Power Development And Non Renewable Energy Tender
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
Refer DocumentsDocument Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_PDNRE_2937_1Tender No
e NIt No. 10 of ED Leh UT Capex 2021-22Tender Authority
Power Development And Non Renewable Energy ViewPurchaser Address
-Website
http://tenders.ladakh.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
2
-
-
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
2
-
-
11 kV Horn Gap Fuse Set 3 Phase 200A
2
-
-
120 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 100KVA DTs
44
-
-
70 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 63KVA DTs
44
-
-
9 Mtr. Long Pole,ST-410 SP33)
4
-
-
33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
6
-
-
GI Channel/Angle/Flat of sizes including clamps
600
-
-
Galvinized Nuts and Bolts.
16
-
-
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
6
-
-
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
6
-
-
LT Distribution Box Out door mounting type for 3 Ph 100kVA DTR having 200A TPN isolator, 200A HRC fuse (incomer) and 6 Nos 90A SP MCCB (outgoing)
1
-
-
LT Distribution Box Out door mounting type for 3 Ph 63kVA DTR having 100A TPN isolator, 200A HRC fuse (incomer) and 6 Nos 90A SP MCCB (outgoing)
1
-
-
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
4
-
-
Wedge Connectors / PG Clamps
12
-
-
Danger Plates with Clamps
2
-
-
GI Barbed Wire for Anti Climbing
30
-
-
3-Ø, 4-Wire Trivector Meter with CT
2
-
-
Cement bottoming 1:2:4 mix as per REC standards .5cum/pole
4
-
-
Painting of Poles Red Oxide
4
-
-
Painting of Poles Aluminium Paint
4
-
-
Sundry items like aluminium lugs, Jumpers, binding Tape etc
2
-
-
Laying of 11KV Line
-
-
-
9 Mtr. Long Pole (ST-410 SP33)
5
-
-
GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set)
105
-
-
30 mm² ACSR Conductor (Single conductor length)
1
-
-
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
21
-
-
Galvinized Nuts and Bolts
5
-
-
Danger Plates with Clamps
5
-
-
Anti-Climbing device with clamps
5
-
-
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
5
-
-
Red Oxide
5
-
-
Aluminium Paint
5
-
-
Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole including muffing 0.2Mtr above the ground level plaster and curing of concrete as per drawing/Annexure "D"
5
-
-
Laying of LT Line
-
-
-
8 Mtr. Long Pole( ST-410 SP15)
13
-
-
GI Channel X ARM (75X40X6mm) 4ft along with GI Clamp, 50x8mm, (4ft=8Kg, 1 No. clamp=0.83Kg = total weight = 8.83 kg)
115
-
-
GI Channel X ARM (75X40X6mm) 2ft along with GI Clamp, 50x8mm, (2ft=4Kg, 1 No. clamp=0.83Kg = total weight = 4.83 kg)
43
-
-
16kN Polymer Shackle Insulators
70
-
-
30 mm² ACSR Conductor (Single conductor length)
2
-
-
Galvinized Nuts and Bolts.
10
-
-
Red Oxide
13
-
-
Aluminium Paint
13
-
-
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
13
-
-
Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole including muffing 0.2Mtr above the ground level plaster and curing of concrete as per drawing
13
-
-
Evaluation Notes How It Works ?