Public Works Department Tender

Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.

Public Works Department - PWD Tender

Works
Civil And Construction
Consultancy Services
Civil And Architectural Services
Water Storage And Supply
Eprocure
Opening Date20 Sep 2024
Closing Date30 Sep 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Survey, Design, Providing, Installation, Testing And Commission Of Duel Powered (spv/grid) Vertical Submersible Pumping Unit Along With Laying Of 1300 M Rising Main From Bore-well To Reservoir For Drinking Water Supply At Garkone (bore Well) Incl

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Designing, providing, installation and testing of VFD Hybrid Controller (including Remote Monitoring System and Suitable Changeover Switch) compatible to run with both AC & DC supply (dual purpose) grid & solar supply strictly conforming to relevant ISI/ISO/IEEE standards, compatible for the above pump rating. Including defect liability period of 36 m0nths after successful commissioning and test running of one month . ( Complete job). Control panel ------ Variable Frequency Drive (VFD) with dual option for Solar/grid supply Circuit breaker --------- 40 Amp ± 10% Cable size -------------- 04 sqmm (copper) as per IS694 Insulation --------------- XLPE Safety wire ------------- to be quoted The unit must be inherently designed for Over load protection Over heat protection Over current/under current protection (complete job in all respects)

22

-

-

... More
Supply, installation and testing of array junction box IP 65 with fuse, surge protection and necessary diode arrangements. complete job in all respects including defect liability period of 36 months after successful commissioning and test running for one month .complete job ) including a defect liability period of 36 months after successful commissioning and test running of one month.

22

-

-

... More
Designing, providing, installation, testing and commissioning of shock proof, Photo Voltaic Solar panels with all necessary wirring, electronics and safety equipments. Including defect liability period of 36 months . No of photo voltaic panels --------------------60 (max)/ OEM’s discretion Operating temperature for Solar cell -20°C to +45°C Temperature coefficient ------------ - 0.286 to 0.4 Max power at STC ------------ ---- 79% to 82% Module efficiency ---------------- 20 or more PV Modules specifications: The PV module shall contain mono/multi crystalline silicon solar cells: Power of a single module :330 W ± 5% Open circuit voltage: 44-46V Voltage at max. power : 35-38 V Current at max. power : 8-9 A Series fuse ratings : 10 A or as required Application class ratings: Class A Fire ratings: Class-C The PV module shall be as per IEC 61215 revised specifications. Certification ---------- MNRE/ISI/ISO/IEEE/IEC or equivalent Other details/technical specifications/requirements not mentioned in the BOQ should be provided as per the site requirements and in correspondence to the requirements as per laid national/international standards Complete in all respects

22

-

-

... More
Providing and fixing in position/grouting (crushed aggregate 20mm), of Solar panel mounting frames and fixtures, as per given details: Hot dip galvanized steel structure (6040×2.9 mm) designed to cater to min 150 Km/hr wind speed and/or to bear the weight of min 1m high snow on solid foundation made of reinforced in M 20 concrete( crushed aggregate 20mm) being enough to hold the weight of structure (to be developed separately. Height of the panel holding structure upto 10 ft from the surface of the foundation block. Running length of ISA to be used for structure specified above should not be less than 150 ft. etc @ 0.014kg/w (Complete job in all respect)

325

-

-

... More
Providing and winding of pipe heating cable (heat tracer standard make conforming to relevant ISI/ISO/IEEE (515.1) or equivalent certification) around the delivery header upto a substantial depth to be decided by the engineer in-charge, as per the site conditions and highly efficient winter friendly hassle free (replaceable) thermal insulation for pump casing below ground level to maintain the inner ambient temperature of the casing between 15-25°C by way of designing, providing and installing sensor operated thermostat of approved brand conforming to relevant ISI/ISO/IEEE/ASME or equivalent standards, to render the pumping unit operable the year round. The cable shall draw the energy from the SPV/AC supply proposed for the scheme. Complete job of The job also includes providing and installation of GPS monitored flow meter of approved make conforming to the relevant ISI/ISO/ASME standards. specifications temperature to be maintained --- 15-25 °C power output ----- 5W/ft for bore well power output -------- 8 W/ft for dug well (closed) tinned copper bus wires armoured jacket thickness (min) ------ --- 0.10 mm jacket material --------silicon polymer/ with copper ground braid

15

-

-

... More
Providing and fitting of UPVC (Un plasticized Polyvinyl Chloride) Column Pipe of dia 63mm ASTM-D-1785 SCH-40 along with CI top bottom adapter and borecover.

160

-

-

... More
Providing, laying, fusion, testing and commissioning of rising mains (from Borewell to reservoir (SR) per the following specification Rising main/Dia----------------- 1300 RM/ 75mm Material ------------------------ HDPE-PE 100 Minimum working pressure – PN 16 IS 4984:2016 (ISI) The job includes providing & fitting of all accessories and mountings

1300

-

-

... More
Providing and fitting of Zero velocity NRV DN 65 PN16 along with necessary fittings and arrangement and 8.8 grade HDG HT Hex nut bolt

1

-

-

... More
Providing and fitting of DN 50, PN16 Air Valve (Anti-surge non slam anti water-hammer combination type) with necessary fittings and arrangement and 8.8 grade HDG HT Hex nut bolt

2

-

-

... More
Providing and fitting of DN 65, PN16 Gate Valve with necessary fittings and arrangement and 8.8 grade HDG HT Hex nut bolt

1

-

-

... More
99.97 % pure bare 4-Cored copper Un-Armoured cable conductor with moisture resistant, having a tem range of -15 to +70 degree conforming to ISI 694, IS 7098 Size: 04Sqmm

125

-

-

... More
Maintenance free earthing to Controller: SITC of maintenance free chemical Earthing using Electrode of size 76 mm dia, 85meter long connected with 50x6 mm GI internal strip complete with excavation, civil works, cast iron cover with back fill compound. The voltage between Neutral & Earth not to exceed 0 volts & IR value less than 1 ohm. The earth resistance shall be as per IS 3043. The job also includes connecting of earthing to the equipment as per directions of the site engineer using 25x6 GI Strip.

1

-

-

... More
Earth work in excavation by manual means in trenches for foundation ,drains, pipes ,cables etc.(Not exceeding 1.5mtr in width ) and for shafts, wells, cesspits and the like not exceeding 10sqm on plan ,depth up to 1.5mtr including disposal of excavated earth up to 1mtr from cutting edge, disposed earth to be leveled and neatly dressed in:

-

-

-

... More
All kind of soil 30%

983.34

-

-

... More
Ordinary rock 30%

8.34

-

-

... More
Hard Rock (by Chiseling) 40%

11.12

-

-

... More
Providing and laying cement concrete work in wall any thickness incl. attested plaster buttresses plain and string courses fillets colon columns, pillars, piers, abutments, posts and sturts etc upto floor five level excluding cost centering shuttering finishing and reinforcement.1:3:6(1cement: 3 coarse sand: 6 graded crushed stone agg. 20mm nominal size. including all carriage complete.

48.6

-

-

... More
Centering and shuttering including strutting, propping etc. and removal form for:-

-

-

-

... More
Footings bases of columns etc.yuh for mass concrete.

290

-

-

... More
Proving fixing of angle iron post in position (5050x6mm ) size including flat iron monger(40x5mm) and Nuts/Bolts/Washers as per the direction of site Engineer in charge including all carriage complete.

479

-

-

... More
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 4 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4 mm

136.64

-

-

... More
Proving fixing of steel gate of angle iron ( 40x40x6mm ) size including flate iron size of (3'x7') as per the direction of site Engineer incharge including all carriage complete.

110

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.