Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
₹ 6,10,000Document Cost
₹ 3,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_702462_1Tender No
CEAFU-26 of 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Construction and completion of left over works of covered accommodation for vehicle garage for type B vehicle 05 Nos including rolling shutter, framed structure complete all as specified, directed at site and as shown on drawings. For reference Ref Appendix 'C1'
1
1987777
-
... More
Construction and completion of left over works of building for DG set, heating plant room, RCC wall all around, Paved area, rolling shutter and toilet etc framed structure complete all as specified and directed by Engineer in Charge. For reference Ref Appendix 'D1'
1
5676408
-
... More
Construction and completion of buildings for Guard Room with toilet framed structure complete all as specified directed at site and as shown on drawings.
1
912094
-
... More
Construction and completion of building for sentry post/Guard post of PCC blocks construction complete all as specified and directed at site and as shown on drawings
1
51489
-
... More
Construction of septic tank for 25 users complete including inlet/outlet chambers in stone masonry, RCC slab, excavation in hard/dense soil, RR masonry in CM1:4 CI vent pipe, manhole cover slabs, complete all as specified and as shown on drawings
1
151954
-
... More
Construction of septic tank of capacity for 10 users complete including inlet/outlet chambers in stone masonry, RCC slab excavation in hard/dense oil, RR masonry in CM 1:4, CI vent pipe, manhole cover slabs, complete all as specified and all as shown on drawings.
1
86176
-
... More
Construction of soakage well, 2.40m dia and 3.00 m deep below inlet pipe including excavation in hard/dense soil, PCC 1:3:6 in foundation, stone masonry walls, RCC cover slab complete all as specified and all shown on drawings.
1
138428
-
... More
Steel gate 4m wide and 2m high complete with RCC columns roller tracks including form works and reinforcement complete all as specified, directed and all shown on drawings.
2
60683
-
... More
Total amount of Schedule 'A' PART-I (BUILDING WORK)
-
-
-
... More
Total amount of Schedule 'A' PART-II (LEFT OVER WORKS AND PRICES FOR PLUMBING WORKS)
1
56748
-
... More
Total amount of Schedule 'A' PART-III (LEFT OVER WORKS AND PRICES FOR INTERNAL WATER SUPPLY)
1
34438
-
... More
Total amount of Schedule 'A' PART-IV LEFT OVER WORKS FOR SEWAGE DISPOSAL
1
207331
-
... More
Total amount of Schedule 'A' PART-V (SECTION-I) LEFT OVER WORKS AND PRICES FOR INTERNAL ELECTRIFICATION
1
486329
-
... More
SCH 'A' PART-V( SECTION-II): LIST OF LEFT OVER WORKS INTERNAL ELECRIFICATION Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
-
-
-
... More
Fluorescent tube light fitting box type 2x36/40 watts precoated CRCA sheet steel housing complete with electronic ballast, spring loaded bipin holders, connector block all accessories prewired with suitable size cable alongwith decorative end caps conf to Cat part No BCIR 236 W2EB of make Bajaj or equivalent of make Philips/crompton including 4', 2x36 watt tube rod and connecting electrically using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 Sqmm 3 core all as required at site or directed.
106
-
-
... More
Fluorescent tube light fitting box type 1x36/40 watts precoated CRCA sheet steel housing complete with electronic ballast, spring loaded bipin holders, connector block all accessories prewired with suitable size cable with decorative end caps conf to Cat part No BCIR 136 WEB of make Bajaj or equivalent of make Philips/Crompton including 4', 1x36 watt tube rod and connecting electrically using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 Sqmm 3 core all as required at site or directed.
140
-
-
... More
Surface mounted CFL luminaire for mirror lighting conforming to Cat Part No TLN 11/W of Crompton Greaves or equivalent of Make Philips /Bajaj complete with lamp including connecting electrically to celling Rose using cord flexible 3 core PVC insulated overall sheathed with flexible copper conductor of size 0.50 sqmm complete all as required and directed.
5
-
-
... More
Hanging only Ceiling fan 1200mm swipe suitable to work on single phase AC 230 volts 50 Hz supply complete with regulator step type hum free suitable to control speed of fan 0 to 100% connecting electrically to celling rose or connector block using PVC insulated and overall sheathed 3 core cable of size 0.75 sqmm with flexible copper conductor all as required at site and directed. Note : Ceiling fan and regulator shall be issued under sch B free from fixing.
37
-
-
... More
Submain wiring with four single core PVC insulated flexible copper conductor cable of size 10 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 6 sqmm as earth lead in and incl concealed PVC conduit light grade and cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification complete all as required at site and directed by Engineer-in-charge. (Make of cable: L&T, Finolex, Grandlay).
60
-
-
... More
Submain wiring with two single core PVC insulated flexible copper conductor cable of size 6 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 4 sqmm as earth lead in and incl concealed PVC conduit light grade and cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification complete all as required at site and directed by Engineer-in-charge. (Make of cable: L&T, Finolex, Grandlay).
170
-
-
... More
Fixing only exhaust fan 300mm sweep, single phase 230 volts 50 Hz AC totally enclosed including cutting chases for fixing fan, connecting using 3 core cable of size 0.75 sqmm PVC insulated flexible copper conductor cable over all as sheathed all as required at site and directed by Engineer-in-charge. Note : Exhaust Fan and regulator shall be issued under sch B free from fixing.
11
-
-
... More
Heavy duty exhaust fan 5 star rated (as per BEE recommendation) 225 mm sweep, phase 230 volts 50 Hz AC totally enclosed heavy duty motor with die cast aluminium rotor mounted on two ball bearings complete louvers including cutting chases for fixing fan, connecting using 3 core cable of size 0.75 sqmm PVC insulated flexible copper conductor cable over all sheathed all as required at site and directed by Engineer-in-Charge. (Make : Khaitan/Bajaj/Crompton).
5
-
-
... More
Distribution board iron clad, double door with IP-43 IK 09 protection suitable for MCB TPN as in commer and MCB SP as outgoing 415 volts 3 phase 50 c/s 4 way , complete with appropriate size copper bus bar and neutral link conforming to cat part No 607715 of Legrand or equivalent of make C&S/Marlin Gerin, complete with one MCB TPN 415 Volts 30 Amps rating with rupturing capacity 10KA of same make of distribution board including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site and directed by Engr-in-charge.
2
-
-
... More
MCB single pole 240 volts 5 to 30 Amps, with rupturing capacity 10 KA. (Make Hager/Legrand/L&T/ Marlin Gerin(multi-9).
106
-
-
... More
MCB single pole and neutral 240 volts 5 to 30 Amps, with repturing capacity 10 KA. (Make Hager/Legrand/L&T/Marlin Gerin(multi-9))
15
-
-
... More
Street light fittings HPSV, single piece, cast aluminium with full glass cover integral luminaire and accessories IP 65 conf to cat pt NO BGEST 02 70 SV IP 65 FG of Bajaj or equivalent of make Philips/Crompton with lamp and connecting electrically using cable PVC bracket insulated 1.5 Sqmm from DB to street light including GI bracket made of GI tubing of suitable size, clamp nuts and bolts required for fixing all as required and directed by Engineer-in -charge.
16
-
-
... More
Earthing complete with galvanised steel earth plate electrode of size 600x600x6mm thick as earth electrode with top edge of the earth plate not less than 1.5 mtr below ground level using GI wire 4 mm dia as earth continuity conductor connected to earth plate by means of GI thimbles, nuts, bolts, washers all as directed including providing earth wire protection pipe GI light grade 15 mm dia from earth plate to main switch board/panel, watering pipe 20mm dia medium grade with wire mesh and funnel at top,earth pit and RCC pit cover in PCC 1:3:6 including adquate quantity of charcoal, dust and salt all as around the earth plate including earth work in any type of soil, removing surplus excavated material all as required as site and specified in EP No 3 of SSr Part -I 2009 complete all as specified and directed by Engineer-in-Charge.
17
-
-
... More
Total amount of SCH 'A' PART-V( SECTION-II): LIST OF LEFT OVER WORKS INTERNAL ELECRIFICATION
-
-
-
... More
Total amount of SCH 'A' PART-VI (SEC-I) : LEFT OVER WORKS AND PRICES FOR EXTERNAL ELECTRIFICATION
1
502201
-
... More
SCH 'A' PART-VI (SEC-II) : LEFT OVER WORKS FOR EXTERNAL ELECTRIFICATION Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
-
-
-
... More
Supply, Installation, commissioning & testing of diesel engine driven generating set of 80 KW/100 KVA output at NTP, 415 volts, 50c/s AC, 3 phase 4 wire at power factor of 0.8 lagging all as per IS-4272/2001, mounted on common base plate and directly coupled through flexible coupling to diesel engine with cushy foot mountings pad in and incl acoustic insulated enclouser/canopy with 75 db noise level at 01 metre distance from DG set, complete with self starting system including accessories, equipment control panel etc as detailed below. (a) Alternator (Brush less) shall be design for an out put of 100 KVA at full load for continuous rating at 0.80 PF AC 3 phase 4 wire 415 volts 50c/s, self exicited, self regulated, Screen protected drip proof type with two end shield ball/Roller bearing with damper winding in each pole faces as per IS :4722 or BS 2613-1970 all as specified and directed, Make Kirloskar Electric/ Crompton/Standford. (b) Diesel Engine : Diesel engine water cooled of BHP 127 HP and electric start suitable to drive above alternator independently, coupled directely through flexible coupling, multicylinder four stroke, cold starting, 1500 RPM industrial type as per BS 649 or IS : 1601 with A1 electronic governor suitable to regulate speed of DG set from No load to Full load complete with fuel tank of cap as per manufactrer recommendations, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and silencer mufflers etc for continuous operation and standard accessories, sump pre heaters etc all as specified and directed. Make Kirloskar/Crompton/Standford
3
-
-
... More
(c) Control Panel: The standard control panel consisting of control cubical fabricated sheet steel construction indooor type suitable for mounting accessories, multifuctional digital meter suitable for measuring energy, power factor, frequency, voltage (0-500) volts and current, including CT's of suitables ratio with inbuilt selector switch , indicator lamps LED type, Hours Meter/RPM indicator, low oil pressure indication, over speed indication and high water temperature indicator. (d) Electric starter equipment : The equipment will comprise the followings (i) Maint free battery duly initial charged and battery lead of adaquate cap make of battary Amron/ Luminous/SUKAM/MICO (ii) Starter Motor (iii) Starter gearing (iv) Start/Stop PUSH button (v) Inventor cum battery charger 500 VA capacity suitable to work on 230 volts 50 Hz AC supply system for charging of DG set batteries externally when DG set is in off position. Make : Microtek/Sukam.(vi) Alternator/Dynamo of suitable capacity to charge the batteries while DG Set is running complete with auto cut out all as per manufacture recommendations. Note: PCC foundation for DG Set all as per manufacturer's recommendations or required at site or directed by Engr-in-Charge. Accountic canopy of DG Set shall be of OEM or of make: Sudhir/Kirloskar Green/Bashkar.
-
-
-
... More
Supply, installation, commissioning and testing LT panel indoor cubical floor mounted type made out of 1.6 mm thick MS sheet duly powder coated complete with bus bar 300 amps rating made of copper strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415 volt 50 Hz power supply system suitable for and including the following :- (i) MCCB 160 Amps 4 pole 50 Hz 415 volts with rupturing capacity 36 KA (ICS = 100% ICU) : 01 Nos as incoming conf to cat part NO 025173 of Legrand or equivelant make L&T(D Sine)/Schneider(Compact NSX) (incoming). (ii) MCCB 100 Amps 3 pole 50 Hz 415 volts with rupturing capacity 36 KA (ICS = 100% ICU) : 01 Nos as outgoing conf to cat part No 625340 of Legrand or equivelant make L&T(D Sine)/Schneider/C&S, (Base OPs bldg). (iii) MCCB 63 Amps 3 pole 50 Hz 415 volts with rupturing capacity 25 KA (ICS = 100% ICU) : 01 Nos as outgoing conf to cat part No 625339 of Legrand or equivelant make: Schneider/C&S (for central air heating load).
1
-
-
... More
(iv) MCB TP 32 Amps C curve type 415 volts 2 Nos conf to cat part No 603288 of Legrand or equivelant make Hager/Marlin Gerin multi-9 (for internal lighting of heating plant room and DG set Room). (v) MCB DP 32 Amps C curve type 415 volts 1 Nos conf to cat part No 603271 of Legrand or equivelant make Hager/Marlin Gerin multi-9 (street lighting). (vi) Indicator set RYB 01 Set of 3 pices, LED type make AE/L&T. (vii) Digital volt meter of size (96x96)mm range 30 to 600 volts of AE make or equivelant of make L&T with inbuilt in selector switch 01 set. (viii) Digital Ammeter of size (96x96)mm range 0 to 200 Amps of AE make or equivelant of make L&T with inbuilt in selector switch complete with CTs of appropriate ratio 01 set. (ix) On load change over switch 415 volts 315 Amps 4 pole front handle operated with out enclosure suitable for panel mountings 2 Nos Make : Havells/Euroload/ C&S/ Socomak(HPL). All accessories perwired with suitable size copper conductor cable/strip and suitable foundation as per manufactrur's recommandation. Make of Panel : DVEPL/Tricolite/Simon fabricators/ Electric field.
-
-
-
... More
Supply and fixing Street light fitting 70Watt metal halide 230 V single piece die cast aluminum housing with step pot optics reflector and toughened clear glass cover for lamp and control gear compartment conf to cat part No BGWRL 70MH FFG WOB of Bajaj or equivelant make Crompton/Philips complete with lamp, and PVC insulated unsheathed flexible copper conductor cable of size 1.5 Sqmm from DB to street light all as required and directed.
6
-
-
... More
Mounting bracket for street light bend to shape as per requirement made of 40 mm bore medium grade GI tubing 1.2 Mtr long and clamp, nut bolts all as required at site or directed.
6
-
-
... More
Chemical earting pit complete with copper earth plate electrode 600x600x6mm buried directly in the ground vertically to depth not less than 3.3 Mtr below the ground level with the top edge of earth plate, depth not less than 2.7 Mtr below the ground level connected to copper earth strip of 25 mm x 3mm size by means of bolts, nuts and washers protected by GI tubing light grade 40 mm dia upto test point 20 mm dia watering pipe with funnel & wire mesh, PCC pit in PCC 1:2:4 using 20 mm stone aggregates chamber 40mm thick RCC cover slab (1:2:4) type B1 using 20mm graded stone aggregate complete all as specified and shown in electrical plate No 3 of SSR Part -I including earth work in any type of soil, removal of surplus soil and earth pit filled with chemical earth gel with hardnerer (hydroscopic in nature) back fill 40 Kg minimum all around the earth plate upto 15 cm and vegtable soil all as required specified and directed by Engr-in-Charge. (Note : upto 7.5 mtr length of pipe of 40mm dia and copper strip shall be deemed to be included in unit rate quoted by tenderer). During earh resistence test earting resistence should not be more than 2 Ohms, in case earthing resistance is more than 2 Ohm, re-earthing will have to done by the contractor without extra cost to department. Make : Pragati Electro com(P) Ltd/JMV/ENNOV/ATHARVA.
14
-
-
... More
Laying only XLPE insulated screened PVC bedded, galvanized steel strip of wire armoured, electric power cables laid in trenches 1100 volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core (Note Cable shall be issued under sch B free from fixing).
210
-
-
... More
Laying only XLPE insulated screened PVC bedded, galvanized steel strip of wire armoured, electric power cables laid in trenches 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 2 core (Note Cable shall be issued under sch B free from fixing).
450
-
-
... More
UPS for 30 minute back up 3 phase input 300 to 450 volts and output 415 + 1% Capacity 15 KVA. Make : Microtek/Luminous/Sukam.
1
-
-
... More
Total amount of SCH 'A' PART-VI (SEC-II) : LEFT OVER WORKS FOR EXTERNAL ELECTRIFICATION
-
-
-
... More
Total amount of SCH 'A' PART-VII (Section-I): LEFT OVER WORKS AND PRICES FOR EXTERNAL WATER SUPPLY
1
361725
-
... More
SCH 'A' PART-VII (Section-II): LIST OF LEFT OVER WORKS FOR EXTERNAL WATER SUPPLY Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
-
-
-
... More
Construction of valve pit of random rubble stone masonry of size 0.9mtrx0.9mtrx1.5mtr (Internal dimensions) in CM 1:6 including 10mm thick plastering internally and pointed flush externally to stone wall with same material as work proceeds complete with 3 mm thick MS sheet top cover with angle iron frame size 40x40x6 mm, hinges and locking arrangement including grouting in PCC 1:2:4 type B-O (using 12.5 mm graded aggregate) including excavation and earth work in any type of soil, returning, filling, disposal of surplus soil to a distance of 50 metere and painting MS sheet covered iron frame with synthetic enamel paint over a coat of red-oxide complete all as specified and shown on drawings.
4
-
-
... More
Kaiflex insulation tubing 19 mm thick of size 48 mm internal dia including jointing material such as tape aluminium for self adhesive solvent etc including aluminium foil cladding complete all as specified.
400
-
-
... More
Kaiflex insulation tubing 19 mm thick of size 28 mm internal dia including jointing material such as tape aluminium for self adhesive solvent etc including aluminium foil cladding complete all as specified.
100
-
-
... More
Kaiflex insulation tubing 19 mm thick of size 22 mm internal dia including jointing material such as tape aluminium for self adhesive solvent etc including aluminium foil cladding complete all as specified.
50
-
-
... More
Cast iron air release valve complete with nuts, bolts and gasket of size 40 mm dia complete all as specified.
1
-
-
... More
Drain valve of size 40 mm to drain remaining water from pipe after supplying water to avoid any freezing of pipe line complete all as directed at Schedules.
1
-
-
... More
Total amount of SCH 'A' PART-VII (Section-II): LIST OF LEFT OVER WORKS FOR EXTERNAL WATER SUPPLY
-
-
-
... More
Total amount of Schedule 'A' PART-VIII LEFT OVER WORKS AND PRICES FOR ROAD
1
470553
-
... More
Total amount of Schedule 'A' PART-IX LIST OF LEFT OVER WORKS AND PRICES FOR SECURITY FENCING AND STEEL GATE
1
579805
-
... More
Total amount of SCH 'A' PART - X LIST OF LEFT OVER WORKS AND PRICES FOR SITE CLEARANCE
1
8739000
-
... More
SCH 'A' PART-XI LIST OF WORKS AND PRICES FOR CENTRAL HEATING PLANT) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
-
-
-
... More
Supply, fixing, commissioning and testing of vertically mounted Thermic fluid Heater (TFH) capable of delivering a heat output 400000 K Cal/Hr using HSD oil complete in all respect, including following item of work.
(a) Heater unit : Heat exchanger, consisting of closely wound, helical, concentric coils, arranged to give adequate no passes on flue gas side and made out of ERW tubes, conforming to IS 3059 Part -I suitable for high temperature all as per manufracturer design and of required head and capacity.
(b) Pressure jet burner : Suitable for light oil firing with stepless modulation mechanism all as per manufracturer design and of required head and capacity.
(c) Combustion: Combustion air fan with drive motor assembly all as per manufracturer design and of required head and capacity. (d) Control Panel : Dust protected pre wired unit mounted air cooled control panel housing a burner management system switch gear consisting of contractors, overload relays, fuses and MCB etc. all as per manufracturer design and of required capacity. (e) Circulating pump : Centrifugal thermic fluids circulating pumps suitable for high temperature operation, coupled with electric motor drive mounted on common base frame all as per manufracturer design and of required head and capacity.
2
-
-
... More
(f) DE Tank: Derator cum expansion tank consisting of expansion, derator and buffer vessels, gauge glass assembly and level switches. Nozal for inlet and outlet on derator for drain on buffer vessel all as per manufacturer design and of required head and capacity.
(f) Fuel Pump: Fuel pump with drive motor assembly all as per manufacturer design and of required head and capacity.
(g) Piping Work: Piping work required inside the plant room, including valves, pressure indicating instruments, insulation material, protective works etc all as per manufacturer design and of required head and capacity.
(h) Oil Line: Oil line with duplex filters on fuel line at the inlet of fuel pump, Y strainer on fuel pump outlet and bypass line, non return valve on modulation and circulation line, fueloil regulation valves for burner mudulation, burner solenoid valve, fuel oil pressure guage at burner inlet, fuel pressure gauge on by pass line etc all as per manufacturer design and of required head and capacity.
-
-
-
... More
(j) Thermic Fluid Line : Thermic Fluid line inside the plant room with insulating material, spring loaded safety relief valves, temp controller for stepless burner modulation on thermic fluid outlet temp of the heater, switch for burner on off cycle, burner interlocking with temp of thermic fluid at differential pressure switch between inlet/outlet of fluid outlet all as all as per manufacturer design and of required head and capacity.
(l) Burner programmer : Burner programmmer with matching flame sensor all as per manufarcturer design. (m) Hooter : Hooter mounted on control panel for audiable safety alarm all as per manufarcturer design. (n) Temp Indicator Cum Switch : Temp Indicator cum switch for high stack temp alarm for flue gasses all as per manufarcturer's design. (p) Chimney : 8 Mtr high Chimney above building roof made out of 3 mm thick mild sheet including flue gas duct all as per manufacturer. Note : Thermic fluid and thermic fluid line including lagging from plant room to work place shall be provided measured and paid as a separate item of work.
-
-
-
... More
Supply and installation of thermic fluid storage of capacity 5000 ltr made out of 5mm thick MS sheet complete all as directed at site.
1
-
-
... More
Supply and installation of Diesel fuel storage of capacity 2000 ltr made out of 5mm thick MS sheet complete all as directed at site.
1
-
-
... More
AIR HANDLING UNIT :- Air handling unit of sectionalised construction, factory made casing, double skin type complete of nominal capacity 16000 CFM 02 Nos shall be comprising of followings:-
(aa) Heating coils of copper tubes with aluminium fins, 4 row deep or as per heat exchanger for its best effiency. Make : Wave/ZECO/HI-Tech/Universal. (bb) Filter suitable for dust filteration to particle of size 15 microns facing to AHU. Filter shall be such that will not burn freely or emit large volume of smoke or other objectionable product of combution when attacked by flame. Make : Thermodyne/Purolator.
(cc) Centrifugal fan for weather maker complete with electric driven squirrel cage induction motor of capacity not less than 7.5 KW suitable for operation on 415 volts 3 Phase AC supply, Fan to generate sufficient pressure and velocity so that every room gets adequate quantity of conditioned air at appropriate velocity, Make : Crompton/Greaves/ Seimens/ABB.
(dd) Humidification kit complete with pump and motor of suitable capacity with GI headers appropriate No of brass nozzles complete with humidistat to switch on and off of pumping set at pre set levels. Make of Humidistat : Honey well/Rapid Cool/Emeraid.
1
-
-
... More
(ee) Ducting and insulation: Supply, fabrication, installation of air duct of made of PGI sheet of thickness as per indian standard(IS-655-1963) including 3mm rubber gasket and nut and bolt for jointing the duct with necessary fresh air damper, made of MS sheet duly powder coated with bird screen, supply air grills/difuser and return air grills/difuser made of aluminium, including main air chamber complete insulated with fiber glass wool sheet 50mm thick density not less then 144 Kg/cum and covered with chicken wire mesh and 10mm thick cement sand plaster decoratively out side covered space and with almin foil 0.1mm thick inside covered space including fire damper made of 20 guage PGI sheet in main supply air duct and return air duct as per manufacture. Insulation and lining and coating to be used in conjuction with ducts, shall be non combustible type material. Ducting shall be provided with arrangement of fire damper/stopers actuating at pre determined temperature by means of fusible link or an electronic devices operated by either smoke detection system or failure of power supply, there by emmiting audio visual alarm. Dampers shall be installed in the inlet duct at point of orginating from AHU and at all points of entry and exit where the return duct pass from one room or comparment to other room or comparment.
-
-
-
... More
Supply and fixing MS tubing with all fittings laid in trenches/wall/ceiling of size 80mm dia complete all as directed at site. Make : Tata/Jindal/Prakash Surya
50
-
-
... More
Supply and fixing MS tubing with all fittings laid in trenches/wall/ceiling of size 50mm bore. Make : Tata/Jindal/Prakash Surya
100
-
-
... More
Supply and fixing Kaiflex insulation tubing 19 mm thick of size 89 mm internal dia including jointing material such as tape aluminium for self adhesive solvent etc including aluminium foil cladding.
50
-
-
... More
All as per item No 14.07 above but of 60mm bore.
100
-
-
... More
Sluice valve flanged of class 1.6 PN with forged brass stem with nuts, bolts, gaskets of size 80mm dia all as specified and directed. Make BIR/Kiroskar/Beacon/ /Venus.
2
-
-
... More
Gun metal gate valve with iron head screw both end for MS pipe of size 50mm dia Make BIR/Kirloskar/Venus/ Beacon.
4
-
-
... More
Earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm buried directly in the ground vertically to depth not less than 3 Mtr below the ground level with the top edge of earth plate, depth not less than 2.25 Mtr below the ground level connected to GI earth strip of 32 mm x 6mm size by means of bolts, nuts and washers protected by GI tubing light grade 40 mm dia upto test point 20 mm dia watering pipe with funnel & wire mesh, PCC pit in PCC 1:2:4 using 20 mm stone aggregates chamber 40mm thick RCC cover slab (1:2:4) type B-1 using 20mm graded stone aggregates complete all as specified and shown in electrical plate No -3 of SSR Part -I including earth work in any type of soil, removal of surplus soil and providing charcoal dust and salt layers all around the earth plate upto 15cm all as required specified and directed by Engr-in-charge. Note: (upto 7.5mtr length of pipe of 40mm dia and GI strip shall be demed to be included in unit rate quoted by tenderer).
8
-
-
... More
Supply only in barrels and filling of thermic fluid of capacity above 200˚C Temp as vapourisation temprature complete all as directed.
3000
-
-
... More
Construction of valve pit of random rubble stone masonry of size 0.9x0.9x1.05 mtr (Internal dimensions) in CM 1:6 including 10mm thick plastering internally and pointed flush externally to stone wall with same material as work proceeds complete with 3 mm thick MS sheet top cover with angle iron frame size 40x40x6 mm, hinges and locking arrangement including grouting PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) including excavation and earth work in any type of soil, returning, filling in, disposal of surplus soil to a distance of 50 meters and painting MS top sheet angle iron frame with synthetic enamelled paint or a coat of red oxide complete.
2
-
-
... More
Excavation in trenches in any type of soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out for foundation or laying of cables/tubing GI.
41
-
-
... More
Removing excavated material (soil) not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point.
2
-
-
... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick.
39
-
-
... More
Total amount of SCH 'A' PART-XI LIST OF WORKS AND PRICES FOR CENTRAL HEATING PLANT)
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%