Power Development And Non Renewable Energy Tender
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
₹ 49,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PDNRE_14214_1Tender No
e-NIT No. 62 of ED Leh of 2024-25 dated 21-09-2024Tender Authority
Power Development And Non Renewable Energy ViewPurchaser Address
-Website
http://tenders.ladakh.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Supply Installation Testing and Commissioning for Creation of Sub-Stations along with laying of HT/LT Line at Nubra Section on full turnkey basis under SDP 2024-25.
BOQ Items
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
3
-
-
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
3
-
-
11 kV Horn Gap Fuse Set 3 Phase 200A
3
-
-
120 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 63KVA DTs
88
-
-
25 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 25KVA DTs
44
-
-
9 Mtr. Long Pole,ST-410 SP33)
6
-
-
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
9
-
-
GI Channel/Angle/Flat of sizes including clamps
850
-
-
Galvinized Nuts and Bolts.
24
-
-
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
9
-
-
33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
9
-
-
LT Distribution Box for 63 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 90Amp and suitable MCCBs for outgoing circuits with terminal extensions
2
-
-
TNP Swiching
1
-
-
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
6
-
-
Three Phase Trivector meter
3
-
-
Wedge Connectors/PG Clamps
18
-
-
Danger Plates with Clamps
3
-
-
GI Barbed Wire for Anti Climbing
45
-
-
Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
6
-
-
Painting of Poles Red Oxide
6
-
-
Painting of Poles Aluminium Paint
6
-
-
Sundry items like aluminium lugs, jumper binding Tape
3
-
-
Installation/Testing/Commissioning Part)
-
-
-
63 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
2
-
-
25 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
1
-
-
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
3
-
-
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
3
-
-
11 kV Horn Gap Fuse Set 3 Phase 200A
3
-
-
120 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 63KVA DTs
88
-
-
25 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 25KVA DTs
44
-
-
9 Mtr. Long Pole,ST-410 SP33)
6
-
-
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
9
-
-
GI Channel/Angle/Flat of sizes including clamps
850
-
-
Galvinized Nuts and Bolts.
24
-
-
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
9
-
-
33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
9
-
-
LT Distribution Box for 63 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 90Amp and suitable MCCBs for outgoing circuits with terminal extensions
2
-
-
TNP Swiching
1
-
-
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
6
-
-
Three Phase Trivector meter
3
-
-
Wedge Connectors/PG Clamps
18
-
-
Danger Plates with Clamps
3
-
-
GI Barbed Wire for Anti Climbing
45
-
-
Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
6
-
-
Painting of Poles Red Oxide
6
-
-
Painting of Poles Aluminium Paint
6
-
-
Sundry items like aluminium lugs, jumper binding Tape
6
-
-
Transformer Fencing
6
-
-
HT Line (Supply)
-
-
-
9 Mtr. Long Pole( ST-410 SP33)
3
-
-
GI V cross-arm with top Bracket including clamp(14.631 kg/complete V-set)
88
-
-
30 mm² ACSR Conductor
0.5
-
-
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
18
-
-
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
12
-
-
Galvinized Nuts and Bolts
3
-
-
Danger Plates with Clamps
3
-
-
Anti-Climbing Device with Clamps
3
-
-
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
3
-
-
Red Oxide
3
-
-
Aluminium Paint
3
-
-
Cement bottoming 1:2:4 mix as per REC standards .45cum /pole
3
-
-
Aluminium Jointing Sleeves
3
-
-
HT Line (Installation/Testing/Commissioning Part)
-
-
-
9 Mtr. Long Pole( ST-410 SP33)
3
-
-
GI V cross-arm with top Bracket including clamp(14.631 kg/complete V-set)
88
-
-
30 mm² ACSR Conductor
0.5
-
-
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
18
-
-
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
12
-
-
Galvinized Nuts and Bolts
3
-
-
Danger Plates with Clamps
3
-
-
Anti-Climbing Device with Clamps
3
-
-
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
3
-
-
Red Oxide
3
-
-
Aluminium Paint
3
-
-
Cement bottoming 1:2:4 mix as per REC standards .45cum /pole
3
-
-
Aluminium Jointing Sleeves
3
-
-
LT Line (Supply)
-
-
-
8 Mtr. Long Pole( ST-410 SP15)
15
-
-
GI Channel X ARM (75X40X6mm) 4ft along with GI Clamp, 50x8mm, (4ft=8Kg, 1 No. clamp=0.83Kg = total weight = 8.83 kg)
176
-
-
GI Channel X ARM (75X40X6mm) 2ft along with GI Clamp, 50x8mm, (2ft=8Kg, 1 No. clamp=0.83Kg = total weight = 4.83 kg)
96
-
-
30mm² ACSR Conductor
3.5
-
-
16kN Polymer Shackle Insulators
106
-
-
Galvinized Nuts and Bolts.
15
-
-
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
15
-
-
Red Oxide
15
-
-
Aluminium Paint
15
-
-
Cement bottoming 1:2:4 mix as per REC standards .45cum/pole
15
-
-
LT Line (Installation/Testing/Commissioning Part)
-
-
-
8 Mtr. Long Pole( ST-410 SP15)
15
-
-
GI Channel X ARM (75X40X6mm) 4ft along with GI Clamp, 50x8mm, (4ft=8Kg, 1 No. clamp=0.83Kg = total weight = 8.83 kg)
176
-
-
GI Channel X ARM (75X40X6mm) 2ft along with GI Clamp, 50x8mm, (2ft=8Kg, 1 No. clamp=0.83Kg = total weight = 4.83 kg)
96
-
-
30mm² ACSR Conductor
3.5
-
-
16kN Polymer Shackle Insulators
106
-
-
Galvinized Nuts and Bolts.
15
-
-
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
15
-
-
Red Oxide
15
-
-
Aluminium Paint
15
-
-
Cement bottoming 1:2:4 mix as per REC standards .45cum/pole
15
-
-
Evaluation Notes How It Works ?