Public Works Department Tender
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
₹ 93,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_PWD_5977_1Tender No
E Tender No 296 of RnB Division LehTender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://jkpwdrb.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) incl. carriage complete job.
11.25
-
-
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:1½:3 (1 cement :1½ coarse sand: 3 graded stone aggregate 20 mm nominal size) incl. carriage complete job.
10
-
-
Centring and shuttering including strutting propping etc. and removal of form for Lintels, beams, plinth beams etc.
80
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo mechanically Treated bars incl. carriage complete job.
1500
-
-
Supply and fixing of Tibeten style shingtsag wood carving of 2 feet wide & in required length hanged over windows complte.
25
-
-
Structurel steel work rived bolted or welded in built u sections trusses and framed work including cutting hoisting fixing in position and applying a priming coat of approved steel primer & two coat of synthatic enamal paint all complete sectio
4918.3
-
-
Providing and fixing mild round holding down bolts with nuts and providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
150
-
-
Providing and fixing factory made single leaf 40mm thick puf panel insulated off white colour with powder coated MS frame fixed with lock kundi arrangment complete.
6.72
-
-
Installation: The door shall be truly in plumb and water level and installed using steel fasteners with in outer frames duly covered with fastener caps The outer frame of door shall be sealed with silicone based sealants from outside and sealant from inside installtion shallbe done by skilled workers supervised by Engineer in charge. Other Arrangment The outer frame and shutter frame shall have provision for lock and key all complete in the pattren as per direction of Engineer in charge. Rate and measurements. Cost of the items includes supplying installation and fixing of door. frame with all fittings and fixture locking arragnements, handles all complete as per above inclusivve of elements of labour tools lifting m achines etc. cost of sealemnt fasteners, screws sleeves, spacers, protective tape, masking tape, fixture scaffolding complete in all respect a nd as per direction of Engineer-in-charge for calculating area of the door for payment outer to outer dimentions of width and height of door frame shallbe measured upto centimeter and area shall be calculated upto two place of decimels in square meter. Double leaf 40,mm thick puf panel complete as off white colour coated door with MS frame matching to specification same as sr. No 11
3.36
-
-
Providing and fixing 30mm thick false ceiling countinous line puf panel with fixing accessories complete on ground floor & 1st floor level for all heights as per specifictions drawing and as directed by engineer-in-charge Lloyd sand wich PUF panel comprising of on two faces PPGL (galvalume) colour coated 0.5mm TCT sheet and CFC freeclose cell High density rigid polyurethane foam of high density (40+2 kg/m3 ) having at thermal conductivity value of 0.023 w/mk and of required thickness sandwiched between the two galvalue sheets. The outer amd inner galvalue sheet of 0.50 mm TCT steel 550 Mpa shall have a coating mass of 150g/sqm zinc aluminiyuum a alloy coating total of both sides as per AS-1397 and finished with 20micron colour coating of SMP polyester utility paint as per AS/NZS 2728:1997 (category-3) over a 5 microns primer on exposed side and a back coat of 5 microns on inner side over a 5 micromn primer The panels should be of required lenght and required width with miximum width upto 1190 mm with tongue and groved configuration. For false ceiling panel & wall Panel with 50mm thick finished with 0.50 mm thick TCT Galvalume plane sheet with plain sheet on both side with tongue & groove system arrangment complete including fixing accessories fasteners etc. as per direction of Engineer-in-charge.
84
-
-
Providing and fixing factory made aluminium powder coated white colour fixed or double leaf casement window with 5mm thick transparent glass windows & Louver type metal colour coated ventilator complete.
2
-
-
Providing and fixing factory made Un-pleasticized Poly vinyl chloride (UPVC) 21mm thick-DGU window white colour fixed or casement windows complete Frame made of lead free extruded UPVC chambered profile customized in required size & window frame shall be mitred cut and jointed with machine welding, including providing & fixing hinges to the frame and shutter fixing the fame with jamb with required number and sizes of dash fastener of approved quality alll complete to achieve smooth functioning of window and shutter including making provision for all fittings and fixing at site and sealing of gaps as per the design & specification all complete. (i) shutter: Factory made UPVC-21mm thick DGU window shutter with window (fixed/openable) profiles. The outer profile frame of required size shall be mitered cut and joint at the corner by means of welding providing and fixing required toughned glass 5mm thick and UPVC snap fit beads co-extruded with EPDM gasket all of required size and section all complete as per manufacture specification complete. Hardware: the profile section shall be using locking mechanism and butt hinges and othe suitable handle & fixtures. installation : The window shall be truly in plumb and level and installed in the Puf sandwich panel opening using approved quality steel fastner with step-drill holes (13/8mm) in outer frames duly cover with fastener caps. The outer frame of window and sill must be sealed with silicone based sealants from outside and acrylic paintable sealant from inside. Other arrangement The outer frame and shutter frame must have provision for drainage including all necessary hardware fittings ie. handle with lock and key all complete. Rate and Measurement Cost of the item includes sypplying installation and fixing of UPVC windows frame shutter with glass and all fitting & fixture lacking arrngment and handle alll complete as above inclusive of elements of labour tools liftings machines etc. cost of sealant fasteners screws, sleeves, spacers proteective tape, masking tape, bolts gasket fixture, scaffolding etc. complete in all respect. for calculating area of the window for payment outer to outer dimentions of width and height of window frame shall be measured upto centimeter and area shallbe calculated upto two places of decimile in square meter. UPVC -21mm thick DGU window (size 1.5mtrx1mtr) with frame including double shutters or fixed with 5mm frosted toughened glass
20
-
-
Lauver type ventilator made with color coated metel sheet complete.
7.02
-
-
Providing and installing prefabricated sandwich PUF panel comprising of on two faces PPGL (galvalume) colour coated 0.5mm TCT sheet and CFC freeclose cell, high density rigid polyurethane foam of high density(40+2kg/m3) h aving a thermal conductivity value of 0.023 w/mk and of required thickness sandwiched between the two galvaue sheets. The outer and inner galvalue sheet of 0.50 mm TCT steel 550 mpa shall have a coating mass of 150g/sqm zinc aluminium a alloy coating total ofboth sides as per AS-1397 and finished with 20 micron colour coating of SMP polyester utility paint as per AS/NZS2728:1997 (categor-3) over a 5 micron primer on exposed side and a back coat of 5 micron on inner side over a 5 micron primer. The panel should be of required length and required width with mazximum width upto 1190 mm with tongue and groove configuration. The prefabricated panel shall be fixed directly to the grith using self drilling fasteners. The metel sheet shall conform to IS: 513 AS -1397&2728 The polyurethane insulation shall conform to IS : 12436 the rate include cost of flashing/ridges/corner pieces/hips etc made of 0.5mm TCT PPGL Steel sheet in required shape and size including all accessories required to complete the work The rate of the item is inclusive of all materials, erection accessories incidential charges cost of dash fasteners etc. Cost of making provision of doors windows ventilators. and conceeled pipes conduits and support for electrical sanitary appliances etc and other incidental charges as per sampl;e. For payment finished puf sand wich panel shallbe measured upto half centimeters for calculating area upto two places of decmal. No deduction shall be made for opening upto 0.20sqm and no extra payment shall be made for wastages. For wall Partition panel with 100mm thick wall panel finished with 0.50 mm thick TCT Galvalume plain sheet with f small ribs on both sides with tongue & groove arrangment complete including fixing accessories such as as per direction of Engineer-jn-charge (1800+200= 2000)
553.58
-
-
For roof panel with 30 (30/70)mm thick roofing panels having finished with 0.50mm thick TCT Galvalume Hi-rib shet on outer side and 0.50mm TCT palin Galvalume sheet on inner side including accessories such as dash fasteners etc.
84
-
-
For roof panel with 30 (30/70)mm thick roofing panels having finished with 0.50mm thick TCT Galvalume Hi-rib shet on outer side and 0.50mm TCT palin Galvalume sheet on inner side including accessories such as dash fasteners etc.
487.6
-
-
Providing and fixing flashings C-channel wall corners, base channe etc. made of 0.50mm TCT color coated galvalume stel sheet in required shape & size complete as per direction of Engineer-in-charge.
274
-
-
Supply and Installation of synthetic PVC vinyl flooriung 6mm thick with under 5mm foam over existing PCC floor complete the synthetic PVC vinyl flooring wil be provided with game line marking The PVC vinyl flooring will be available in 15mtr length & 1.8mtr width in green colour & fixed at site with required adhesives complete.
75
-
-
P/F ceramic floor /wall tile in toilet area complete
3.71
-
-
P/F internal sanitry/plumbing fitting complete in one toilet each toilet have 1no western type pot with plastic cistern arangment 1no washbashin 2no taps with internal UPVC piping fitting compete toilet area in connected to 1000 ltr pvc double layer water tank placed over toilet area complete two no additional washiable with taps & UPVC piping is fixed in toilet area conplete as per engineer in charge
1
-
-
Providing and fixing internal and external electrical work with solar fitting complete as direction by engineer in charge.
1
-
-