Ladakh Autonomous Hill Development Council Tender
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
₹ 1,84,015Document Cost
₹ 2,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_LAHD_2414_1Bid Award Id
ViewTender No
E-tender 31 of TDA Leh for the year 2020-21Tender Authority
Ladakh Autonomous Hill Development Council ViewPurchaser Address
-Website
http://https://leh.nic.in/lahdcleh/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Construction of Directorate Office I C Ladakh at office complex of District Industries Centre, Leh
Construction of Directorate Office I C Ladakh at office complex of District Industries Centre, Leh
BOQ Items
CONCRETE WORK: Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
10.69
-
-
R.C.C WORK:- Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
124.92
-
-
REINFORCEMENT:- Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
18739.02
-
-
Centering and shuttering including strutting, propping etc. and removal of form for: a) Foundations, footings, bases of columns etc. for mass concrete.
50.19
-
-
Columns, pillars, piers, abutments, posts and struts.
188.47
-
-
Lintel, beams, plinth beam, girders, bressumes and cantilever.
239.4
-
-
Stairs, dogleg going
22.17
-
-
Suspended floors, Roofs, Landings, Balconies and Access Platforms.
334.6
-
-
BRICK BLOCK: Providing & fixing upto floor five level precast cement concrete solid blocks includinghoisting and setting in position in cement mortar 1:3 (1cement:3 coarse sand), cost of required centring, shuttering and curing complete
106.96
-
-
WOODEN FRAMES :- Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately):Second class kail wood
2.85
-
-
GLASS PANELLING:- Providing and fixing panelling or panelling and glazing in panelled or panelled
and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.4 mm thick glass pane (weighing not less than 10 kg/sqm
74.35
-
-
DOOR SHUTTER:- Providing and fixing ISI marked flush door shutters 25 mm thick pre-laminated flush door shutter bothside decorative.
7.67
-
-
ALLUMINIUM WINDOW FRAMES
19.24
-
-
GLASS PANELLING FOR ALUMINIUM FRAMES:- Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin- charge. (Cost of aluminum snap beading shall be paid in basic item.)With float glass panes of 8 mm thickness (weight not less than
20.0 kg / sqm)
19.24
-
-
Providing and fixing ladakhi type ornaments shingtsak and kaju over doors, and lintels.
25
-
-
CEMENT PLASTER IN FINE SAND 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand)
581.8
-
-
EXTERNAL WALL PLASTER ROUGH CAST PLASTER:- Rough cast plaster upto 10 m height above ground level with a mixture of sand and gravel or crushed stone from 6 mm to 10 mm nominal size, dashed over and including the fresh plaster in two layers, under layer 12 mm cement plaster 1:4 (1 cement: 4 coarse sand) and top layer 10 mm cement plaster 1:3 (1 cement: 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement. Ordinary cement finish using ordinary cement1:4 (1 cement 4 fine sand)
71.38
-
-
6 MM CEMENT CEILING PLASTER:- 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) sqm
301.71
-
-
EXTERIOR FINISHING:- Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm)
71.37
-
-
Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1 mm thick
883.54
-
-
Distempering with 1st quality acrylic istemper, having VOC (Volatile Organic Compound) content less than 50 grams/ liter, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
883.54
-
-
PRIMING COAT ON WOOD WORK:- Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ liter
85.23
-
-
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. (3" tube ms bar @6.8kg/m)
103.63
-
-
Railing vertical bar 10 mm dia M/S Bar
59.52
-
-
Providing and fixing 150 mm bright finished floor brass door stopper withrubber cushion, necessary brass screws etc. to suit shutter thickness complete
14
-
-
Providing and fixing 85x42 mm chromium plated brass pull bolt lock with necessary C.P. brass screws, nuts, bolts and washers etc. complete
14
-
-
Providing and fixing aluminum tubular handle bar 32mm outer dia, 3.0mm thick & 2100mm long with SS screw etc. complete as per direction of Engineer-in-charge.Anodized (AC 15) aluminum tubular handle bar
14
-
-
FLOORING:- Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 25mm thick with 12.5 mm nominal size stone aggregate.
126.63
-
-
MARBLE STONE FLOORING:- Flooring with marble stone of specified thickness as per sample of marble approved by Engineer-in-charge, over 20 mm average) thick base of cement mortar 1:4 (1 cement:4 coarse sand) laid and jointed with grey cement slurry including rubbing, polishing and curing complete with:
76.2
-
-
KOTA STONE FLOORING:- Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average) thick cement mortar 1:3 (1 cement:3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing, polishing and curing complete.
36.93
-
-
WOODEN FLOORING.:- Wooden planking, tongued and grooved in flooring including fixing with iron screws complete:
113.8
-
-
POP FALSE CEILING.:- Providing and fixing false ceiling with 12 mm thick plain/ semi perforated or with design ceiling tiles of BWP type phenol formaldehyde synthetic resin bonded pressed particle board conforming to IS:3087, finished with a coat of aluminum primer on both sides & edges, including two coats of synthetic enamel paint of approved quality on exposed face, fixed to a grid made out of anodized aluminum (with 15 micron anodic coating) Tsections 35 x15x1.5 mm size main runners, cross runners 23.5x19x1.5 mm fixed to main runners placed 600 mm centre to centre both ways so as to form a grid of 600 mm square. The frame work shall be uspended from ceiling by level adjusting hangers of 6 mm dia M.S rod fixed to roof slab bymeans of ceiling cleats and dash fastener. The suspenders shall be placed 600 x 1200 mm centre to centre including fixing to the frame with C.P brass screws and applying a priming coat of zinc chromate yellow primer (aluminum frame work shall be paid separately).
97.45
-
-
Providing and fixing 1st quality ceramic glazed floor tiles conforming toIS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
2.21
-
-
CERAMIC TILES on Kitchen Wall:- Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622(thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
4.41
-
-
Kitchen Wall :- Stainless steel kitchen sink - with drain board 510 x 1040 mm bowl depth 250 mm
1
-
-
WALL CLADING:- Stone tile work for wall lining upto 10m height with special adhesive like araldite or equivalent over 12mm thick bed of cement mortar 1: 3 (1 cement: 3 coarse sand) including pointing in white cement with an admixture of pigment to match the stone shade.Granite stone of any colour and shade
25.09
-
-
FLOORING TILES:- Chequerred precast cement concrete tiles 22mm thick in footpath and courtyard, jointed with neat cement slurry mixed with pigment to match
the shade of the tiles, including rubbing, cleaning and curing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand)Dark shade using ordinary
74.35
-
-
SANITARY FITTING:- Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:All Kind of soil
59.43
-
-
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
1.1
-
-
Random Rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with:Cement mortar 1:6 (1 Cement : 6 coarse sand
13.6
-
-
SOLID BRICK BLOCK:- Providing & fixing upto floor five level precast cement concrete solid blocks includinghoisting and setting in position in cement mortar 1:3 (1cement:3 coarse sand), cost ofrequired centring, shuttering and curing complete1:3:6 (1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20 mm nominal size)
14.9
-
-
RCC WORK:- Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
3.4
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo-Mechanically Treated bars of grade Fe-500D or more.
407.52
-
-
FOAM WORK:- Suspended floors, Roofs, Landings, Balconies and Access Platforms.
22.3
-
-
12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand)
32.7
-
-
FLOOR TILES:- Providing and fixing 1st quality ceramic glazed floor tiles conforming toIS : 15622 (thickness to be specified by the manufacturer ) of approved
make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
23
-
-
CERAMIC GLAZED WALL TILES:- Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622(thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
82.12
-
-
SANITARY INSTALLATIONS :- Providing and fixing white vitreous china European type W.C. pan with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :Long pattern W.C Pan of size 580x440 mm
4
-
-
White Vetrious China Waterless Urinal of size 600x330x315 mm
2
-
-
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size
75x50 cm deep, fixed in urinal partitions by cutting a chase of appropriate width withchase cutter and embedding the stone in the chase with epoxy grout or with cement
concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-Charge and finished smooth.White Agaria Marble Stone 16MM
2
-
-
Vitreous china pedestal for wash basin
5
-
-
Mirror of superior make glass 60x45 cm
5
-
-
uPVC pipes (working pressure 4 kg / cm2 ) Single socketed pipe metre.75mm
30
-
-
110mm
40
-
-
uPVC single equal Tee (without door) 75x75x75 mm
4
-
-
110x110x110 mm
4
-
-
7232 Resin bonded glass wool @ 24 kg / cum., 50 mm thick sqm 143.00bend UPVC plain shoe
72.5
-
-
Band UPVC plain Shoe. 75 mm
3
-
-
110 mm
3
-
-
Poly propylene- Random - Co - Polymer (PPR) pipes PN-16 (SDR 7.4) 16mm
30
-
-
20mm
30
-
-
25mm
40
-
-
Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931
6
-
-
Providing and fixing 15 mm nominal bore C.P. stop cock (concealed) of standard design and of approved make conforming to IS : 8931
4
-
-
Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931
3
-
-
Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg.
6
-
-
C.P. brass Toilet paper holder of standard size
4
-
-
Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms.
5
-
-
Towel rail C.P. brass 600 x20 mm together with a pair of C.P. brass brackets to fit the size of towel rail
5
-
-
Rectangular shape 600x450 mm precast R.C.C. manhole cover.
5
-
-
ELECTRIC WORK:- Wiring for light point/fan/call bell point/6 amp socket with 1.5 sq mm. For PVC insulated strand copper cable in existing surface /recessed PVC conduict including 6ap 240 volt single pole switch with moulded cover plate in zinc chromate passivated MS box, and including cost of loop earthing wit 1.5sq mm FR PVC insulatd stranded copper conductor cable, complete as required.
40
-
-
Wiring for 16 map socket otlet with 4 sq mm FR PVC insulated stranded copper conductor cable in surface/recessed steel conduit including wooden box, sheet and 1.5 sq mm FR PVC insulated copper conductor wire as earth wire.
40
-
-
Supply and fixing of a combined 5 pin 240 volt 6 amp socket outlet with safety shutters and 6 amp 240 volt single pole mounted switch with moulded switch with moulded cover plate in recessed zinc chromate passivated MS box complete as required.
40
-
-
Supply and fixing of a combied 5 pin 240 volt 16 amp 240 volt single pole grid plate mounted switch with moulded cover plate in recessed cover plate in recessed zinc chromate passivated MS box complete as required.
30
-
-
Supply and fixing of PVC conduit along accessories in surface walls and making good the same in case of recessed conduit as required. 25 mm dia 2 mm thick
80
-
-
Supplying and drawing circuit wiring for light point and 6/16/20 amp single phase socket outlet with 4.0 sq.mm pvc insulated copper conductor single core standard cable in the existing surface/recessed conduit/ raceway as required 25 mm dia 2mm thick
3
-
-
wiring of sub main wiring with following size of PVC insulated copper conductor single core cable in existing surface/recessed PVC conduct/ casting as required 10 sq.mm.
80
-
-
Wiring for telephone outlets with 2 pair of 0.5 sq mm PVC insulated copper conductor unarmoured telephone cable in the existing surface/casing and required.
5
-
-
Supply, installation, testing and commissioning of the following light fixtures including all accessories like electronic ballasts, bulbs, lamp etc complete as required as below: (A) 1x13 watt surface mounted LED fixtures as per Decon Cat no: 03TY including as required.
38
-
-
(B) 1x18 watt surface mounted mirror LED fixture as per Ankur Cat no XWL 010/0013 including 18 watt lamp as required.
4
-
-
(C) 1x60 watts GLS wall bracket fixture as per Philips Cat no: FXC101 including 60 watt GLS lamp as required.
38
-
-
Supply, installations, testing and commissioning of 300mm sweep heavy duty exhaust fan, 1400 RPM including all accessories suitable for single phase 240 volts 50 HZ AC supply complete as required.
3
-
-
Providing and fixing of 63 amp D pole changeover switch iron cold switch fuse unit inoculating drilling pole on the board tumbling connection earth the body etc. as required.
1
-
-
Wiring for Submains with 660 volt grade FR PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required and as below:- (A) 2x10 sq mm + 1x10 sq mm for loop earthing.
1
-
-
Supply and fixing of 240 volt miniature circuit breaker of following poles in the existing MCB DB complete with connection testing and commissioning etc as required. A) Single pole 6/10/16/20/amp
12
-
-
b) Double pole 40 amp
1
-
-
Supply and fixing of following ways, single pole and neutral sheet, MCB distribution board 240 volt on surface/recess, complete with tinned busber, neutral link, earth bar, detachable gland plate, double door, inter connection, including painting etc as required:- (A) 16 way sigma cat no. 12d 10
1
-
-
Supply, installations, testing and commissioning of electric pannel complete job as per requirement/ approved design specifications at site
1
-
-
Providing main electical connection upto electrical pannel form main transmission line. 75sqmm
30
-
-
Provding main electrical connection upto electrical pannel form generator.95 sqmm
30
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements