WAPCOS Limited Tender

... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

WAPCOS Limited - WAPCOS Tender

Works
Eprocure
Opening Date27 Nov 2021
Closing Date24 Jan 2022
Tender Amount₹ 31,96,12,248 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
od303403/2019_2020 : Finishing textured walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade

60631.81

-

-

... More
13.88 : Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete

196194.25

-

-

... More
13.83.2 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats

196194.25

-

-

... More
od25433/2020_2021 : "Applying one coat of water thinnable cement primer of approved brand and manufacture on textured wall surface : Water thinnable cement primer"<br>

60631.81

-

-

... More
od242735/2020_2021 : Repairs to aggregate plaster of external walls exactly matching with the existing finishing of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead with CM 1:4 (1 CEMENT&4 COURSE SAND)and with suitable aggregate

600

-

-

... More
Vertical Pipe Works

-

-

-

... More
od14609/2021_2022 : Dismantling PVC pipes manually / by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer- in- Charges:<br>15 mm to 40 mm nominal bore

3596

-

-

... More
od14626/2021_2022 : Dismantling PVC pipes manually / by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer- in- Charges<br>Above 40 mm nominal bore

2000

-

-

... More
50.18.9.12.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 20 mm dia 10Kgf/cm2 External work- Exposed on wall

800

-

-

... More
50.18.9.13.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10 Kgf/cm2- External work - Exposed on wall

400

-

-

... More
50.18.9.14.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - External work - Exposed on wall

400

-

-

... More
50.18.9.15.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 6 Kgf/cm2 - External work - Exposed on wall

1996

-

-

... More
50.18.9.16.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6Kgf/cm2 - External work - Exposed on wall

400

-

-

... More
50.18.9.17.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 4 Kgf/cm2- External work - exposed on wall

205

-

-

... More
50.18.9.18.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/Clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kfg/cm2 - External work - Exposed on wall

800

-

-

... More
50.18.9.19.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall

800

-

-

... More
15.2.2 : Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix)

15.34

-

-

... More
4.3.2 : Centering and shuttering including strutting, propping etc. and removal of form work for:Retaining walls, return walls, (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.

157.19

-

-

... More
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

15.34

-

-

... More
50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2

400

-

-

... More
Manhole

-

-

-

... More
19.24.1 : Dismantling of manhole including R.C.C top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials into municipal dumps within 50 m lead:Rectangular manhole 90x80 cm and 45 cm deep

56

-

-

... More
19.25.1 : Extra for depth of manholes dismantled:Rectangular manhole 90x80 cm and beyond 45cm depth

2.8

-

-

... More
19.24.2 : Dismantling of manhole including R.C.C top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials into municipal dumps within 50 m lead:Rectangular manhole 120x90cm and 90 cm deep

2

-

-

... More
19.25.2 : Extra for depth of manholes dismantled:Rectangular manhole 120x90cm and beyond 90 cm depth

0.9

-

-

... More
15.47.1 : Dismantling asbestos cement pressure pipes including excavation and refilling trenches after taking out the pipes manually / by mechanical means and stacking the pipes within 50 metres lead as per direction of Engineer-in-Charge:Upto 150 mm diameter

800

-

-

... More
19.7.1.2 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With Sewer bricks conforming to IS : 4885

56

-

-

... More
19.8.1.2 : Extra for depth for manholesSize 90x80 cmWith Sewer bricks conforming to IS : 4885

2.8

-

-

... More
19.7.2.2 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg):With Sewer bricks conforming to IS : 4885

2

-

-

... More
19.8.2.2 : Extra for depth for manholesSize 120x90 cmWith Sewer bricks conforming to IS: 4885

0.9

-

-

... More
19.6.1 : Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:100 mm dia R.C. C pipe

450

-

-

... More
19.6.2 : Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:150 mm dia R.C.C. pipe

450

-

-

... More
TOILET RENOVATION

-

-

-

... More
15.23.1 : Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm

5609.88

-

-

... More
8.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

3932.02

-

-

... More
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

1677.87

-

-

... More
15.12.1 : Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below

154

-

-

... More
9.117.1 : Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-chargeExtruded section profile size 48x40 mm

765.38

-

-

... More
9.118.2 : Providing and fixing to existing door frames30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge.

284.49

-

-

... More
9.165.1 : Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125 mm

154

-

-

... More
9.101.2 : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper

24

-

-

... More
15.44.1 : Dismantling G.I. pipes ( external work) including excavation and refilling trenches after taking out the pipes, manually / by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer- in- Charges:15 mm to 40 mm nominal bore

1420

-

-

... More
15.44.2 : Dismantling G.I. pipes ( external work) including excavation and refilling trenches after taking out the pipes, manually / by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer- in- Charges:Above 40 mm nominal bore

684

-

-

... More
15.52 : Dismantling of flushing cistern of all types (C.I. / PVC/ Vitrous China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead

113

-

-

... More
18.7.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal outer dia pipes

855

-

-

... More
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes

30

-

-

... More
18.7.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal outer dia pipes

425

-

-

... More
18.9.7 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work62.50 mm nominal inner dia pipes

345

-

-

... More
18.9.9 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work100 mm nominal inner dia pipes

409

-

-

... More
18.22.2 : Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:150 mm diameter

64

-

-

... More
18.51.1 : Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore

62

-

-

... More
18.52.1 : Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore

136

-

-

... More
18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore

403

-

-

... More
18.65 : Providing and fixing PTMT Soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fittings arrangements, weighing not less than 106 gms.

116

-

-

... More
17.1.1 : Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

16

-

-

... More
17.4.1 : Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:One urinal basin with 5 litre white P.V.C. automatic flushing cistern

71

-

-

... More
17.7.1 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps

116

-

-

... More
17.28.2.2 : Flexible pipe40 mm dia

116

-

-

... More
50.17.1.5 : Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

89

-

-

... More
8.10.2 : Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in Charge and finished smooth.Granite Stone of approved shade

26.32

-

-

... More
od298124/2019_2020 : Supplying and Fixing of "MULTI FLOOR TRAP 110 X 75 X 50 mm"

151

-

-

... More
17.2.1 : Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid

97

-

-

... More
14.82 : Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge

300

-

-

... More
14.75 : Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge.

1677.87

-

-

... More
13.82.2 : Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.Two coats

1677.87

-

-

... More
11.48.1 : Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 500x500 mm

1677.87

-

-

... More
od9396/2020_2021 : Providing and laying anti skid Ceramic floor tiles of size 400 x 400 mm or more (thickness to be specified by the manufacturer) of Ist quality conforming to IS: 15622 of approved make in all colours, shades, except white, Ivory, Grey Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete.

1677.87

-

-

... More
11.50 : Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles

1677.87

-

-

... More
Windows Changing

-

-

-

... More
15.12.1 : Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below

900

-

-

... More
15.12.2 : Of area beyond 3 sq. metres

98

-

-

... More
9.147B.1 : 543 SUB HEAD : 9 - WOOD & PVC WORK 9.147B Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately).br Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)

238.62

-

-

... More
9.147D.1 : Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Two track two panels sliding window made of (small series) frame 52 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm)

1170.59

-

-

... More
9.147E.2 : Providing and fixing factory made uPVC white colour sliding glazed window above 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads, uPVC extruded interlocks and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle on one side of extreme panel along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) touch lock with hook (if required for wire mesh panel), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately).br Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Two track four panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 4.00 sqm upto 8.00 sqm).

353.29

-

-

... More
9.147D.5 : Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Three track three panels sliding window made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm)

96.6

-

-

... More
9.7.7.1 : Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:Float glass panes4 mm thick glass pane

1409.21

-

-

... More
9.7.7.2 : Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:5.5mm thick glass pane

449.89

-

-

... More
od77793/2021_2022 : supply and filling of gap between the window frame and wall with weather proof silicon sealent over backerord of required size of approved quality

6010.9

-

-

... More
Fire Pumps & Accessories

-

-

-

... More
od290396/2019_2020 : MAIN PUMP : Supply,Installation,Testing and Commissioning of main fire fighting pump 2280 LPM,70 m Head of horizontal centrifugal End Suction type with cast iron casing, Bronze impeller, coupled to a squirrel cage induction motor SPDP type or mono block pump totally enclosed fan cooled with supply condition 415V 3phas,50Hz foot mounted type rated for suitable HP at 2990 RPM including supply and installation of all accessories such as standard coupling, coupling guard, common base plate and foundation bolts. The pump shall produce a pressure of 3 kg/sq. m at top most hydrant level.

2

-

-

... More
od18010/2021_2022 : SPRINKLER PUMP Supply,Installation,Testing and Commissioning of Sprinkler fire fighting pump 2280 LPM,70 m Head of horizontal centrifugal End Suction type with cast iron casing, Bronze impeller, coupled to a squirrel cage induction motor SPDP type or mono block pump totally enclosed fan cooled with supply condition 415V 3phas,50Hz foot mounted type rated for suitable HP at 2990 RPM including supply and installation of all accessories such as standard coupling, coupling guard, common base plate and foundation bolts. The pump shall produce a pressure of 3 kg/sq. m at top most hydrant level.

2

-

-

... More
od290397/2019_2020 : DIESEL ENGINE DRIVEN PUMP:- Supply Installation, testing and commissioning of Stand By Diesel Engine driven pump Sutable HP with control panel and battery charger of centrifugal end suction type suitable for automatic operation rated for 2280 LPM at 70 m head at high efficiency volute type with cast iron casing, Bronze impeller Pump coupled to a diesel engine at 1800 RPM including supply of all accessories such as common base plate suitable foundation for engine and pump, , suitable size Battery, coolant, lubricating oil, exhaust piping, necessary controls such as pressure switch, gauge and interconnecting cable from control panel to Battery etc.<br>

2

-

-

... More
od290398/2019_2020 : JOCKEY PUMP:Supply and errection of fire fighting pump 180LPM,70 m head horizontal end section.centrifugal multy stage with cast iron casing, Bronze impiller electronic driven auto start Jockey Pump coupled with TEFC motor working on 415V,3Phase, 50Hz with Suitable HP

4

-

-

... More
od290399/2019_2020 : AUTOMATIC CONTROL PANEL MAIN STANDBY AND JOCKEY PUMPS: Supply, installation, testing and commissioning of Automatic Pump Control Panel for Main Standby and Jockey pumps including 1 No. 630A TPN AC 23 A duty <br> 4 Nos. 200A TPN AC 23A duty, <br> 4 Nos. 63A TPN AC 23A duty, <br> 4 Nos Star Delta Starters suitable for 60 HP motors, <br> 4 Nos DOL Starters suitable for 12.5 HP motors, <br> 1 No Aluminum anodized Danger Notice Board of size 200 x 150 mm with inscriptions and conventional Skull & Bone in Red colour <br> 1 No Three phase voltmeter (V-RY,YB,BR,R,Y,B) <br> 1 No 6A 3 pole voltmeter selector switch to read voltage between 3 phases and 3 phase and neutral <br> 1 No LED indicator for all voltage ranges - Red, Green, Black, Yellow or Orange colour <br> 2 Nos 63A TPN SDFU with suitable HRC fuses, 2 Nos Diesel Engine Control consisting of 20A DP C curve control MCB, and 16A On/Off control switch, 3 Nos. Auto/Manual selector switch, 3 attempt starting device, push button etc, all required timers, relays, MCBs and accessories for automatic operation of diesel engine, Indication lamp for high water temperature, engine fail to start, engine ON indication, high/low lube oil pressure, necessary control wiring for start / stop solenoid line /oil pressure switch, temperature switch, pressure switch to fire pump panel diesel engine control cabinet, Battery charger suitable for 12/24 V DC with boost and trickle selector switch, 0-30V voltmeter, 0-20A DC Ammeter x 2 NOS <br> 1 No Spare 63A TPN AC 23A duty.

1

-

-

... More
od290401/2019_2020 : Supplying, Installing, testing and commissioning CI Butterfly valve slim seal standard lever operated type PN.16 with required flanges, nuts, bolts etc. complete.

1

-

-

... More
od290402/2019_2020 : Supply, installation, testing and commissioning of C.I. Non-Return Valve slim seal type PN.16 with required flanges, nuts & bolts, gasket etc. complete

1

-

-

... More
od290403/2019_2020 : AIR RELEASE VALVE:Supply and errection of air release valve as per IS:778 of size 1/2 inch BSP threaded.

30

-

-

... More
od290404/2019_2020 : Ball VALVE:Supply and erection of cast iron Ball valve

12

-

-

... More
od290406/2019_2020 : AIR CUSSION VESSEL: Supply,Installation, Testing and commissioning of Air Cussion Vessel of 250mm dia with automatic air release cock with drain pipe,drain valve and a shut off and 120cm height complete

2

-

-

... More
od290407/2019_2020 : PRESSURE SWITCHES: Supply,Installation, Testing and Commissioning of pressure switches

10

-

-

... More
od290408/2019_2020 : PRESSURE GAUGE: Supply,Installation, Testing and Commissioning of pressure gauge

2

-

-

... More
od290409/2019_2020 : "Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of following sizes as required : 150mm dia"

1

-

-

... More
od290410/2019_2020 : TERRACE PUMP:Supply and erection of fire fighting pump 900 LPM,35 m head horizontal end section.centrifugal multi stage with cast iron casing, Bronze impiller electronic driven auto start Jockey Pump coupled with TEFC motor working on 415V,3Phase,50Hz with Suitable HP

2

-

-

... More
od290411/2019_2020 : TERRACE PUMP:Supply and erection of fire fighting pump 450 LPM,35 m head horizontal end section.centrifugal multi stage with cast iron casing, Bronze impiller electronic driven auto start Jockey Pump coupled with TEFC motor working on 415V,3Phase,50Hz with Sutable HP

9

-

-

... More
od290412/2019_2020 : MOTOR CONTROL PANEL:Supply, installation, testing and commissioning of Automatic Pump Control Panel, Pressure Switch and Pressure Gauge<br>

11

-

-

... More
Fire Hydrant System

-

-

-

... More
od18077/2021_2022 : Above Ground Piping: Supply, erection, testing and commissioning of 150mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports, The pipe shall be painted with one coat of primer and two coats of synthetic enamel paint of approved colour / shade. (Core cutting in walls/beams/columns for laying pipes shall be provided by client, if necessery)

2400

-

-

... More
od18081/2021_2022 : Above Ground Piping: Supply, erection, testing and commissioning of 100mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports, The pipe shall be painted with one coat of primer and two coats of synthetic enamel paint of approved colour / shade. (Core cutting in walls/beams/columns for laying pipes shall be provided by client, if necessery)

520

-

-

... More
od18082/2021_2022 : Above Ground Piping: Supply, erection, testing and commissioning of 80mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports, The pipe shall be painted with one coat of primer and two coats of synthetic enamel paint of approved colour / shade. (Core cutting in walls/beams/columns for laying pipes shall be provided by client, if necessery)

20

-

-

... More
od20281/2021_2022 : Under Ground Piping: Supply, erection, testing and commissioning of 200mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, laying under ground, by using suitable supports and wrapping with polymer corrosion protection tape confirming to IS 10221 with proper overlapping, trimming etc. complete. etc. complete (The Rate for excavation shall be extra as applicable

300

-

-

... More
od20283/2021_2022 : Under Ground Piping: Supply, erection, testing and commissioning of 150mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, laying under ground, by using suitable supports and wrapping with polymer corrosion protection tape confirming to IS 10221 with proper overlapping, trimming etc. complete. etc. complete (The Rate for excavation shall be extra as applicable

3060

-

-

... More
od20285/2021_2022 : Under Ground Piping: Supply, erection, testing and commissioning of 100mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, laying under ground, by using suitable supports and wrapping with polymer corrosion protection tape confirming to IS 10221 with proper overlapping, trimming etc complete. etc. complete (The Rate for excavation shall be extra as applicable

30

-

-

... More
od20287/2021_2022 : Under Ground Piping: Supply, erection, testing and commissioning of 80mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, laying under ground, by using suitable supports and wrapping with polymer corrosion protection tape confirming to IS 10221 with proper overlapping, trimming etc complete. etc. complete (The Rate for excavation shall be extra as applicable

20

-

-

... More
od290420/2019_2020 : BUTTER FLY VALVE: Supplying, Installing, testing and commissioning CI Butterfly valve slim seal standard lever operated type PN.16 with required flanges, nuts, bolts etc. complete.<br><br>a) 150 mm Dia

6

-

-

... More
od290421/2019_2020 : HYDRANT VALVE:- Supply Installation, Testing and commissioning of single headed GUN METAL hydrant valve conforming to IS:5290 and with ISI mark of 63/80 mm Dia oblique type with instantaneous hose coupling adapter.(point-155, YH-38)

193

-

-

... More
od290422/2019_2020 : BRANCH PIPE:- Providing and installation of Branch pipe of 63 mm dia having GUN METAL body with hexagonal head of 20mm dia nozzle conforming to IS903

193

-

-

... More
od290423/2019_2020 : FIRE HOSE:-Supply, installation, testing and commissioning of controlled percolated hose in 15M length of 63 mm dia and tested to bursting pressure of 15kg/sqcm and with SS coupling as per IS:901 <br><br><br>

386

-

-

... More
od290424/2019_2020 : HOSE REEL:-Supply, installation, testing and commissioning of hydraulic hose reel complete with swing type drum,19mm rigid hose having a length of 30 Mtrs. with stop cock and PVC / chrome plated nozzle on one end and all other necessary fixing materials

215

-

-

... More
od290425/2019_2020 : BALL VALVE : Supplying, installing, testing and commissioning of Cast iron Ball valves with fittings of screwed end type.<br><br>a) 20 mm Dia

215

-

-

... More
od290427/2019_2020 : DOUBLE DOOR HOSE CABINET : Supply, installation, testing and commissioning of Double Door Hose Cabinet to accommodate Two piece of hose pipe along with one pair of male and female coupling and one branch pipe. The cabinet is made of 20swg M.S Sheet, glass fronted with hinged door and lock. The cabinet is spray painted to scarlet red color.

193

-

-

... More
od290428/2019_2020 : FIRE BRIGADE INLET/TANK FILLING INLET : Supply, installation, testing and commissioning of Fire Brigade Inlet connection with 4 nos of 63 mm dia. built - in Gun metal Non- return valves instantaneous coupling type arranged on 150 mm dia. etc. Pipe manifold shall be connected to wet riser main.

4

-

-

... More
Sprinkler System

-

-

-

... More
od20736/2021_2022 : Sprinkler Piping: Supply, Installation, Testing and Commissioning of 150mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports, The pipe shall be painted with one coat of primer and two coats of synthetic enamel paint of approved colour / shade. (Core cutting in walls/beams/columns for laying pipes shall be provided by client, if necessary)

300

-

-

... More
od20756/2021_2022 : Sprinkler Piping: Supply, Installation, Testing and Commissioning of 100mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports, The pipe shall be painted with one coat of primer and two coats of synthetic enamel paint of approved colour / shade. (Core cutting in walls/beams/columns for laying pipes shall be provided by client, if necessary)

920

-

-

... More
od20757/2021_2022 : Sprinkler Piping: Supply, Installation, Testing and Commissioning of 80mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports, The pipe shall be painted with one coat of primer and two coats of synthetic enamel paint of approved colour / shade. (Core cutting in walls/beams/columns for laying pipes shall be provided by client, if necessary)

2040

-

-

... More
od20758/2021_2022 : Sprinkler Piping: Supply, Installation, Testing and Commissioning of 65mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports, The pipe shall be painted with one coat of primer and two coats of synthetic enamel paint of approved colour / shade. (Core cutting in walls/beams/columns for laying pipes shall be provided by client, if necessary)

3200

-

-

... More
od20760/2021_2022 : Sprinkler Piping: Supply, Installation, Testing and Commissioning of 50mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports, The pipe shall be painted with one coat of primer and two coats of synthetic enamel paint of approved colour / shade. (Core cutting in walls/beams/columns for laying pipes shall be provided by client, if necessary)

3000

-

-

... More
od20761/2021_2022 : Sprinkler Piping: Supply, Installation, Testing and Commissioning of 40mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports, The pipe shall be painted with one coat of primer and two coats of synthetic enamel paint of approved colour / shade. (Core cutting in walls/beams/columns for laying pipes shall be provided by client, if necessary)

3200

-

-

... More
od20764/2021_2022 : Sprinkler Piping: Supply, Installation, Testing and Commissioning of 32mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports, The pipe shall be painted with one coat of primer and two coats of synthetic enamel paint of approved colour / shade. (Core cutting in walls/beams/columns for laying pipes shall be provided by client, if necessary)

3700

-

-

... More
od20767/2021_2022 : Sprinkler Piping: Supply, Installation, Testing and Commissioning of 25mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports, The pipe shall be painted with one coat of primer and two coats of synthetic enamel paint of approved colour / shade. (Core cutting in walls/beams/columns for laying pipes shall be provided by client, if necessary)

15000

-

-

... More
od20800/2021_2022 : BUTTER FLY VALVE: Supplying, Installing, testing and commissioning 150mm Dia CI Butterfly valve slim seal standard lever operated type PN.16 with required flanges, nuts, bolts etc. complete.

41

-

-

... More
od20802/2021_2022 : BUTTER FLY VALVE: Supplying, Installing, testing and commissioning 80mm Dia CI Butterfly valve slim seal standard lever operated type PN.16 with required flanges, nuts, bolts etc. complete.

6

-

-

... More
od20804/2021_2022 : SPRINKLER BULB: -Supply, installation, testing and commissioning of Pendent type 15mm Sprinkler bulbs designed to operate at 68 deg. Celsius etc. with necessary fittings etc, complete (Extension of Pipeline /Flexible pipe will be at extra cost)

7500

-

-

... More
od20806/2021_2022 : SPRINKLER BULB: -Supply, installation, testing and commissioning of Side Wall/ Upright Type 15mm Sprinkler bulbs designed to operate at 68 deg. Celsius etc. with necessary fittings etc, complete (Extension of Pipeline /Flexible pipe will be at extra cost)

200

-

-

... More
od20807/2021_2022 : SPRINKLER FLEXIBLE PIPE :Supply, installation, testing & commissioning of 1000 mm length stainless steel corrugated flexible pipe (hose) for dropping sprinklers below false ceiling, pipe shall be 16 bar pressure rating and upto 25 mm dia with union / reducer collar, clamps etc. as required.

5

-

-

... More
od20808/2021_2022 : SPRINKLER FLEXIBLE PIPE :Supply, installation, testing & commissioning of 1200 mm length stainless steel corrugated flexible pipe (hose) for dropping sprinklers below false ceiling, pipe shall be 16 bar pressure rating and upto 25 mm dia with union / reducer collar, clamps etc. as required.

5

-

-

... More
od20809/2021_2022 : SPRINKLER FLEXIBLE PIPE :Supply, installation, testing & commissioning of 1500 mm length stainless steel corrugated flexible pipe (hose) for dropping sprinklers below false ceiling, pipe shall be 16 bar pressure rating and upto 25 mm dia with union / reducer collar, clamps etc. as required.

5

-

-

... More
Fire Detection & Alarm System

-

-

-

... More
od290461/2019_2020 : FIRE ALARM CABLE:Supply, laying and clamping of PVC insulated and PVC sheathed armoured copper fire alarm cable 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages, colour washing etc. as required. (2X 1.50 sq mm) <br>

49000

-

-

... More
od290462/2019_2020 : INTELLIGENT ADDRESSABLE HEAT DETECTORS:Supply and errection of ironisation type Heat detectors with imported base <br>

100

-

-

... More
od290463/2019_2020 : INTELLIGENT ADDRESSABLE SMOKE DETECTORS : Supply and erection of ironisation type smoke detectors with imported base <br>

5400

-

-

... More
od290464/2019_2020 : INTELLIGENT ADDRESSABLE ELECTRONIC ALARMING HOOTER:Supply, installation, testing and commissioning of intelligent Electronic Hooter (Sounder) as per standard specification. <br>

142

-

-

... More
od290465/2019_2020 : INTELLIGENT ADDRESSABLE MANUAL CALL POINT: Supply, Installation, testing and commissioning of intelligent Manual Call Point break glass type as per standard specification. <br>

142

-

-

... More
od290466/2019_2020 : REPEATER PANEL :Supply, installation, testing & commissioning of Active repeater panel LCD for monitoring the fire alarm system @ security block.

6

-

-

... More
od290467/2019_2020 : ELECTRONIC ALARMING HOOTER:Supply, installation, testing and commissioning of Electronic Hooter (Sounder) as per standard specification. <br>

25

-

-

... More
od290468/2019_2020 : MANNUAL CALL POINT: Supply, Installation, testing and commissioning of Manual Call Point break glass type as per standard specification.

25

-

-

... More
od290469/2019_2020 : FIRE ALARM PANEL: Supply, installing, testing and commissioning of Micro processor based Main Fire alarm control panel of 6 zones capacity, with visual LED indications for fire / fault alarms, signals and should have stage alarm facility with maintenance free The panel shall be fabricated by M.S. sheet and powder coated both inside & out side, door shall be glass fronted type with locking arrangement, as per specification.<br>

7

-

-

... More
od290470/2019_2020 : FIRE ALARM PANEL: Supply, installing, testing and commissioning of Micro processor based Main Fire alarm control panel of 4 zones capacity, with visual LED indications for fire / fault alarms, signals and should have stage alarm facility with maintenance free The panel shall be fabricated by M.S. sheet and powder coated both inside & out side, door shall be glass fronted type with locking arrangement, as per specification.<br>

3

-

-

... More
od308599/2019_2020 : INTELLIGENT AUTOMATIC FIRE ALARM PANEL: Supply, installing, testing and commissioning of Micro processor based Intelligent Addressible Main Fire alarm control panel of 2 Loop capacity, with visual LED indications for fire / fault alarms, signals and should have stage alarm facility with maintenance free The panel shall be fabricated by M.S. sheet and powder coated both inside & out side, door shall be glass fronted type with locking arrangement, as per specification.

1

-

-

... More
od308600/2019_2020 : INTELLIGENT AUTOMATIC FIRE ALARM PANEL: Supply, installing, testing and commissioning of Micro processor based Intelligent Addressible Main Fire alarm control panel of 6 Loop capacity, with visual LED indications for fire / fault alarms, signals and should have stage alarm facility with maintenance free The panel shall be fabricated by M.S. sheet and powder coated both inside & out side, door shall be glass fronted type with locking arrangement, as per specification.

1

-

-

... More
od308601/2019_2020 : INTELLIGENT AUTOMATIC FIRE ALARM PANEL: Supply, installing, testing and commissioning of Micro processor based Intelligent Addressible Main Fire alarm control panel of 10 Loop capacity, with visual LED indications for fire / fault alarms, signals and should have stage alarm facility with maintenance free The panel shall be fabricated by M.S. sheet and powder coated both inside & out side, door shall be glass fronted type with locking arrangement, as per specification.

2

-

-

... More
Talk Back System

-

-

-

... More
od290472/2019_2020 : CONTROL PANEL:Supply installation testing and commissioning of 16 Zone PA consoled with 80 Watts PA(Ahuja Make) zone talk back selector,Mic, battery charger etc..

1

-

-

... More
od290473/2019_2020 : CONTROL PANEL:Supply installation testing and commissioning of 6 Zone PA consoled with 80 Watts PA(Ahuja Make) 8 zone talk back selector,Mic, battery charger etc..

2

-

-

... More
od290474/2019_2020 : TALK BACK UNIT:Supply installation testing and commissioning of Talk back Unit

21

-

-

... More
od290475/2019_2020 : FIRE ALARM CABLE:Supply, laying and clamping of PVC insulated and PVC sheathed armoured copper fire alarm cable 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages, colour washing etc. as required. (2X 1.50 sq mm)

600

-

-

... More
Fire Extinguishers

-

-

-

... More
od290477/2019_2020 : CO2 Extinguisher :Supply and erection of Co2 type fire extinguisher with 4.5 Kg capacity as per IS:2171

25

-

-

... More
od290478/2019_2020 : DCP: Supply and erection of dry chemical powder type fire extinguisher with 4Kg capacity as per IS:2171

250

-

-

... More
Signages

-

-

-

... More
od290479/2019_2020 : SELF GLOWING SIGNAGES:Supply and errection of Self Glowing Sign boards made out of 3 mm thick PVC form board size:12"x 4" (FIRE LIFT , EXIT,FIRE EXIT,FIRE STATION)<br>

1200

-

-

... More
od290480/2019_2020 : Suply and providing emergency fire escape lighting system consisting 2 nos lamp ,7 AH FMF battary charging unit ,exit sign display etc in MS enclosure<br>

100

-

-

... More
FALSE CEILING

-

-

-

... More
15.57 : Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge

1012.05

-

-

... More
12.52.1 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending

1012.05

-

-

... More
Light Fittings

-

-

-

... More
od265248/2019_2020 : "Supplying and fixing of indoor industrial surface mounted LED commercial Batten light with driver surge protector,system wattage of 18+/- watts lumen output of lamp greater than 1600 lumen, power factor >0.9 rated life of L70@ 50,000 hours,system efficiency greeter than 70 lumen/watt and including all necessary accessories as required complete.<br>

655

-

-

... More
od265249/2019_2020 : "Supply and fixing of indoor industrial surface mounted LED commercial Batten light with driver surge protector,system wattage of 30+/- watts lumen output of lamp greater than 3000 lumen, power factor >0.9 rated life of L70@ 50,000 hours,system efficiency greater than 70 lumen/watt and including all necessary accessories as required complete.<br>

1865

-

-

... More
od265310/2019_2020 : "Supplying and fixing of industrial surface mounted Full lit linear LED commercial Light standard 1x 4 double Decker type with driver surge protector,system wattage of 36 +/- watts lumen output of lamp greater than 3000 lumen, power factor >0.9 rated life of L 70@ 50,000 hours,system efficiency greater than 70 lumen/watt and including all necessary accessories as required complete."<br>

1501

-

-

... More
od265311/2019_2020 : "Supplying and fixing of Moon Std LED Recess commercial light with driver surge protector,system wattage of 15+/- watts lumen output of lamp greater than 800 lumen, power factor >0.9 rated life of L70@ 50,000 hours,system efficiency greater than 70 lumen/watt and including all necessary accessories as required complete."<br>

60

-

-

... More
od265312/2019_2020 : "Supplying and fixing of Texon Std Recess commercial tech zone 1200 x 150 mm light with driver surge protector,system wattage of 24+/- watts lumen output of lamp greater than 2000 lumen, power factor >0.9 rated life of L70 @ 50,000 hours,system efficiency greater than 70 lumen/watt and including all necessary accessories as required complete. "<br>

400

-

-

... More
od265313/2019_2020 : "Supplying and fixing of Cask Bulk Head LED Wall Mounted 4000 k industrial light with driver surge protector,system wattage of 12+/- watts lumen output of lamp greater than 800 lumen, power factor >0.9 rated life of L70@ 50,000 hours,system efficiency greater than 70 lumen/watt and including all necessarily accessories as required complete."<br>

14

-

-

... More
od265314/2019_2020 : Supplying and fixing of LT MAZE XL LED Wall Mounted 6500 K,IP 66 light with driver surge protector,system wattage of 1.44+/- watts lumen output of lamp greater than 150 lumen, power factor >0.9 rated and including all necessary accessories as required complete.<br>

7012

-

-

... More
od265315/2019_2020 : "Supplying and fixing of LT 100 W ,12 V Power supply with IP 67 protection"

140

-

-

... More
od265364/2019_2020 : "Supplying and fixing of Sparkle Ultra LED Recess commercial light with driver surge protector,system wattage of 28+/- watts lumen output of lamp greater than 2800 lumen, power factor >0.9 rated life of L70@ 50,000 hours,system efficiency greater than 70 lumen/watt and including all necessary accessories as required complete."<br>

80

-

-

... More
Switch/Socket/Regulator replacement

-

-

-

... More
1.23.1 : Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.5/6 amps switch

2996

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

1098

-

-

... More
1.29 : Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings).

2310

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

286

-

-

... More
od141773/2021_2022 : DSOR 2018 Item 1.32<br> Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

827

-

-

... More
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

1079

-

-

... More
LEVEL-1 (CHILLER REPLACEMENT)

-

-

-

... More
od289841/2019_2020 : Supply, Shifting, Installation, Testing & Commissioning of air cooled Inverter scroll chiller Units with Multiple Inverter type scroll compressors, Dx type shell & tube Evaporator, Air-cooled condenser with protective black epoxy resin and hydrophilic coating for Aluminum fins, BLDC (Brush less Direct commuting) condenser fans to regulate fan speed as per cooling load requirements, Control Panels and Pre-charged R410 A Refrigerant. <br>Air cooled Inverter Scroll Chiller 35 TR Capacity<br>

2

-

-

... More
od289846/2019_2020 : Supply, Shifting, Installation, Testing & Commissioning of Horizontal split casing chilled water pump sets complete with TEFC sq.cage induction motor (With Mechanical seal) stainless steel shaft, bronze impeller, base plate, couplings, pressure gauges (2 Nos. with syphon and gauge cock), anti vibration springs, guards etc. including insulation as per specifications: <br>Chiller water Pumpsets 100 USGPM@3.5 Bar.

2

-

-

... More
16.1.8 : INSULATED CHILLED WATER PIPING (resin bonded fiber glass glass INSULATION) br Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with 80 kg/cum density resin bonded fiber glass or 144 Kg/ cu m density mineral wool (non Combustible) pipe section insulation covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints and repairing of damage to building etc. as per specifications and as required. br Note: The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 100mm dia. (50mm thick fiber glass insulation)

10

-

-

... More
16.7.1.5 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedBUTTERFLY VALVE (MANUAL) 80 mm

4

-

-

... More
16.7.1.6 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedButterfly valve (Manual) 65 mm

4

-

-

... More
16.7.3.5 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.NON- RETURN VALVE with duel plate of C I body SS plated vulcanized NBR Seal flanged end & PN 16 pressure rating for chilled/ hot water circulation including insulation as specified.NON- RETURN VALVE of 80 mm dia

2

-

-

... More
16.7.4.5 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specifiedY- Strainer of 80 mm dia

2

-

-

... More
16.8 : Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required

4

-

-

... More
16.9 : Providing & fixing in position the mercury in glass industrial type thermometers.

4

-

-

... More
od289933/2019_2020 : Dismantling and unloading of chillers 30 TR near cardio OT<br>

2

-

-

... More
od289934/2019_2020 : Supply and Installation of Flexible connections of suitable pressure rating to be installed at CHILLERS, Pump sets inlets & outlets and at pipes crossing building expansion joints as per Specifications. <br>

8

-

-

... More
od289935/2019_2020 : Supply Installation, Testing and commissioning of air vent<br>

2

-

-

... More
16.1.9 : INSULATED CHILLED WATER PIPING (resin bonded fiber glass glass INSULATION) br Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with 80 kg/cum density resin bonded fiber glass or 144 Kg/ cu m density mineral wool (non Combustible) pipe section insulation covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints and repairing of damage to building etc. as per specifications and as required. br Note: The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 80mm dia. (50mm thick fiber glass insulation)

10

-

-

... More
16.7.2.5 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Balancing valve with built in measuring facility with C.I Body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled /hot water circulation as specified.Balancing valve with built in measuring facility 80 mm dia

2

-

-

... More
16.11.3.8 : Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valves with Cl Body, SS Disc,O - ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC and upto 20mA electric signal and providing similar transduced feedback output to control system as required.80mm dia.

2

-

-

... More
STANDBY CHILLER TERRACE LEVEL

-

-

-

... More
od289895/2019_2020 : Supply, Shifting, Installation, Testing & Commissioning of air cooled Inverter scroll chiller Units with Multiple Inverter type scroll compressors, Dx type shell & tube Evaporator, Air-cooled condenser with protective black epoxy resin and hydrophilic coating for Aluminum fins, BLDC (Brush less Direct commuting) condenser fans to regulate fan speed as per cooling load requirements, Control Panels and Pre-charged R410 A Refrigerant.<br>Air cooled Inverter Scroll Chiller 70 TR Capacity

1

-

-

... More
16.1.8 : INSULATED CHILLED WATER PIPING (resin bonded fiber glass glass INSULATION) br Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with 80 kg/cum density resin bonded fiber glass or 144 Kg/ cu m density mineral wool (non Combustible) pipe section insulation covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints and repairing of damage to building etc. as per specifications and as required. br Note: The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 100mm dia. (50mm thick fiber glass insulation)

10

-

-

... More
od141557/2021_2022 : <br>DSOR 2018 Item 16.7.1.4<br>16.7 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.<br>16.7.1 : BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specified<br>16.7.1.3 : Butterfly valve (Manual) 125 mm<br><br><br>

2

-

-

... More
16.7.2.4 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Balancing valve with built in measuring facility with C.I Body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled /hot water circulation as specified.Balancing valve with built in measuring facility 100 mm dia

2

-

-

... More
16.7.3.4 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.NON- RETURN VALVE with duel plate of C I body SS plated vulcanized NBR Seal flanged end & PN 16 pressure rating for chilled/ hot water circulation including insulation as specified.NON- RETURN VALVE 100 mm dia

4

-

-

... More
16.7.4.4 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specifiedY- Strainer of 100 mm dia

4

-

-

... More
16.8 : Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required

2

-

-

... More
16.9 : Providing & fixing in position the mercury in glass industrial type thermometers.

2

-

-

... More
16.11.3.7 : Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valves with Cl Body, SS Disc,O - ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC and upto 20mA electric signal and providing similar transduced feedback output to control system as required.100mm dia.

1

-

-

... More
od289935/2019_2020 : Supply Installation, Testing and commissioning of air vent<br>

2

-

-

... More
LEVEL-1 (Hrudyalaya)

-

-

-

... More
od28782/2021_2022 : Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units <br>suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules,<br>microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant,vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required<br>38 HP Outdoor Unit

2

-

-

... More
od290050/2019_2020 : Supply, Installation, Testing commissioning of AHU Kit and communication Kit between AHU and VRF ODU<br>

2

-

-

... More
od290051/2019_2020 : "Supply and Errection of MS Structure works with I - beam and Chequer plates <br>Room size ( 5 mtr x 3.1 mtr x 8 mtr) ( approx 2000 kg)"<br>

1

-

-

... More
od290052/2019_2020 : "Supply, Installation, Testing and commissioning of Drain Water Piping P.V.C with nitrile insulation complete with fittings.<br>suitable size as per number of units connected<br>40mm"<br>

10

-

-

... More
od290053/2019_2020 : "Control Cabling<br>Supply, Installation, Testing and commissioning of Control cabling with saddles / supports to connect outdoor units with respective indoor units"

60

-

-

... More
od290054/2019_2020 : Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping complete with fittings, with suitable adjustable hanger supports, jointing/brazing including accessories, insulated with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required <br>

50

-

-

... More
od290055/2019_2020 : "Supply , Installation testing and commissioning of INDOOR UNITS (AHU) - cordless remote and all refnet joints. Air Handling Unit shall be Double Skinned (Outer skin - 0.6mm pre-coated GSS and Inner skin 0.6mm Plain GSS) with 40mm thick PUF panels, Floor Mounted AHU with Mixing box, Filter section with Pre Filter & Fine Filter, Coil section with 6 row deep DX cooling coil, Fan section with direct driven type backward curved plug fans with IE-2 motor & VFD connecting to VRF ODU"<br>AHU 30 TR, 12000 CFM & 500 Pa ESP

2

-

-

... More
16.12.2.2 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick

90

-

-

... More
16.23.2 : INSULATION ON EXISTING PIPE br 16.4 Supplying, laying/ fixing, testing and commissioning of following thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on existing pipe and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required.Nitrille rubber insulation - 25 mm

100

-

-

... More
od290088/2019_2020 : "DUCT ACCOUSTIC INSULATION:-<br>Supply, Installation, Testing and commissioning of Open cell Nitrile rubber thermal insulation with 25mm thickness, 150 kg/m3 Density"<br>

40

-

-

... More
od290091/2019_2020 : Cleaning and Testing of Existing Ducts<br>

1

-

-

... More
od290092/2019_2020 : Dismantling and unloading of PAC and Outdoor units ( For hridyalyam)<br>

4

-

-

... More
LEVEL-1 (Cardio OT)

-

-

-

... More
od290094/2019_2020 : Chilled Water Manifold size suitable to AHU includes 2 Nos. Butterfly / Ball Valves, 1 No. Balancing valve, 1 No. Y-strainer, 1 No. 2 Way Valve with thermostat (with interconnected wiring between thermostat & mixing valve), 2 Nos. dial type Pressure gauges, 2 Nos. temperature Gauges, 1 No drain valve with MS 'C' class 6 m pipe for interconnection with insulation. <br>

1

-

-

... More
od290095/2019_2020 : "Return riser plenums<br>Supply, Installation, balancing and commissioning of Aluminium sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required"<br>

80

-

-

... More
od290097/2019_2020 : "Supply, Installation, Testing & Commissioning of plenum box and Hepa filter for laminar flow system<br>(8 x 4)"<br>

4

-

-

... More
od290098/2019_2020 : AIR HANDLING UNITS FOR EXISTING CHILLER :-Supply, Installation, Testing, Commissioning and Validation of Air Handling units. Air Handling Unit shall be Double Skinned (Outer skin - 0.6mm pre-coated GSS and Inner skin 0.6mm Plain Al) with 40mm thick PUF panels, Floor Mounted with Mixing box, Filter section with Pre Filter, Fine Filter & HEPA Filter, Coil section with 6 row deep CHW cooling coil, Fan section with direct driven type backward curved plug fans with IE-2 motor & VFD, UV lamp and all other accessories complete. <br>AHU 24 TR, 9600 CFM & 500 Pa (Approx.) ESP

2

-

-

... More
16.3.11 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.br Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 50mm dia. (50mm thick expanded polysterene)

5

-

-

... More
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

6

-

-

... More
od140739/2021_2022 : DSOR 2018 Item 16.16<br>Supplying & Fixing of powder coated extruded aluminium Return Air Grilles with louvers but without volume control dampers complete as required<br>

6

-

-

... More
16.12.2.1 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick

5

-

-

... More
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper

0.5

-

-

... More
od290099/2019_2020 : Dismantling and unloading of AHU ( Cardio OT)<br>

2

-

-

... More
od290100/2019_2020 : Supply, Insulation, testing and commissioning of Fresh Air Louvere with bird screen<br>

0.5

-

-

... More
LEVEL-2 (EMERGENCY AREA)

-

-

-

... More
od290105/2019_2020 : "Supply, Installation, Testing and commissioning of Drain Water Piping P.V.C with nitrile insulation complete with fittings.<br>suitable size as per number of units connected<br>25 mm"<br>

5

-

-

... More
od290106/2019_2020 : "Control Cabling<br>Supply, Installation, Testing and commissioning of Control cabling with saddles / supports to connect outdoor units with respective indoor units"<br>

20

-

-

... More
od290107/2019_2020 : Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping complete with fittings, with suitable adjustable hanger supports, jointing/brazing including accessories, insulated with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required <br>

15

-

-

... More
od290108/2019_2020 : "Supply, Installation, Testing & Commissioning of HIGH STATIC INVERTER DUCTABLE:<br>Ceiling Mounted Inverter Ductable Type AC Units suitable to operate at 48°C ambient temperature comprising of Combination of hermetic inverter compressors, Matching air cooled condenser with copper tubes and aluminium fins duly covered by anti-corrosion and hydrophilic resin film, complete with high/low pressure cut-outs, oil pressure failure switch, fan motor, safety thermostat, over current relay, fusible plugs, fuses, cabling, etc. and suitable for operation on 380V~415V~3Ph~50Hz A.C. supply. Oil separator suitable for the refrigerant piping, Accumulator, liquid and gas shut-off valves and solenoid valves/modulation valve with fittings to interconnect compressor, condenser and evaporator coils of following capacities of the ODU and IDU. ( 8.5 TR)"

1

-

-

... More
od290100/2019_2020 : Supply, Insulation, testing and commissioning of Fresh Air Louvere with bird screen<br>

0.25

-

-

... More
od290088/2019_2020 : "DUCT ACCOUSTIC INSULATION:-<br>Supply, Installation, Testing and commissioning of Open cell Nitrile rubber thermal insulation with 25mm thickness, 150 kg/m3 Density"<br>

5

-

-

... More
od290109/2019_2020 : Supply, Installation , Testing and commsiioing of Non - return dampers / Back draft dampers to restrict flow to the blower motor of stand by machine<br>

0.5

-

-

... More
16.12.2.1 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick

3

-

-

... More
16.12.2.2 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick

5

-

-

... More
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper

0.25

-

-

... More
16.23.2 : INSULATION ON EXISTING PIPE br 16.4 Supplying, laying/ fixing, testing and commissioning of following thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on existing pipe and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required.Nitrille rubber insulation - 25 mm

5

-

-

... More
LEVEL-2 (CONFERENCE HALL)

-

-

-

... More
od290114/2019_2020 : "Supply, Installation, Testing & Commissioning of HIGH STATIC INVERTER DUCTABLE:<br>Ceiling Mounted Inverter Ductable Type AC Units suitable to operate at 48°C ambient temperature comprising of Combination of hermetic inverter compressors, Matching air cooled condenser with copper tubes and aluminium fins duly covered by anticorrosion and hydrophilic resin film, complete with high/low pressure cut-outs, oil pressure failure switch, fan motor, safety thermostat, over current relay, fusible plugs, fuses, cabling, etc. and suitable for operation on 380V~415V~3Ph~50Hz A.C. supply. Oil separator suitable for the refrigerant piping, Accumulator, liquid and gas shut-off valves and solenoid valves/modulation valve with fittings to interconnect compressor, condenser and evaporator coils of following capacities of the ODU and IDU. ( 11 TR)<br>"<br>

1

-

-

... More
od290105/2019_2020 : "Supply, Installation, Testing and commissioning of Drain Water Piping P.V.C with nitrile insulation complete with fittings.<br>suitable size as per number of units connected<br>25 mm"<br>

10

-

-

... More
od290106/2019_2020 : "Control Cabling<br>Supply, Installation, Testing and commissioning of Control cabling with saddles / supports to connect outdoor units with respective indoor units"<br>

25

-

-

... More
od290107/2019_2020 : Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping complete with fittings, with suitable adjustable hanger supports, jointing/brazing including accessories, insulated with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required <br>

10

-

-

... More
od290088/2019_2020 : "DUCT ACCOUSTIC INSULATION:-<br>Supply, Installation, Testing and commissioning of Open cell Nitrile rubber thermal insulation with 25mm thickness, 150 kg/m3 Density"<br>

10

-

-

... More
16.12.2.2 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick

25

-

-

... More
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper

1

-

-

... More
od140739/2021_2022 : DSOR 2018 Item 16.16<br>Supplying & Fixing of powder coated extruded aluminium Return Air Grilles with louvers but without volume control dampers complete as required<br>

6

-

-

... More
16.23.2 : INSULATION ON EXISTING PIPE br 16.4 Supplying, laying/ fixing, testing and commissioning of following thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on existing pipe and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required.Nitrille rubber insulation - 25 mm

25

-

-

... More
LEVEL-3 (CENTRAL LAB)

-

-

-

... More
od28783/2021_2022 : Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units<br>suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules,<br>microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant,vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required<br>24 HP Outdoor Unit

1

-

-

... More
od290152/2019_2020 : Dismantling and unloading of PAC and Outdoor units<br>

1

-

-

... More
od290153/2019_2020 : Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping complete with fittings, with suitable adjustable hanger supports, jointing/brazing including accessories, insulated with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required

30

-

-

... More
od290154/2019_2020 : "Supply , Installation testing and commissioning of INDOOR UNITS (AHU) - cordless remote and all refnet joints. Air Handling Unit shall be Double Skinned (Outer skin - 0.6mm pre-coated GSS and Inner skin 0.6mm Plain GSS) with 40mm thick PUF panels, Floor Mounted AHU with Mixing box, Filter section with Pre Filter & Fine Filter, Coil section with 6 row deep DX cooling coil, Fan section with direct driven type backward curved plug fans with IE-2 motor & VFD connecting to VRF ODU<br>(Central Lab area )<br>19.5 TR, 7800 CFM, 450 CFM FA, 500 Pa ESP"

1

-

-

... More
od290100/2019_2020 : Supply, Insulation, testing and commissioning of Fresh Air Louvere with bird screen<br>

0.5

-

-

... More
od290088/2019_2020 : "DUCT ACCOUSTIC INSULATION:-<br>Supply, Installation, Testing and commissioning of Open cell Nitrile rubber thermal insulation with 25mm thickness, 150 kg/m3 Density"<br>

5

-

-

... More
od290050/2019_2020 : Supply, Installation, Testing commissioning of AHU Kit and communication Kit between AHU and VRF ODU<br>

1

-

-

... More
od290052/2019_2020 : "Supply, Installation, Testing and commissioning of Drain Water Piping P.V.C with nitrile insulation complete with fittings.<br>suitable size as per number of units connected<br>40mm"<br>

5

-

-

... More
od290053/2019_2020 : "Control Cabling<br>Supply, Installation, Testing and commissioning of Control cabling with saddles / supports to connect outdoor units with respective indoor units"

40

-

-

... More
16.12.2.1 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick

5

-

-

... More
16.12.2.2 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick

10

-

-

... More
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper

0.5

-

-

... More
16.23.2 : INSULATION ON EXISTING PIPE br 16.4 Supplying, laying/ fixing, testing and commissioning of following thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on existing pipe and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required.Nitrille rubber insulation - 25 mm

10

-

-

... More
LEVEL-3 (BLOOD BANK)

-

-

-

... More
od290153/2019_2020 : Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping complete with fittings, with suitable adjustable hanger supports, jointing/brazing including accessories, insulated with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required

30

-

-

... More
od290154/2019_2020 : "Supply , Installation testing and commissioning of INDOOR UNITS (AHU) - cordless remote and all refnet joints. Air Handling Unit shall be Double Skinned (Outer skin - 0.6mm pre-coated GSS and Inner skin 0.6mm Plain GSS) with 40mm thick PUF panels, Floor Mounted AHU with Mixing box, Filter section with Pre Filter & Fine Filter, Coil section with 6 row deep DX cooling coil, Fan section with direct driven type backward curved plug fans with IE-2 motor & VFD connecting to VRF ODU<br>(Central Lab area )<br>19.5 TR, 7800 CFM, 450 CFM FA, 500 Pa ESP"

1

-

-

... More
od290109/2019_2020 : Supply, Installation , Testing and commsiioing of Non - return dampers / Back draft dampers to restrict flow to the blower motor of stand by machine<br>

0.5

-

-

... More
od290100/2019_2020 : Supply, Insulation, testing and commissioning of Fresh Air Louvere with bird screen<br>

0.5

-

-

... More
od290088/2019_2020 : "DUCT ACCOUSTIC INSULATION:-<br>Supply, Installation, Testing and commissioning of Open cell Nitrile rubber thermal insulation with 25mm thickness, 150 kg/m3 Density"<br>

20

-

-

... More
od290050/2019_2020 : Supply, Installation, Testing commissioning of AHU Kit and communication Kit between AHU and VRF ODU<br>

2

-

-

... More
od290052/2019_2020 : "Supply, Installation, Testing and commissioning of Drain Water Piping P.V.C with nitrile insulation complete with fittings.<br>suitable size as per number of units connected<br>40mm"<br>

15

-

-

... More
od290053/2019_2020 : "Control Cabling<br>Supply, Installation, Testing and commissioning of Control cabling with saddles / supports to connect outdoor units with respective indoor units"

40

-

-

... More
od28783/2021_2022 : Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units<br>suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules,<br>microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant,vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required<br>24 HP Outdoor Unit

1

-

-

... More
16.12.2.1 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick

5

-

-

... More
16.12.2.2 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick

50

-

-

... More
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper

2.5

-

-

... More
16.23.2 : INSULATION ON EXISTING PIPE br 16.4 Supplying, laying/ fixing, testing and commissioning of following thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on existing pipe and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required.Nitrille rubber insulation - 25 mm

50

-

-

... More
LEVEL-5 (NEW BORN BABY)

-

-

-

... More
od290170/2019_2020 : Dismantling and unloading of PAC and Outdoor units<br>

1

-

-

... More
od290171/2019_2020 : Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping complete with fittings, with suitable adjustable hanger supports, jointing/brazing including accessories, insulated with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required <br>

30

-

-

... More
od290172/2019_2020 : "Supply , Installation testing and commissioning of INDOOR UNITS (AHU) - cordless remote and all refnet joints. Air Handling Unit shall be Double Skinned (Outer skin - 0.6mm pre-coated GSS and Inner skin 0.6mm Plain GSS) with 40mm thick PUF panels, Floor Mounted AHU with Mixing box, Filter section with Pre Filter & Fine Filter, Coil section with 6 row deep DX cooling coil, Fan section with direct driven type backward curved plug fans with IE-2 motor & VFD connecting to VRF ODU<br>16 TR, 6400 CFM, 250 CFM FA & 500 Pa ESP "<br>

1

-

-

... More
od290109/2019_2020 : Supply, Installation , Testing and commsiioing of Non - return dampers / Back draft dampers to restrict flow to the blower motor of stand by machine<br>

0.5

-

-

... More
od290100/2019_2020 : Supply, Insulation, testing and commissioning of Fresh Air Louvere with bird screen<br>

0.5

-

-

... More
od290088/2019_2020 : "DUCT ACCOUSTIC INSULATION:-<br>Supply, Installation, Testing and commissioning of Open cell Nitrile rubber thermal insulation with 25mm thickness, 150 kg/m3 Density"<br>

5

-

-

... More
od290050/2019_2020 : Supply, Installation, Testing commissioning of AHU Kit and communication Kit between AHU and VRF ODU<br>

2

-

-

... More
od290052/2019_2020 : "Supply, Installation, Testing and commissioning of Drain Water Piping P.V.C with nitrile insulation complete with fittings.<br>suitable size as per number of units connected<br>40mm"<br>

5

-

-

... More
od290053/2019_2020 : "Control Cabling<br>Supply, Installation, Testing and commissioning of Control cabling with saddles / supports to connect outdoor units with respective indoor units"

40

-

-

... More
od28784/2021_2022 : Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units<br>suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules,<br>microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant,vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required<br>20 HP Outdoor Unit

1

-

-

... More
16.12.2.1 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick

5

-

-

... More
16.12.2.2 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick

10

-

-

... More
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper

2.5

-

-

... More
16.23.2 : INSULATION ON EXISTING PIPE br 16.4 Supplying, laying/ fixing, testing and commissioning of following thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on existing pipe and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required.Nitrille rubber insulation - 25 mm

10

-

-

... More
LEVEL-6 (A WING) (OT-13,14,15,16)

-

-

-

... More
od290277/2019_2020 : Dismantling and unloading of AHU <br>

4

-

-

... More
od290278/2019_2020 : <br>AIR HANDLING UNITS FOR EXISTING CHILLER :-Supply, Installation, Testing, Commissioning and Validation of Air Handling units. Air Handling Unit shall be Double Skinned (Outer skin - 0.6mm pre-coated GSS and Inner skin 0.6mm Plain Al) with 40mm thick PUF panels, Floor Mounted with Mixing box, Filter section with Pre Filter, Fine Filter & HEPA Filter, Coil section with 6 row deep CHW cooling coil, Fan section with direct driven type backward curved plug fans with IE-2 motor & VFD, UV lamp and all other accessories complete. <br>AHU 8 TR, 4000 CFM & 500 Pa (Approx.) ESP

2

-

-

... More
od290279/2019_2020 : AIR HANDLING UNITS FOR EXISTING CHILLER :-Supply, Installation, Testing, Commissioning and Validation of Air Handling units. Air Handling Unit shall be Double Skinned (Outer skin - 0.6mm pre-coated GSS and Inner skin 0.6mm Plain Al) with 40mm thick PUF panels, Floor Mounted with Mixing box, Filter section with Pre Filter, Fine Filter & HEPA Filter, Coil section with 6 row deep CHW cooling coil, Fan section with direct driven type backward curved plug fans with IE-2 motor & VFD, UV lamp and all other accessories complete. <br>AHU 7.5 TR, 3600 CFM & 500 Pa (Approx.) ESP

2

-

-

... More
od290100/2019_2020 : Supply, Insulation, testing and commissioning of Fresh Air Louvere with bird screen<br>

2

-

-

... More
od290052/2019_2020 : "Supply, Installation, Testing and commissioning of Drain Water Piping P.V.C with nitrile insulation complete with fittings.<br>suitable size as per number of units connected<br>40mm"<br>

10

-

-

... More
od290282/2019_2020 : Chilled Water Manifold size suitable to AHU includes 2 Nos. Butterfly / Ball Valves, 1 No. Balancing valve, 1 No. Y-strainer, 1 No. 2 Way Valve with thermostat (with interconnected wiring between thermostat & mixing valve), 2 Nos. dial type Pressure gauges, 2 Nos. temperature Gauges, 1 No drain valve with MS 'C' class 6 m pipe for interconnection with insulation. <br>

4

-

-

... More
16.3.11 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.br Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 50mm dia. (50mm thick expanded polysterene)

20

-

-

... More
16.12.2.1 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick

20

-

-

... More
16.12.2.2 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick

50

-

-

... More
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

6

-

-

... More
od140739/2021_2022 : DSOR 2018 Item 16.16<br>Supplying & Fixing of powder coated extruded aluminium Return Air Grilles with louvers but without volume control dampers complete as required<br>

6

-

-

... More
16.23.2 : INSULATION ON EXISTING PIPE br 16.4 Supplying, laying/ fixing, testing and commissioning of following thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on existing pipe and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required.Nitrille rubber insulation - 25 mm

50

-

-

... More
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper

2

-

-

... More
LEVEL-6 (K WING) (OT 7,8,9,10,11,12)

-

-

-

... More
od290288/2019_2020 : <br>AIR HANDLING UNITS FOR EXISTING CHILLER :-Supply, Installation, Testing, Commissioning and Validation of Air Handling units. Air Handling Unit shall be Double Skinned (Outer skin - 0.6mm pre-coated GSS and Inner skin 0.6mm Plain Al) with 40mm thick PUF panels, Floor Mounted with Mixing box, Filter section with Pre Filter, Fine Filter & HEPA Filter, Coil section with 6 row deep CHW cooling coil, Fan section with direct driven type backward curved plug fans with IE-2 motor & VFD, UV lamp and all other accessories complete. <br>AHU 18 TR, 7500 CFM & 500 Pa (Approx.) ESP

1

-

-

... More
od290289/2019_2020 : <br>AIR HANDLING UNITS FOR EXISTING CHILLER :-Supply, Installation, Testing, Commissioning and Validation of Air Handling units. Air Handling Unit shall be Double Skinned (Outer skin - 0.6mm pre-coated GSS and Inner skin 0.6mm Plain Al) with 40mm thick PUF panels, Floor Mounted with Mixing box, Filter section with Pre Filter, Fine Filter & HEPA Filter, Coil section with 6 row deep CHW cooling coil, Fan section with direct driven type backward curved plug fans with IE-2 motor & VFD, UV lamp and all other accessories complete. <br>AHU 5.5 TR, 2400 CFM & 500 Pa (Approx.) ESP

2

-

-

... More
od290290/2019_2020 : AIR HANDLING UNITS FOR EXISTING CHILLER :-Supply, Installation, Testing, Commissioning and Validation of Air Handling units. Air Handling Unit shall be Double Skinned (Outer skin - 0.6mm pre-coated GSS and Inner skin 0.6mm Plain Al) with 40mm thick PUF panels, Floor Mounted with Mixing box, Filter section with Pre Filter, Fine Filter & HEPA Filter, Coil section with 6 row deep CHW cooling coil, Fan section with direct driven type backward curved plug fans with IE-2 motor & VFD, UV lamp and all other accessories complete. <br>AHU 5.5 TR, 2600 CFM & 500 Pa (Approx.) ESP

1

-

-

... More
od290282/2019_2020 : Chilled Water Manifold size suitable to AHU includes 2 Nos. Butterfly / Ball Valves, 1 No. Balancing valve, 1 No. Y-strainer, 1 No. 2 Way Valve with thermostat (with interconnected wiring between thermostat & mixing valve), 2 Nos. dial type Pressure gauges, 2 Nos. temperature Gauges, 1 No drain valve with MS 'C' class 6 m pipe for interconnection with insulation. <br>

4

-

-

... More
od290277/2019_2020 : Dismantling and unloading of AHU <br>

4

-

-

... More
od290100/2019_2020 : Supply, Insulation, testing and commissioning of Fresh Air Louvere with bird screen<br>

2

-

-

... More
od290095/2019_2020 : "Return riser plenums<br>Supply, Installation, balancing and commissioning of Aluminium sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required"<br>

40

-

-

... More
od290097/2019_2020 : "Supply, Installation, Testing & Commissioning of plenum box and Hepa filter for laminar flow system<br>(8 x 4)"<br>

2

-

-

... More
od290052/2019_2020 : "Supply, Installation, Testing and commissioning of Drain Water Piping P.V.C with nitrile insulation complete with fittings.<br>suitable size as per number of units connected<br>40mm"<br>

20

-

-

... More
16.3.11 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.br Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 50mm dia. (50mm thick expanded polysterene)

20

-

-

... More
16.12.2.1 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick

20

-

-

... More
16.12.2.2 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick

50

-

-

... More
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper

2

-

-

... More
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

6

-

-

... More
od140739/2021_2022 : DSOR 2018 Item 16.16<br>Supplying & Fixing of powder coated extruded aluminium Return Air Grilles with louvers but without volume control dampers complete as required<br>

6

-

-

... More
16.23.2 : INSULATION ON EXISTING PIPE br 16.4 Supplying, laying/ fixing, testing and commissioning of following thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on existing pipe and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required.Nitrille rubber insulation - 25 mm

50

-

-

... More
LEVEL - 6 ( J WING ) ( OT 1,2,3,4,5,6)

-

-

-

... More
od290296/2019_2020 : Dismantling and unloading of AHU <br>

4

-

-

... More
od290297/2019_2020 : AIR HANDLING UNITS FOR EXISTING CHILLER :-Supply, Installation, Testing, Commissioning and Validation of Air Handling units. Air Handling Unit shall be Double Skinned (Outer skin - 0.6mm pre-coated GSS and Inner skin 0.6mm Plain Al) with 40mm thick PUF panels, Floor Mounted with Mixing box, Filter section with Pre Filter, Fine Filter & HEPA Filter, Coil section with 6 row deep CHW cooling coil, Fan section with direct driven type backward curved plug fans with IE-2 motor & VFD, UV lamp and all other accessories complete. <br>AHU 18 TR, 7500 CFM & 500 Pa (Approx.) ESP

1

-

-

... More
od290298/2019_2020 : AIR HANDLING UNITS FOR EXISTING CHILLER :-Supply, Installation, Testing, Commissioning and Validation of Air Handling units. Air Handling Unit shall be Double Skinned (Outer skin - 0.6mm pre-coated GSS and Inner skin 0.6mm Plain Al) with 40mm thick PUF panels, Floor Mounted with Mixing box, Filter section with Pre Filter, Fine Filter & HEPA Filter, Coil section with 6 row deep CHW cooling coil, Fan section with direct driven type backward curved plug fans with IE-2 motor & VFD, UV lamp and all other accessories complete. <br>AHU 5.5 TR, 2200 CFM & 500 Pa (Approx.) ESP

2

-

-

... More
od290299/2019_2020 : <br>AIR HANDLING UNITS FOR EXISTING CHILLER :-Supply, Installation, Testing, Commissioning and Validation of Air Handling units. Air Handling Unit shall be Double Skinned (Outer skin - 0.6mm pre-coated GSS and Inner skin 0.6mm Plain Al) with 40mm thick PUF panels, Floor Mounted with Mixing box, Filter section with Pre Filter, Fine Filter & HEPA Filter, Coil section with 6 row deep CHW cooling coil, Fan section with direct driven type backward curved plug fans with IE-2 motor & VFD, UV lamp and all other accessories complete. <br>AHU 5.5 TR, 2700 CFM & 500 Pa (Approx.) ESP

1

-

-

... More
od290282/2019_2020 : Chilled Water Manifold size suitable to AHU includes 2 Nos. Butterfly / Ball Valves, 1 No. Balancing valve, 1 No. Y-strainer, 1 No. 2 Way Valve with thermostat (with interconnected wiring between thermostat & mixing valve), 2 Nos. dial type Pressure gauges, 2 Nos. temperature Gauges, 1 No drain valve with MS 'C' class 6 m pipe for interconnection with insulation. <br>

4

-

-

... More
od290100/2019_2020 : Supply, Insulation, testing and commissioning of Fresh Air Louvere with bird screen<br>

2

-

-

... More
od290052/2019_2020 : "Supply, Installation, Testing and commissioning of Drain Water Piping P.V.C with nitrile insulation complete with fittings.<br>suitable size as per number of units connected<br>40mm"<br>

20

-

-

... More
16.3.11 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.br Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 50mm dia. (50mm thick expanded polysterene)

20

-

-

... More
16.12.2.1 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick

20

-

-

... More
16.12.2.2 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick

50

-

-

... More
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper

2

-

-

... More
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

6

-

-

... More
od140739/2021_2022 : DSOR 2018 Item 16.16<br>Supplying & Fixing of powder coated extruded aluminium Return Air Grilles with louvers but without volume control dampers complete as required<br>

6

-

-

... More
16.23.2 : INSULATION ON EXISTING PIPE br 16.4 Supplying, laying/ fixing, testing and commissioning of following thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on existing pipe and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required.Nitrille rubber insulation - 25 mm

60

-

-

... More
LEVEL - 6 ( C WING)

-

-

-

... More
od290305/2019_2020 : Dismantling and unloading of PAC and Outdoor units<br>

1

-

-

... More
od290306/2019_2020 : "Supply and fixing of INDOOR UNITS - cordless remote and all refnet joints. Air Handling Unit DOUBLE SKINNED Floor Mounted AHU with fine filter and pre filter, UV Lamp<br>(ICU ) ( VRF AHU 6F - 13)<br>22 TR, 8800 CFM, 250 CFM FA, 50mmESP "

1

-

-

... More
od290171/2019_2020 : Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping complete with fittings, with suitable adjustable hanger supports, jointing/brazing including accessories, insulated with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required <br>

20

-

-

... More
od290100/2019_2020 : Supply, Insulation, testing and commissioning of Fresh Air Louvere with bird screen<br>

0.5

-

-

... More
od290088/2019_2020 : "DUCT ACCOUSTIC INSULATION:-<br>Supply, Installation, Testing and commissioning of Open cell Nitrile rubber thermal insulation with 25mm thickness, 150 kg/m3 Density"<br>

10

-

-

... More
od290050/2019_2020 : Supply, Installation, Testing commissioning of AHU Kit and communication Kit between AHU and VRF ODU<br>

2

-

-

... More
od290052/2019_2020 : "Supply, Installation, Testing and commissioning of Drain Water Piping P.V.C with nitrile insulation complete with fittings.<br>suitable size as per number of units connected<br>40mm"<br>

5

-

-

... More
od290053/2019_2020 : "Control Cabling<br>Supply, Installation, Testing and commissioning of Control cabling with saddles / supports to connect outdoor units with respective indoor units"

30

-

-

... More
od28785/2021_2022 : Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units <br>suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules,<br>microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant,vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required<br>28 HP Outdoor Unit

1

-

-

... More
16.12.2.1 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick

5

-

-

... More
16.12.2.2 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick

10

-

-

... More
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper

0.5

-

-

... More
16.23.2 : INSULATION ON EXISTING PIPE br 16.4 Supplying, laying/ fixing, testing and commissioning of following thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on existing pipe and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required.Nitrille rubber insulation - 25 mm

10

-

-

... More
TOP ROOFING

-

-

-

... More
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

7854.93

-

-

... More
12.4.1 : Providing ridges or hips width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.0.80 mm thick with zinc coating not less than 275 gm/m2

826

-

-

... More
12.7.1 : Providing and fixing 15cm wide, 45 cm overall semi circular plain G.S. sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m2

832

-

-

... More
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

50325

-

-

... More
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

3065

-

-

... More
Plastering

-

-

-

... More
26.28.2 : Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge50mm average thickness

2000

-

-

... More
26.29.1 : Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars upto 12 mm diameter

1000

-

-

... More
26.29.2 : Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars above 12 mm diameter

500

-

-

... More
26.31.1 : Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.SBR Polymer (@10% of cement weight) modified cementitious bond coat @2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer

2000

-

-

... More
26.31.2 : Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make

300

-

-

... More
26.32.1 : Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).12 mm average thickness.

1000

-

-

... More
26.32.2 : Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).25 mm average thickness in 2 layers.

700

-

-

... More
26.32.3 : Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).50 mm average thickness in 3 layers.

300

-

-

... More
Lift Changing

-

-

-

... More
od289566/2019_2020 : Supply and Installation of 20 pax,1 mps new lift under the existing lift wells

3

-

-

... More
od289593/2019_2020 : Replacement of existing lift no. 13027 in Dental College

1

-

-

... More
od289594/2019_2020 : Replacement of existing old Lift No. 13028 in Dental College

1

-

-

... More
od291268/2019_2020 : Dismantling of existing lift of 20 or 15 People Capacity<br>

1

-

-

... More
5.16 : Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

200

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

4

-

-

... More
90.12.7.41 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

100

-

-

... More
od10206/2020_2021 : Replacement of existing old Lift No. 13029 in Hospital Building

1

-

-

... More
od10208/2020_2021 : Replacement of existing old Lift No. 13030 in Hospital Building

1

-

-

... More
od10209/2020_2021 : Replacement of existing old Lift No. 13035 in Hospital Building

1

-

-

... More
od10211/2020_2021 : Replacement of existing old Lift No. 13036 in Hospital Building

1

-

-

... More
Dumb Waiter

-

-

-

... More
od289731/2019_2020 : Supplying and Installation of Dumb-waiter

1

-

-

... More
DG Set

-

-

-

... More
od289161/2019_2020 : Supply, Fabrication, erection, testing and commissioning panel boards of free standing, floor mounting, fabricated out of 16SWG CRCA sheet cubicle type compartmentalized board suitable for operation on 440V, 3 phase, 50Hz, vermin proof, dust proof with the following mounting complete as per specifications. The design should be as per the IS standards.<br>GSB with ATS: Incomer for GSB- 1600A 4 pole Isolator. Outgoings: 1000A 4P Automatic Transfer Switch (ATS)-4 Nos, 630A 4P ATS-6 Nos, LED indication Lamps, Multifunction meters (Panel Mount) with Voltage and current indication, 1600A Aluminium Busbar, 25x3mm Copper Earthing and 1500A Bus duct.

1

-

-

... More
od289163/2019_2020 : Labour charges for Erection testing and commission of 500 KVA DG set

2

-

-

... More
od289166/2019_2020 : Supply & providing plate earth station with 1200 x 1200 mm G.I. plate earth electrode, water pipe, earthing strips, clamps, funnel, terminal electrodes etc., filling with alternate layers of charcoal and salt and back filling/ Earthing compound.The Earthing Station should confirm to IS 3043/1987. (Civil works not included)

6

-

-

... More
od289239/2019_2020 : Supply & Laying, clamping at site of copper earthing conductors inclusive of providing earthing terminations and bracing of the terminations etc.

1

-

-

... More
od289255/2019_2020 : Cable Laying Work: Supply, Laying, testing and commissioning of the following PVC /XLPE Insulated Armoured Aluminum L.T. Cables(AYWY/AYFY) through excavated trenches including supply and fixing of clamps, nuts and bolts, screws, identification tags etc. required for clamping intervals as necessary (all civil work/ cable trays not included)

1

-

-

... More
9.1.31 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)

48

-

-

... More
9.1.30 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)

4

-

-

... More
9.1.29 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)

12

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

2

-

-

... More
od289266/2019_2020 : Supply and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 kV grade as required (25 mm)<br>12c 2.5 Sq. mm Cu cable

1

-

-

... More
od289271/2019_2020 : Supply of Electrical ISI garde Rubber mat suitable for 440Volts switch boards( 6'x3'x1/2').

10

-

-

... More
od289274/2019_2020 : Supply and fixing 25x3 mm tinned copper earth bus

5

-

-

... More
1.1.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

10

-

-

... More
od289281/2019_2020 : Supply and laying 2.5 Sq. mm copper wire through 20mm PVC conduit for circuit mains

50

-

-

... More
od289289/2019_2020 : Supply and fixing 6x10 sintex junction box with connector

2

-

-

... More
od289293/2019_2020 : DG Syn panel:<br>INCOMER - 2Nos, 3 Pole, 800 A, Electrically operated Draw out type Air Circuit Breaker with Over Load & short Circuit release.<br>120 A Neutral Isolating Contactor with 1NO + 1NC Aux. contacts (2 nos)<br>Meters: Multi Data Meter, Flush Mounting,96Sq.mm reads the following parameters: Voltage LN per phase, Volts LL per phase, Volts LN Avg, Volts LL Avg, Amps per phase, Amps Avg, Amps phase angle per phase.<br>Frequency, Real power per phase & total, Reactive power per phase & total, Power factor per phase & average, Active energy import/export, Reactive energy (inductive/capacitive), Apparent Energy (2 nos).<br>Kilo-Watt Hour Meter, Flush Mounting, 96-mm2, 3 Phase 4 wire, Amps:5A, Volts; 415V AC (2 nos)<br>CT; Resin Cast Ring type Curent Transformer, CL-1 for Metering (6 nos)<br>Resin Cast Ring type Curent Transformer, CL-1 for EASY GEN (6 nos)<br>Switches:<br>Current Transformer (2 nos); <br>CT Mode Selector Switch with Auto/Manual/Test selection, 3pole, 3 Way With OFF 16A Rating (2 nos)<br>1Pole ON/OFF Sel Sw(Auto Load Start/Stop) ,16A Rating. (2 nos)<br>DP MCB, 16A (2 nos)<br>Indicating lamps (18 sets):IL1 - Set running - Green, 240V AC, IL2 - Load on set - Red, 240V AC, IL3 - Load ON Mains - Red, 240V AC , IL4 - DC ON - Red ,IL5 - Engine Fault - Amber, 240V AC,IL7 - Breaker ON - Red ,IL7 - Breaker OFF - Green , IL8 - NIC ON - Green , IL9 - NIC OFF – Red<br>Push Buttons (20 sets):PB1 - Engine start Man/Test - Green , PB2 - Engine stop man/Test - Red <br>PB3 - acknowledge -Black ,PB4 - Fault Reset - Yellow ,PB5 - Alt.Breaker Close - Green, PB6- Alt. Breaker Trip - Red , PB7 - Voltage Raise - Green , PB8 - Voltage Lower - Red ,PB9 - Speed Raise - Green ,PB10 - Speed Lower – Red<br>Timers:<br>2 C/O Electronic On Delay Timer with Source Voltage 240 Volts AC (2 nos)<br>1 C/O Electronic On Delay Timer with Source Voltage 24 Volts DC (2 nos)<br>Battery Charger unit (2 sets) with input 240V AC/ output 24V DC, <br>DC ammeter & voltmeter<br>Auxiliary contacts with coil voltage 240V and 24 V<br>AC Line voltage monitor<br>Hooter<br>EEFR<br>Al. bus bar<br>Auto/Manual syn, Auto load sharing and Momentary grid syn panel with:<br>Double Voltmeter, Flush Mounting , 144sq.Mm<br>Double Frequency Meter, Flush Mounting , 144sq.Mm <br>Synchronoscope ,Flush Mounting<br>Alternator Selector Switch, 16Amps Rating<br>EASY GEN For Auto Synchronising & Auto Load Sharing<br>Outgoing:<br>Triple Pole, 1600A, Electrically operated Draw out type Air Circuit Breaker with Over Load & short Circuit release <br><br> <br>

1

-

-

... More
od289316/2019_2020 : Supply and Installation testing and commissioning of 415V, 500kVA DG- Prime Power limited(3B) (Stand-by with variable load, loading :< 75%, No. of operating hours : Max. Continous / year, 10% overload capability) Duty as per specifications, with radiator cooled engine. The suitable rating breaker to be mounted on alternator box for local isolation.

2

-

-

... More
od289330/2019_2020 : Supply and Installation of 500kVA-DG, Fuel Piping, Class B M.S. Pipe duly painted of suitable size for fuel pumping between Day Tank and engine, Quoted rate shall include necessary hardware collars, bends adopters, brass fittings etc.

50

-

-

... More
od289358/2019_2020 : Supply and Installation of Thermal insulation for 250mm dia pipes

100

-

-

... More
od289359/2019_2020 : Supply and Installation of Exhaust pipe 8" suitable for 500kVA-DG,

100

-

-

... More
od289361/2019_2020 : Supply and Installation of Sound attenuator on top of the exhaust pipe to reduce the exhaust noise

30

-

-

... More
od289362/2019_2020 : Supply and Installation of Rain protection fins for the Sound attenuators

15

-

-

... More
od289363/2019_2020 : Supply and Installation of Conventional type lightning arrest or with 2x25x3mm GI down conductors & 230V aviation lamps for exhaust support structure. The lamp shall be wired up to the exhaust support at ground level with outdoor class JB. The lightning down conductors shall be brought down & connected to merest earth grid.

1

-

-

... More
od289364/2019_2020 : Supply and Installation of GI Steel items for supporting the exhaust pipes. These items shall be used for exhaust pipe supporting, silencer supporting etc.

5000

-

-

... More
od289365/2019_2020 : Supply and Installation of Aviation Lamp

1

-

-

... More
DG Civil and Truss works

-

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

48.2

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

46.4

-

-

... More
4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

20.4

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

1377

-

-

... More
9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc

2880

-

-

... More
50.6.1.1 : Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

12

-

-

... More
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

9

-

-

... More
2.27 : Supplying and filling in plinth with Jamuna sand under floors, including watering, ramming consolidating and dressing complete.

5.63

-

-

... More
13.6.1 : 20 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)

61.6

-

-

... More
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

3000

-

-

... More
12.5.1 : Providing valleys of 90 cm wide overall in plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limper and bitumen washers complete:1.60 mm thick with zinc coating not less than 350 gm/ m2

137.6

-

-

... More
DG Foundation - Piping work for Cables

-

-

-

... More
14.13.4 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required150 mm dia

56

-

-

... More
Supply and installation of CCTV

-

-

-

... More
od254151/2019_2020 : 4 MP 3.6 MM Lens 2688 X 1520 with junction box

80

-

-

... More
od254172/2019_2020 : 4 MP IP PTZ Camera 30 X Zoom, 150 Meter IR Distance

1

-

-

... More
od254179/2019_2020 : 16 Port POE switch with installation

2

-

-

... More
od254184/2019_2020 : 08 Port POE switch with installation

16

-

-

... More
od254188/2019_2020 : 32 Channel NVR with 2 HDD Port 200 Mbps

4

-

-

... More
od254190/2019_2020 : Hard Disk - Internal- 6 TB - WD

8

-

-

... More
od254192/2019_2020 : Optilink Optical Multiport - OLT

1

-

-

... More
od254195/2019_2020 : Optilink - Optical Network Converter - ONU

18

-

-

... More
od254201/2019_2020 : LG 43 Inch Full HD TV with Wall Mount Stand,Tvmounting bracket<br>and Installation Charges

4

-

-

... More
od254208/2019_2020 : Dlink/ Unicorn 4 U Network rack with Power strip and cable tracker<br>and mounting

17

-

-

... More
od254209/2019_2020 : Inverter 3 KV, 150 AH Battery 4 nos- Luminous

1

-

-

... More
od254212/2019_2020 : Dlink/ Unicorn 17 Network rack , Trolly with Power strip and cable<br>tracker and mounting

1

-

-

... More
od254221/2019_2020 : HDMI Cable 4K 10 meters

4

-

-

... More
od254223/2019_2020 : Wireless mouse - Logitech

4

-

-

... More
od254543/2019_2020 : Dlink CAT 6 LAN Cable - UTP

6500

-

-

... More
od254259/2019_2020 : Fiber optic coupler

30

-

-

... More
od254264/2019_2020 : Fiber optic patch code

30

-

-

... More
od254291/2019_2020 : Optical fibre cable 6 F with stay wire

1400

-

-

... More
od254293/2019_2020 : 2.5 mm 3 Core ISI UG Cable for power distribution to Hub at all floor including cabling charges

750

-

-

... More
od254296/2019_2020 : Camera Installation & Testing

80

-

-

... More
od254302/2019_2020 : Fiber optic cable splicing charges

80

-

-

... More
od254305/2019_2020 : <br>20 MM ISI Evershine conduit can fittings and cabling accessories for CAT 6 and OFC Cabling charges with labour charge

2650

-

-

... More
2 Appendix- B Rising of RCC man hole cover,Drainage,Retaining wall and Foot path work

-

-

-

... More
15.48 : Taking out C.I cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually / by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials with 50 metres lead as per direction of Engineer -in- Charge.

8

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

763.65

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

92.4

-

-

... More
4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

160.55

-

-

... More
19.35.2 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.600 mm dia RCC pipes.

30

-

-

... More
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

66.23

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

865.68

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

2283.18

-

-

... More
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide

1130

-

-

... More
5.22.1 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars

3853

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

758

-

-

... More
16.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)

89.1

-

-

... More
16.68 : Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

1470

-

-

... More
11.20.3 : Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Dark shade pigment using ordinary cement

1050

-

-

... More
od254840/2019_2020 : Providing and fixing PVC pipes including jointing of pipes with one step PVC solvent cement , trenching, refilling for drain pipe etc complete as per the direction of Engineer in Charge. 150mm PVC pipe(6 kg/cm2)<br>

90

-

-

... More
od255065/2019_2020 : Pavement on road surface using dry random rubble masonery including necessary earth work excavation as per the direction of Engineer-in-charge.

32

-

-

... More
10.26.3 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes

7500

-

-

... More
10.20 : Providing and fixing bolts including nuts and washers complete.

110

-

-

... More
13.9.1 : Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster

1214.41

-

-

... More
13.4.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)

1941

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

1941

-

-

... More
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

1941

-

-

... More
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

500

-

-

... More
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

318.23

-

-

... More
7.2.1 : Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like.Cement mortar 1:6 (1 cement : 6 coarse sand)

12.84

-

-

... More
16.79 : Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge.

147

-

-

... More
1 Appendix- A Surface improvement work of campus road around Hospital,Dental college and medical college blocks and BT patches

-

-

-

... More
3.15.2 : Compacting Original Groundbr (ii) Compacting original ground supporting subgradebr Loosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per Technical Specification Clause 303.5.2.

135

-

-

... More
3.2 : Preparation of Foundation for Embankment Scarifying Existing Bituminous Surface to a Depth of 150 mm by Mechanical Means Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4.

10385.1

-

-

... More
75.5.5.B.2pb : Modified Penetration Macadam 75 mm thick using Bitumen S-65 - Packed Bitumen Rates br Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506.,including supplying and stacking of materials.

683.17

-

-

... More
75.5.5.A.1pb : Modified Penetration Macadam 50 mm thick using Bitumen S-65 - Packed Bitumen Rates br Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506.,including supplying and stacking of materials.

746.61

-

-

... More
75.5.1.1pb : Prime Coat - Low porosity - With Packed Bitumen Rates br Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502

781.5

-

-

... More
75.5.2.3pb : Tack Coat - With Packed Bitumen Rates br Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.

17483.94

-

-

... More
75.5.2.1pb : Tack Coat - With Packed Bitumen Rates br Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.

11010.44

-

-

... More
75.5.9.1.2pb : 20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder - Bitumen S-65 - Packed Bitumen Ratesbr Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. br Case - I By Manual Means br (II) Bitumen (S-65),including supplying and stacking of materials.

6331

-

-

... More
75.5.12.A.3.2pb : Seal Coat - Manual Means - Type C - Bitumen S-65 - Packed Bitumen Rates br Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 br A. By Manual Means br Case III : Type C br (II) Bitumen (S-65),including supplying and stacking of materials.

6331

-

-

... More
3.14 : Construction of Subgrade and Earthen Shouldersbr Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.

360

-

-

... More
1 Appendix- B Surface improvement work of campus road around Hospital,Dental college and medical college blocks and BT patches (items as per MortH Roads)

-

-

-

... More
4.2.A.2 : Construction of granular sub-base by providing graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401. br Grading-IV - For lower sub base - Mix in Place Method br

76.5

-

-

... More
4.12 : Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.

116.24

-

-

... More
5.3.2.a : Providing and laying bituminous macadam with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading premixed with bituminous binder (VG 30), transported to site, laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction.br For Grading II - (19 mm nominal size)br

596.11

-

-

... More
5.6.2.a : Providing and laying bituminous concrete with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder( NRMB) @ 5.4 per cent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects Grading - II (13.2 mm Nominal Size)br

345.24

-

-

... More
8.13 : Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads on Bituminous Surface @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.

417.14

-

-

... More
8.35 : Providing and fixing reflective road studs (Raised Pavement Marker) of ' category A' made out of ASA/HIPS/ABS moulded body with shanks and conforming to ASTM D 4280, strong enough to support a load of more than 13.635 T when tested in accordance with ASTM D 4280, reflective panel confirming to ASTM D 788, and reflectivity conforming to clause 804.4. including installation, drilling, fixing with adhesive etc. with 2 years warranty for the road stud as well as for in field performance as per clause 804.7.3 Road Markers/Road Stud with Lense Reflector :-

500

-

-

... More
Parking

-

-

-

... More
2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

1080

-

-

... More
2.9.1 : Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock

720

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

19.2

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

240

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

1152

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

21504

-

-

... More
16.68 : Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

7200

-

-

... More
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level

268.8

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.