Power Development And Non Renewable Energy Tender
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
₹ 5,60,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Summary
Supply, Installation, Testing Commissioning For Extension Of 11kv Line From Army Tapping Hanuthang Till Handangbrok Via Creation Of Sub-station
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PDNRE_12981_2Bid Award Id
ViewTender No
e-NIT No. 06 of ED Leh of 2024-25 dated 10-06-2024Tender Authority
Power Development And Non Renewable Energy ViewPurchaser Address
-Website
http://tenders.ladakh.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Supply, Installation, Testing Commissioning for Extension of 11KV Line from Army Tapping Hanuthang till Handangbrok via Creation of Sub-Station at Handangbrok Unit 1 and Unit 2 and Unit 3 on full turkey basis under Deposit Work 2024-25
BOQ Items
Supply of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
3
-
-
Supply of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
3
-
-
Supply of 11 kV Horn Gap Fuse Set 3 Phase 200A
3
-
-
Supply of 185 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 25/63/100KVA & 250KVA DTs
132
-
-
Supply of 9 Mtr. Long Pole,ST-410 SP33)
6
-
-
Supply of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
9
-
-
Supply of GI Channel/Angle/Flat of sizes including clamps
900
-
-
Supply of Galvinized Nuts and Bolts.
24
-
-
Supply of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
9
-
-
Supply of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
18
-
-
Supply of LT Distribution Box for 250kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 340 Amp (250KVA) and suitable MCCBs for outgoing circuits with terminal extensions
1
-
-
Supply of LT Distribution Box for 100kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 140 Amp (63/100/250KVA) and suitable MCCBs for outgoing circuits with terminal extensions
2
-
-
Supply of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stayrod& 7/3.15 mm dia GI stranded wire complete
6
-
-
Supply of HT Meter (20/5 complete set) (Smart Meter)
1
-
-
Supply of Three Phase Treivector meter (Smart Meter)
3
-
-
Supply of Wedge Connectors/PG Clamps
18
-
-
Supply of Danger Plates with Clamps
3
-
-
Supply of GI Barbed Wire for Anti Climbing
45
-
-
Supply of Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
6
-
-
Supply of Painting of Poles Red Oxide
6
-
-
Supply of Painting of Poles Aluminium Paint
6
-
-
Supply of Transformer fencing
3
-
-
Installation/Testing/Commissioning (Part)
-
-
-
Supply of 100 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or her kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
2
-
-
Supply of 250 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or her kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
1
-
-
Installation/Testing/Commissioning of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
3
-
-
Installation/Testing/Commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
3
-
-
Installation/Testing/Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A
3
-
-
Supply of 185 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 25/63/100KVA & 250KVA DTs
132
-
-
Installation/Testing/Commissioning of 9 Mtr. Long Pole,ST-410 SP33)
6
-
-
Installation/Testing/Commissioning of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
9
-
-
Installation/Testing/Commissioning of GI Channel/Angle/Flat of sizes including clamps(100KVA DT)
900
-
-
Installation/Testing/Commissioning of Galvinized Nuts and Bolts.
24
-
-
Installation/Testing/Commissioning of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
9
-
-
Installation/Testing/Commissioning of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
18
-
-
Supply of LT Distribution Box for 250kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 340 Amp (250KVA) and suitable MCCBs for outgoing circuits with terminal extensions
1
-
-
Supply of LT Distribution Box for 100kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 140 Amp (63/100/250KVA) and suitable MCCBs for outgoing circuits with terminal extensions
2
-
-
Installation/Testing/Commissioning of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stayrod& 7/3.15 mm dia GI stranded wire complete
6
-
-
Supply of HT Meter (20/5 complete set) (Smart Meter)
1
-
-
Supply of Three Phase Treivector meter (Smart Meter)
3
-
-
Supply of Wedge Connectors/PG Clamps
18
-
-
Installation/Testing/Commissioning of Danger Plates with Clamps
3
-
-
Installation/Testing/Commissioning of GI Barbed Wire for Anti Climbing
45
-
-
Installation/Testing/Commissioning of Painting of Poles Red Oxide
6
-
-
Installation/Testing/Commissioning of Painting of Poles Aluminium Paint
6
-
-
Installation/Testing/Commissioning of Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
6
-
-
Supply of Transformer fencing
3
-
-
HT line (Supply Part)
-
-
-
Supply of 9 Mtr. Long Pole,ST-410 SP33)
450
-
-
Supply of GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set)
4950
-
-
Supply of GI Channel X-arm 1600mm long including clamps braces (75x40x6mm) GI Channel of 1600mm long= 40 No. (weight per channel = 11.42kg, back clamp for cantilever 50x8mm, 365mm long =1.15kg Total weight = 12.57kg/channel +Clamp) GI Angle 65x65x6mm, 1760mm long including clamps and braces in kgs (65x65x6mm of 1760mm long = 40 nos. (weight = 10.21kg, Guy clamp for cantilever 50x8mm, 300mm long = 0.9kg, Total weight = 11.11kg, Ttotal weight of x-arm and cantilever = 26kgs)
3120
-
-
Supply of GI Channel X-Arm including calmps and braces for DP (80kg/DP)
6080
-
-
Supply of 30 mm² ACSR Conductor
73
-
-
Supply of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
1290
-
-
Supply of 33kV Polymeric composite Disc Insulator 36kV, min failing load 70kn, lighting impulse 170kv positive and 180kv Negative, creepage distance 900mm
490
-
-
Supply of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type for isolation while patrolling the HT line for early restoration.
25
-
-
Supply of Galvinized Nuts and Bolts
1130
-
-
Supply of Danger Plates with Clamps
450
-
-
Supply of Anti-Climbing Device with Clamps
450
-
-
Supply of Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
450
-
-
Supply of Red Oxide
450
-
-
Supply of Aluminium Paint
450
-
-
Supply of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
450
-
-
HT line (installation/Testing /Commissioning Part)
-
-
-
9 Mtr. Long Pole,ST-410 SP33)
450
-
-
GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set)
4950
-
-
Supply of GI Channel X-arm 1600mm long including clamps braces (75x40x6mm) GI Channel of 1600mm long= 40 No. (weight per channel = 11.42kg, back clamp for cantilever 50x8mm, 365mm long =1.15kg Total weight = 12.57kg/channel +Clamp) GI Angle 65x65x6mm, 1760mm long including clamps and braces in kgs (65x65x6mm of 1760mm long = 40 nos. (weight = 10.21kg, Guy clamp for cantilever 50x8mm, 300mm long = 0.9kg, Total weight = 11.11kg, Ttotal weight of x-arm and cantilever = 26kgs)
3120
-
-
GI Channel X-arm including clamps and braces for DP (80Kg/DP)
6080
-
-
30 mm² ACSR Conductor
73
-
-
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
1290
-
-
Supply of 33kV Polymeric composite Disc Insulator 36kV, min failing load 70kn, lighting impulse 170kv positive and 180kv Negative, creepage distance 900mm
490
-
-
Supply of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type for isolation while patrolling the HT line for early restoration.
25
-
-
Galvinized Nuts and Bolts
1130
-
-
Danger Plates with Clamps
450
-
-
Anti-Climbing Device with Clamps
450
-
-
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
450
-
-
Red Oxide
450
-
-
Aluminium Paint
450
-
-
Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
450
-
-
LT line (Supply Part)
-
-
-
Supply of 8 Mtr. Long Pole( ST-410 SP15)
59
-
-
Supply of GI Channel X ARM (75X40X6mm) 4ft along with GI Clamp, 50x8mm, (4ft=8Kg, 1 No. clamp=0.83Kg = total weight = 8.83 kg)
586
-
-
Supply of 50mm² ACSR Conductor
12
-
-
Supply of 16kN Polymer Shackle Insulators
285
-
-
Supply of Galvinized Nuts and Bolts.
59
-
-
Supply of Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
59
-
-
Supply of Red Oxide
59
-
-
Supply of Aluminium Paint
59
-
-
Supply of Cement bottoming 1:2:4 mix as per REC standards .45cum/pole
59
-
-
LT line (installation/Testing /Commissioning Part)
-
-
-
installation/Testing /Commissioning of 8 Mtr. Long Pole( ST-410 SP15)
59
-
-
installation/Testing /Commissioning of GI Channel X ARM (75X40X6mm) 4ft along with GI Clamp, 50x8mm, (4ft=8Kg, 1 No. clamp=0.83Kg = total weight = 8.83 kg)
586
-
-
installation/Testing /Commissioning of 50mm² ACSR Conductor
12
-
-
1installation/Testing /Commissioning of 16kN Polymer Shackle Insulators
285
-
-
installation/Testing /Commissioning of Galvinized Nuts and Bolts.
59
-
-
installation/Testing /Commissioning of Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
59
-
-
installation/Testing /Commissioning of Red Oxide
59
-
-
installation/Testing /Commissioning of Aluminium Paint
59
-
-
installation/Testing /Commissioning of Cement bottoming 1:2:4 mix as per REC standards .45cum/pole
59
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements