Power Development And Non Renewable Energy Tender
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
₹ 1,05,000Document Cost
₹ 2,500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PDNRE_14240_1Tender No
e-NIT No. 66 of ED Leh of 2024-25 dated 23-09-2024Tender Authority
Power Development And Non Renewable Energy ViewPurchaser Address
-Website
http://tenders.ladakh.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Supply Installation Testing and Commissioning for Creation of Substation along with laying of HT LT line at various location of Changthang Section on full turnkey basis under District Capex 2024-45
BOQ Items
Supply of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
4
-
-
Supply of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
4
-
-
Supply of 11 kV Horn Gap Fuse Set 3 Phase 200A
4
-
-
Supply of 120 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
176
-
-
Supply of Supply of 9 Mtr. Long Pole,ST-410 SP33)
8
-
-
Supply of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
12
-
-
Supply of GI Channel/Angle/Flat of sizes including clamps for DP (Total 80Kg/DP)
1200
-
-
Supply of Galvinized Nuts and Bolts.
32
-
-
Supply of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
12
-
-
Supply of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
12
-
-
Supply of LT Distribution Box for 63 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 90 Amp and suitable MCBs for outgoing circuits with 6 terminal extensions
2
-
-
Supply of LT Distribution Box for 100 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 140Amp and suitable MCBs for outgoing circuits with 6 terminal extensions
2
-
-
Supply of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stayrod& 7/3.15 mm dia GI stranded wire complete
8
-
-
Supply of Danger Plates with Clamps
4
-
-
Supply of 3-Ø, 4-Wire Trivector Meter with CT(LTCT AMR compatible)
4
-
-
Supply of Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
8
-
-
Supply of Painting of Poles Red Oxide
8
-
-
Supply of Painting of Poles Aluminium Paint
8
-
-
Supply of Sundry items like aluminium lugs, Jumpers, binding Tape,
4
-
-
Installation, Testing & Commissioning (LABOUR PART)
-
-
-
63 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
2
-
-
Supply of 100 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or her kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
2
-
-
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
4
-
-
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
4
-
-
11 kV Horn Gap Fuse Set 3 Phase 200A
4
-
-
120 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
176
-
-
Supply of 9 Mtr. Long Pole,ST-410 SP33)
8
-
-
33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
12
-
-
Supply of GI Channel/Angle/Flat of sizes including clamps for DP (Total 80Kg/DP)
1200
-
-
Galvinized Nuts and Bolts.
32
-
-
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
12
-
-
Supply of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
12
-
-
LT Distribution Box for 63 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 90 Amp and suitable MCBs for outgoing circuits with 6 terminal extensions
2
-
-
LT Distribution Box for 100 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 140Amp and suitable MCBs for outgoing circuits with 6 terminal extensions
2
-
-
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stayrod& 7/3.15 mm dia GI stranded wire complete
8
-
-
Danger Plates with Clamps
4
-
-
3-Ø, 4-Wire Trivector Meter with CT(LTCT AMR compatible)
4
-
-
Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
8
-
-
Painting of Poles Red Oxide
8
-
-
Painting of Poles Aluminium Paint
8
-
-
Sundry items like aluminium lugs, Jumpers, binding Tape,
4
-
-
Supply of HT Line
-
-
-
Supply of 9 Mtr. Long Pole,ST-410 SP33)
24
-
-
Supply of GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set)
440
-
-
Supply of GI Channel X-arm including clamps and braces for DP (80Kg/DP)
300
-
-
Supply of 30 mm² ACSR Conductor
4
-
-
Supply of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
90
-
-
Supply of 33KV Polymeric Composite Disc Insulator 36KN, min failing load 70KN, Lightining Impulse 170KV Positive and 180KV Negative, Creepage distance 900mm
12
-
-
Supply of Galvinized Nuts and Bolts
24
-
-
Supply of Danger Plates with Clamps
24
-
-
Supply of Anti-Climbing Device with Clamps
24
-
-
Supply of Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
24
-
-
Supply of Red Oxide
24
-
-
Supply of Aluminium Paint
35
-
-
Supply of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
24
-
-
HT Line (Labour part)
-
-
-
9 Mtr. Long Pole,ST-410 SP33)
24
-
-
GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set)
440
-
-
Supply of GI Channel X-arm including clamps and braces for DP (80Kg/DP)
300
-
-
30 mm² ACSR Conductor
4
-
-
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
90
-
-
33KV Polymeric Composite Disc Insulator 36KN, min failing load 70KN, Lightining Impulse 170KV Positive and 180KV Negative, Creepage distance 900mm
12
-
-
Supply of Galvinized Nuts and Bolts
24
-
-
Danger Plates with Clamps
24
-
-
Anti-Climbing Device with Clamps
24
-
-
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
24
-
-
Red Oxide
24
-
-
Aluminium Paint
35
-
-
Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
24
-
-
Supply of 3ph/1ph LT Line
-
-
-
Supply of 8 Mtr. Long Pole( ST-410 SP15)
34
-
-
Supply of GI Channel X ARM (75X40X6mm) 4ft along with GI Clamp, 50x8mm, (4ft=8Kg, 1 No. clamp=0.83Kg = total weight = 8.83 kg)
219
-
-
Supply of GI Channel X ARM (75X40X6mm) 2ft along with GI Clamp, 50x8mm, (2ft=4Kg, 1 No. clamp=0.83Kg = total weight = 4.83 kg)
99
-
-
Supply of 30mm² ACSR Conductor
5.2
-
-
Supply of 16kN Polymer Shackle Insulators
120
-
-
Supply of Galvinized Nuts and Bolts.
24
-
-
Supply of Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
24
-
-
Supply of Red Oxide
24
-
-
Supply of Aluminium Paint
24
-
-
Supply of Cement bottoming 1:2:4 mix as per REC standards .45cum/pole
24
-
-
3ph LT Line (Labour part)
-
-
-
Installation, Testing & Commissioning of 8 Mtr. Long Pole( ST-410 SP15)
34
-
-
Installation, Testing & Commissioning of GI Channel X ARM (75X40X6mm) 4ft along with GI Clamp, 50x8mm, (4ft=8Kg, 1 No. clamp=0.83Kg = total weight = 8.83 kg)
219
-
-
Installation, Testing & Commissioning of GI Channel X ARM (75X40X6mm) 2ft along with GI Clamp, 50x8mm, (2ft=4Kg, 1 No. clamp=0.83Kg = total weight = 4.83 kg)
99
-
-
Installation, Testing & Commissioning of 30mm² ACSR Conductor
5.2
-
-
Installation, Testing & Commissioning of 16kN Polymer Shackle Insulators
120
-
-
Installation, Testing & Commissioning of Galvinized Nuts and Bolts.
24
-
-
Installation, Testing & Commissioning of Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
24
-
-
Installation, Testing & Commissioning of Red Oxide
24
-
-
Installation, Testing & Commissioning of Aluminium Paint
24
-
-
Installation, Testing & Commissioning of Cement bottoming 1:2:4 mix as per REC standards .45cum/pole
24
-
-