Power Development And Non Renewable Energy Tender
... More
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
₹ 1,26,100Document Cost
₹ 2,500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_PDNRE_10166_1Bid Award Id
ViewTender No
eNIT No 20 of ED Leh of 2023-24,Dated 27.06.2023Tender Authority
Power Development And Non Renewable Energy ViewPurchaser Address
-Website
http://tenders.ladakh.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply of 25 KVA,11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate
3
-
-
... More
Supply of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
6
-
-
... More
Supply of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
6
-
-
... More
Supply of 11 kV Horn Gap Fuse Set 3 Phase 200A
6
-
-
... More
Supply of 240 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
88
-
-
... More
Supply of 120 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
44
-
-
... More
Supply of 35 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
132
-
-
... More
Supply of 9 Mtr. Long Pole,ST-410 SP33)
12
-
-
... More
Supply of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
18
-
-
... More
Supply of GI Channel/Angle/Flat of sizes including clamps(100KVA DT)
1600
-
-
... More
Supply of Galvinized Nuts and Bolts.
12
-
-
... More
Supply of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
18
-
-
... More
Supply of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
18
-
-
... More
Supply of LT Distribution Box for 100kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 140 Amp (100KVA) and suitable MCCBs for outgoing circuits with terminal extensions
1
-
-
... More
Supply of LT Distribution Box for 250kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 290 Amp (250KVA) and suitable MCCBs for outgoing circuits with terminal extensions
2
-
-
... More
Supply of 32 AMP TPN Switch Disconnector fuse set
3
-
-
... More
Supply of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stayrod& 7/3.15 mm dia GI stranded wire complete
12
-
-
... More
Supply of Danger Plates with Clamps
12
-
-
... More
Supply of GI Barbed Wire for Anti Climbing
12
-
-
... More
Supply of 3-Ø, 4-Wire Trivector Meter with CT(LTCT AMR compatible)
6
-
-
... More
Supply of Painting of Poles Red Oxide
12
-
-
... More
Supply of Painting of Poles Aluminium Paint
12
-
-
... More
Supply of Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
12
-
-
... More
Installation/Testing/Commissioning (Part)
-
-
-
... More
Installation/Testing/Commissioning of 250 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or her kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
2
-
-
... More
Installation/Testing/Commissioning of 100 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or her kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
1
-
-
... More
Installation/Testing/Commissioning of 25 KVA,11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate
3
-
-
... More
Installation/Testing/Commissioning of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
6
-
-
... More
Installation/Testing/Commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
6
-
-
... More
Installation/Testing/Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A
6
-
-
... More
Installation/Testing/Commissioning of 240 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
88
-
-
... More
Installation/Testing/Commissioning of 120 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
88
-
-
... More
Installation/Testing/Commissioning of 35 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
132
-
-
... More
Installation/Testing/Commissioning of 9 Mtr. Long Pole,ST-410 SP33)
12
-
-
... More
Installation/Testing/Commissioning of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
18
-
-
... More
Installation/Testing/Commissioning of GI Channel/Angle/Flat of sizes including clamps(100KVA DT)
1600
-
-
... More
Installation/Testing/Commissioning of Galvinized Nuts and Bolts.
12
-
-
... More
Installation/Testing/Commissioning of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
18
-
-
... More
Installation/Testing/Commissioning of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
18
-
-
... More
Installation/Testing/Commissioning of LT Distribution Box for 100kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 140 Amp (100KVA) and suitable MCCBs for outgoing circuits with terminal extensions
1
-
-
... More
Installation/Testing/Commissioning of LT Distribution Box for 250kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 290 Amp (250KVA) and suitable MCCBs for outgoing circuits with terminal extensions
2
-
-
... More
Installation/Testing/Commissioning of 32 AMP TPN Switch Disconnector fuse set
3
-
-
... More
Installation/Testing/Commissioning of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stayrod& 7/3.15 mm dia GI stranded wire complete
12
-
-
... More
Installation/Testing/Commissioning of Danger Plates with Clamps
12
-
-
... More
Installation/Testing/Commissioning of GI Barbed Wire for Anti Climbing
12
-
-
... More
Installation/Testing/Commissioning of 3-Ø, 4-Wire Trivector Meter with CT(LTCT AMR compatible)
6
-
-
... More
Installation/Testing/Commissioning of Painting of Poles Red Oxide
12
-
-
... More
Installation/Testing/Commissioning of Painting of Poles Aluminium Paint
12
-
-
... More
Installation/Testing/Commissioning of Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
12
-
-
... More
HT line (Supply Part)
-
-
-
... More
9 Mtr. Long Pole,ST-410 SP33)
27
-
-
... More
GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set)
483.66
-
-
... More
GI Channel X-arm including clamps and braces for DP (80Kg/DP)
80
-
-
... More
30 mm² ACSR Conductor
4.6
-
-
... More
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
93
-
-
... More
Galvinized Nuts and Bolts
27
-
-
... More
Danger Plates with Clamps
27
-
-
... More
Anti-Climbing Device with Clamps
27
-
-
... More
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
27
-
-
... More
Red Oxide
27
-
-
... More
Aluminium Paint
27
-
-
... More
Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
27
-
-
... More
Aluminium Jointing Sleeves
3
-
-
... More
HT line (installation/Testing /Commissioning Part)
-
-
-
... More
9 Mtr. Long Pole,ST-410 SP33)
27
-
-
... More
GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set)
483.66
-
-
... More
GI Channel X-arm including clamps and braces for DP (80Kg/DP)
80
-
-
... More
30 mm² ACSR Conductor
4.6
-
-
... More
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
93
-
-
... More
Galvinized Nuts and Bolts
27
-
-
... More
Danger Plates with Clamps
27
-
-
... More
Anti-Climbing Device with Clamps
27
-
-
... More
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
27
-
-
... More
Red Oxide
27
-
-
... More
Aluminium Paint
27
-
-
... More
Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
27
-
-
... More
Aluminium Jointing Sleeves
3
-
-
... More
LT line (Supply Part)
-
-
-
... More
8 Mtr. Long Pole( ST-410 SP15)
48
-
-
... More
GI Channel X ARM (75X40X6mm) 4ft along with GI Clamp, 50x8mm, (4ft=8Kg, 1 No. clamp=0.83Kg = total weight = 8.83 kg)
195
-
-
... More
GI Channel X ARM (75X40X6mm) 2ft along with GI Clamp, 50x8mm, (2ft=4Kg, 1 No. clamp=0.83Kg = total weight = 4.83 kg)
193
-
-
... More
30mm² ACSR Conductor
6
-
-
... More
16kN Polymer Shackle Insulators
168
-
-
... More
Galvinized Nuts and Bolts.
48
-
-
... More
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
48
-
-
... More
Red Oxide
48
-
-
... More
Aluminium Paint
48
-
-
... More
Cement bottoming 1:2:4 mix as per REC standards .45cum/pole
48
-
-
... More
LT line (installation/Testing /Commissioning Part)
-
-
-
... More
8 Mtr. Long Pole( ST-410 SP15)
48
-
-
... More
GI Channel X ARM (75X40X6mm) 4ft along with GI Clamp, 50x8mm, (4ft=8Kg, 1 No. clamp=0.83Kg = total weight = 8.83 kg)
195
-
-
... More
GI Channel X ARM (75X40X6mm) 2ft along with GI Clamp, 50x8mm, (2ft=4Kg, 1 No. clamp=0.83Kg = total weight = 4.83 kg)
193
-
-
... More
30mm² ACSR Conductor
6
-
-
... More
16kN Polymer Shackle Insulators
168
-
-
... More
Galvinized Nuts and Bolts.
48
-
-
... More
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
48
-
-
... More
Red Oxide
48
-
-
... More
Aluminium Paint
48
-
-
... More
Cement bottoming 1:2:4 mix as per REC standards .45cum/pole
48
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements