Indian Institute Of Technology Tender
Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.
Costs
EMD
₹ 1,00,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_IITK_834522_1Tender No
IITK/SEE/SCU/SOLAR/2024/01Tender Authority
Indian Institute Of Technology ViewPurchaser Address
-Website
http://https://www.iitk.ac.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
ARRAY JUNCTION BOXES (DCDB)
a) The junction box shall be dust free, vermin, and waterproof for outdoor application IP 65/66/67 and made of Thermoplastic / Polycarbonate material. b) The terminal will be connected to copper bus-bar arrangement of proper size to be provided with terminal blocks should be housed in the junction box with suitable termination threads Conforming to IP65/66/67 standard. The junction boxes shall have suitable cable entry points fitted with cable glands of appropriate sizes for both incoming and outgoing cables. c) Suitable markings shall be provided on the bus-bars for easy identification and cable ferrules will be fitted at the cable termination points for identification.
d) Each array junction Box will have suitable Reverse Blocking Diodes(2 Nos. Each) of maximum DC blocking voltage of minimum 600 V with suitable arrangement for its connecting.
Including Installations
Other aspects are as per tender - 100KW (Nos as per tender)
1
-
-
AC DISTRIBUTION BOARD (ACDB) a) The AC power output of the inverter shall be fed to the ACDB (metering panel & isolation panel) which also houses energy meter. The 4 UV AC output of the isolation panel shall be fed to the grid. AC energy is then synchronized with the grid and power is consumed by the grid.
b) ACDBs must be floor-mounted with a civil/constructed base and have measuring instruments for all inputs and outputs, such as voltmeters, ammeters, frequency meters, and energy meters, to accurately measure deliverable units, kWh, and selector switches according to specifications.
Including Installations
Other aspects are as per tender - 160KW (Nos as per tender)
1
-
-
WIRING All instruments and panel wiring shall be of heat resisting and extinguishing type in compliance with IS. Plastic or porcelain cleats of the limited compression type shall be used for holding wiring runs. All wires shall be suitable for bending to meet the terminal studs at right angles. Metal cases of all apparatus mounted on panels shall be separately earthed.
Including Installations
Other aspects (As per Tender specifications)
1
-
-
EARTHING
a) Earthing should be in accordance with the total power capacity of the plant i.e. 100Kw.
b) Each array structure of the SPV shall be earthed properly. The array structure are to be connected to earth pits as per Industrial standard. Junction boxes shall be connected to the main Earthing conductor/ electrode.
c) Earthing system installation shall be in strict accordance with the Indian Electricity Act 2003 upto date.
d) Necessary Test Point provision shall be made for bolted isolating joints of each Earthing pit for periodic checking of earth resistance.
e) Earth resistance of the earth pits shall be tested in presence of the representative of Principal Investigator or Nominee.
Other aspects are as per tender
1
-
-
LIGHTNING & OVER-VOLTAGE PROTECTION
a) L.A. should be in accordance with the total power capacity of the plant/area i.e. 100Kw.
b) The PV Power Plant should be provided with Lightning Arrester and over-voltage protection connected to proper earth system. The main aim of overvoltage protection is to reduce the over voltage to a tolerable level before it reaches the PV or other sub-system components. The source of overvoltage can be lightning or other atmospheric disturbance.
c) The lightning system / Conductors shall be made as per applicable Indian industrial standard.
Including Installations
Other aspects are as per tender
1
-
-
CABLE ACCESSORIES
a) All the wires/cables (whatever if) should be of Copper, 4core XLPE, unless mentioned specifically.
b) Only terminal cable Joints shall be accepted. No cable Joints to Join two cable ends shall be accepted.
c) Cable terminations shall be made with suitable cable lugs & sockets etc., crimped properly and passed through brass compression type cable glands at the entry and exit point of the cubicles. The panels bottoms should be properly sealed to prevent entry of snakes/lizard etc. inside the panel.
d) The terminal end of cables and wires are to be fitted with good quality numbered ferrules of proper sizes so that the cables can be identified easily.
Including Installations
Other aspects are as per tender
1
-
-
POWER CABLING and others
a) The power cables shall be XLPE insulated, PVC outer sheathed aluminum conductor, and armored cables rated for 1100 V grade. The power cables shall be of 4 cores for size roundoff 35 sq. mm for each 3-phase 25kW AC load. Where high-voltage equipment is to be fed, the cables shall be rated for continuous operation at the voltages to suit the same.
Including Installations
Other aspects are as per tender
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%