Power Development And Non Renewable Energy Tender

... More
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.

Power Development And Non Renewable Energy Tender

Electrical and Electronics
Electrical Works
Eprocure
Opening Date27 Jun 2023
Closing Date13 Jul 2023
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of 25 KVA,11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate

3

-

-

... More
Supply of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type

6

-

-

... More
Supply of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type

6

-

-

... More
Supply of 11 kV Horn Gap Fuse Set 3 Phase 200A

6

-

-

... More
Supply of 240 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type

88

-

-

... More
Supply of 120 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type

44

-

-

... More
Supply of 35 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type

132

-

-

... More
Supply of 9 Mtr. Long Pole,ST-410 SP33)

12

-

-

... More
Supply of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm

18

-

-

... More
Supply of GI Channel/Angle/Flat of sizes including clamps(100KVA DT)

1600

-

-

... More
Supply of Galvinized Nuts and Bolts.

12

-

-

... More
Supply of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.

18

-

-

... More
Supply of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm

18

-

-

... More
Supply of LT Distribution Box for 100kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 140 Amp (100KVA) and suitable MCCBs for outgoing circuits with terminal extensions

1

-

-

... More
Supply of LT Distribution Box for 250kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 290 Amp (250KVA) and suitable MCCBs for outgoing circuits with terminal extensions

2

-

-

... More
Supply of 32 AMP TPN Switch Disconnector fuse set

3

-

-

... More
Supply of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stayrod& 7/3.15 mm dia GI stranded wire complete

12

-

-

... More
Supply of Danger Plates with Clamps

12

-

-

... More
Supply of GI Barbed Wire for Anti Climbing

12

-

-

... More
Supply of 3-Ø, 4-Wire Trivector Meter with CT(LTCT AMR compatible)

6

-

-

... More
Supply of Painting of Poles Red Oxide

12

-

-

... More
Supply of Painting of Poles Aluminium Paint

12

-

-

... More
Supply of Cement bottoming 1:2:4 mix as per REC standards.5cum/pole

12

-

-

... More
Installation/Testing/Commissioning (Part)

-

-

-

... More
Installation/Testing/Commissioning of 250 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or her kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate

2

-

-

... More
Installation/Testing/Commissioning of 100 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or her kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate

1

-

-

... More
Installation/Testing/Commissioning of 25 KVA,11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate

3

-

-

... More
Installation/Testing/Commissioning of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type

6

-

-

... More
Installation/Testing/Commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type

6

-

-

... More
Installation/Testing/Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A

6

-

-

... More
Installation/Testing/Commissioning of 240 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type

88

-

-

... More
Installation/Testing/Commissioning of 120 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type

88

-

-

... More
Installation/Testing/Commissioning of 35 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type

132

-

-

... More
Installation/Testing/Commissioning of 9 Mtr. Long Pole,ST-410 SP33)

12

-

-

... More
Installation/Testing/Commissioning of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm

18

-

-

... More
Installation/Testing/Commissioning of GI Channel/Angle/Flat of sizes including clamps(100KVA DT)

1600

-

-

... More
Installation/Testing/Commissioning of Galvinized Nuts and Bolts.

12

-

-

... More
Installation/Testing/Commissioning of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.

18

-

-

... More
Installation/Testing/Commissioning of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm

18

-

-

... More
Installation/Testing/Commissioning of LT Distribution Box for 100kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 140 Amp (100KVA) and suitable MCCBs for outgoing circuits with terminal extensions

1

-

-

... More
Installation/Testing/Commissioning of LT Distribution Box for 250kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 290 Amp (250KVA) and suitable MCCBs for outgoing circuits with terminal extensions

2

-

-

... More
Installation/Testing/Commissioning of 32 AMP TPN Switch Disconnector fuse set

3

-

-

... More
Installation/Testing/Commissioning of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stayrod& 7/3.15 mm dia GI stranded wire complete

12

-

-

... More
Installation/Testing/Commissioning of Danger Plates with Clamps

12

-

-

... More
Installation/Testing/Commissioning of GI Barbed Wire for Anti Climbing

12

-

-

... More
Installation/Testing/Commissioning of 3-Ø, 4-Wire Trivector Meter with CT(LTCT AMR compatible)

6

-

-

... More
Installation/Testing/Commissioning of Painting of Poles Red Oxide

12

-

-

... More
Installation/Testing/Commissioning of Painting of Poles Aluminium Paint

12

-

-

... More
Installation/Testing/Commissioning of Cement bottoming 1:2:4 mix as per REC standards.5cum/pole

12

-

-

... More
HT line (Supply Part)

-

-

-

... More
9 Mtr. Long Pole,ST-410 SP33)

27

-

-

... More
GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set)

483.66

-

-

... More
GI Channel X-arm including clamps and braces for DP (80Kg/DP)

80

-

-

... More
30 mm² ACSR Conductor

4.6

-

-

... More
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm

93

-

-

... More
Galvinized Nuts and Bolts

27

-

-

... More
Danger Plates with Clamps

27

-

-

... More
Anti-Climbing Device with Clamps

27

-

-

... More
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.

27

-

-

... More
Red Oxide

27

-

-

... More
Aluminium Paint

27

-

-

... More
Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole

27

-

-

... More
Aluminium Jointing Sleeves

3

-

-

... More
HT line (installation/Testing /Commissioning Part)

-

-

-

... More
9 Mtr. Long Pole,ST-410 SP33)

27

-

-

... More
GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set)

483.66

-

-

... More
GI Channel X-arm including clamps and braces for DP (80Kg/DP)

80

-

-

... More
30 mm² ACSR Conductor

4.6

-

-

... More
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm

93

-

-

... More
Galvinized Nuts and Bolts

27

-

-

... More
Danger Plates with Clamps

27

-

-

... More
Anti-Climbing Device with Clamps

27

-

-

... More
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.

27

-

-

... More
Red Oxide

27

-

-

... More
Aluminium Paint

27

-

-

... More
Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole

27

-

-

... More
Aluminium Jointing Sleeves

3

-

-

... More
LT line (Supply Part)

-

-

-

... More
8 Mtr. Long Pole( ST-410 SP15)

48

-

-

... More
GI Channel X ARM (75X40X6mm) 4ft along with GI Clamp, 50x8mm, (4ft=8Kg, 1 No. clamp=0.83Kg = total weight = 8.83 kg)

195

-

-

... More
GI Channel X ARM (75X40X6mm) 2ft along with GI Clamp, 50x8mm, (2ft=4Kg, 1 No. clamp=0.83Kg = total weight = 4.83 kg)

193

-

-

... More
30mm² ACSR Conductor

6

-

-

... More
16kN Polymer Shackle Insulators

168

-

-

... More
Galvinized Nuts and Bolts.

48

-

-

... More
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.

48

-

-

... More
Red Oxide

48

-

-

... More
Aluminium Paint

48

-

-

... More
Cement bottoming 1:2:4 mix as per REC standards .45cum/pole

48

-

-

... More
LT line (installation/Testing /Commissioning Part)

-

-

-

... More
8 Mtr. Long Pole( ST-410 SP15)

48

-

-

... More
GI Channel X ARM (75X40X6mm) 4ft along with GI Clamp, 50x8mm, (4ft=8Kg, 1 No. clamp=0.83Kg = total weight = 8.83 kg)

195

-

-

... More
GI Channel X ARM (75X40X6mm) 2ft along with GI Clamp, 50x8mm, (2ft=4Kg, 1 No. clamp=0.83Kg = total weight = 4.83 kg)

193

-

-

... More
30mm² ACSR Conductor

6

-

-

... More
16kN Polymer Shackle Insulators

168

-

-

... More
Galvinized Nuts and Bolts.

48

-

-

... More
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.

48

-

-

... More
Red Oxide

48

-

-

... More
Aluminium Paint

48

-

-

... More
Cement bottoming 1:2:4 mix as per REC standards .45cum/pole

48

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.