National Projects Construction Corporation Limited Tender
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
Refer DocumentsDocument Cost
₹ 11,800Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_NPCC_73187_1Bid Award Id
ViewTender No
NPCC/NZ-J/PHQ-Leh/Agling /2020-21/532Tender Authority
National Projects Construction Corporation Limited ViewPurchaser Address
-Website
http://http://npcc.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
2057.53
-
-
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
-
-
-
All kinds of soil
543
-
-
Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete.
19.99
-
-
Sub - Head - II , Concrete Work
-
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
-
-
-
1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
82.71
-
-
Sub - Head - III , RCC Work
-
-
-
Centering and shuttering including strutting, propping etc. and removal of form for :
-
-
-
Foundations, footings, bases of columns, etc. for mass concrete.
732
-
-
Walls ( any thickness) including attached pilasters, butteresses, plinth and string courses etc.
650.56
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Mild steel and Medium Tensile steel bars
43166.07
-
-
Providing and laying in position specified grade of reinforced, cement concrete excluding the cost of centering, shuttering,(RCC) Finishing and reinforcement – All work upto plinth level. 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone
481.75
-
-
Sub- Head - IV , Steel Work
-
-
-
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
158311.5
-
-
Structural steel work in single section fixed with connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
5413.5
-
-
Providing and fixing M.S. round holding downs bolts, nuts and washer plates complete.
16991.5
-
-
NS - 1: Providing and fixing steel, main hole cover
1
-
-
Sub- Head - V Flooring
-
-
-
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
-
-
-
52 mm thick with 20 mm nominal size stone aggregate
228.69
-
-
Sub- Head - VI Roofing
-
-
-
Providing and fixing UV stabilized fiberglass reinforced plastic sheet roofing up to any pitch including fixing with polymer coated ’j’ or ‘L’ hooks, bolts and nuts 8mm dia. G.I plain/ bitumen washers complete but exceeding the cost of purlins, rafters, trusses etc. the sheet shall be manufactured out of 2400 TEX paneirovigs incorporating minimum 0.3% Ultra-violet stabilizer in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS: 10192 and IS: 12866. The sheets shall be opaque or translucent, clear or pigmented texture or smooth as specified.
6185.75
-
-
Sub- Head - VII Finishing
-
-
-
12 mm cement plaster of mix :
-
-
-
12 mm cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement
127.85
-
-
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. 13.52.1 On steel work
3466.25
-
-
Sub- Head - VIII , Water Proofing
-
-
-
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C kitchen and the like consisting of :
310.37
-
-
Sub Head – IX Water Supply
-
-
-
NS - 2: Laying of GI pipe 100 mm dia for inlet, outlet washout , overflow and air vent, along with hold fast etc.
50
-
-
NS - 3: Providing and fixing GI sheets strips in construction joints 50 Sq. m.
50
-
-
SUB HEAD- X Tubewell(2 nos.)
-
-
-
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.
-
-
-
All types of soil
-
-
-
300 mm dia (2.nos)
200
-
-
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.(2.nos)
40
-
-
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineerin-charge.(2.nos)
6
-
-
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. (Quantity of pipes of indicated in quanty is indicative. Exact depth will be ascertened as per water aquifer of site)
-
-
-
200 mm nominal size dia having minimum wall thickness 5.40 mm(2.nos)
160
-
-
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. (Quantity of pipes of indicated in quanty is indicative. Exact depth will be ascertened as per water aquifer of site)
-
-
-
200 mm nominal size dia(2.nos)
40
-
-
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. (Quantity given is indicated in quantity is indicative. Exact time of development quality of water aquifer of site)(2.nos)
80
-
-
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:
-
-
-
200 mm clamp
2
-
-
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.
-
-
-
200 mm clamp
2
-
-
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).
-
-
-
200 mm clamp.
2
-
-
Providing and fixing single / multistage submersible tubewell pump suitable for 150mm bore with stainless steel casing, NORYL impeller, stainless steel shaft and built in non return valve coupled with submersible squirrel cage motors suitable for 145V ± 10% volts. 3 phase, 50 cycles AC supply
-
-
-
Capacity 400 lpm (Capacity of pump is selected considering yield of borewell as 30000 lph (500 lpm). The contractor shall explore yield of borewell and selected pump capacity as 80% of yield before quoting.).
-
-
-
NS - 4: Head 110m to 120m
4
-
-
Head may vary depdending upon depth of auqafire of site. The agency to quote accordingly
-
-
-
NS - 5: Providing and fixing 80mm dia GI column pipe of heavy class duly flanged(2.nos)
200
-
-
NS - 6: Providing and fixing gunmetal pressure gauge (100mm dia) of rating (0-10 kg/cm2) with gunmetal isolating cock and connecting pipe.
2
-
-
NS - 7: Providing and fixing 80mm cable clips with nuts & bolts.
80
-
-
NS - 8: Providing and fixing 80mm dia supporting clamps with nuts and bolts.
2
-
-
NS - 9: Providing and fixing 3C - 10 sq.m submersible cable. (Quantity of cable may vary depding upon the the depth of water aquafire at site.)(2.nos)
200
-
-
Providing and fixing Butterfly valve of cast body with stainless steel disc and stainless steel stem, teflon bushing and niterite o'rings.
-
-
-
NS - 10: 80mm dia
2
-
-
NS - 11: Providing and fixing steel wire rope 6mm dia complete with wire rope clamps for safety of pump set.(2.nos)
200
-
-
Supplying & laying 1.1KV grade aluminium conductor PVC insulated and PVC sheathed armoured cables including 8 SWG GI earth wire on surface/cable trays as required.
-
-
-
NS - 12: 3 Core - 10sq.mm (2.nos)
40
-
-
Providing, installation, testing & commissioning of dust and vermin proof motor control panel fabricated from 14 SWG MS sheet with stove enamelled paint and comprising of: Outdoor type.
-
-
-
63 amps incoming MCB (1 No.)
-
-
-
One no fully automatic Dol starter with push buttons and indicating lights.5.5 KWs
-
-
-
One panel type volt meter 96mm square with Rotary selection switch for reading voltage between phase and neutral or incoming feeder.
-
-
-
Three Neon Phase indicating lights on the incoming Main.
-
-
-
One Ampere meter 96mm square panel type of appropriate range.
-
-
-
Etched plastic identification plates for all switch gears.
-
-
-
Space for liquid level controller.
-
-
-
NS - 13: All internal wiring should be colour coded from incoming main to switchgear, starters, meters, indicating lights.