Power Development And Non Renewable Energy Tender
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
₹ 49,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PDNRE_14750_1Bid Award Id
ViewTender No
118 of ED Leh of 2024-25Tender Authority
Power Development And Non Renewable Energy ViewPurchaser Address
-Website
http://tenders.ladakh.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Supply, Installation, Testing and Commissioning for Creation of 25KVA Sub-Stations for water lifting Pump at Stakna for Plantation and 100KVA Sub-Station at Mayur Choglamsar along with laying of HT/LT Line on full turnkey basis under UT Capex 2024-25.
BOQ Items
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
2
-
-
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
2
-
-
11 kV Horn Gap Fuse Set 3 Phase 200A
2
-
-
185 mm²(2ckt), Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 25/60/100KVA & 250KVA DTs
44
-
-
50 mm²(2ckt), Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 25/60/100KVA & 250KVA DTs
44
-
-
9 Mtr. Long Pole,ST-410 SP33)
4
-
-
33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
6
-
-
GI Channel/Angle/Flat of sizes including clamps
600
-
-
Galvinized Nuts and Bolts.
16
-
-
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
6
-
-
33kV Polymeric composite Pin Insulator 36kV,min failing load 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
12
-
-
LT Distribution Box for 100KVA DTR with TPN MCCB short ckt rating 16KA for incommer Amp 140KVA 63/100/(250KVA) and suitable MCCBs for outgoing circuits with terminal extensions
1
-
-
32 Amp TNP Switch disconnetor Fuse Unit
1
-
-
Three Phase Trivector Meter (Smart Meter)
2
-
-
Wedge Connectors/PG Clamps
12
-
-
Danger Plates with Clamps
2
-
-
GI Barbed Wire for Anti Climbing
30
-
-
Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
4
-
-
Painting of Poles Red Oxide
4
-
-
Painting of Poles Aluminium Paint
4
-
-
Sundry items like aluminium lugs, jumper binding Tape
2
-
-
Transformer Fencing
2
-
-
DT Installation/Testing/Commissioning Part)
-
-
-
100KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
1
-
-
25KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
1
-
-
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
2
-
-
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
2
-
-
11 kV Horn Gap Fuse Set 3 Phase 200A
2
-
-
185 mm²(2ckt), Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 25/60/100KVA & 250KVA DTs
44
-
-
50 mm²(2ckt), Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 25/60/100KVA & 250KVA DTs
44
-
-
9 Mtr. Long Pole,ST-410 SP33)
4
-
-
33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
6
-
-
GI Channel/Angle/Flat of sizes including clamps
600
-
-
Galvinized Nuts and Bolts.
16
-
-
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
6
-
-
33kV Polymeric composite Pin Insulator 36kV,min failing load 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
12
-
-
LT Distribution Box for 100KVA DTR with TPN MCCB short ckt rating 16KA for incommer Amp 140KVA 63/100/(250KVA) and suitable MCCBs for outgoing circuits with terminal extensions
1
-
-
32 Amp TNP Switch disconnetor Fuse Unit
1
-
-
Three Phase Trivector Meter
2
-
-
Wedge Connectors/PG Clamps
12
-
-
Danger Plates with Clamps
2
-
-
GI Barbed Wire for Anti Climbing
30
-
-
Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
4
-
-
Painting of Poles Red Oxide
4
-
-
Painting of Poles Aluminium Paint
4
-
-
Sundry items like aluminium lugs, jumper binding Tape
2
-
-
Transformer Fencing
2
-
-
HT (Supply Part)
-
-
-
9 Mtr. Long Pole,ST-410 SP33)
12
-
-
GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set)
194
-
-
GI ChannelsX-Arm including clamps and braces for DP (80kg/DP)
160
-
-
30 mm² ACSR Conductor
1.55
-
-
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
39
-
-
33kV Polymeric composite Disc Insulator 36kV, min failing load 70KN Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
24
-
-
Galvinized Nuts and Bolts
28
-
-
Danger Plates with Clamps
12
-
-
Anti-Climbing Device with Clamps
12
-
-
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
12
-
-
Red Oxide
12
-
-
Aluminium Paint
12
-
-
Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
12
-
-
11KV Link Set 200A
3
-
-
HT Line (Installation/Testing/Commissioning Part)
-
-
-
9 Mtr. Long Pole,ST-410 SP33)
12
-
-
GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set)
194
-
-
GI ChannelsX-Arm including clamps and braces for DP (80kg/DP)
160
-
-
30 mm² ACSR Conductor
1.55
-
-
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
39
-
-
33kV Polymeric composite Disc Insulator 36kV, min failing load 70KN Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
24
-
-
Galvinized Nuts and Bolts
28
-
-
Danger Plates with Clamps
12
-
-
Anti-Climbing Device with Clamps
12
-
-
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
12
-
-
Red Oxide
12
-
-
Aluminium Paint
12
-
-
Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
12
-
-
11KV Link Set 200A
3
-
-
LT Line (Supply Part)
-
-
-
8 Mtr. Long Pole( ST-410 SP15)
11
-
-
GI Channel X Arm (75x40x6mm) 4ft along with GI clamp, 50x8mm,(4ft=8kg, 1No. Clamp=0.83kg=total weight=8.83Kg)
106
-
-
30sqmm ACSR Conductor
2.25
-
-
16KN Polymer Shackle Insulators
56
-
-
Galvinized Nuts and Bolts
11
-
-
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
11
-
-
Red Oxide
11
-
-
Aluminium Paint
11
-
-
Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
11
-
-
LT Line (Installation/Testing/Commissioning Part)
-
-
-
8 Mtr. Long Pole( ST-410 SP15)
11
-
-
GI Channel X Arm (75x40x6mm) 4ft along with GI clamp, 50x8mm,(4ft=8kg, 1No. Clamp=0.83kg=total weight=8.83Kg)
106
-
-
50sqmm ACSR Conductor
2.25
-
-
16KN Polymer Shackle Insulators
56
-
-
Galvinized Nuts and Bolts
11
-
-
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
11
-
-
Red Oxide
11
-
-
Aluminium Paint
11
-
-
Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
11
-
-
Evaluation Notes How It Works ?