Power Development And Non Renewable Energy Tender
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
₹ 1,14,000Document Cost
₹ 2,500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PDNRE_14219_1Tender No
e-NIT No. 64 of ED Leh of 2024-25 dated 21-09-2024Tender Authority
Power Development And Non Renewable Energy ViewPurchaser Address
-Website
http://tenders.ladakh.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Supply Installation Testing and Commissioning for Creation of 3x100KVA Substation at Ragasha Chuchot Syaldor Chuchot and Stok along with laying of HT LT Line on full turnkey basis Under SDP 2024-25
BOQ Items
Supply of 11KV GO, AB Switch 3-phase, 3-pole, 200 Asmp, Vertical Type
3
-
-
Supply of 11 kV Horn Gap Fuse Set 3 Phase 200A
3
-
-
Supply of 185 mm² Cable,1.1kV Grade, PVC XLPE unarmoured FRLS type
132
-
-
Supply of 9 Mtr. Long Pole,ST-410 SP33)
6
-
-
Supply of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
9
-
-
Supply of GI Channel/Angle/Flat of sizes including clamps
900
-
-
Supply of Galvinized Nuts and Bolts.
24
-
-
Supply of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
9
-
-
Supply of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
18
-
-
LT Distribution Box for 100 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 340Amp (250KVA) and suitable MCCBs for outgoing circuits with terminal extensions
3
-
-
Supply of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stayrod& 7/3.15 mm dia GI stranded wire complete
6
-
-
Supply of Three Phase Treivector meter (Smart Meter)
3
-
-
Supply of Wedge Connectors/PG Clamps
18
-
-
Supply of Danger Plates with Clamps
3
-
-
Supply of GI Barbed Wire for Anti Climbing
45
-
-
Supply of Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
6
-
-
Supply of Painting of Poles Red Oxide
6
-
-
Supply of Painting of Poles Aluminium Paint
6
-
-
Supply of Painting of Poles Aluminium Paint
6
-
-
Transformer fencing
3
-
-
Installation/Testing/Commissioning (Part)
-
-
-
Supply of 100 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or her kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
3
-
-
Supply of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
3
-
-
Supply of 11KV GO, AB Switch 3-phase, 3-pole, 200 Asmp, Vertical Type
3
-
-
Supply of 11 kV Horn Gap Fuse Set 3 Phase 200A
3
-
-
Supply of 185 mm² Cable,1.1kV Grade, PVC XLPE unarmoured FRLS type
132
-
-
Supply of 9 Mtr. Long Pole,ST-410 SP33)
6
-
-
Supply of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
9
-
-
Supply of GI Channel/Angle/Flat of sizes including clamps
900
-
-
Supply of Galvinized Nuts and Bolts.
24
-
-
Supply of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
9
-
-
Supply of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
18
-
-
LT Distribution Box for 100 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 340Amp (250KVA) and suitable MCCBs for outgoing circuits with terminal extensions
3
-
-
Supply of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stayrod& 7/3.15 mm dia GI stranded wire complete
6
-
-
Supply of Three Phase Treivector meter (Smart Meter)
3
-
-
Supply of Wedge Connectors/PG Clamps
18
-
-
Supply of Danger Plates with Clamps
3
-
-
Supply of GI Barbed Wire for Anti Climbing
45
-
-
Supply of Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
6
-
-
Supply of Painting of Poles Red Oxide
6
-
-
Supply of Painting of Poles Aluminium Paint
6
-
-
Supply of Painting of Poles Aluminium Paint
6
-
-
Transformer fencing
3
-
-
HT line (Supply Part)
-
-
-
Supply of 9 Mtr. Long Pole,ST-410 SP33)
29
-
-
Supply of GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set)
270
-
-
Supply of 30 mm² ACSR Conductor
4.34
-
-
Supply of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
99
-
-
Supply of 33kV Polymeric composite Disc Insulator 36kV, min failing load 70kn, lighting impulse 170kv positive and 180kv Negative, creepage distance 900mm
30
-
-
Supply of Galvinized Nuts and Bolts
29
-
-
Supply of Danger Plates with Clamps
29
-
-
Supply of Anti-Climbing Device with Clamps
29
-
-
Supply of Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
29
-
-
Supply of Red Oxide
29
-
-
Supply of Aluminium Paint
29
-
-
Supply of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
29
-
-
Supply of Link Set
3
-
-
HT line (installation/Testing /Commissioning Part)
-
-
-
Installation/Testing/Commissioning of 9 Mtr. Long Pole,ST-410 SP33)
29
-
-
Installation/Testing/Commissioning of GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set)
270
-
-
Installation/Testing/Commissioning of 50 mm² ACSR Conductor
4.34
-
-
Installation/Testing/Commissioning of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
99
-
-
Installation/Testing/Commissioning of 33kV Polymeric composite Disc Insulator 36kV, min failing load 70kn, lighting impulse 170kv positive and 180kv Negative, creepage distance 900mm
30
-
-
Installation/Testing/Commissioning of Galvinized Nuts and Bolts
29
-
-
Installation/Testing/Commissioning of Danger Plates with Clamps
29
-
-
Installation/Testing/Commissioning of Anti-Climbing Device with Clamps
29
-
-
Installation/Testing/Commissioning of Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
29
-
-
Installation/Testing/Commissioning of Red Oxide
29
-
-
Installation/Testing/Commissioning of Aluminium Paint
29
-
-
Installation/Testing/Commissioning of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
29
-
-
installation of Link Set
3
-
-
LT 3-phase/1-phase (Supply Part)
-
-
-
Supply of 8 Mtr. Long Pole( ST-410 SP15)
44
-
-
Supply of GI Channel X-arm (75x40x6mm) 4ft along with GI Clamp, 50x8mm, (4ft=8.83kg, 1No Clamp = 0.83Kg=total weight = 8.83kg)
362
-
-
Supply of GI Channel X-arm (75x40x6mm) 2ft along with GI Clamp, 50x8mm, (2ft=8.83kg, 1No Clamp = 0.83Kg=total weight = 4.83kg)
37
-
-
Supply of 30mmsq ACSR Conductor
7.6
-
-
Supply of 16KN Polymer Shackle Insulator
180
-
-
Supply of Galvinized Nuts and Bolts.
44
-
-
Supply of Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
44
-
-
Supply of Red Oxide
44
-
-
Supply of Aluminium Paint
44
-
-
Supply of Cement bottoming 1:2:4 mix as per REC standards .45cum/pole
44
-
-
LT line (installation/Testing /Commissioning Part)
-
-
-
installation of 8 Mtr. Long Pole( ST-410 SP15)
44
-
-
installation of GI Channel X-arm (75x40x6mm) 4ft along with GI Clamp, 50x8mm, (4ft=8.83kg, 1No Clamp = 0.83Kg=total weight = 8.83kg)
362
-
-
installation of GI Channel X-arm (75x40x6mm) 2ft along with GI Clamp, 50x8mm, (2ft=8.83kg, 1No Clamp = 0.83Kg=total weight = 4.83kg)
37
-
-
installation of 30mmsq ACSR Conductor
7.6
-
-
installation of 16KN Polymer Shackle Insulator
180
-
-
installation of Galvinized Nuts and Bolts.
44
-
-
installation of Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
44
-
-
installation of Red Oxide
44
-
-
installation of Aluminium Paint
44
-
-
installation of Cement bottoming 1:2:4 mix as per REC standards .45cum/pole
44
-
-
Evaluation Notes How It Works ?