Indian Institute Of Technology Tender

Bidassist is designed as a single destination for all government tenders from across the world in one place. If you require any information or detail about any e-tender the Ladakh government has posted, Bidassist helps a registered bidder to get the same.As BidAssist is a very user-friendly website it will help you find the specific Ladakh etender you're looking for. Read further to learn how to search and bid for etender Ladakh.

Indian Institute Of Technology - IIT Tender

Works
Energy, Oil and Gas
Solar Installation and Products
Electrical and Electronics
Eprocure
Opening Date11 Nov 2024
Closing Date9 Dec 2024
Tender Amount₹ 48,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
ARRAY JUNCTION BOXES (DCDB) a) The junction box shall be dust free, vermin, and waterproof for outdoor application IP 65/66/67 and made of Thermoplastic / Polycarbonate material. b) The terminal will be connected to copper bus-bar arrangement of proper size to be provided with terminal blocks should be housed in the junction box with suitable termination threads Conforming to IP65/66/67 standard. The junction boxes shall have suitable cable entry points fitted with cable glands of appropriate sizes for both incoming and outgoing cables. c) Suitable markings shall be provided on the bus-bars for easy identification and cable ferrules will be fitted at the cable termination points for identification. d) Each array junction Box will have suitable Reverse Blocking Diodes(2 Nos. Each) of maximum DC blocking voltage of minimum 600 V with suitable arrangement for its connecting. Including Installations Other aspects are as per tender - 100KW (Nos as per tender)

1

-

-

... More
AC DISTRIBUTION BOARD (ACDB) a) The AC power output of the inverter shall be fed to the ACDB (metering panel & isolation panel) which also houses energy meter. The 4 UV AC output of the isolation panel shall be fed to the grid. AC energy is then synchronized with the grid and power is consumed by the grid. b) ACDBs must be floor-mounted with a civil/constructed base and have measuring instruments for all inputs and outputs, such as voltmeters, ammeters, frequency meters, and energy meters, to accurately measure deliverable units, kWh, and selector switches according to specifications. Including Installations Other aspects are as per tender - 160KW (Nos as per tender)

1

-

-

... More
WIRING All instruments and panel wiring shall be of heat resisting and extinguishing type in compliance with IS. Plastic or porcelain cleats of the limited compression type shall be used for holding wiring runs. All wires shall be suitable for bending to meet the terminal studs at right angles. Metal cases of all apparatus mounted on panels shall be separately earthed. Including Installations Other aspects (As per Tender specifications)

1

-

-

... More
EARTHING a) Earthing should be in accordance with the total power capacity of the plant i.e. 100Kw. b) Each array structure of the SPV shall be earthed properly. The array structure are to be connected to earth pits as per Industrial standard. Junction boxes shall be connected to the main Earthing conductor/ electrode. c) Earthing system installation shall be in strict accordance with the Indian Electricity Act 2003 upto date. d) Necessary Test Point provision shall be made for bolted isolating joints of each Earthing pit for periodic checking of earth resistance. e) Earth resistance of the earth pits shall be tested in presence of the representative of Principal Investigator or Nominee. Other aspects are as per tender

1

-

-

... More
LIGHTNING & OVER-VOLTAGE PROTECTION a) L.A. should be in accordance with the total power capacity of the plant/area i.e. 100Kw. b) The PV Power Plant should be provided with Lightning Arrester and over-voltage protection connected to proper earth system. The main aim of overvoltage protection is to reduce the over voltage to a tolerable level before it reaches the PV or other sub-system components. The source of overvoltage can be lightning or other atmospheric disturbance. c) The lightning system / Conductors shall be made as per applicable Indian industrial standard. Including Installations Other aspects are as per tender

1

-

-

... More
CABLE ACCESSORIES a) All the wires/cables (whatever if) should be of Copper, 4core XLPE, unless mentioned specifically. b) Only terminal cable Joints shall be accepted. No cable Joints to Join two cable ends shall be accepted. c) Cable terminations shall be made with suitable cable lugs & sockets etc., crimped properly and passed through brass compression type cable glands at the entry and exit point of the cubicles. The panels bottoms should be properly sealed to prevent entry of snakes/lizard etc. inside the panel. d) The terminal end of cables and wires are to be fitted with good quality numbered ferrules of proper sizes so that the cables can be identified easily. Including Installations Other aspects are as per tender

1

-

-

... More
POWER CABLING and others a) The power cables shall be XLPE insulated, PVC outer sheathed aluminum conductor, and armored cables rated for 1100 V grade. The power cables shall be of 4 cores for size roundoff 35 sq. mm for each 3-phase 25kW AC load. Where high-voltage equipment is to be fed, the cables shall be rated for continuous operation at the voltages to suit the same. Including Installations Other aspects are as per tender

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.