Power Development And Non Renewable Energy Tender
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
₹ 65,000Document Cost
₹ 594Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PDNRE_12398_1Bid Award Id
ViewTender No
E-NIT nO. 94 OF 2023-24Tender Authority
Power Development And Non Renewable Energy ViewPurchaser Address
-Website
http://tenders.ladakh.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp,Vertical Type
1
-
-
11 kV Horn Gap Fuse Set 3 Phase 200A
1
-
-
95Sqmm (or 70Sqmm (2Ckt)/150Sqmm (or 95Sqmm (2Ckt)/300Sqmm (or 185Sqmm (2Ckt) Cable,1.1KV Grade,XLPE Insulated stranded conductor FRLS type.
44
-
-
11 Mtr. Long Pole,ST-410 SP56)
2
-
-
33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative,creepage distance 900mm
9
-
-
GI Channel/Angle/Flat of sizes including clamps
300
-
-
Galvinized Nuts and Bolts.
10
-
-
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,GO Set & Lightening arrestors as per IS 2629/85,GI nuts & bolts,refilled with earth enhancement materials & earth chamber made of bricks masonary with RCC Slab Cover.
3
-
-
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
3
-
-
LT Distribution box for 250KVA DTR with MCCB for incomer and SFU's for outgoing circuits
1
-
-
Wedge Connectors / PG Clamps
6
-
-
Danger Plates with Clamps
1
-
-
GI Barbed Wire for Anti Climbing
15
-
-
Cement bottoming 1:2:4 mix as per REC standards .5cum/pole
2
-
-
Painting of Poles Red Oxide
2
-
-
Painting of Poles Aluminium Paint
2
-
-
SITC of 11 KV Tr- Vector Meter Pole Mounted .oil emersed type with Suitable CT/PT
1
-
-
Construction of HT Line Supply,Installation,Testing & Commissioning of
-
-
-
SITC of 9 Mtr. Long Pole( ST-410 SP33)
12
-
-
SITC of GI V cross-arm/Channel with top Bracket including clamp suitable for 33KV Pin & Disc insulators(as per drawing & sample available with Divisional stores)
261
-
-
SITC of 50 mm² ACSR Conductor
1.44
-
-
SITC of PG Clamps for 50 mm² ACSR Conductor
3
-
-
SITC of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
36
-
-
SITC of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative,creepage distance 900mm
1
-
-
SITC of Galvanized Nuts and Bolts
12
-
-
SITC of Danger Plates with Clamps
12
-
-
SITC of Anti-Climbing Device with Clamps
12
-
-
SITC of Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
12
-
-
SITC of Red Oxide
12
-
-
SITC of Aluminium Paint
12
-
-
SITC of Cement bottoming 1:2:4 mix as per REC standards .5cum /pole
12
-
-
Construction of LT Line Supply,Installation,Testing & Commissioning of
-
-
-
SITC of 120 mm sq LT Cable (3x120+1x16+1x70mm) xlpe (1.1 KV,3+1c)
0.05
-
-
SITC of 70 mm sq LT Cable (3x70+1x16+1x50mm) xlpe (1.1 KV,3+1c)
0.1
-
-
SITC of 50 mm sq LT Cable (3x50+1x16+1x35mm) xlpe (1.1 KV,3+1c)
0.7
-
-
Mid Span Stright Through Jointing Kit for Lt Cable
5
-
-
Cable termination Kit LT
6
-
-
Excavation of any type of soil incuding hard soil size (3ftx2.5 ft)=.914 m x.762x500m)=348 cums
50
-
-
Back filling of availeble excauavted earth
25
-
-
sand for caushioning of LT Underground cable
26
-
-
Mechnical Transport of sand
27
-
-
Head load 100 mtr of sand
28
-
-
GI pipe 150 mm dia with required no of collars for road crossing inculding termination point
20
-
-
HDPE Pipe for outer dia 180 mm, inner dia 152 mm for laying of 11 KV XLPE Cable
0.6
-
-
Evaluation Notes How It Works ?