Power Development And Non Renewable Energy Tender
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
₹ 30,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Summary
Supply, Installation, Testing And Commissioning For Creation Of 100kva Sub-station Along With Laying Of Ht/lt Line
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PDNRE_14942_1Tender No
e-NIT No. 125 of ED Leh of 2024-25 dated 13-11-2024Tender Authority
Power Development And Non Renewable Energy ViewPurchaser Address
-Website
http://tenders.ladakh.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Supply, Installation, Testing and Commissioning for Creation of 100KVA Sub-Station along with laying of HT/LT Line at SRMC Skurbuchan on full turnkey basis under Deposit Work 2024-25.
BOQ Items
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
1
-
-
11 kV Horn Gap Fuse Set 3 Phase 200A
1
-
-
185 mm²(2ckt), Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 25/60/100KVA & 250KVA DTs
44
-
-
9 Mtr. Long Pole,ST-410 SP33)
2
-
-
33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
6
-
-
GI Channel/Angle/Flat of sizes including clamps
300
-
-
Galvinized Nuts and Bolts.
8
-
-
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
3
-
-
33kV Polymeric composite Pin Insulator 36kV,min failing load 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
6
-
-
LT Distribution Box for 100KVA DTR with TPN MCCB short ckt rating 16KA for incommer Amp 140KVA 63/100/(250KVA) and suitable MCCBs for outgoing circuits with terminal extensions
1
-
-
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
3
-
-
Three Phase Trivector Meter (Smart Meter) LT Meter
1
-
-
Wedge Connectors/PG Clamps
2
-
-
Danger Plates with Clamps
1
-
-
GI Barbed Wire for Anti Climbing
15
-
-
Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
2
-
-
Painting of Poles Red Oxide
2
-
-
Painting of Poles Aluminium Paint
2
-
-
Sundry items like aluminium lugs, jumper binding Tape
2
-
-
Transformer Fencing
1
-
-
DT Installation/Testing/Commissioning Part)
-
-
-
100KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
1
-
-
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
1
-
-
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
1
-
-
11 kV Horn Gap Fuse Set 3 Phase 200A
1
-
-
185 mm²(2ckt), Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 25/60/100KVA & 250KVA DTs
44
-
-
9 Mtr. Long Pole,ST-410 SP33)
2
-
-
33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
6
-
-
GI Channel/Angle/Flat of sizes including clamps
300
-
-
Galvinized Nuts and Bolts.
8
-
-
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
3
-
-
33kV Polymeric composite Pin Insulator 36kV,min failing load 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
6
-
-
LT Distribution Box for 100KVA DTR with TPN MCCB short ckt rating 16KA for incommer Amp 140KVA 63/100/(250KVA) and suitable MCCBs for outgoing circuits with terminal extensions
1
-
-
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
3
-
-
Three Phase Trivector Meter (Smart Meter) LT Meter
1
-
-
Wedge Connectors/PG Clamps
2
-
-
Danger Plates with Clamps
2
-
-
GI Barbed Wire for Anti Climbing
15
-
-
Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
2
-
-
Painting of Poles Red Oxide
2
-
-
Painting of Poles Aluminium Paint
2
-
-
Sundry items like aluminium lugs, jumper binding Tape
2
-
-
Transformer Fencing
1
-
-
Link Set
2
-
-
HT (Supply Part)
-
-
-
9 Mtr. Long Pole,ST-410 SP33)
1
-
-
GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set)
30
-
-
30 mm² ACSR Conductor
0.5
-
-
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
9
-
-
33kV Polymeric composite Disc Insulator 36kV, min failing load 70KN Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
6
-
-
Galvinized Nuts and Bolts
2
-
-
Danger Plates with Clamps
1
-
-
Anti-Climbing Device with Clamps
1
-
-
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
1
-
-
Red Oxide
1
-
-
Aluminium Paint
1
-
-
Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
1
-
-
HT Line (Installation/Testing/Commissioning Part)
-
-
-
9 Mtr. Long Pole,ST-410 SP33)
1
-
-
GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set)
30
-
-
30 mm² ACSR Conductor
0.5
-
-
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
9
-
-
33kV Polymeric composite Disc Insulator 36kV, min failing load 70KN Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
6
-
-
Galvinized Nuts and Bolts
2
-
-
Danger Plates with Clamps
1
-
-
Anti-Climbing Device with Clamps
1
-
-
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
1
-
-
Red Oxide
1
-
-
Aluminium Paint
1
-
-
Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
1
-
-
LT Line (Supply Part)
-
-
-
50sqmm LT AB Cable
400
-
-
8 Mtr. Long Pole( ST-410 SP15)
2
-
-
Suspension fitting (Eye Hook, Clamp for eye hook)
3
-
-
Tension fitting
3
-
-
Galvinized Nuts and Bolts
2
-
-
Danger Plates with Clamps
2
-
-
Anti-Climbing Device with Clamps
2
-
-
Earthing Complete by GI Pipe 40mm 3Mtr long through GI Strip 25x3mm.
2
-
-
Red Oxide
2
-
-
Aluminium Paint
2
-
-
Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
2
-
-
SMDB
2
-
-
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
2
-
-
Service Cable Single Core 35sqmm
20
-
-
Service Line 3.5 Core 16sqmm
40
-
-
Service Line 2 Core 10sqmm
20
-
-
IPC
16
-
-
LT Line (Installation/Testing/Commissioning Part)
-
-
-
50sqmm LT AB Cable
400
-
-
8 Mtr. Long Pole( ST-410 SP15)
2
-
-
Suspension fitting (Eye Hook, Clamp for eye hook)
3
-
-
Tension fitting
3
-
-
Galvinized Nuts and Bolts
2
-
-
Danger Plates with Clamps
2
-
-
Anti-Climbing Device with Clamps
2
-
-
Earthing Complete by GI Pipe 40mm 3Mtr long through GI Strip 25x3mm.
2
-
-
Red Oxide
2
-
-
Aluminium Paint
2
-
-
Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
2
-
-
SMDB
2
-
-
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
2
-
-
Service Cable Single Core 35sqmm
20
-
-
Service Line 3.5 Core 16sqmm
40
-
-
Service Line 2 Core 10sqmm
20
-
-
IPC
16
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%