Power Development And Non Renewable Energy Tender
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
₹ 78,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_PDNRE_10745_1Bid Award Id
ViewTender No
eNIT No. 59 of ED Leh Dated 17.08.2023Tender Authority
Power Development And Non Renewable Energy ViewPurchaser Address
-Website
http://tenders.ladakh.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply of GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set)
585
-
-
... More
Supply of GI Channel X-arm including clamps,fish plate and braces for DP (80Kg/DP)
640
-
-
... More
Supply of 30 mm² ACSR Conductor
8.2
-
-
... More
Supply of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
120
-
-
... More
Supply of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
48
-
-
... More
Supply of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
10
-
-
... More
Supply of Galvinized Nuts and Bolts
48
-
-
... More
Supply of Danger Plates with Clamps
48
-
-
... More
Supply of Anti-Climbing Device with Clamps
48
-
-
... More
Supply of Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
48
-
-
... More
Supply of Red Oxide
48
-
-
... More
Supply of Aluminium Paint
48
-
-
... More
Supply of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
90
-
-
... More
Supply of Aluminium Jointing Sleeves
48
-
-
... More
11KV HT Line (Installation,testing and commissioning of part)
-
-
-
... More
Installation,testing and commissioning of 9 Mtr. Long Pole,ST-410 SP33)
48
-
-
... More
Installation,testing and commissioning of GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set)
585
-
-
... More
Installation,testing and commissioning of GI Channel X-arm including clamps,fish plate and braces for DP (80Kg/DP)
640
-
-
... More
Installation,testing and commissioning of 30 mm² ACSR Conductor
8.2
-
-
... More
Installation,testing and commissioning of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
120
-
-
... More
Installation,testing and commissioning of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
48
-
-
... More
Installation,testing and commissioning of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
10
-
-
... More
Installation,testing and commissioning of Galvinized Nuts and Bolts
48
-
-
... More
Installation,testing and commissioning of Danger Plates with Clamps
48
-
-
... More
Installation,testing and commissioning of Anti-Climbing Device with Clamps
48
-
-
... More
Installation,testing and commissioning of Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
48
-
-
... More
Installation,testing and commissioning of Red Oxide
48
-
-
... More
Installation,testing and commissioning of Aluminium Paint
48
-
-
... More
Installation,testing and commissioning of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
90
-
-
... More
Installation,testing and commissioning of Aluminium Jointing Sleeves
48
-
-
... More
Substation Supply Part ( 25 KVA)
-
-
-
... More
Supply of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
1
-
-
... More
Supply of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
1
-
-
... More
Supply of 11 kV Horn Gap Fuse Set 3 Phase 200A
1
-
-
... More
Supply of 25 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
44
-
-
... More
Supply of 9 Mtr. Long Pole,ST-410 SP33)
2
-
-
... More
Supply of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
3
-
-
... More
Supply of GI Channel/Angle/Flat of sizes including clamps
250
-
-
... More
Supply of Galvinized Nuts and Bolts.
8
-
-
... More
Supply of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
3
-
-
... More
Supply of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
3
-
-
... More
Supply of 32/63 amps TPN Switch Disconnector Fuse Unit
1
-
-
... More
Supply of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
2
-
-
... More
Supply of Wedge Connectors / PG Clamps
3
-
-
... More
Supply of Danger Plates with Clamps
1
-
-
... More
Supply of GI Barbed Wire for Anti Climbing
15
-
-
... More
Supply of 3-Ø, 4-Wire Trivector Meter with CT
1
-
-
... More
Supply of Cement bottoming 1:2:4 mix as per REC standards .5cum/pole
2
-
-
... More
Supply of Painting of Poles Red Oxide
2
-
-
... More
Supply of Painting of Poles Aluminium Paint
2
-
-
... More
Supply of LT Distribution Box for 100kVA DTR with MCCB short circuit rating 16KA/Sec for incomer 160Amp and suitable MCCBs for Outgoing Circuits with terminal extension.
1
-
-
... More
Substation (Installation,testing and commissioning part)
-
-
-
... More
Installation,testing and commissioning of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
1
-
-
... More
Installation,testing and commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
1
-
-
... More
Installation,testing and commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A
1
-
-
... More
Installation,testing and commissioning of 25 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
44
-
-
... More
Installation,testing and commissioning of 9 Mtr. Long Pole,ST-410 SP33)
2
-
-
... More
Installation,testing and commissioning of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
3
-
-
... More
Installation,testing and commissioning of GI Channel/Angle/Flat of sizes including clamps
250
-
-
... More
Installation,testing and commissioning of Galvinized Nuts and Bolts.
8
-
-
... More
Installation,testing and commissioning of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
3
-
-
... More
Installation,testing and commissioning of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
3
-
-
... More
Installation,testing and commissioning of 32/63 amps TPN Switch Disconnector Fuse Unit
1
-
-
... More
Installation,testing and commissioning of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
2
-
-
... More
Installation,testing and commissioning of Wedge Connectors / PG Clamps
3
-
-
... More
Installation,testing and commissioning of Danger Plates with Clamps
1
-
-
... More
Installation,testing and commissioning of GI Barbed Wire for Anti Climbing
15
-
-
... More
Installation,testing and commissioning of 3-Ø, 4-Wire Trivector Meter with CT
1
-
-
... More
Installation,testing and commissioning of Cement bottoming 1:2:4 mix as per REC standards .5cum/pole
2
-
-
... More
Installation,testing and commissioning of Painting of Poles Red Oxide
2
-
-
... More
Installation,testing and commissioning of Painting of Poles Aluminium Paint
2
-
-
... More
Installation,testing and commissioning of LT Distribution Box for 100kVA DTR with MCCB short circuit rating 16KA/Sec for incomer 160Amp and suitable MCCBs for Outgoing Circuits with terminal extension.
1
-
-
... More
Substation Supply Part ( 250 KVA )
-
-
-
... More
Supply of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
1
-
-
... More
Supply of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
1
-
-
... More
Supply of 11 kV Horn Gap Fuse Set 3 Phase 200A
1
-
-
... More
Supply of 185 mm² (2Ckt) Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 250KVA DTs
15
-
-
... More
Supply of 9 Mtr. Long Pole,ST-410 SP33)
2
-
-
... More
Supply of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative creepage distance 900mm
3
-
-
... More
Supply of GI Channel/Angle/Flat of sizes including clamps
300
-
-
... More
Supply of Galvinized Nuts and Bolts.
8
-
-
... More
Supply of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
3
-
-
... More
Supply of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
3
-
-
... More
Supply of LT Distribution Box for 250kVA DTR with TPN MCCB short ckt rating 16 KA/sec for incomer 275Amp and suitable MCCBs for outgoing circuits with terminal extensions
1
-
-
... More
Supply of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI
stranded wire complete
2
-
-
... More
Supply of Wedge Connectors / PG Clamps
3
-
-
... More
Supply of Danger Plates with Clamps
2
-
-
... More
Supply of GI Barbed Wire for Anti Climbing
15
-
-
... More
Supply of 3-Ø, 4-Wire Trivector Meter with CT(LTCT AMR compatible)
1
-
-
... More
Supply of Cement bottoming 1:2:4 mix as per REC standards .5cum/pole
2
-
-
... More
Supply of Painting of Poles Red Oxide
2
-
-
... More
Supply of Painting of Poles Aluminium Paint
2
-
-
... More
Substation (Installation,testing and commissioning )( 250 KVA )
-
-
-
... More
(Installation,testing and commissioning of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
1
-
-
... More
(Installation,testing and commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
1
-
-
... More
(Installation,testing and commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A
1
-
-
... More
(Installation,testing and commissioning of 185 mm² (2Ckt) Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 250KVA DTs
15
-
-
... More
(Installation,testing and commissioning of 9 Mtr. Long Pole,ST-410 SP33)
2
-
-
... More
(Installation,testing and commissioning of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative creepage distance 900mm
3
-
-
... More
(Installation,testing and commissioning of GI Channel/Angle/Flat of sizes including clamps
300
-
-
... More
(Installation,testing and commissioning of Galvinized Nuts and Bolts.
8
-
-
... More
(Installation,testing and commissioning of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
3
-
-
... More
(Installation,testing and commissioning of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
3
-
-
... More
(Installation,testing and commissioning of LT Distribution Box for 250kVA DTR with TPN MCCB short ckt rating 16 KA/sec for incomer 275Amp and suitable MCCBs for outgoing circuits with terminal extensions
1
-
-
... More
(Installation,testing and commissioning of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI
stranded wire complete
2
-
-
... More
(Installation,testing and commissioning of Wedge Connectors / PG Clamps
3
-
-
... More
(Installation,testing and commissioning of Danger Plates with Clamps
2
-
-
... More
(Installation,testing and commissioning of GI Barbed Wire for Anti Climbing
15
-
-
... More
(Installation,testing and commissioning of 3-Ø, 4-Wire Trivector Meter with CT(LTCT AMR compatible)
1
-
-
... More
Cement bottoming 1:2:4 mix as per REC standards .5cum/pole
2
-
-
... More
Painting of Poles Red Oxide
2
-
-
... More
Painting of Poles Aluminium Paint
2
-
-
... More
11KV HT Line
-
-
-
... More
Supply of 8 Mtr. Long Pole( ST-410 SP15)
16
-
-
... More
Supply of GI Channel X ARM (75X40X6mm) 4ft along with GI Clamp, 50x8mm, (4ft=8Kg, 1 No. clamp=0.83Kg = total weight = 8.83 kg)
176
-
-
... More
Supply of 30mm² ACSR Conductor
3
-
-
... More
Supply of 16kN Polymer Shackle Insulators
64
-
-
... More
Supply of Galvinized Nuts and Bolts.
16
-
-
... More
Supply of Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
16
-
-
... More
Supply of Red Oxide
16
-
-
... More
Supply of Aluminium Paint
16
-
-
... More
Supply of Cement bottoming 1:2:4 mix as per REC standards .45cum/pole
16
-
-
... More
11KV HT Line (Installation ,Testing,Commissioning Part)
-
-
-
... More
Installation,testing and commissioning of 8 Mtr. Long Pole( ST-410 SP15)
16
-
-
... More
Installation,testing and commissioning of GI Channel X ARM (75X40X6mm) 4ft along with GI Clamp, 50x8mm, (4ft=8Kg, 1 No. clamp=0.83Kg = total weight = 8.83 kg)
176
-
-
... More
Installation,testing and commissioning of 30mm² ACSR Conductor
3
-
-
... More
Installation,testing and commissioning of 16kN Polymer Shackle Insulators
64
-
-
... More
Installation,testing and commissioning of Galvinized Nuts and Bolts.
16
-
-
... More
Installation,testing and commissioning of Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
16
-
-
... More
(Installation,testing and commissioning of Painting of Red Oxide
16
-
-
... More
(Installation,testing and commissioning of Painting of Aluminium Paint
16
-
-
... More
Installation,testing and commissioning of Cement bottoming 1:2:4 mix as per REC standards .45cum/pole
16
-
-
... More
Dismantling, Shifting and Re-errection
-
-
-
... More
Dismentalling of ST Pole 8mtr with allied material including conductor and carraige of same to divisional store at choglamsar leh
39
-
-
... More
Dismentalling Shifitng and re-erection of existing 9 mtr by an average distance of ( 5-7 ) Mtr along with allied pole accessories ( except conductor & cement bottoming )
42
-
-
... More
Dismentalling ,shifting and Re- stringing of existing overhead weasel conductor on the re-erected 9 Mtr ST poles situated at Avearge distance of 5.7 mtr
2
-
-
... More
Dismentalling of the existing DT structure ,Carraige and W/B of the same to division store Leh ( 25 KVA )
1
-
-
... More
Dismentalling of the existing DT structure ,Carraige and W/B of the same to division store Leh ( 250 KVA )
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements