, trenching (80 cm below ground level, for HT cable) and refilling the trench but excluding sand cushioning and protective covering etc. complete as required. (Only DWC pipe shall be provided by AAI and all above accessories shall be in the scope of the contractor).

175

-

-

... More
Laying of 1 no. 63 mm dia OD DWC Pipe along with all accessories like sockets, bends, couplers etc. complete with fitting, cutting and jointing etc. direct in ground including excavation, trenching (75 cm below ground level, for LT cable) and refilling the trench but excluding sand cushioning and protective covering etc. complete as required. (Only DWC pipe shall be provided by AAI and all above accessories shall be in the scope of the contractor).

1400

-

-

... More
Laying of 1 no. 63 mm dia OD DWC Pipe along with all accessories like sockets, bends, couplers etc. complete with fitting, cutting and jointing etc. in existing culvert duly clamped (clamped with 25x3mm MS flat clamp) on its wall etc. complete as required. (Only DWC pipe shall be provided by AAI and all above accessories shall be in the scope of the contractor).

1225

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on surface of wall/ culvert etc. as required.

-

-

-

... More
Upto 35 sq. mm. (clamped with 1mm thick saddle)

125

-

-

... More
Above 95 sq. mm and upto 185 sq. mm. (clamped with 25/40x3mm MS flat clamp)

2600

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 3.3 KV grade of 3 core x 35 sq.mm.size in the existing RCC/ HUME/ METAL/HDPE/ DWC pipe as required.

1275

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/ HDPE/ DWC pipe as required.

-

-

-

... More
Upto 35 sq. mm.

250

-

-

... More
Above 95 sq. mm and upto 185 sq. mm.

3300

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 3.3 KV grade of 3 Core x 35 Sq. mm. size in the existing masonry open duct as required.

15

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.

-

-

-

... More
Above 95 sq. mm and upto 185 sq. mm.

40

-

-

... More
Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres as required.

50

-

-

... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 3 core x 35 sq.mm. size, XLPE aluminium conductor cable of 3.3 KV grade as required.

1

-

-

... More
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for 3 Core x 35 Sq.mm. size, XLPE aluminium conductor cable of 3.3 KV grade as required.

3

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
4 X 16 sq. mm (28mm)

4

-

-

... More
3½ X 120 sq. mm (45mm)

4

-

-

... More
3½ X 185 sq. mm (57mm)

4

-

-

... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
3½ X 120 sq. mm (45mm)

5

-

-

... More
3½ X 185 sq. mm (57mm)

4

-

-

... More
Installation of Feeder Pillar on ground by excavating the earth and providing PCC (1:2:4) pedestal (foundation) of size 800 mm. x 500 mm. x 450 mm. (depth) alongwith making suitable provision for cable entry/ exit in the pedestal and refilling the earth etc. as required.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.