Public Works Department Tender

Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.

Public Works Department - PWD Tender

Works
Eprocure
Opening Date20 Sep 2024
Closing Date24 Sep 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Random Rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6 (1 Cement : 6 coarse sand ) upto plinth level and curing complete with: fire tank

58.8

-

-

... More
Providing & fixing upto floor five level precast cement concrete solid blocks including hoisting and setting in position in cement mortar 1:3 (1cement:3 coarse sand), cost of required centring, shuttering and curing complete. 1:3:6 (1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20 mm nominal size) fire tank

8.4

-

-

... More
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) fire tank

6

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. fire tank and cover

900

-

-

... More
Suspended floors, Roofs, Landings, Balconies and Access Platforms.

42

-

-

... More
12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand) fire tank

154

-

-

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. of make Jaguar/Hindware/Grohe or equivalent as per instruction of Site Incharge fire tank

154

-

-

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete.Size of Tile 600 x 600

112.95

-

-

... More
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require of make Jaguar/Hindware/Grohe or equivalent as per instruction of Site Incharge

20

-

-

... More
Providing and fixing white vitreous china pedestal type water closet (Indian W.C. pan) , 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require of make Jaguar/Hindware/Grohe or equivalent as per instruction of Site Incharge

10

-

-

... More
Vitreous china pedestal for wash basin of make Jaguar/Hindware/Grohe or equivalent as per instruction of Site Incharge

26

-

-

... More
Providing and fixing 630 x 450 mm counter top wash basin with necessary fising - Vitreous China of make Jaguar/Hindware/Grohe or equivalent as per instruction of Site Incharge

26

-

-

... More
Mirror of superior make glass of size 75x60 cm with diamond edge cut

26

-

-

... More
Providing and fixing Micro cellular rubber tubes with Heat cable of self regulating heat trace heating cable upto 80 degrees foiled with aluminium foil and PPR/ PVC pipes with Resin bonded glass wool @ 24 kg / cum., 50 mm thick sqm 143.00 including cost of wire/tape to fix the wool on pipes covered with chicken mesh of size 20x20mm on resin glass wool and fixing aluminum sheet on resin bonded glass wool to prevent heat loss as per approval of Site Engineer.

460

-

-

... More
Providing and fixing aluminum sheet on resin bonded glass wool to prevent heat loss in surrounding area.

460

-

-

... More
Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931

30

-

-

... More
Providing and fixing 15 mm nominal bore C.P. stop cock (concealed) of standard design and of approved make conforming to IS : 8931

30

-

-

... More
Providing and fixing 15 mm nominal bore C.P. brass 2 in 1 angle valve for basin mixer and geyser points of approved make conforming to IS : 8931

30

-

-

... More
Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931

30

-

-

... More
Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg.

24

-

-

... More
C.P. brass Toilet paper holder of standard size

23

-

-

... More
Providing and fixing SS rectangular Shower head of size 150 x 150mm of any approved make with complete jointing and fixing all complete job

27

-

-

... More
Providing and fixing SS high flow Diverter of any approved make with complete jointing and fixing all complete job

28

-

-

... More
Providing and fixing Jet Spray Health Faucet in Polished chrome inclduding pipe holder, tape all conforming to IS.of make Jaguar/Hindware/Grohe or equivalent as per instruction of Site Incharge

30

-

-

... More
Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms. of make Jaguar/Hindware/Grohe or equivalent as per instruction of Site Incharge

28

-

-

... More
Towel rail C.P. brass 600 x20 mm together with a pair of C.P. brass brackets to fit the size of towel rail all complet job of make Jaguar/Hindware/Grohe or equivalent as per instruction of Site Incharge

28

-

-

... More
Rectangular shape 600x600 mm precast R.C.C. manhole cover.

8

-

-

... More
Supplying ...litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside Fiber body outside, filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. ( Five star with Fibre body, 25L)

30

-

-

... More
Providing and fixing FRP water PUF insulated water storage tank( Minimum 75 mm thick PUF Insulation including PCC platform of required size all complete JOB (1000 Litre Tank)

14

-

-

... More
Providing and fixing three phase hydro pnumetic pumping system, Ss frequency 50 Hz, min speed 2900 rpm Water Supply Hydro Pneumatic System, 415 V , including cost of claps, cuppling, PCC Platform etc all complete job as per approval of site incharge.

4

-

-

... More
Providing and fixing 500 Ltr capacity solar Water heater of approved make placed on terrace including fixing, interconnection of the supply line with insulated PPR pipes of required size of make Tata Power solar system/Indo solar/V-guard or equivalent as per approval of site incharge

14

-

-

... More
Finishing walls with textured interior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm in dining hall and common room

120

-

-

... More
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 2.50 sqm (Trombe Wall)

447

-

-

... More
Providing and fixing double glazed hermetically sealed glazing in aluminum windows, ventilators and partition etc. with 6mm thick clear float glass both side having 12mm air gap including providing EPDM gasket, perforated aluminum spacers, desiccants, silicon sealant (both primary and secondary sealant) etc. as per specifications, drawings and directions of Engineer-in-charge complete.

447

-

-

... More
Sectional steel work to support UPVC walls / windows. Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.1 Hot finished welded type tubes

2500

-

-

... More
WOODEN FLOORING Wooden planking, tongued and grooved in flooring including fixing with iron screws complete: 11.43.1 12 mm thick

950

-

-

... More
Providing and fixing wooden railing including ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc. Stairs

320

-

-

... More
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Ramp

180

-

-

... More
Providing and fixing thermal insulation of ceiling (under deck insulation) with specified glass wool conforming to IS: 8183, 50mm thick, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3mm) @ 60cm c/c and wire mesh of 12.5mm x 24g wire for top .With resin bonded rock wool with density 48 Kg/Cum

1100

-

-

... More
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 11.68.1 Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. mess, kitchen, terrace, porch, skirting, basement

930

-

-

... More
Providing and laying in situ seven course water proofing treatment with APP (Atactic poly- propylene) modified Polymeric membrane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/ sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS: 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane of specified thickness, weight and centre core, HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement:3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement: 3 fine sand) an 14.85.2 Modified Polymeric membrane 2.0 mm thick of 3.0 Kg/ sqm weight consisting of five layers prefabricated with centre core as 100 micron

1100

-

-

... More
Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. 110 mm diametre

250

-

-

... More
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge

900

-

-

... More
Providing and fixing Brass Door Handle lock of any approved make like Goodrej or Equivalent to all Rooms and bathrooms including necessary screqs and bolts, complete job

128

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges ,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 25 mm dia.

14

-

-

... More
100 mm dia.

32

-

-

... More
150 mm dia.

55

-

-

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : 150 mm dia

1

-

-

... More
100 mm dia

2

-

-

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore

2

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 150 mm dia

1

-

-

... More
100 mm dia

2

-

-

... More
Providing and fixing dial type pressure gauge with isolation cock and copper pipe at hydrant station. Dial diameter 100 mm calibration 0-15 kg/ sq.cm.

7

-

-

... More
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 150 mm dia

1

-

-

... More
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.

2

-

-

... More
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal

9

-

-

... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve &nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metalvalve & M.S. Pipe and socket. 30- M

9

-

-

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal

9

-

-

... More
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as. Gun Metal

9

-

-

... More
Providing and fixing door with frame for all internal fire hydrants fabricated from 20x20x3 mm and 40x20x3 mm aluminium hollow box sections mounted with 3 no. of 100 mm Aluminium butt hinge on Aluminium angle frame of 45x45x5 mm size with hold fasts fixed to wall with P.C.C. (1:2:4) blocks 100x100x100 mm including 2 nos allen key lock for locking along with padlock arrangement & fully glazed with 4 mm thick float glass approved by local Fire Authority, powder coated fire red finish with " fire hose' written on front suitable to house 15 mm long two length of canvas hose with couplings, one no of branch pipe, one fire mans axe and two numbers of portable extinguishers, first aid fire hose and supports for hoses, branch pipes, Axe and hose reel. Size 1200x 600 mm complete as per approved design including necessary fixing arrangement for hoses & axe and branch pipe.)

9

-

-

... More
Supplying and fixing of Fire Man's Axe with heavy insulated rubber tested upto 20 KV and confirming to IS :926.

9

-

-

... More
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.

9

-

-

... More
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way 100 mm dia M.S.Pipe

1

-

-

... More
3 way 150 mm dia M.S.Pipe

1

-

-

... More
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.

2

-

-

... More
Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylindrical body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS : 15683 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge. Capacity 4.5 kg. ISI Marked.( Contractor should submit test certificate form manufacturer along with serial number of every extinguishers supplied.)

6

-

-

... More
Providing and fixing water Co2(ISI marked) extinguishers including all accessories as per IS specification with wall bracket with rawl plug. Capacity 9 liters.(IS:15683)

6

-

-

... More
Providing and fixing of self illuminated / auto glow "EXIT" signs printed on photoluminescent sheet containing self illuminated base chemical, of appropriate size not less than 400 x 150 mm, suspended from ceiling or fixed to the walls with accessories as required and as directed at site.

12

-

-

... More
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head

1

-

-

... More
Providing and fixing liquid level controller for fire pump to stop fire pump in case of low level of water in tank , cost of conduit, cable and panel including making connection to pump panel and commissioning complete. Float type Sensor with panel and installation

2

-

-

... More
Providing and fixing rubber expansion joint (to provide relief from stresses at pipe flanges) as per specification of the manufacturers and direction of Engineer in chief PN-16 rating 100 mm dia

2

-

-

... More
150 mm dia

4

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A

185

-

-

... More
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A

177

-

-

... More
wiring of following light point with 1.5 sq.mm FRLS PVC insulated copper conductor cable in PVC conduit recessed including chasing of wall, filling of chases with cement mortar 1:3 mix and /or fixing conduit on surface of wall/ceiling including fixing of saddles etc. including modular range of plate switches, modular cover plate, ceiling rose, surface or deep tee, circuit wiring (2x2.5+1x2.5), 1.5 sq.mm FRLS PVC insulated copper earth wire, etc. complete as required. One point controlled by one number 10 Amp MCB (First point)

31

-

-

... More
Looping Point above

97

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

2

-

-

... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire

1500

-

-

... More
4 X 6 sq. mm + 2 X 6 sq. mm earth wire

200

-

-

... More
4 X 16 sq. mm + 2 X 6 sq. mm earth wire

200

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).

11

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.

396

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.

83

-

-

... More
Supply & fixing of Universal Socket with 4.0 sq.mm PVC insulated multistranded copper conductor cable (FRLS Type) in surface / recess 1.8 mm thick PVC conduit including cutting the chases in wall & making good the same including providing & fixing of M.S. Switch & outlet box, modular range 13Amp switch with 3 pin 13Amp socket, modular cover plate, earthing with 4.0sq.mm PVC insulated copper conductor cable / wire (FRLS Type) etc. complete as required & as per specifications.

1

-

-

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 6 way (4 + 18), Double door

14

-

-

... More
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps

14

-

-

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps

42

-

-

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole

300

-

-

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

24

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door

6

-

-

... More
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps

6

-

-

... More
SITC OF 8 W LED 6500 K Slim, compact, auminum die cast edge lit panel. Recess mounted round fixture with opal diffuser and separate electronic driver. MAKE :- Havells

321

-

-

... More
Supply installation testing commissioning of TRIM CLIPON LED PANEL SQUARE 24 W LED 6500 K Make:- Havells

6

-

-

... More
SITC of Bracket Light on Wall as/Specification - Decorative, wall mounting, antique brass finish fixture with opal glass diffuser suitable for 10 W.Make:- Havells

64

-

-

... More
SITC of 10 W WH LED Bulkhead Light as/Specification,PDC AL Housing,system watage -10 w,Lumen pack - 800 with eficacy - 800lm/w,CRI-80. , IP -65,Surge protection - up to 5 kv with IS 10322 (part 5/Sec.1)-2012.

50

-

-

... More
SITC of 5 W WH LED Mirror Light

18

-

-

... More
SITC of 20W Ceiling Mounted Led Batten Light

12

-

-

... More
Supply installation testing commissioning of 1200 mm fan

134

-

-

... More
Supply installation testing commissioning of 1400 mm fan

8

-

-

... More
Supply installation testing commissioning of Exhaust Fan

9

-

-

... More
IP Dome camera: Supply, installation, testing & commissioning of Indoor Application 2 MP IP Dome cameras with resolution, SD card recording support, POE Mounted on True Ceiling / False ceiling . Complete with all mounting brackets & accessories.

9

-

-

... More
IP Bullet camera: Supply, installation, testing & commissioning of Outdoor Application 2 MP IP Bullet cameras with resolution, SD card recording support, POE Mounted on True Ceiling / False ceiling . Complete with all mounting brackets & accessories.

4

-

-

... More
Fixed Dome Camera : For Lift Supply, installation, testing & commissioning of Indoor Application 2 MP IP Dome cameras with resolution, SD card recording support, POE Mounted on True Ceiling / False ceiling . Complete with all mounting brackets & accessories.

2

-

-

... More
20 Channel NVR (Network Vedio Recorder): Supply, Installation, Testing & commissioning of 20 Channel NVR (Network Vedio Recorder), for recording upto 16CH @ 1080P with 01 nos. SATA HDDs

1

-

-

... More
Supply, installation, testing & commissioning of 42" inches LED screen suitable for showing out puts from NVRs on a single screen complete in all respect .Make- Samsung/Lg

1

-

-

... More
Supplying Installation testing and Commissioning of Core Cum Distribution Switch with at least 24 X SFP+ 10G Ports

1

-

-

... More
LAYER 2 SWITCH Supply, Installation, Testing and Commissioning of Layer 2 manageable networking switch, 24 # 10/100/1000Tx ports, all 24 ports shall be capable of providing PoE as per 802.3at, minimum 4 SFP ports.

5

-

-

... More
LAYER 2 SWITCH Non PoE Supply, Installation, Testing and Commissioning of Layer 2 manageable networking switch, 48 # 10/100/1000Tx ports, minimum 4 SFP ports.

5

-

-

... More
Supply ,installation,testing & commisioning of Point to point Radio Transmitter and Receiver For Lift Camera

25

-

-

... More
Supply & laying of CAT-6 Cable 23AWG solid bare electrolytic grade copper unshielded type cable. Unshielded twisted pair cabling system, TIA / EIA 568-C.2 Category 6 Cabling system, CM/CMR rated.cable should be ETL Verified, UL Listed and UL channel verified- All three Certificates are mandatory.It should be IEEE 802.3ab - Zero-bit Error, ETL verified .cable Frequency tested up to 500 MHz.

18000

-

-

... More
Supply, installation, testing & commissioning of 10 TB

1

-

-

... More
Supply, Installation,Testing and commissioning of loaded 24 port CAT6 Patch panel for CAT6 cable termination.It must be made of cold rolled steel, Shall be unloaded individually replaceable Category-6A or cat6 I/O Patch. Each jack for the Patch panel must provide a Cap on Patch panel or Shutter on I/O to avoid dust and contaminates entering the Patch & for 100% dust free environment.Patch Panel shall be RoHS Compliant, Should be certified by UL. Certificates.Each port / Patch on the panel should be individually removable on field from the panel.THe scope included all required hard wares & inter connections.

15

-

-

... More
Supply and laying Cat -6 Patch Code 1 Mtr./2 Mtrs.

630

-

-

... More
Supply Installation Testing & Commissioning of floor Mount Rack 42 U/800mm(W)/800mm(D),Single Section(Alongwith Front Glass Door Lockable), Fan 90CFM 230 VAC (Directly Mounted on Top Panel) 19" Cable Manager 1U (MS),19" Cantilever Tray 1U/255mm(D), Hardware Front pannel ( Pkt of 10 Nos),Anchor Fashner (Set of 4 Nos.), PDU 6 Points 5 Amp. Socket.

1

-

-

... More
Supply Installation Testing & Commissioning of Rack 19" Wall Mount 15 U/600mm(W)/500mm(D), Single Section(Along with Front Glass Door Lockable),Fan 90CFM 230 VAC ( Directly Mounted on Top Panel ), 19" Cable Manager 1U (MS),Hardware Front pannel (Pkt of 10 Nos), Anchor Fashner ( Set of 4 Nos ),PDU 5 Points 5 Amp. Socket. with fiber termission box.

5

-

-

... More
Supply and laying including terminations of FR-LS(H) PVC insulated, unsheathed, 1.1kV grade PVC insulated, Extruded FR-LSH PVC inner sheath Type ST-1, FR-LSH PVC outer sheath Type ST-1, stranded Copper conductor Un-Armoured cables as per IS:1554. 3 core 1.5 sqmm flexible cable

200

-

-

... More
Providing and fixing in position of PVC Flexible conduit including bends, junction boxes, pull boxes, GI pull wire including necessary civil work such as chase cutting, chipping, making good for recessed conduiting or clamping on surface with saddles, clamps etc. for surface conduiting: 25mm dia, 16G PVC conduit.

8000

-

-

... More
WIFI AP CLOUD CONTROLLER Supply, Installation, Testing and Commissioning of Wireless Controller capable of supporting UNLIMITD access points, inclusive of license costs for 192 Access Points as per technical specification etc. as required.

1

-

-

... More
WIFI ACCESS POINT (INDOOR) Supply, Installation, Testing and Commissioning of Wireless Access Point supporting Dual band with 802.11a/n/ac (5 GHz) and 802.11g/n (2.4GHz) concurrent operation with MIMO support 3x3, 3 spatial streams, PHY data rates upto 1.3Gbps per radio, One 10/100/1000 BASE-TX auto-sensing (RJ45) PoE port as per technical specification etc. as required.

18

-

-

... More
S.I.T & C of flange mounted Pole of 6.0 Mtr height made from 3.5 mm thick HT Steel plate, having complete with window with flash cover at a height of 300mm from the base for cable termination block etc and base plate of size 300 mm x 300mm x 16 mm thick on existing cement concrete pedestal as required including supplying and fixing the following in the window box provided for cable termination as per direction of engineer incharge:- a) Supplying and fixing 6mm thick laminated mounted sheet inside the window mounted on and including providing and welding 02 nos G.I. strips 4mm thick of suitable length and having suitable size tapped holes as reqd. b) Supplying and fixing 32 Amps terminal block, suitable for 6 sq.mm conductor- 04 nos & shorting links- 05 nos. on DIN Channel including providing. And fixing DIN Channel of suitable length- 01 nos on the existing laminated sheet. c) Supplying and fixing 6 Amps, SPMCB, “C” characteristics curve- 02 nos, Earth stud 02 nos, welded at suitable height, washers, springs washers & nuts. rating IK 08 (Make:

8

-

-

... More
Suppplying and laying of following sizes XLPE insulated and PVC sheathed aluminium conductor armoured power cable of 1.1 KV grade of following size in the existing Metal/Hume/HDPE DWC pipe in ground complete as required. 2 x 6 sq mm

300

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

70

-

-

... More
Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV 2 X 6 sq mm (19 mm)

16

-

-

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. (Make:- REX/DURALINE, duly ISI marked). 63 mm dia (OD-63 mm & ID-51 mm nominal)

250

-

-

... More
Providing and laying in position M - 20 reinforced cement concrete foundation of size 550mm x 550mm wide and 1200 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia- 1200 mm long (approx)- 08 nos and reinforcement ring of cold twisted bar of 8 mm dia-190 spacing centre to centre (approx)- as required with positioning of foundation bolts as shown in the item given below and providing 63 mm (O.D.) PVC Pipe of suitable length for cable entry & exit as required.

8

-

-

... More
Supplying and fixing set of 04 nos, M20X470mm j-type (EN8 grade) foundation bolt (total length 600mm) with nuts, washer including 01 nos template of 3 mm thick size 220x220mm with 4 nos 24mm dia holes, to match with PCD of pole base plate as reqd.

8

-

-

... More
Supplying & Fixing of 1.5 meter long Galvanized single arm bracket for mounting on pole and fixing of fixture including with tightening bolts etc as approved by

8

-

-

... More
Installation Testing & Commisioning of LED LIGHT Fitting of 90 watt LED Lamp, control gears such as choke condenser and igniter etc. on the street pole

8

-

-

... More
Design, manufacture, supply, delivery including supervision during installation, testing and commssioning of 1 panel, 11KV HT VCB switch board with following accessories: One No. incoming panel equipped with following:- 630A, 11KV, VCB 25 KA, TP, totally enclosed, air insulated metal clad housing, cassette mounted horizontal isolation, horizontal drawout type, motorised spring charged, manually operated, trip free, vaccum circuit breaker (VCB) having double isolation features and control devices complete with mechanical with continous tripping & closing, coil suitable for 24V DC, shunt trip coil, OFF/ON indicators, mechanical operation counter & provided with following: Spring charge / discharge mechanical OFF push buttons for emergency trip (test / service position limit switches with 6 NO/6 NC breaker auxiliary contacts in service position. 1 No. CT chamber with single wound single phase, dual core cast resin CT, 15VA burden with core-1 for metering (CL-1) and core-2 for protection (CL-5P10) and of 20/5+5A ratio.3 Nos.Microprocessor based relay, IDMT, Time delay with 3 elements for over current (50-200%) and 1 element for earth fault protection(10-40%) . 1 Set Antipumping relay & master trip relay 1 Set Digital Ammeter with selector switch. 1 Set A set of breaker ON/OFF/Trip/DC control supply/ Spring Charged indication lamp. 1 Set Emergency trip push button on front door . 1 Set Limit switches with 6 NO/ 6 NC breaker auxiliary contacts 1 Set Control:- T-N-C (Trip, Neutral, Close) breaker control switch. 1 Set Space heater with thermostat for moisture absorption. 1Set Suitable for connection to 3 core x 240 sq.mm. Cross linked polythelene (XLPE) 11KV cables or as called for. 1 Set HT Danger Plate 1 Set Hooter low intensity 24 Volt with acknowledge and reset push button 1 Set 6-window microprocessor based annunciation panel with audio and visual indicator. Over current & earth fault - 2 windows Spare - 3 windows Surge Arrestor, 10KA, Class II 1 Set 1 Set Incoming as described above. 1 SET HT Panel as described above (1 No.Incoming cum Outgoing Panel)

1

-

-

... More
Unloading, receiving, storing, installation in correct assigned positions, effecting proper connections, testing & commissioning of 11KV 1 breaker panel (1 No. Incoming cum Outgoings) Board as per manufacturers instruction, as per specification and complete as required.

1

-

-

... More
Supply, Installation, testing and commissioning of 100 AH capacity, 24V DC maintenance free SMF Batteries in fully charged condition, including painted MS stand & spill proof plastic trays etc.complete as required as per specifications.

2

-

-

... More
Supply, Installation, Testing & Commissioning of Battery Charger Unit with provisions of "Boost Charging" and "Float Charging", suitable for 240V, single phase, AC, 50Hz supply system & 24V DC including providing required MCB for DC supply distribution to panel complete as required.

2

-

-

... More
Supply and fixing in position the approved "shock treatment charts" framed in teak wood frame and covered with glass in front as required in two languages (Hindi & English)

4

-

-

... More
Supply & fixing of Mimic diagram for overall schematic of power distribution complete as required.

4

-

-

... More
Supply and fixing in position the best quality "Danger Boards" of approved shape and size as specified by Local Electricity Authorities written in English and Local languages. 11KV (250mm X 200mm)

4

-

-

... More
415V (150mm X 100mm)

4

-

-

... More
Supply & Laying of non skid Electro mat 1 mtr wide and 3.0 mm thick 11KV grade conforming to IS 15652 as required including cutting to required length complete as per requirement of local electricity authorities.

20

-

-

... More
Supply of fire buckets 5 nos. 15 litre capacity duly filled with fine sand and fixed on an angle iron frame as per requirement of local authorities. The fire buckets shall be painted red from outside and white from inside, including lettered as FIRE with white colour with extra handle at bottom.

1

-

-

... More
Supply & Laying of non skid Electro mat 1mtr wide and 2.0 mm thick 1.1KV grade IS 15652 as required including cutting to required length complete as per requirement of local electricity authorities.

25

-

-

... More
Supply of Rubber hand gloves 11KV grade, as per IS 4770-1968.

2

-

-

... More
Supply of standard first aid box as approved by Indian red cross society/ St.John Ambulance Brigade and conforming to IS 2217-1963.

2

-

-

... More
Supply & Installation of Earthing Trucks (Casette type) of same Make as HT Panel complete as required.

2

-

-

... More
Supply, Receiving, shifting, laying, testing and commissioning of following 1100V grade PVC insulated armoured copper conductor control cables on existing cable tray/ trench as per specifications including of all clamps/ saddles/screw and cable identification tags etc. complete as required including termination of the following sizes of PVC insulated Copper conductor cable including providing terminal lugs,single compression gland , crimping the joints ,providing insulation tape,effecting terminal connections to the equipment.(For HT Panel controls, Transformer Protection, PLC controls. 2C X 2.5sq.mm Cu. Cable

50

-

-

... More
12C X 1.5sq.mm Cu. Cable

50

-

-

... More
10C X 2.5sq.mm Cu. Cable

50

-

-

... More
2C X 1.5sq.mm Cu. Shielded Cable

50

-

-

... More
Supplying, Receiving, shifting, and commissioning of following sizes of 11 KV grade XLPE insulated aluminium conductor armoured power cables conforming to IS : 7098 (Part-II) laid buried in ground / trench / existing Hume pipe / PVC pipe / GI pipe in an approved manner complete as required and as per specifications including excavation of trench in all classes of soil, including supply and provision of sand bed above the cable and below the cable with supply and laying of 1st class brick protection back filling of the trench with excavated earth free from boulders after laying and dressing of the cable in an approved manner complete as required as per IS1255 and as per drawing. 3 core X 185 sq. mm

50

-

-

... More
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. a. Above 120 sq. mm and upto 400 sq. mm

50

-

-

... More
Supply & Installation of 11KV XLPE cable end terminations including termination kit, cable crimping lugs, insulation tape etc. complete as required 3 core X 185 sq mm (outdoor type)

1

-

-

... More
3 core X 185 sq mm (indoor type)

3

-

-

... More
Supply,installation,testing and commissioning of two pole structure with required arrangement for terminating 11 KV overhead conductor on one side and 11 KV, 3 x 185 sq.mm. Al conductor XLPE cable on the other side including providing triple pole ,mechanically operated mounted on insulators and steel frame with operating mechanism worked from ground level,expulsion fuses of 11 KV ,required rating along with 11 KV 200 amp air break isolator suitable for outdoor application ,earth switch, Metal oxide type Lightning arrester complete with all fittings and discharge capacity 50 KA complete as required.(This structure shall be supplied and installed as per Local Electricity board norms.)

1

-

-

... More
Supply,installation,testing and commissioning of Metering cubicle as per local electric authority norms including providing required CT and PT complete as required

1

-

-

... More
Design, manufacture, supply,including supervision during installation, testing and commissioning of the following extensible cubicle type indoor mounting, dead front, fully compartmentalised with hinged lockable detachable front & back openable, dust and vermin proof, floor mounting sheet steel clad switchboard fabricated out of 2 mm thick CRCA powder coated sheet steel suitable for use at 415 volts 3 phase 4 wire 50 cycle system and to withstand a symmetrical fault level of 50 KA at 415 volts. Panels shall be fabricated in easily transportable sections, length, height, depth etc. to match with site condition. All incomer breaker and Bus Couplers shall be interlocked electrically as shown in SLD and specifications.The following provisions shall be required to be made in the Main LT Panel as detailed below:The Switchboards shall have provision to accommodate all cables from the bottom /top as require All live accessible parts shall be shrouded with 1mm thick polycarbonate/3 mm thick FRP sheet and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable sleeves according to the colour code. SMC shrouds and busbar supports shall be used. All MCCB door handle shall be interlocked and lockable in OFF position.Galvanised hardware with zinc passivation shall be used in fabrication of Switchboards. Suitable Aluminium earth bus to be provided throughout the length of Switchboards.All indication lamps / illuminated push buttons shall be LED type.All incomer meters of Main LT Panel shall be multifunction & should have all the electrical parameters like Ampere, KW, KVAR, KWH, PF, Frequency etc.Coil of all motor starters shall be fed from 440 V / 230 V Control Transformer.2A SP MCBs shall be used as backup protections.All MCCBs shall be variable plug setting type with thermal magnetic up to 630 A rating and with microprocessor based releases above 630 A rating, line load reversibility, Ics = 100% Icu,& rotary handle.All control& power wiring shall be broughtout upto the cable alley in the terminal blocks.All incomer ACBs of Main LT Panel shall be with micropocessor based releases (O/C, S/C & E/F) All rear door of Main LT Panel shall be almirah type with lockable arrangement.All rear door of Main LT Panel shall be almirah type with lockable arrangement. Space heater shall be provided with thermostat with 6A MCB as backup protection in each section of Main LT Panel controlled with feeder 20 A DP MCB 10 KA.An approval shall be taken for each panel before manufacturing.Provision for providing 230V or 24V supply for Dual KWHr metering when any or all DG are in operation One separate compartment of minimum size 400 x 900 mm for power management system of D.C.U.'s with control wiring as per following specification and control wiring scheme:Control wiring shall be looped from each energy meter till DCU's compartment for sending DCU register change command from data connectivity.Provision of one 6/16 amp socket & compartment lighting for each vertical section of main panel.5 nos extra of each R,Y,B,G,A colour indicating lamp and illuminated push buttons and normal push button shall be provided with main LT panel .MIMIC diagram shall be for Main LT panel MIMIC shall be made of polycarbonate sheet of 5 mm thickness fixed on acylic sheet of 2mm thick.the size of panel shall be such that the diagram can be visualized from 5 to 6 meter distance. The panel shall display complete single line diagram of Main LT Panel. this line diagram shall be made from luminous non fading materials to glow in dark and each breaker legend shall be provided with bi-colour LED lights to show the ON/OFF status of the respective feeder (Incomers / Bus couplers) All CT shall be cast resin type. Class - 3 CT shall be provided up to 60 amp and above that the CT shall be Class - 1. Illuminated push button on Starter Panels of Pumps. Interlocking / Auto start command terminals for starter Panels. All breaking Capacity for ACB to be Ics=100%Icu and Icw for 1 sec.. All breaking Capacity for MCCB to be Ics=100%Icu. All MCB to be C Curve Addiional CT's if required for REF of suitable rating burden / class shall be supplied by the Contractor / Panel Manufacturer.Responsibility of installation of KWHr meter, integration with electrical system, billing system and smooth operation of system shall lie with contractor. All the DG set shall be Synchronized. 200 Amps, 25KA,415 volt 4-P MCCB with contactor with micro processor based tripping mechanism, shunt release (24V DC), earth fault release and inbuilt O/C & SC releases (Microprocessor based) having variable range with time lag facility to acheive discrimination. Required Interlocking with other incomers Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port with 3 Nos. current transformers of 200/5 ratio, 15 VA Class 1.0 for metering. 6 nos NO/NC contacts for remote opening & closing. Red/Green/Amber ON/OFF/TRIP indicating lamps with 2A SP MCB backup protection.1 set of three phase indicating lamps along with 2A SP MCB backup protection.1 no. current transformer of 200/5A ratio Class 1.0, 15 VA Burden for PF correction relay.Motor wound spring closing mechanism.Suitable arrangement to receive incoming cable of 1 runs of 3.5 x 120 sq. mm "Al." XLPE conductor .T-N-C Breaker control switch Control MCB, control terminals& wiring as required.One auto/manual selector switch Combined Under voltage and over voltage relay ,3 Phase with Time delay setting. Restricted Earth Fault Relay , 1 no. current transformer of 200/5A ratio Class PS 15 VA Burden to be supplied loose to mount in Transformer One no. 5 KVAR capacitor bank MPPH type along with 16 TP MCCB, 25 KA service breaking capacity for direct connection, along with ON indication lamp. Intertripping relay.Electrolytic high conductivity aluminium three phase and neutral busbars rated at 250 amps, 25KA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. Current density of Bus Bar to be 1.2 sq.mm / amp. Neutral Bus Bar shall be 50% of Phase Bus Bar.3 nos. 125 Amps 25 kA 440 volt FP MCCB with overcurrent,earth fault and short circuit releases each complete with: 3 nos 125/5A Class - 1.0, 15 VA Burden CT's for metering Digital flush type class -1.0 accuracy multifunction meter ON / OFF indicating lamps with MCB as backup protection. RYB Phase Indication Lamp with MCB as backup protection. 2 nos. 100 Amps 25 kA 440 volt FP MCCB with overcurrent,earth fault and short circuit releases each complete with:3 nos 100/5A Class - 1.0, 15 VA Burden CT's for metering Digital flush type class -1.0 accuracy multifunction meter ON / OFF indicating lamps with MCB as backup protection. RYB Phase Indication Lamp with MCB as backup protection. 1 nos. 63 Amps 16 kA 440 volt FP MCCB with overcurrent,earth fault and short circuit releases each complete with:3 nos 63/5A Class - 1.0, 15 VA Burden CT's for metering Digital flush type class -1.0 accuracy multifunction meter ON / OFF indicating lamps with MCB as backup protection. RYB Phase Indication Lamp with MCB as backup protection. 2 nos. 40 Amps 16 kA 440 volt FP MCCB with overcurrent,earth fault and short circuit releases each complete with:2 n 3 nos 40/5A Class - 1.0, 15 VA Burden CT's for metering Digital flush type class -1.0 accuracy multifunction meter ON / OFF indicating lamps with MCB as backup protection. RYB Phase Indication Lamp with MCB as backup protection. 1No. 40A FP MCB 1No. 63A FP MCB a. 1 nos. 100 Amps 25 kA 440 volt TP MCCB complete with microprocessor based tripping with overcurrent,earth fault and short circuit releases each complete with: i. 3 nos 100/5A Class - 1.0, 15 VA Burden CT's for metering ii. 96 sq mm flush mounting 0-100 Amp Digital Ammeter with selector switch. iii. ON / OFF indicating lamps with MCB as backup protection b. Indicating lamp in each 5 KVAR capacitor chamber unit to indicate "ON"/"OFF" status of capacitor unit. (30 KVAR). c. Stepped relay(APFCR) with 6 steps (each to be of 5 KVAR) for automatic power factor correction having facility to change the sequence of switching 'ON' the capacitor banks as required. The program of APFCR shall be re settable to enable sequance of ON/OFF of individual bank, so that the end unit of capacitor bank is not kept idle for long. a. 6 nos. of capacitor duty contactors b. 6 Nos. 5 KVAR MPP type heavy duty capacitor banks.c. 6 Nos. 16 A TP MCCB of 50 KA service breaking capacity with heavy duty solid detachable neutral link d. 6 Sets of Push button stations 'RED' and 'GREEN' push buttons for manual operation of capacitors. e. No. selector switches for changing automatic to manual operation of capacitors.(A/M)f. Enclosure of capacitor panel shall be liberally designed to take care of internal heat emission by capacitor unit without forced cooling and to limit the temperature rise with in permissible limit. However, louvers are allowed to facilitate extra cooling. 60 Amps, 25KA,415 volt 4-P MCCB with contactor with micro processor based tripping mechanism, shunt release (24V DC), earth fault release and inbuilt O/C & SC releases (Microprocessor based) having variable range with time lag facility to acheive discrimination. Required Interlocking with other incomers The Incomer shall have suitable arrangement for termination of Cable on incoming side and busbar connection at outgoing side, complete with following Digital flush type class -0.5 accuracy multifunction meter with RS-485 communication port for measurement of THD, KVARH KW, KWH, KVAR, PF, V, A, Hz , equivalent to EM6400, with 3 Nos. current transformers of required ratio, 15 VA Class 0.5 6 nos NO/NC contacts for remote opening & closing. Red/Green/Amber ON/OFF/TRIP indicating lamps with 2A SP MCB backup protection. 1 set of three phase indicating lamps along with 2A SP MCB backup protection. Spring charge & DC supply healthy, DG set on, indicating lamp with 2A SP MCB backup protection. Motor wound spring closing mechanism. Suitable arrangement to receive incoming cable of 1 runs of 3.5 x 95 sq. mm "Al." XLPE conductor. T-N-C Breaker control switch Suitable arrangement to receive incoming cable of 1 runs of 3.5 x 95 sq. mm "Al." XLPE conducto Combined Undervoltage & Overvoltage relay 3 phase with time delay setting, Reverse Power relay. One auto/manual selector switch v One 16 amp automatic Battery charger with inbuilt facility of trickle / boost & consisting of : DC Ammeter (0-30)Amp. DC Voltmeter.(0-30)V Charger ON, OFF indications . DG set Alarm DG set Fault DC supply failure O/V Fault Spares.Main LT / Capacitor Panel as described as above and as per specification complete in all respects.

1

-

-

... More
Design, manufacture, supply,including supervision during installation, testing and commissioning of 2 mm thick MS sheet steel fabricated cubicle type Panel dust and vermin proof complete with hinged and lockable doors . The Sheet Steel shall under go minimum eight tank treatment followed by finishing treatment of powder coating with 70 micron minimum thickness. All the panels shall be floor mounted and dead front construction complete with interconnections. (Form IIIB) The panels shall be FRONT operated, with cable entry from the top. Earth bus shall be part of the panel.) (All MCB to be "C" Curve)The following provisions shall be required to be made in the Distribution Panel as detailed below: All live accessible parts shall be shrouded with 1mm thick polycarbonate/3 mm thick FRP sheet and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable sleeves according to the colour code. SMC shrouds and busbar supports shall be used. All MCCB door handle shall be interlocked and lockable in OFF position. Galvanised hardware with zinc passivation shall be used in fabrication of Switchboards. Galvanised hardware with zinc passivation shall be used in fabrication of Switchboards. Suitable Aluminium earth bus to be provided throughout the length of Switchboards.All indication lamps / illuminated push buttons shall be LED type.Coil of all motor starters shall be fed from 440 V / 230 V Control Transformer.2A SP MCBs shall be used as backup protections.All MCCBs shall be variable plug setting type with thermal magnetic up to 630 A rating and with microprocessor based releases above 630 A rating, line load reversibility, Ics = 100% Icu,& rotary handle.All control& power wiring shall be broughtout upto the cable alley in the terminal blocks.An approval shall be taken for each panel before manufacturing.Provision of one 6/16 amp socket & compartment lighting for each vertical section of main panel. Illuminated push button on Starter Panels of Pumps.Interlocking / Auto start command terminals for starter Panels.All breaking Capacity for ACB to be Ics=100%Icu and Icw for 1 sec..All breaking Capacity for MCCB to be Ics=100%Icu.All MCB to be C Curve 1 no. of 100 Amp FP MCB of 25KA breaking capacity. Metering for incoming: Digital Multifunction meter with RS-485 communication port for measurement of PF, V, A & Hz , equivalent to EM6459,with CT as required. Phase indicating lamps RYB with 2 Amps SP MCB back up. ON / OFF indicating lamps Electrolytic high conductivity aluminium three phase and neutral busbars rated at 125 Amps, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. Current density of Bus Bar to be 1.3 sq.mm / amp. Outgoings 6 no. of 40 Amp DP MCB of 10KA breaking capacity. UPS PANEL -1 as described above .

1

-

-

... More
GROUND FLOOR PANEL Incoming: 1 no. of 125 Amp FP MCCB of 25KA breaking capacity. Metering for incoming: Digital Multifunction meter with RS-485 communication port for measurement of PF, V, A & Hz , equivalent to EM6459,with CT as required.Phase indicating lamps RYB with 2 Amps SP MCB back up. ON / OFF indicating lamps Bus Bars Electrolytic high conductivity aluminium three phase and neutral busbars rated at 160 Amps, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. Current density of Bus Bar to be 1.3 sq.mm / amp. Outgoings 4 no. of 63 Amp 4P MCB of 16KA breaking capacity. SPARES 1 no. of 63Amp 4P MCB of 16KA breaking capacity. GROUND FLOOR PANEL as described above .

1

-

-

... More
Incoming: 1 no. of 125 Amp FP MCCB of 25KA breaking capacity. Metering for incoming Digital Multifunction meter with RS-485 communication port for measurement of PF, V, A & Hz , equivalent to EM6459,with CT as required. Phase indicating lamps RYB with 2 Amps SP MCB back up. ON / OFF indicating lamps Bus Bars Electrolytic high conductivity aluminium three phase and neutral busbars rated at 160 Amps, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. Current density of Bus Bar to be 1.3 sq.mm / amp. Outgoings 4 no. of 63 Amp 4P MCB of 16KA breaking capacity. SPARES 1 no. of 63Amp 4P MCB of 16KA breaking capacity. FIRST FLOOR PANEL as described above .

1

-

-

... More
SECOND FLOOR& TERRACE PANEL Incoming: 1 no. of 125 Amp FP MCCB of 25 KA breaking capacity. Metering for incoming: Digital Multifunction meter with RS-485 communication port for measurement of PF, V, A & Hz , equivalent to EM6459,with CT as required. Digital Multifunction meter with RS-485 communication port for measurement of PF, V, A & Hz , equivalent to EM6459,with CT as required. Phase indicating lamps RYB with 2 Amps SP MCB back up.ON / OFF indicating lamps Bus Bars Electrolytic high conductivity aluminium three phase and neutral busbars rated at 160 Amps, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. Current density of Bus Bar to be 1.3 sq.mm / amp. Outgoings 6 no. of 63 Amp 4P MCB of 16KA breaking capacity. SECOND FLOOR& TERRACE PANEL as described above .

1

-

-

... More
Design, manufacturing, testing at factory, supply, installation and comissioning at site of true-online double conversion VFI Technology UPS, 1Ph/3Ph. AC input & 3Ph/1Ph AC output UPS system suitable for 415VAC, 50Hz supply, variation +/-1%, PF 0.99 as required as per specification and consisting of following: Input range should be 320V AC-460V AC, in case the voltage range does not meet the specified range, cost of servo stabilizer should be added. THDi3%. Fully microprocessor based with diagnostics capability. Built-in Isolation Transformer at inverter output. Dual Input (Separate Input for rectifier and separate input for Bypass) Upto 6 units can be connected in parallel mode. Required quantity and details of UPS are as mentioned below. Location details and mode of operation of UPS shall be as per Annexure :- UPS ready for Lithium Ion batteries. The Price shall be inclussive of Single / Multi core copper flexible cable from panel to UPS with all fixing accessories. 3 kVA

1

-

-

... More
Design, manufacturing, testing at factory, supply, installation and comissioning at site of One sets of SMF VRLA battery with each UPS capacity as mentioned below, having back up time as mentioned below at full load, with interconnecting single core copper flexible cables, cabinets and standard accessories as per specification and as required for the UPS system. (12V or 24V Cells as per UPS requirements). 90 Minutes back up for 3 KVA

1

-

-

... More
Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of motor control panel shall be fabricated out of 14 gauge CRCA sheet steel in form in 3b formation with reinforcement of suitable size angle iron, channel ‘T’ sections irons and /or flats wherever necessary. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of red oxide primer and final approved postal red color shade of powder coated paint. 2 Nos. earthing terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system. Arrangements shall also be provided for fixing of panel on wall./floor Approval shall be taken for panel before fabrication. Cadmium Plated hardware shall be used in fabrication of panels. complete with suitable size RCC Civil foundation,150 mm height rase or fixing arrangement fasterner,nut bolt and painting etc. in the contractor scope.(PLUMBING PANEL) Incomer One incoming main isolation 4P MCB of 32A rating One square panel type Voltmeter reading 0-500 V with rotary selector switch for reading voltage between phases. One panel type Amperemeter (0-32A) with selector switch and CT 3 phase indication lights 40 TPN Alumninium Buss bar Outgoing 2 no. DOL Starter for 2 HP motror with capability of remote operation of pumps automatic as per 1w+1s 2 No. 16A TP MPCB with industrial socket for welding and other misc purposes. 1 no. single phase preventors of suitable rating. Space for 1 No. liquid level controller Appropriate etched aluminium identification plate for each starter/switch. Colour coded internal wiring from main to bus bar, switchgear, starters, indicating lamps complete in all respects.

2

-

-

... More
Supply, receiving, shifitng, testing and commissiong, of following sizes of 1.1 KV XLPE insulated Aluminium conductor armoured cables complete as required and as per specifications. 3.5 x 120 sq.mm. Aluminium Cable

100

-

-

... More
3.5 x 95 sq.mm. Aluminium Cable

100

-

-

... More
3.5 x 70 sq.mm. Aluminium Cable

150

-

-

... More
4 x 10 sq.mm. Cu. Cable

150

-

-

... More
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

230

-

-

... More
Above 35 sq. mm and upto 95 sq. mm

120

-

-

... More
Above 95 sq. mm and upto 185 sq. mm

100

-

-

... More
Termination of the following sizes of Al XLPE insulated conductor armoured cable including providing terminal lugs,single compression Brass glands crimping the joints,providing insulation tape, effecting terminal connections to the equipment complete as required. 3.5 x 120 sq.mm. Aluminium Cable

2

-

-

... More
3.5 x 95 sq.mm. Aluminium Cable

2

-

-

... More
3.5 x 70 sq.mm. Aluminium Cable

8

-

-

... More
4 x 10 sq.mm. Cu. Cable

6

-

-

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

12

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

6

-

-

... More
Supply and laying in position the following GI tape/wires including providing all fixing accessories and effecting proper connections including clamping to wall with suitable clamp / Saddle and fixing bolts / Soldering / rivetting in ground including the cost of digging & back filling as required & complete as required to comply with IS 3043. All joints shall be tinned. 4 mm dia G.I. wire

200

-

-

... More
25 x 5 mm GI tape

100

-

-

... More
50 x 5 mm Cu tape

50

-

-

... More
50 x 5 mm GI tape

100

-

-

... More
32 x 6 mm GI tape

100

-

-

... More
Supply and installation of following sizes of MS perforated type cable trays with stove enamel paint of approved colour and necessary bends, tees, reducer couplers, dashfastners,GI nuts bolts including cutting,bending, drilling, bolting, required suspension arrangement etc. complete as per specifications and as approved by Project Manager.200 mm wide, 40mm high (2.0 mm thick)

50

-

-

... More
Design, manufacturing, testing at works, supply installation, testing and commissioning of DG Set of following rating for site conditions, complete with Diesel Engine base frame, lube oil system, Radiator, required batteries, governor, instrumentation, day service fuel tank, exhaust silencers including Aluminium cladding, alarms, engine mounted control panel, utility piping, anti vibration pads, Alternator (Stamford/Kirloskar) direct coupled to Engine along with static excitation system and AVR panel and all required accessories complete as required and as per specifications.The scope of work does not include AMF panel, cabling and earthing. Cable Box to be provided for termination of required Al. Cable. The DG Set shall be provided with geneset controller as also mentioned above for AMF / Auto / Manual synchronising, Auto load sharing and having electrical and mechanical parameter monitoring, electrical protection (under and over frequency and voltage, over load (KW), over current, short circuit, reverse power, excitation failure, AMP sentry protection. 82.5 KVA

1

-

-

... More
Supply, laying and fixing of following sizes of MS A Class piping( Tatas, Jindal (Hissar), IST) with bends etc. for Exhaust of DG Sets including providing suitable self supporting arrangement etc. and supplying & fixing 50 mm thick mineral wool insulation of 96 Kg per cubic meter density on all sides of Exhaust pipe and silencer with chicken mesh wrapping and aluminium cladding with aluminium sheet of 26 SWG,suitable for outdoor installation complete as required and as per specification. (Refer Layout enclosed) The DG Exhaust shall be taken along the building supported from the wall however scope includes building required structure for crossing the ramp. 82.5 KVA

35

-

-

... More
Note:- Exhaust pipe sizing will be as per manufacturer Supply & Fixing of miscellaneous structural support for horizontal/ vertical exhaust piping including fabrication, hardwares and painting as per drawing and as per manufacturer recommendation.

200

-

-

... More
EXTERNAL LIGHTING Supplying & fixing of following accessories in the existing cubical panel board / feeder pillar including connection testing etc. as reqd. Supplying, fixing, connecting, testing and commissioning of Astronomical Timer along with power contactor 3 set of Double pole of 32 Amp. in the existing cubical panel board / feeder pillar (Timer shall be capable to operate 3 nos double pole Power contactor seprately t operate at different time schedule), complete in all respects. The above board shall be complete with 3 nos. phase indicating lights, flush mounted Ammeter, Voltmeter, CT's, PT's, selector switches, protective fuses etc. at Incomer with all interconnections by min. 2.5 sq.mm. Copper wires. Danger notice plate INCOMER : 32 AMP FP MCB (10 KA) BUS BAR : 40 AMP, 500 Volts, 3 phase 50 HZ FP high conductivity electrolytic Aluminium bus bar. The current density of bus bar shall be minimum 1.00 sq mm / amp. OUT GOINGS : 15 nos. 6-32 AMP DP MCB (10 KA) : 3 nos. 40 AMP DP MCB (10 KA)

1

-

-

... More
Electrical Manhole Size- 600x600 mm as per standard drawings

8

-

-

... More
Providing and laying of Double Walled Corrugated HDPE Pipe, conforming to IS:16098 SN4, having anti rodancy features complete with accessories including slip fit/push fit type couplers per 6 mtrs. of pipe length. (Excavation etc. will not be paid separately) c. 200 mm diameter

100

-

-

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete a. 200 mm diameter

15

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.