Power Development And Non Renewable Energy Tender
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
₹ 1,03,000Document Cost
₹ 2,500Tender Fee
Refer Documents
Summary
Sitc For Augmentn Of 250 To 400kva At Chulung 100 To 250kva At Kasar Palace Hotel 100
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PDNRE_14726_1Bid Award Id
ViewTender No
e-NIT No. 116 of ED Leh of 2024-25 dated 24-10-2024Tender Authority
Power Development And Non Renewable Energy ViewPurchaser Address
-Website
http://tenders.ladakh.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
SITC for Augmentn of 250 to 400KVA at Chulung 100 to 250KVA at Kasar Palace Hotel 100 to 250KVA at Zanang Hotel OldRoad 63 to 250KVA Near Library 100 to 250KVA Dreamland and 300 to 400KVA at Skampari Qabaristan on full turnkey basis under UT Capex 24-25
BOQ Items
11KV GO, AB Switch 3-Phase, 3-Pole, 200Amp, Vertical Type
5
-
-
11KV Horn Gap, Fuse Set 3-Phase 200A
5
-
-
185sqmm(2Ckt) Cable, 1.1KV Grade, PVC Insulated Stranded Conductors FRLS Type for 25/63/100KVA & 250KVA DTs
264
-
-
Supply of 9 Mtr. Long Pole, ST-410 SP33
2
-
-
Supply of 33KV Polymeric Composite Disc Insulator 36KN, min failing load 70KN, Lightining Impulse 170KV Positive and 180KV Negative, Creepage distance 900mm
3
-
-
Supply of GI Channel/Angle/Flat of sizes including clamps
300
-
-
Supply of Galvanized nuts and bolts
8
-
-
Supply of Earthing of Substation Excavation of Earth Pit of dia 650 mm & depth 3000mm, installation of Earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as per IS 1239. GI Strip for neutral earthing of size 25mmx3mm for connection of Transformer body, G.O set & lighting arrestor as per IS 2629/85, GI nuts & Bolts, reffilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover.
3
-
-
33KV Polymer Composite Pin Insulator 36KV, 10KN, lighting Impluse 170KV positive and 180KV negative, creepage distance 900mm
6
-
-
LT Distribution Box for 400KVA DTR with TPN MCCB short ckt rating 16KA for incommer 630Amp (400KVA) and suitable MCCBs for outgoing circuits with terminal extensions (Single Pole 3 Phase 300 Amp three Outgoing Circuits)
1
-
-
LT Distribution Box for 400KVA DTR with TPN MCCB short ckt rating 16KA for incommer 340Amp (250KVA) and suitable MCCBs for outgoing circuits with terminal extensions (Single Pole 3 Phase 200 Amp three Outgoing Circuits)
5
-
-
Galvanised Stay Set with 50x8mm stay clamp, guy Insulator(2Nos), anchor Plate(200x200x6mm), nuts-bolts, 2 Nos turn-Buckles, 1.8m long, 16mm diameter solid GS stayrods & 7/3.15 mm dia GI stranded wire complete
2
-
-
Wedge Connector /PG Clamps
6
-
-
Danger Plate with Clamps
5
-
-
GI Barbed Wire for Anti Climbing
15
-
-
Cement Bottoming 1:2:4 mix as per REC standards .5cum/pole
2
-
-
Painting of poles Red Oxide
2
-
-
Painting of poles Aluminium Paint
2
-
-
Sundry items like Aluminium lugs, Jumper, binding Tape
6
-
-
Transformer Bed
1
-
-
Transformer fencing
4
-
-
(Labour part)
-
-
-
400 KVA, 11/0.433KV. 3-Phase Distribution Transformers with bimetallic Terminal Connector Energy Level-2, (Aluminium wound upto 200KVA, Copper Wound for 250KVA or her KVA ratings), and with LV Cable Box having detachable Aluminium Gland Plate.
2
-
-
250 KVA, 11/0.433KV. 3-Phase Distribution Transformers with bimetallic Terminal Connector Energy Level-2, (Aluminium wound upto 200KVA, Copper Wound for 250KVA or her KVA ratings), and with LV Cable Box having detachable Aluminium Gland Plate.
4
-
-
11KV GO, AB Switch 3-Phase, 3-Pole, 200Amp, Vertical Type
5
-
-
11KV Horn Gap, Fuse Set 3-Phase 200A
5
-
-
185sqmm(2Ckt) Cable, 1.1KV Grade, PVC Insulated Stranded Conductors FRLS Type for 25/63/100KVA & 250KVA DTs
264
-
-
Supply of 9 Mtr. Long Pole, ST-410 SP33
2
-
-
Supply of 33KV Polymeric Composite Disc Insulator 36KN, min failing load 70KN, Lightining Impulse 170KV Positive and 180KV Negative, Creepage distance 900mm
3
-
-
Supply of GI Channel/Angle/Flat of sizes including clamps
300
-
-
Supply of Galvanized nuts and bolts
8
-
-
Supply of Earthing of Substation Excavation of Earth Pit of dia 650 mm & depth 3000mm, installation of Earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as per IS 1239. GI Strip for neutral earthing of size 25mmx3mm for connection of Transformer body, G.O set & lighting arrestor as per IS 2629/85, GI nuts & Bolts, reffilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover.
3
-
-
33KV Polymer Composite Pin Insulator 36KV, 10KN, lighting Impluse 170KV positive and 180KV negative, creepage distance 900mm
6
-
-
LT Distribution Box for 400KVA DTR with TPN MCCB short ckt rating 16KA for incommer 630Amp (400KVA) and suitable MCCBs for outgoing circuits with terminal extensions (Single Pole 3 Phase 300 Amp three Outgoing Circuits)
1
-
-
LT Distribution Box for 250KVA DTR with TPN MCCB short ckt rating 16KA for incommer 340Amp (250KVA) and suitable MCCBs for outgoing circuits with terminal extensions (Single Pole 3 Phase 200 Amp three Outgoing Circuits)
5
-
-
Galvanised Stay Set with 50x8mm stay clamp, guy Insulator(2Nos), anchor Plate(200x200x6mm), nuts-bolts, 2 Nos turn-Buckles, 1.8m long, 16mm diameter solid GS stayrods & 7/3.15 mm dia GI stranded wire complete
2
-
-
Wedge Connector /PG Clamps
6
-
-
Danger Plate with Clamps
5
-
-
GI Barbed Wire for Anti Climbing
15
-
-
Cement Bottoming 1:2:4 mix as per REC standards .5cum/pole
2
-
-
Painting of poles Red Oxide
2
-
-
Painting of poles Aluminium Paint
2
-
-
Sundry items like Aluminium lugs, Jumper, binding Tape
6
-
-
Transformer Bed
1
-
-
Transformer fencing
4
-
-
Dismentalling (Labour Part):
-
-
-
Dismentalling of existing DT structure wherever required and un-mounting of old DTs along with allied materials back to PDD Store Choglamsar
6
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements