Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
₹ 2,86,000Document Cost
₹ 3,500Tender Fee
Refer Documents
Summary
Supply, Installation, Testing And Commissioning For Creation Of Sub-station Along With Ht/lt Line
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PDNRE_14041_1Bid Award Id
ViewTender No
e-NIT No. 58 of ED Leh of 2024-25 dated 09-09-2024Tender Authority
Power Development And Non Renewable Energy ViewPurchaser Address
-Website
http://tenders.ladakh.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Supply, Installation, Testing and Commissioning for Creation of Sub-Station along with HT/LT Line in Nubra Section on full turnkey basis under District Capex 2024-25.
BOQ Items
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
8
-
-
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp,Vertical Type
8
-
-
11 kV Horn Gap Fuse Set 3 Phase 200A
8
-
-
25 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 25/63/100kva & 250KVA DTs
44
-
-
120 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 25/63/100kva & 250KVA DTs
308
-
-
9 Mtr. Long Pole,ST-410 SP33)
16
-
-
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 900mm
24
-
-
GI Channel/Angle/Flat of sizes including clamps
2350
-
-
Galvinized Nuts and Bolts.
64
-
-
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
24
-
-
33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 900mm
24
-
-
32Amp TPN switch disconnector Fuse Unit
1
-
-
LT Distribution Box for 63kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 140Amp and suitable MCCBs for outgoing circuits with terminal extensions
7
-
-
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
16
-
-
Three Phase Trivector meter
8
-
-
Wedge Connectors/PG Clamps
48
-
-
Danger Plates with Clamps
8
-
-
GI Barbed Wire for Anti Climbing
120
-
-
Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
16
-
-
Painting of Poles Red Oxide
16
-
-
Painting of Poles Aluminium Paint
16
-
-
Sundry items like aluminium lugs, jumper, binding Tape
8
-
-
Installation/Testing/Commissioning (Part)
-
-
-
25 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 25kVA, Copper wound for 25kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
1
-
-
100 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 25kVA, Copper wound for 25kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
7
-
-
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
8
-
-
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp,Vertical Type
8
-
-
11 kV Horn Gap Fuse Set 3 Phase 200A
8
-
-
25 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 25/63/100kva & 250KVA DTs
44
-
-
120 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 25/63/100kva & 250KVA DTs
308
-
-
9 Mtr. Long Pole,ST-410 SP33)
16
-
-
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 900mm
24
-
-
GI Channel/Angle/Flat of sizes including clamps
2350
-
-
Galvinized Nuts and Bolts.
64
-
-
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
24
-
-
33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 900mm
24
-
-
32Amp TPN switch disconnector Fuse Unit
1
-
-
LT Distribution Box for 63kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 140Amp and suitable MCCBs for outgoing circuits with terminal extensions
7
-
-
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
16
-
-
Three Phase Trivector meter
8
-
-
Wedge Connectors/PG Clamps
48
-
-
Danger Plates with Clamps
8
-
-
GI Barbed Wire for Anti Climbing
120
-
-
Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
16
-
-
Painting of Poles Red Oxide
16
-
-
Painting of Poles Aluminium Paint
16
-
-
Sundry items like aluminium lugs, jumper, binding Tape
8
-
-
HT Line (Supply Part )
-
-
-
9 Mtr. Long Pole( ST-410 SP33)
56
-
-
DP Structure (80/kg)
320
-
-
GI V cross-arm with top Bracket including clamp(14.631 kg/complete V-set)
819
-
-
30 mm² ACSR Conductor
7
-
-
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
168
-
-
33kV Polymeric composite Disc Insulator 36kV, 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
24
-
-
Galvinized Nuts and Bolts
56
-
-
Danger Plates with Clamps
56
-
-
Anti-Climbing Device with Clamps
56
-
-
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
56
-
-
Red Oxide
56
-
-
Aluminium Paint
56
-
-
Cement bottoming 1:2:4 mix as per REC standards .45cum /pole
56
-
-
Link Set
1
-
-
Aluminium Jointing Sleeves
14
-
-
GI Channel X Arm (75X40X6mm) 8ft along with GI Clamp, 50X8mm, (8ft=16KG, 1No. Clamp=0.83kg=total weight=16.83 kg)
32
-
-
HT Line (Installation/Testing/Commissioning Part)
-
-
-
9 Mtr. Long Pole( ST-410 SP33)
56
-
-
DP Structure (80/kg)
320
-
-
GI V cross-arm with top Bracket including clamp(14.631 kg/complete V-set)
819
-
-
30 mm² ACSR Conductor
7
-
-
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
168
-
-
33kV Polymeric composite Disc Insulator 36kV, 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
24
-
-
Galvinized Nuts and Bolts
56
-
-
Danger Plates with Clamps
56
-
-
Anti-Climbing Device with Clamps
56
-
-
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
56
-
-
Red Oxide
56
-
-
Aluminium Paint
56
-
-
Cement bottoming 1:2:4 mix as per REC standards .45cum /pole
56
-
-
Link Set
1
-
-
Aluminium Jointing Sleeves
14
-
-
GI Channel X Arm (75X40X6mm) 8ft along with GI Clamp, 50X8mm, (8ft=16KG, 1No. Clamp=0.83kg=total weight=16.83 kg)
32
-
-
LT Line (Supply Part)
-
-
-
8 Mtr. Long Pole( ST-410 SP15)
154
-
-
GI Channel X Arm (75X40X6mm) 4ft along with GI Clamp, 50X8mm, (4ft=8KG, 1No. Clamp=0.83kg=total weight=8.83 kg)
600
-
-
GI Channel X Arm (75X40X6mm) 2ft along with GI Clamp, 50X8mm, (2ft=4KG, 1No. Clamp=0.83kg=total weight=4.83 kg)
780
-
-
30 mm² ACSR Conductor
22
-
-
16kN Polmer Shacle Insulators
612
-
-
Galvinized Nuts and Bolts
154
-
-
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
154
-
-
Red Oxide
154
-
-
Aluminium Paint
154
-
-
Cement bottoming 1:2:4 mix as per REC standards .45cum /pole
154
-
-
LT Line (Installation/Testing/Commissioning Part)
-
-
-
8 Mtr. Long Pole( ST-410 SP15)
154
-
-
GI Channel X Arm (75X40X6mm) 4ft along with GI Clamp, 50X8mm, (4ft=8KG, 1No. Clamp=0.83kg=total weight=8.83 kg)
600
-
-
GI Channel X Arm (75X40X6mm) 2ft along with GI Clamp, 50X8mm, (2ft=4KG, 1No. Clamp=0.83kg=total weight=4.83 kg)
780
-
-
30 mm² ACSR Conductor
22
-
-
16kN Polmer Shacle Insulators
612
-
-
Galvinized Nuts and Bolts
154
-
-
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
154
-
-
Red Oxide
154
-
-
Aluminium Paint
154
-
-
Cement bottoming 1:2:4 mix as per REC standards .45cum /pole
154
-
-