Power Development And Non Renewable Energy Tender
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
₹ 68,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Summary
Supply, Installation, Testing And Commissioning For Creation Of 100kva Sub-station At Mangalshak Chuchot
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PDNRE_13391_1Bid Award Id
ViewTender No
e-NIT No. 21 of ED Leh of 2024-25 dated 13-07-2024Tender Authority
Power Development And Non Renewable Energy ViewPurchaser Address
-Website
http://tenders.ladakh.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Supply, Installation, Testing and Commissioning for Creation of 100KVA Sub-Station at Mangalshak Chuchot Gongma and 250KVA Sub-Station at Shamirong Chuchot Shamma along with laying of HT/LT Line in Leh District on full turnkey basis under UT Capex 2024-25
BOQ Items
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
2
-
-
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp,Vertical Type
2
-
-
11 kV Horn Gap Fuse Set 3 Phase 200A
2
-
-
185 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 25/63/100kva & 250KVA DTs
88
-
-
9 Mtr. Long Pole,ST-410 SP33)
4
-
-
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 900mm
6
-
-
GI Channel/Angle/Flat of sizes including clamps
600
-
-
Galvinized Nuts and Bolts.
16
-
-
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
6
-
-
33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 900mm
12
-
-
LT Distribution Box for 100 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 140Amp and suitable MCCBs for outgoing circuits with terminal extensions
1
-
-
LT Distribution Box for 250 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 340Amp (250KVA) and suitable MCCBs for outgoing circuits with terminal extensions
1
-
-
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
4
-
-
Three Phase Trivector meter
2
-
-
Wedge Connectors/PG Clamps
12
-
-
Danger Plates with Clamps
2
-
-
GI Barbed Wire for Anti Climbing
30
-
-
Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
4
-
-
Painting of Poles Red Oxide
4
-
-
Painting of Poles Aluminium Paint
4
-
-
Transformer Fencing
2
-
-
Sundry items like aluminium lugs, jumper, binding Tape
2
-
-
Installation/Testing/Commissioning (Part)
-
-
-
100 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 25kVA, Copper wound for 25kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
1
-
-
250 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
1
-
-
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
2
-
-
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp,Vertical Type
2
-
-
11 kV Horn Gap Fuse Set 3 Phase 200A
2
-
-
185 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 25/63/100kva & 250KVA DTs
88
-
-
9 Mtr. Long Pole,ST-410 SP33)
4
-
-
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 900mm
6
-
-
GI Channel/Angle/Flat of sizes including clamps
600
-
-
Galvinized Nuts and Bolts.
16
-
-
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
6
-
-
33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 900mm
12
-
-
LT Distribution Box for 100 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 140Amp and suitable MCCBs for outgoing circuits with terminal extensions
1
-
-
LT Distribution Box for 250 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 340Amp (250KVA) and suitable MCCBs for outgoing circuits with terminal extensions
1
-
-
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
4
-
-
Three Phase Trivector meter
2
-
-
Wedge Connectors/PG Clamps
12
-
-
Danger Plates with Clamps
2
-
-
GI Barbed Wire for Anti Climbing
30
-
-
Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
4
-
-
Painting of Poles Red Oxide
4
-
-
Painting of Poles Aluminium Paint
4
-
-
Transformer Fencing
2
-
-
Sundry items like aluminium lugs, jumper, binding Tape
2
-
-
HT Line (Supply Part )
-
-
-
9 Mtr. Long Pole( ST-410 SP33)
13
-
-
DP Structure (80/kg)
80
-
-
GI V cross-arm with top Bracket including clamp(14.631 kg/complete V-set)
240
-
-
30 mm² ACSR Conductor
2
-
-
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
48
-
-
33kV Polymeric composite Disc Insulator 36kV, 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
12
-
-
Galvinized Nuts and Bolts
13
-
-
Danger Plates with Clamps
13
-
-
Anti-Climbing Device with Clamps
13
-
-
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
13
-
-
Red Oxide
13
-
-
Aluminium Paint
13
-
-
Cement bottoming 1:2:4 mix as per REC standards .45cum /pole
13
-
-
HT Line (Installation/Testing/Commissioning Part)
-
-
-
9 Mtr. Long Pole( ST-410 SP33)
13
-
-
DP Structure (80/kg)
80
-
-
GI V cross-arm with top Bracket including clamp(14.631 kg/complete V-set)
240
-
-
30 mm² ACSR Conductor
2
-
-
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
48
-
-
33kV Polymeric composite Disc Insulator 36kV, 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
12
-
-
Galvinized Nuts and Bolts
13
-
-
Danger Plates with Clamps
13
-
-
Anti-Climbing Device with Clamps
13
-
-
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
13
-
-
Red Oxide
13
-
-
Aluminium Paint
13
-
-
Cement bottoming 1:2:4 mix as per REC standards .45cum /pole
13
-
-
LT Line (Supply Part)
-
-
-
8 Mtr. Long Pole( ST-410 SP15)
36
-
-
GI Channel X Arm (75X40X6mm) 4ft along with GI Clamp, 50X8mm, (4ft=8KG, 1No. Clamp=0.83kg=total weight=8.83 kg)
354
-
-
30 mm² ACSR Conductor
7.2
-
-
16kN Polmer Shacle Insulators
160
-
-
Galvinized Nuts and Bolts
36
-
-
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
36
-
-
Red Oxide
36
-
-
Aluminium Paint
36
-
-
Cement bottoming 1:2:4 mix as per REC standards .45cum /pole
36
-
-
LT Line (Installation/Testing/Commissioning Part)
-
-
-
8 Mtr. Long Pole( ST-410 SP15)
36
-
-
GI Channel X Arm (75X40X6mm) 4ft along with GI Clamp, 50X8mm, (4ft=8KG, 1No. Clamp=0.83kg=total weight=8.83 kg)
354
-
-
30 mm² ACSR Conductor
7.2
-
-
16kN Polmer Shacle Insulators
160
-
-
Galvinized Nuts and Bolts
36
-
-
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
36
-
-
Red Oxide
36
-
-
Aluminium Paint
36
-
-
Cement bottoming 1:2:4 mix as per REC standards .45cum /pole
36
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements