Power Development And Non Renewable Energy Tender

Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.

Power Development And Non Renewable Energy Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date24 Aug 2023
Closing Date31 Aug 2023
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of 100 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or her kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate

2

-

-

... More
Supply of 250 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or her kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate

1

-

-

... More
Supply of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type

8

-

-

... More
Supply of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type

8

-

-

... More
Supply of 11 kV Horn Gap Fuse Set 3 Phase 200A

8

-

-

... More
Supply of 70 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type

220

-

-

... More
Supply of 120 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type

88

-

-

... More
Supply of 185 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type

44

-

-

... More
Supply of Supply of 9 Mtr. Long Pole,ST-410 SP33)

16

-

-

... More
Supply of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm

24

-

-

... More
Supply of GI Channel/Angle/Flat of sizes including clamps for DP (Total 80Kg/DP)

2400

-

-

... More
Supply of Galvinized Nuts and Bolts.

64

-

-

... More
Supply of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.

16

-

-

... More
Supply of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm

39

-

-

... More
Supply of LT Distribution Box for 63 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 90 Amp and suitable MCBs for outgoing circuits with 6 terminal extensions

5

-

-

... More
Supply of LT Distribution Box for 63 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 140 Amp and suitable MCBs for outgoing circuits with 6 terminal extensions

2

-

-

... More
Supply of LT Distribution Box for 250 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 290 Amp and suitable MCBs for outgoing circuits with 6 terminal extensions

1

-

-

... More
Supply of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stayrod& 7/3.15 mm dia GI stranded wire complete

8

-

-

... More
Supply of Danger Plates with Clamps

8

-

-

... More
Supply of 3-Ø, 4-Wire Trivector Meter with CT(LTCT AMR compatible)

8

-

-

... More
Supply of Cement bottoming 1:2:4 mix as per REC standards.5cum/pole

16

-

-

... More
Supply of Painting of Poles Red Oxide

16

-

-

... More
Supply of Painting of Poles Aluminium Paint

16

-

-

... More
Supply of Sundry items like aluminium lugs, Jumpers, binding Tape,

8

-

-

... More
HT Line

-

-

-

... More
Supply of 9 Mtr. Long Pole,ST-410 SP33)

44

-

-

... More
Supply of GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set)

558

-

-

... More
Supply of GI Channel X-arm 1600mm long including clamps and braces (70x40x6mm GI Channel of 1600mm long, (weight per channel=11.42kg, back clamp for cantilever 50x8mm, 365mm long=1.15kg Total weight=12.57kg/Channel+Clamp) GI Angle 65x65x6mm, 1760mm long including clamps and braces in Kgs (65x65x6mm of 1760mm long (Weight=10.21kg, Guy clamp for cantilever 50x8mm, 300mm long=0.9kg, Total weight=11.11kg, Total weight of x-arm and cantilever=23.68Kgs)

278

-

-

... More
Supply of GI Channel X-arm including clamps and braces for DP (80Kg/DP)

320

-

-

... More
Supply of GI cut Channel X-arm 4ft including pole top channel and clamps

38

-

-

... More
Supply of 30 mm² ACSR Conductor

7

-

-

... More
Supply of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm

135

-

-

... More
Supply of 33KV Polymeric Composite Disc Insulator 36KN, min failing load 70KN, Lightining Impulse 170KV Positive and 180KV Negative, Creepage distance 900mm

27

-

-

... More
Supply of Galvinized Nuts and Bolts

44

-

-

... More
Supply of Danger Plates with Clamps

44

-

-

... More
Supply of Anti-Climbing Device with Clamps

44

-

-

... More
Supply of Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.

44

-

-

... More
Supply of Red Oxide

44

-

-

... More
Supply of Aluminium Paint

44

-

-

... More
Supply of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole

44

-

-

... More
Supply of Link set

1

-

-

... More
3ph/1ph LT Line

-

-

-

... More
Supply of 8 Mtr. Long Pole( ST-410 SP15)

59

-

-

... More
Supply of GI Channel X ARM (75X40X6mm) 4ft along with GI Clamp, 50x8mm, (4ft=8Kg, 1 No. clamp=0.83Kg = total weight = 8.83 kg)

332

-

-

... More
Supply of GI Channel X ARM (75X40X6mm) 2ft along with GI Clamp, 50x8mm, (2ft=4Kg, 1 No. clamp=0.83Kg = total weight = 4.83 kg)

150

-

-

... More
Supply of 30mm² ACSR Conductor

11.5

-

-

... More
Supply of 16kN Polymer Shackle Insulators

260

-

-

... More
Supply of Galvinized Nuts and Bolts.

59

-

-

... More
Supply of Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.

59

-

-

... More
Supply of Red Oxide

59

-

-

... More
Supply of Aluminium Paint

59

-

-

... More
Supply of Cement bottoming 1:2:4 mix as per REC standards .45cum/pole

59

-

-

... More
Installation, Testing & Commissioning(LABOUR PART)

-

-

-

-

-

-

... More
Installation, Testing & Commissioning of 63 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate

5

-

-

... More
Installation, Testing & Commissioning of 100 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or her kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate

2

-

-

... More
Installation, Testing & Commissioning of 250 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or her kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate

1

-

-

... More
Installation, Testing & Commissioning of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type

8

-

-

... More
Installation, Testing & Commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type

8

-

-

... More
Installation, Testing & Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A

8

-

-

... More
Installation, Testing & Commissioning of 70 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type

220

-

-

... More
Installation, Testing & Commissioning of 120 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type

88

-

-

... More
Installation, Testing & Commissioning of 185 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type

44

-

-

... More
Installation, Testing & Commissioning of Supply of 9 Mtr. Long Pole,ST-410 SP33)

16

-

-

... More
Installation, Testing & Commissioning of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm

24

-

-

... More
Installation, Testing & Commissioning of GI Channel/Angle/Flat of sizes including clamps for DP (Total 80Kg/DP)

2400

-

-

... More
Installation, Testing & Commissioning of Galvinized Nuts and Bolts.

64

-

-

... More
Installation, Testing & Commissioning of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.

16

-

-

... More
Installation, Testing & Commissioning of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm

39

-

-

... More
Installation, Testing & Commissioning of LT Distribution Box for 63 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 90 Amp and suitable MCBs for outgoing circuits with 6 terminal extensions

5

-

-

... More
Installation, Testing & Commissioning of LT Distribution Box for 63 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 140 Amp and suitable MCBs for outgoing circuits with 6 terminal extensions

2

-

-

... More
Installation, Testing & Commissioning of LT Distribution Box for 250 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 290 Amp and suitable MCBs for outgoing circuits with 6 terminal extensions

1

-

-

... More
Installation, Testing & Commissioning of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stayrod& 7/3.15 mm dia GI stranded wire complete

8

-

-

... More
Installation, Testing & Commissioning of Danger Plates with Clamps

8

-

-

... More
Installation, Testing & Commissioning of 3-Ø, 4-Wire Trivector Meter with CT(LTCT AMR compatible)

8

-

-

... More
Installation, Testing & Commissioning of Cement bottoming 1:2:4 mix as per REC standards.5cum/pole

16

-

-

... More
Installation, Testing & Commissioning of Painting of Poles Red Oxide

16

-

-

... More
Installation, Testing & Commissioning of Painting of Poles Aluminium Paint

16

-

-

... More
Installation, Testing & Commissioning of Sundry items like aluminium lugs, Jumpers, binding Tape,

8

-

-

... More
HT Line

-

-

-

... More
Installation, Testing & Commissioning of 9 Mtr. Long Pole,ST-410 SP33)

44

-

-

... More
Installation, Testing & Commissioning of GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set)

558

-

-

... More
Installation, Testing & Commissioning of GI Channel X-arm 1600mm long including clamps and braces (70x40x6mm GI Channel of 1600mm long, (weight per channel=11.42kg, back clamp for cantilever 50x8mm, 365mm long=1.15kg Total weight=12.57kg/Channel+Clamp) GI Angle 65x65x6mm, 1760mm long including clamps and braces in Kgs (65x65x6mm of 1760mm long (Weight=10.21kg, Guy clamp for cantilever 50x8mm, 300mm long=0.9kg, Total weight=11.11kg, Total weight of x-arm and cantilever=23.68Kgs)

278

-

-

... More
Installation, Testing & Commissioning of GI Channel X-arm including clamps and braces for DP (80Kg/DP)

320

-

-

... More
Installation, Testing & Commissioning of GI cut Channel X-arm 4ft including pole top channel and clamps

38

-

-

... More
Installation, Testing & Commissioning of 30 mm² ACSR Conductor

7

-

-

... More
Installation, Testing & Commissioning of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm

135

-

-

... More
Installation, Testing & Commissioning of 33KV Polymeric Composite Disc Insulator 36KN, min failing load 70KN, Lightining Impulse 170KV Positive and 180KV Negative, Creepage distance 900mm

27

-

-

... More
Installation, Testing & Commissioning of Galvinized Nuts and Bolts

44

-

-

... More
Installation, Testing & Commissioning of Danger Plates with Clamps

44

-

-

... More
Installation, Testing & Commissioning of Anti-Climbing Device with Clamps

44

-

-

... More
Installation, Testing & Commissioning of Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.

44

-

-

... More
Installation, Testing & Commissioning of Red Oxide

44

-

-

... More
Installation, Testing & Commissioning of Aluminium Paint

44

-

-

... More
Installation, Testing & Commissioning of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole

44

-

-

... More
Installation, Testing & Commissioning of Link set

1

-

-

... More
3ph LT Line

-

-

-

... More
Installation, Testing & Commissioning of 8 Mtr. Long Pole( ST-410 SP15)

59

-

-

... More
Installation, Testing & Commissioning of GI Channel X ARM (75X40X6mm) 4ft along with GI Clamp, 50x8mm, (4ft=8Kg, 1 No. clamp=0.83Kg = total weight = 8.83 kg)

332

-

-

... More
Installation, Testing & Commissioning of GI Channel X ARM (75X40X6mm) 2ft along with GI Clamp, 50x8mm, (2ft=4Kg, 1 No. clamp=0.83Kg = total weight = 4.83 kg)

150

-

-

... More
Installation, Testing & Commissioning of 30mm² ACSR Conductor

11.5

-

-

... More
Installation, Testing & Commissioning of 16kN Polymer Shackle Insulators

260

-

-

... More
Installation, Testing & Commissioning of Galvinized Nuts and Bolts.

59

-

-

... More
Installation, Testing & Commissioning of Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.

59

-

-

... More
Installation, Testing & Commissioning of Red Oxide

59

-

-

... More
Installation, Testing & Commissioning of Aluminium Paint

59

-

-

... More
Installation, Testing & Commissioning of Cement bottoming 1:2:4 mix as per REC standards .45cum/pole

59

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.