WAPCOS Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

WAPCOS Limited - WAPCOS Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date7 Oct 2024
Closing Date4 Jan 2025
Tender Amount₹ 35,10,71,836 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

146.7

-

-

... More
2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

36.53

-

-

... More
od48631/2022_2023 : Boring, providing and installation bored cast-in-situ reinforced cement concrete piles<br>of grade M-30 of specified diameter and length below pile cap, to carry a safe working load not less than<br>specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution<br>and temporary casing of appropriate length for setting out and removal of same and the length of the pile to<br>be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete,<br>including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured<br>up to bottom of pile cap). Note: Truck Mounted rotary/TMR/Tube well boring machine shall not be<br>used.<br>700 mm dia piles<br>Details of cost for 15 m length of pile<br>MATERIAL:<br>Concrete 3.14/4x0.75²x15 =6.62cum

384

-

-

... More
od48632/2022_2023 : :Boring, providing and installation bored cast-in-situ reinforced cement concrete piles<br>of grade M-30 of specified diameter and length below pile cap, to carry a safe working load not less than<br>specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution<br>and temporary casing of appropriate length for setting out and removal of same and the length of the pile to<br>be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete,<br>including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured<br>up to bottom of pile cap). Note: Truck Mounted rotary/TMR/Tube well boring machine shall not be<br>used.<br>800 mm dia piles

720

-

-

... More
od48633/2022_2023 : Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below pile cap, to carry a safe working load not less than<br>specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution<br>and temporary casing of appropriate length for setting out and removal of same and the length of the pile to<br>be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete,<br>including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured<br>up to bottom of pile cap). Note: Truck Mounted rotary/TMR/Tube well boring machine shall not be<br>used.<br>900 mm dia piles<br>Details of cost for 10 m length of pile<br>MATERIAL:<br>Concrete 3.14/4x1.00x10 = 7.85 cum

204

-

-

... More
20.6.2.1 : Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile above 50 tonne and upto 100 tonne capacityInitial test

4

-

-

... More
20.6.2.2 : Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile above 50 tonne and upto 100 tonne capacityRoutine test

4

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

327.18

-

-

... More
od35730/2022_2023 : Extra for additional bed upto 1Km or initial lead of 50M for disposing of surplus excavated earth as per the direction of the engineer in charge

576.62

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

249.02

-

-

... More
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level

640.69

-

-

... More
5.34.1 : Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).

640.69

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

1139.06

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

973.48

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

81.06

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

147693.7

-

-

... More
4.11 : Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).

292.04

-

-

... More
od51749/2022_2023 : Solid block masonry using pre cast Fly ash solid blocks (Factory made with a<br>minimum fly ash composition of 40%) of size 40x20x20cm or nearest available size confirming to IS 2185<br>Part I of 1979 for super structure above floor two level up to floor V level thickness 20cm and above in: CM<br>1:6 ( 1 cement :6 coarse sand) etc complete

77.88

-

-

... More
od35739/2022_2023 : Supplying and filling with quarry dust under slabs, including watering,<br>ramming consolidating and<br>dressing complete.

174.68

-

-

... More
Super structure

-

-

-

... More
5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level

2383.32

-

-

... More
5.34.1 : Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).

2424.67

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

6207.47

-

-

... More
5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

873.05

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

1045.36

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

6593.92

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

3127.22

-

-

... More
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

297.46

-

-

... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

357183.15

-

-

... More
od48683/2022_2023 : Providing expansion joints on the roof by synthetic rubber water bar embedded in the<br>expansion gap and insulating the surface with a coat of bitumen after forming a small hump profile over the<br>joint by using 1:3 braced RCC cement plaster, providing flat first layer of bitumen felt of crown piece seal<br>over the lap joints fixing with a layer of bitumen felt extending over the hump crown and finishing along the<br>cemented surface of the two slabs, so as to continuously take any finishing work etc. complete to<br>specification.

33.64

-

-

... More
od48684/2022_2023 : Providing 15cm wide strips bitumen based mineral fibre pad conforming to IS 1838, so<br>as to totally seal any gaps between the two joints/expansion gap before finishing plastering work and<br>flooring etc. complete to specification

168.2

-

-

... More
od36154/2022_2023 : Solid block masonry using pre cast Fly ash solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.

75.75

-

-

... More
od43516/2022_2023 : Solid block masonry using pre cast Fly ash solid blocks (Factory made with a<br>minimum fly ash composition of 40%) of size 40x20x20cm or nearest available size confirming to IS 2185<br>Part I of 1979 for super structure above floor two level up to floor V level thickness 20cm and above in: CM<br>1:6 ( 1 cement :6 coarse sand) etc complete

239.46

-

-

... More
od36155/2022_2023 : Solid block masonry using pre cast Fly ash solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

118.92

-

-

... More
od43523/2022_2023 : Solid block masonry using pre cast Fly ash solid blocks (Factory made with a<br>minimum fly ash composition of 40%) of size 40x20x10 cm or nearest available size confirming to IS 2185<br>part I of 1979 for super structure from floor two level to floor five level for 10 cm thick wall in : CM 1:6 ( 1<br>cement : 6 coarse sand) including cost of scaffolding complete

90.38

-

-

... More
6.47 : Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).

1179.99

-

-

... More
Finishing works

-

-

-

... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

13215.92

-

-

... More
13.2.1 : 15 mm cement plaster on the rough side of single or half brick wall of mix:1:4 (1 cement :4 fine sand)

1526.21

-

-

... More
13.22 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.

2338.55

-

-

... More
5.23 : Smooth finishing of the exposed surface of RCC work with 6mm thick cement mortar 1:3 ( cement : 3 fine sand).

12587.12

-

-

... More
13.7.2 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)

2277.13

-

-

... More
od38203/2024_2025 : Brick jelly concrete in cement concrete 1:3:6 using 40mm broken bricks including cost, labour charges etc complete<br>

38.49

-

-

... More
4.2.5 : Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size)

178.9

-

-

... More
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

3428.67

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

29768.89

-

-

... More
od41844/2022_2023 : Providing two coats of wall painting with premium acrylic emulsion paint of interior<br>grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and<br>manufacture, including applying additional coats wherever required to achieve even shade and colour

31740.17

-

-

... More
od41845/2022_2023 : Finishing walls with Acrylic Smooth exterior paint having VOC (Volatile Organic<br>Compound ) content less than 50 grams/ litre of required shade:New work (Two or more coat applied @ 1.67<br>ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

3666.19

-

-

... More
13.44.1 : Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)

857.46

-

-

... More
12.63 : Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittnce tested as per ASTM) C 1549 and ASTM C 1371 respectively), VOC less than 10 cc/gm. The coating thickness and the methodology of application shall strictly as per manufacture's specifications and as approved by engineer in charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc., washing with water all complete. The contractor shall give guarantee for the performance of SRI and also the durability of coating, all complete as per direction of Engineer - in- charge.

1880.18

-

-

... More
9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc

5734.58

-

-

... More
od43955/2022_2023 : Painting with synthetic enamel paint having VOC (Volatile Organic Compound) content<br>less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever<br>required to achieve even shade and colour.

981.47

-

-

... More
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

4065.8

-

-

... More
11.20.3 : Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Dark shade pigment using ordinary cement

406.46

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

6129.69

-

-

... More
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

919.45

-

-

... More
od41928/2022_2023 : Providing and laying anti skid vitrified tiles of size 600x600 mm or more (thickness to<br>be specified by the manufacturer) of Ist quality conforming to IS: 15622 of approved make in all colours,<br>shades, except white, Ivory, Grey Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4<br>Coarse sand) including grouting the joints with epoxy grouting and matching pigments etc., complete.

384.75

-

-

... More
od42000/2022_2023 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

983.92

-

-

... More
8.2.2.1 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shadeArea of slab upto 0.50 sqm

419.53

-

-

... More
8.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

7.66

-

-

... More
8.9.1.2 : Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete.Granite of any colour and shade

531.75

-

-

... More
od44607/2022_2023 : Providing and laying FRP lining water proofing treatment in sunken portion of WC's<br>bathroom etc. as per specification. The application shall be done only after cleaning of surface, there after<br>applying powder with resin, compound, then laying of FRP lining (fibre glass lamination) by applying resin<br>with blue pigment etc. as per manufactures specification. Application of first coat resin with chalk powder on<br>the corner, uneven surface and undulation and laying the o Fibre glass lamination with resin and blue<br>pigment, o Surfase mat lamination with resin. The second coat application shall be done with applying resin with Paraffin wax, chalk powder and blue pigment etc. complete. The rate includes preparation of surface,<br>pressure grouting over slab & side wall, treatment and sealing of all joints, corners, junctions of pipes and<br>masonry with polymer mixed slurry and testing of applied area complete.<br>

384.75

-

-

... More
od44608/2022_2023 : :Providing and laying FRP lining water proofing treatment in terrace & sunshades as<br>per specification. The application shall be done only after cleaning of surface, there after applying powder<br>with resin, compound, then laying of FRP lining (fibre glass lamination) by applying resin with blue pigment<br>etc. as per manufactures specification. Application of first coat resin with chalk powder on the corner,<br>uneven surface and undulation and laying the o Fibre glass lamination with resin and blue pigment, o<br>Surfase mat lamination with resin. The second coat application shall be done with applying resin with<br>Paraffin wax, chalk powder and blue pigment etc. complete. The rate includes preparation of surface,pressure grouting over slab & side wall, treatment and sealing of all joints, corners, junctions of pipes and<br>masonry with polymer mixed slurry and testing of applied area complete.<br>

1880.18

-

-

... More
od44609/2022_2023 : Providing and laying FRP lining water proofing treatment in shear walls as per<br>specification. The application shall be done only after cleaning of surface, there after applying powder with<br>resin, compound, then laying of FRP lining (fiber glass lamination) by applying resin with blue pigment etc.as per manufactures specification. Application of first coat resin with chalk powder on the corner, uneven<br>surface and undulation and laying the o Fiber glass lamination with resin and blue pigment, o Surface mat<br>lamination with resin. The second coat application shall be done with applying resin with Paraffin wax, chalk<br>powder and blue pigment etc. complete. The rate includes preparation of surface, pressure grouting over<br>slab & side wall, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer<br>mixed slurry and testing of applied area complete.

81.06

-

-

... More
od46194/2022_2023 : Providing and laying FRP lining water proofing treatment in water tank as per<br>specification. The application shall be done only after cleaning of surface, there after applying powder with<br>resin, compound, then laying of FRP lining (fibre glass lamination) by applying resin with blue pigment etc.<br>as per manufactures specification. Application of first coat resin with chalk powder on the corner, uneven<br>surface and undulation and laying the o Fibre glass lamination with resin and blue pigment, o Surfase mat<br>lamination with resin. The second coat application shall be done with applying resin with Paraffin wax, chalk<br>powder and blue pigment etc. complete. The rate includes preparation of surface, pressure grouting over<br>slab & side wall, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer<br>mixed slurry and testing of applied area complete

240.9

-

-

... More
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

1287.05

-

-

... More
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

1076.39

-

-

... More
9.1.2 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Sal wood

5.8

-

-

... More
9.21.1 : Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non- decorative Type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

248.16

-

-

... More
9.53 : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

678

-

-

... More
9.74.1 : Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm

226

-

-

... More
9.76 : Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

113

-

-

... More
9.82 : Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.

226

-

-

... More
od59792/2022_2023 : Supplying and fixing Non-Hermetically Sealed Manual Double Leaf Swing Door of<br>Antimicrobial HPL finish Nik229 swing door of 44 mm thick with 45±2 kg/m3 density PUF insulated. Anodized<br>aluminum alloy door profile. Wall frame 80 mm x 60 mm, 2.5 mm thick Al 6063 anodized with 2mm GI<br>reinforced. Including providing double glazed vision panel with 4 mm clear glass (300 mm x 300 mm x 44 mm<br>or above size as directed by Architect), euro norm cylinder lock with outside key and inside emergency<br>release, both side SS D-handle , SS ball bearing hinges , door closure push and hold for active leaf ,<br>providing concealed drp seal, rubber gasket for air tightness, concealed/open Stainless steel Tower bolts of<br>250 & 150mm, Stainless steel door stopper etc. complete in all respect as directed by Engineer in charge. No<br>Organic material (No Decay and No Contamination) for all main doors.

136.41

-

-

... More
od60239/2022_2023 : Supplying and fixing non Hermetically sealed single leaf manual sliding door of<br>Antimicrobial HPL Seam Less finish, Nik229 with lever handle both side for manual opening, Door profile<br>made of Aluminium Alloy Grade 6063 Temper T6.Natural Anodised 20 m as per EN ISO 2360. Component<br>Polyurethane Rigid CFC Free, Blowing Agent: Water. Dimensional stability at +100°C & -25°C (2%max) as per<br>DIN53431. Density 45Kg/M3 with max deviation of 2kg/m3 as per DIN53420. Condensation resistance at 38°C<br>and 88RH > Max variation 2% in Weight and volume. Lever Handle Solid AISI 304 Grade Stainless Steel,Rubber spring system. Roller Material PA6G 210 (Self-lubricating) PA Bearings 2X per roller. Rail Aluminium<br>Alloy, Grade 6063, Temper T6. Photo cell fitted across the door opening inside the wall frame. Double glazed<br>IG unit with 5 mm tempered glass of size 300 mm x 300 mm x 60mm, flush finished."

15.18

-

-

... More
od59796/2022_2023 : Providing and fixing 30mm thick factory made single extruded WPC {Wood Polymer<br>Composite) solid decorative type panelled/flush door shutter of required size comprising of virgin polymer of<br>K value 58-60 {Suspension Grade), calcium carbonate and natural fibers {wood powder/ rice husk/wheat<br>husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650<br>kg/cum and screw withdrawa l strength of 1800 N (Face) & 900 N {Edge), minimum compressive strength<br>50N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with<br>property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC<br>foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter<br>and fix ing with stainless steel butt hinges of required size with necessary full body threaded star headed<br>counter sunk 5.5 screws, all as per direction of Engineer-In- Charge. {Note: stainless steel butt hinges and<br>necessary 5.5 screws shall be paid separately) for toilet door.<br>

126.72

-

-

... More
od59797/2022_2023 : Providing and fixing factory made single extruded WPC (Wood Polymer Composite)<br>solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K<br>value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk)<br>and non toxic addit ives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after<br>applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum<br>frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of<br>Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed<br>in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of<br>Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately

300

-

-

... More
od62002/2022_2023 : Providing and fixing Aluminum composite panel 4mm thick for aluminum doors<br>with<br>necessary screws, beedings etc complete

100.08

-

-

... More
od74323/2022_2023 : Providing and fixing in position CNC wall panelling on exterior wall .The wall has to be finished as per architectural specification. Cost including all labour charges for making ,loading unloading in site. and fixing at proper places with scaffoldings if necessary.

35.52

-

-

... More
12.52.1 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending

1803.71

-

-

... More
12.52.2 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in perforated Tegular global white color tiles of size 595x595 mm and 0.5mm thick with 8 mm drop; made of GI sheet having glavanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyster powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.

605.38

-

-

... More
26.26.1 : Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.With semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles.

137.07

-

-

... More
26.26.2 : Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.With fully perforated 12 mm thick micro tegular edged or 10 mm thick square edged GRG false ceiling tiles.

339.74

-

-

... More
od75150/2022_2023 : Providing and fixing false ceiling 250 mm x 6 mm thick multi chamber hollow PVC panel .The support from ceiling is to be provided using 25 mm x 25 mm size aluminum square tube pipe at a distance of 2 ft (Framing work) with complete fitting etc complete as per specification.<br>

421.14

-

-

... More
9.105.3 : Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with Zinc coating of 120 gms/ (both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete.66 mm overall thickness Partition with 8 mm thick double skin Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process with Compressive Strength 225 kg/sq cm, Bending Strength 100 kg/sq cm

101.49

-

-

... More
21.13 : Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete

218

-

-

... More
14.34 : Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete

272

-

-

... More
9.71.2 : Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete:100x60x2.50 mm

872

-

-

... More
9.74.3 : Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:150x10 mm

544

-

-

... More
21.16.2 : Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-Charge.Powder coated minimum thickness 50 micron aluminium

544

-

-

... More
10.6.1 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

9.9

-

-

... More
10.7 : Providing and fixing ball bearing for rolling shutters.

1

-

-

... More
10.8.1 : Extra for providing mechanical device chain and crank operation for operating rolling shuttersExceeding 10.00 sqm and upto 16.80 sqm in the area

7.2

-

-

... More
10.9 : Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).

1.8

-

-

... More
od45467/2022_2023 : Supply of vision panel in fire rated doors of 200 mm x 500 mm size made out<br>of<br>minimum 5 mm thick clear fire rated glass (imported) for 120 minutes fire rating of fully transparent<br>in<br>fire/non-fire conditions having minimum 93% transparency, in accordance with IS : 3614 Part -II and<br>BS : 476<br>Part 20& 22 , for 120 min. fire rating for stability and integrity and insulation criteria

5

-

-

... More
od45468/2022_2023 : Providing and fixing concealed fire rated 120 minutes RT door closer along<br>with<br>necessary SS screws, bolts, nuts, washers etc. as per approved samples complete as per the<br>direction of the<br>Engineer-in-charge.

5

-

-

... More
od45469/2022_2023 : Providing and fixing panic bar / latch (Single point) fitted with a single body,<br>Trim<br>Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by<br>the<br>Engineer- in- charge, all complete

5

-

-

... More
od45470/2022_2023 : Providing and fixing Door frame and Shutter made of 46mm thick steel fire check<br>door<br>of 120 minutes fire rating confirming to BS: 476 Part 22 and IS: 3614 Part II for stability and<br>integrity,<br>fabricated with 2 nos. 22 gauge thick galvanized steel sheet with infill of fire rated Acrylic<br>Sealant and noncombustible<br>core bonded to both faces of sheet with lock seam joints at stile edges and<br>internal<br>reinforcement at top, bottom and stile edges for Fire Rating. The door frames are manufactured<br>from 18<br>gauge thick galvanized steel sheet pressed from to single rebate profile of size 125mm x 75mm.<br>The frames<br>shall be fixed using canon/hilti anchor bolts of size 10mm dia x 100mm long. The door<br>frames and door<br>shutters are finished with powder coating paint. The cost includes providing and fixing<br>of minimum two-hour<br>fire rated stainless steel ball bearing hinges 125 mm x 75mm x 3mm. The cost<br>includes providing opening for<br>vision panel of required size in shutters (cost of glass excluded) and<br>fixing vision panels of specified size<br>with complete fire rated gasket channel & moulding beading and<br>filling the gap between moulding /beading<br>and glass with suitable sealant

15.84

-

-

... More
od84500/2022_2023 : Providing and making laying fire brick walls (Factory made) of size of fire retardant bricks 9''x4''x3'' or nearest available size laid in mortar of high alumina cement and fine aggregate of crushed fire brick 1:2 including cost of scaffolding for superstructures.

44.04

-

-

... More
21.18 : Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately)

151.82

-

-

... More
od45471/2022_2023 : Providing and fixing SS H handle of size 450mm with SS screws etc. complete as<br>per<br>direction of Engineer-in-Charge.

56.8

-

-

... More
od45472/2022_2023 : :Providing and fixing SS lock of size suitable for glass door with SS screws<br>etc.<br>complete as per direction of Engineer-in-Charge

33

-

-

... More
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

874.88

-

-

... More
12.51.2 : Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Flashings / Aprons (Upto 600 mm)

191.97

-

-

... More
50.12.2.5 : Providing & fixing Poly carbonate multi wall plain sheet 8 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling/ self tapping screw of size ( 5.5x55mm) with EPDM seal complete upto any pitch in horizontal /vertical / curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size and shapes where ever required.

208.11

-

-

... More
10.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes

12824.4

-

-

... More
25.1 : Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).

4275.04

-

-

... More
12.7.1 : Providing and fixing 15cm wide, 45 cm overall semi circular plain G.S. sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m2

199.58

-

-

... More
25.4 : Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge.

14.4

-

-

... More
25.2 : Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cumsmoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin- Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub-head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories 1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr” 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.” 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01-05 testing method for a range upto 2000 ml” 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm” 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml”

301.4

-

-

... More
od58324/2022_2023 : Providing and fixing Cubicle curtains in the wards suitable for beds laid. The rate includes all cost of cloth, curtain track, supports, hardware items, stitching charges and all labour charges including conveyance, loading unloading etc. complete in all respect. The length of curtain cloth should have 1metre more length than the channel length. The height of curtain should have 7.5feet or standard approved ht. payment shall be made only as per site measurements of works actually done. (Curtained track length only shall be measured for payment) for All multi bed areas (Recovery, ICU, General wards Palliative wards, Procedure rooms, etc)<br>

243.94

-

-

... More
od58501/2022_2023 : Providing, fitting fixing12mm thick toughened glass partition as per design. The partiton will be supported withS.S patch panel fittings of approved barnd as, The exposed edge of the glass partition should be polished to super quality , providing fixing arrangement and making necessary holes and fittings, including cost of all labour & material etc. complete as per direction of Engineer-in-charge . <br>

104.19

-

-

... More
od46228/2022_2023 : :Providing heavy duty FRP manhole cover and frame of size 75cmx75cm internal<br>dimension with load<br>bearing capcity of 2.5 tonne made of polyster resin , fibre glass and fillers of<br>approved quality fixing in<br>correct line and level as directed by Engineer-in-charge

6

-

-

... More
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

993.16

-

-

... More
od49084/2024_2025 : Providing and applying application of Transparent Glass Coating to Block Heat on the indoor side of 4 mm thick plain glass to achieve Visible Light Transmission (VLT)greater than or equal to 71% and Solar Heat Gain Coefficient (SHGC) less than or equal to 0.61 for external windows only as per the direction from Engineer-in -Charge

423.67

-

-

-

-

-

... More
od40565/2024_2025 : Supply of Green Cleaning Chemicals as per the direction of Engineer in charge (Note: Payment shall be be made as per the actual bills submitted and same shall be reimbursed)

1

-

-

... More
External works

-

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

1393

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

1202.68

-

-

... More
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

76.5

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

108.71

-

-

... More
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level

440.43

-

-

... More
5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level

38.15

-

-

... More
5.34.1 : Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).

478.58

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

50764.96

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

184.98

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

1347.43

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

991.33

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

122.92

-

-

... More
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

8.08

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

736.03

-

-

... More
19.32.1 : Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

4

-

-

... More
od62367/2022_2023 : :Solid block masonry using pre cast Fly Ash solid blocks (Factory made with a<br>minimum fly ash composition of 40%)) of size 40x20x20cm or nearest available size confirming to IS 2185<br>part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6<br>coarse sand) etc complete<br>Details of cost for one cum

70.94

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

2087.35

-

-

... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

390.62

-

-

... More
13.2.1 : 15 mm cement plaster on the rough side of single or half brick wall of mix:1:4 (1 cement :4 fine sand)

399.71

-

-

... More
od41275/2022_2023 : Providing two coats of wall painting with premium acrylic emulsion paint of interior<br>grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and<br>manufacture, including applying additional coats wherever required to achieve even shade and colour

1447.07

-

-

... More
od62259/2022_2023 : <br>Finishing walls with Acrylic Smooth exterior paint having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)<br>

48.54

-

-

... More
22.6 : Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured)

23.3

-

-

... More
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

79.58

-

-

... More
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

60.48

-

-

... More
21.2.2 : Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides

8.58

-

-

... More
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness

31.83

-

-

... More
10.6.1 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

21.6

-

-

... More
10.7 : Providing and fixing ball bearing for rolling shutters.

6

-

-

... More
10.8.1 : Extra for providing mechanical device chain and crank operation for operating rolling shuttersExceeding 10.00 sqm and upto 16.80 sqm in the area

21.6

-

-

... More
10.9 : Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).

5.4

-

-

... More
od41524/2022_2023 : :"Providing of good Quality Heavy Duty Wall Supported type ALUMINUM LADDER Made<br>from 10 SWG<br>Aluminum Alloy ""C"" Section size - 66 x 33 x 3.15 mm, Rung - 25.4 mm Fluted type fixing<br>correct line<br>and level as directed by Engineer-in-charge

96

-

-

... More
od41539/2022_2023 : :Providing heavy duty FRP manhole cover and frame of size 75cmx75cm internal<br>dimension with load<br>bearing capcity of 2.5 tonne made of polyster resin , fibre glass and fillers of<br>approved quality fixing in<br>correct line and level as directed by Engineer-in-charge

8

-

-

... More
od41540/2022_2023 : Providing and laying FRP lining water proofing treatment in water tank as per<br>specification. The application shall be done only after cleaning of surface, there after applying powder with<br>resin, compound, then laying of FRP lining (fibre glass lamination) by applying resin with blue pigment etc.<br>as per manufactures specification. Application of first coat resin with chalk powder on the corner, uneven<br>surface and undulation and laying the o Fibre glass lamination with resin and blue pigment, o Surfase mat<br>lamination with resin. The second coat application shall be done with applying resin with Paraffin wax, chalk<br>powder and blue pigment etc. complete. The rate includes preparation of surface, pressure grouting over<br>slab & side wall, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer<br>mixed slurry and testing of applied area complete

635.19

-

-

... More
16.71 : Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer - in- Charge.

173.6

-

-

... More
od56160/2022_2023 : Providing and laying 60 mm thick factory made cement concrete interlocking paver<br>block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size,<br>design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse<br>sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

387.95

-

-

... More
Formation of Bituminous road

-

-

-

... More
3.6 : Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m

908.63

-

-

... More
4.2.A.1 : Construction of granular sub-base by providing graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401. br Grading-III -For lower sub base - Mix in Place Methodbr

454.32

-

-

... More
4.12 : Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.

302.88

-

-

... More
5.1.a : Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means.

1514.39

-

-

... More
5.2.a : Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom.

1547.49

-

-

... More
5.3.2.a : Providing and laying bituminous macadam with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading premixed with bituminous binder (VG 30), transported to site, laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction.br For Grading II - (19 mm nominal size)br

82.64

-

-

... More
5.6.2.a : Providing and laying bituminous concrete with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder( NRMB) @ 5.4 per cent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects Grading - II (13.2 mm Nominal Size)br

38.12

-

-

... More
3.18 : Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2

17.26

-

-

... More
8.11.1 : Painting lines, dashes, arrows etc on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control Over 10 cm in width

319.49

-

-

... More
8.13 : Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads on Bituminous Surface @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.

47.92

-

-

... More
Development of Koyilandi Taluk Hospital - Landscape works

-

-

-

... More
od62052/2022_2023 : Taking pit size 0.75M x0.75M.x0.75M., fill it with earth and organic manure mixture and<br>supply and planting trees MIMUSPOS ELENGI

8

-

-

... More
od62053/2022_2023 : Taking pit size 0.75M x0.75M.x0.75M., fill it with earth and organic manure mixture and<br>supply and planting trees SARACA ASOCA

6

-

-

... More
od62074/2022_2023 : Taking pit size 0.3M x0.3M.x0.3M., fill it with earth and organic manure mixture and<br>supply and planting shrubs CROSSANDRA

45

-

-

... More
od62075/2022_2023 : Taking pit size 1M x1M.x1M., fill it with earth and organic manure mixture and supply<br>and planting tree ALSTONIA SCHOLARIS

25

-

-

... More
od62092/2022_2023 : Providing and fixing buffalo grass existing ground prepared with proper level and<br>ramming with required tools wooden (Dhurmos) and than rolling the surface with light roller make the<br>surface smoothen and even, watering with sprinkle

178.19

-

-

... More
od62097/2022_2023 : Supply and spreading good earth for landscaping including all cost of material and<br>labour charge etc complete

106.9

-

-

... More
Signages

-

-

-

... More
od56175/2022_2023 : Providing and fixing / holding sinages, sign board made of compact aluminium panel sheet or HPL sheet of approved shade , providing 3mm vinyl pased letters with multi language and logos of approved sizes, providing side hangers fixing in position,providing centre handers using Ms rods amn chains etc. displaying scope of services, room numbers, doctors rooms, HOD rooms, floor wise facilities ,radiation sinages, mandatory notification as directed by the engineer in charge with one side lettering for fixed in wall and both sides as in projected type etc. complete to detailed pre approved plan.<br>Scope fo services in all deptmt- 120x150cm .<br>

10

-

-

... More
od56645/2022_2023 : Providing and fixing / holding sinages, sign board made of compact aluminium panel sheet or HPL sheet of approved shade , providing 3mm vinyl pased letters with multi language and logos of approved sizes, providing side hangers fixing in position,providing centre handers using Ms rods amn chains etc. displaying scope of services, room numbers, doctors rooms, HOD rooms, floor wise facilities ,radiation sinages, mandatory notification as directed by the engineer in charge with one side lettering for fixed in wall and both sides as in projected type etc. complete to detailed pre approved plan.<br>Stair area 120x100cm<br>

5

-

-

... More
od56193/2022_2023 : Providing and fixing / holding sinages, sign board made of compact aluminium panel sheet or HPL sheet of approved shade , providing 3mm vinyl pased letters with multi language and logos of approved sizes, providing side hangers fixing in position,providing centre handers using Ms rods amn chains etc. displaying scope of services, room numbers, doctors rooms, HOD rooms, floor wise facilities ,radiation sinages, mandatory notification as directed by the engineer in charge with one side lettering for fixed in wall and both sides as in projected type etc. complete to detailed pre approved plan.<br>Passages handing types -60x15cm -both side <br>

100

-

-

... More
od56194/2022_2023 : Providing and fixing / holding sinages, sign board made of compact aluminium panel sheet or HPL sheet of approved shade , providing 3mm vinyl pased letters with multi language and logos of approved sizes, providing side hangers fixing in position,providing centre handers using Ms rods amn chains etc. displaying scope of services, room numbers, doctors rooms, HOD rooms, floor wise facilities ,radiation sinages, mandatory notification as directed by the engineer in charge with one side lettering for fixed in wall and both sides as in projected type etc. complete to detailed pre approved plan.<br>Name board rooms -60x15cm - one side<br>

15

-

-

... More
od56198/2022_2023 : Providing acrylic LED multi language letter (engilsh & malayalam) singaes on the building using three dimensional acrylic channel LED lighting with high bright BGST 0.92 watt water peoof neutral white (280 K) LED modules as per detailed and approvd drawing including minimum 5 year varenty including lighting , placing in position and securing the sinages etc. as per the direction of engineer in charge.<br>

57.93

-

-

... More
16.59.1 : Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC: 67- 2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class-2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x 5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours). Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction of Engineer-in-Charge.Mandatory / Regulatory sign boards of 900 mm diametre with support length of 3750 mm

10

-

-

... More
16.59.2 : Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC: 67- 2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class-2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x 5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours). Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction of Engineer-in-Charge.Cautionary / warning sign boards of equilateral triangular shape having each side of 900 mm with support length of 3650 mm

5

-

-

... More
16.61 : Providing Retro - reflective regulatory sign board of size 900 mm diameter made out of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated lens type retro reflective sheeting as approved by Engineer-in-Charge. Letter, symbols, borders etc. will be as per IRC. 67 with required colour scheme on the boards and with the high intensity grade A. The aluminium sheet to be riveted to M.S. frame of M.S. angle 50x50x4 mm , 4 m long welded to the frame with adequate anti-theft arrangement. Sheet work to be painted with two or more coats of synthetic enamel paint over an under coat ( primer ) and back side of aluminium sheet to be painted with two or more coats of epoxy paint including appropriate priming coat complete in all respects as per direction of Engineer- in-charge .

5

-

-

... More
630kVA 11kV/433V Cast Resin (Dry type) Indoor USS Transformer

-

-

-

... More
od55515/2022_2023 : Supply, installation, testing & commissioning of 630kVA 11kV/433V 3 phase Unitized substation Vector DYN-11 , copper double wound, transformer with 630 AMPS 350 MVA LBS , and all other components/accessories and off circuit tappings from +5% to -10% in steps of 2.5%, changeable on offcircuit by tap links provided, with WTI & LV terminals suitable for 4 runs of A2XFY cable and, with incoming suitable for XLPE cable, with all other standard fittings and accessories confirming to IS:2026/77, 11171/85. including separate winding temperature indicator for each phase and core in the Transformer, with all accessories, complete as required as per State electricity board, ECBC, IE rules specifications. Losses shall be within the limits prescribed in KSECBC 2017. Total losses for the transformer should conform to IS 2026:part 11 2007. Maximum losses at 50% loading should be less than 4.5kW and maximum losses at 100% loading should be less than 12kW. Seperate metering class CT & PT should be provided for periodic loss monitoring using digital meter. Transformer and all accesories included shall be supplied with warranty against manufacturing /defects/ damages during the entire defects liability period. No excemption in any components will be accepted. Cable entry & outgoing for transformer shall be as per site coniditon,to be confirmed before manufacturing. Colling shall be ANAN. Push button for emergency OFF shall be placed outside in seperate enclosure, painted in red covered by glass. <br>

1

-

-

... More
HT PANEL BOARD

-

-

-

... More
od55534/2022_2023 : Supply, installation, testing and commissioning of dust and vermin proof floor mounted free standing cubicle type, 11kV, extensible panel board made out of metal clad fully compartmentalised complete with hinged and earthed front doors interlocked with the earth switch, comprising of one number of 630A VCB as incomer with two numbers of 630A VCB as outgoings as per the specification details below. Panel shall be factory fitted type with type testing certificates as per IEC 62271 Part 100(for VCB) & Part 200(for enclosure). Panel shall be supplied with warranty against manufacturing / maintenance defects/ damages by manufacturer during the entire defects liability period. No excemption in any components will be accepted for warranty exemptions. All CTs & PTs shall be type tested as per standards and certificates shall be produced before supply of the panel test shall include but not limited to polarity test, high voltage power-frequency one minute withstand test, induced over voltage test, partial discharge measurement, accuracy test, intertum insultation test, dimension check, ratio and phase angle error test etc. Insulation resistance test and fuctional testes of panel and VCB shall be produced. Fuctuional tests shall include but not be limited to mechanical operation test for opening and closing under no load condition, master trip relay and auxilary relays, over current and earth fault relay test, breaker rack IN and Rack OUT , MFM, voltmeter, ammeter and all other meters programmed and checked, motor charging etc. Panel shall include all relays and tripping mechanisms and accesories as required as per KSEI standards. Cable entry & outgoing for transformer shall be as per site coniditon,to be confirmed before manufacturing. HT panel board shall be manufactured with provision for installing HT TOD bidirection meter in incomer side as per schematic layout with necessary CTs and all accesories as required. All VCBs shall be with Modbus communication protocol and RS485 and ethernet ports for incorporation with IBMS / EMS as required.<br>Incoming:<br>1no:-11kV 630A, 3phase 50Hz, 350MVA, breaking capacity vacuum circuit breaker dust and vermin proof totally enclosed in sheet steel housing, fully inter locked, horizontal draw out and horizontal isolation, indoor truck type with trip free spring closing mechanism with mechanical ON/OFF indicators, earthing terminals automatic safety shutters, complete with auxiliary contacts, resin cast CTs of suitable ratio and accuracy class for protection & metering(Class0.2 S). Contractor shall quote the price with 50/5A 0.2S class metering CT, but CT ratio shall be finalised as per contract demand during the course of work.<br>Draw out type resin cast P.T with inbuilt fuses of ratio 11kV/110V, CL :0.2S must be provided. Bus bar compartment shall have suitable capacity non-hygroscopic and high dieletric strength SMC/FRP busbar supports with electrolytic aluminium busbars covered with suitable sleeves. WIth breaker control switch, switch with plug point, strip heater, thermostat for space heater, cubicle lamp with switch, seal of bushings including all connections and interconnections. Metering compartments for mounting digital meter and numerical relays for feeder protection, shunt/series trip coil, under voltage release, indication lamps, spring charge, trip circuit healthy, alram, RYM indication cable entry boxes, including all interconnections, providing fire/heat resistant coatings for busbar & CB truck enclosures and powder coating complete panel as per IS-2516 & IS 3427 with latest amendments complete as required with manually charged spring closing system. It shall also be provided with Instantenous IDMT relay 2 O/C + 1 E/F relay CDAG-51 or Equivalent with high Set, Master Trip Relay. Provision shall be provided for fixing TOD meter including connections. Unidirectional Solar meter space provision on the LT compartment shall also be envisaged during construction for meter installaion by Solar agency for KSEB liasion<br>Out goings :<br>2 nos:-11kV 630A, 3phase 50Hz, 350MVA, breaking capacity vacuum circuit breaker dust and vermin proof totally enclosed in sheet steel housing, fully inter locked, horizontal draw out and horizontal isolation, indoor truck type with trip free spring closing mechanism with mechanical ON/OFF indicators, earthing terminals automatic safety shutters, complete with auxiliary contacts<br>Bus bar compartment shall have suitable capacity non-hygroscopic and high dieletric strength SMC/FRP busbar supports with electrolytic aluminium busbars covered with suitable sleeves. WIth breaker control switch, switch with plug point, strip heater, thermostat for space heater, cubicle lamp with switch, seal of bushings including all connections and interconnections. Metering compartments for mounting digital meter and numerical relays for feeder protection, shunt/series trip coil, under voltage release, indication lamps, spring charge, trip circuit healthy, alram, RYM indication cable entry boxes, including all interconnections, providing fire/heat resistant coatings for busbar & CB truck enclosures andpowder coating complete panel as per IS-2516 & IS 3427 with latest amendments complete as required with manually charged spring closing system. It shall also be provided with Instantenous IDMT relay 2 O/C + 1 E/F relay CDAG-51 or Equivalent with high Set, Master Trip Relay. <br>The panel shall include auxillary DC power supply unit, 24V, with required Ah capacity battery power pack including all accesories required for complete backup of all indicators, mechanisam and operating system in the panel with stationary type, high discharge perfomance,Valve Regulated Lead Acid (VRLA) sealed maintenance free battery, battery charger including all other accessories like battery rack, interconnecting cables etc as required The power pack and accesories shall be placed in the panel itself.<br>

1

-

-

... More
HT CABLE SUPPLY & LAYING

-

-

-

... More
od55540/2022_2023 : Supply of following 11kV (E), stranded compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, XLPE Insulated, Insulation Screening with extruded Semi Conducting Compound in combination with Copper Tape, cores laid up, innersheath of PVC tape, galvanised flat steel strip armoured and overall PVC Sheathed Cable conforming to IS 7098 / (PART-II) 1985 with latest amendments.<br><br>3cx300sq.mm XLPE Cable<br>

86

-

-

... More
od55552/2022_2023 : Laying of following 11kV (E) grade XLPE insulated PVC sheathed compact circular armoured aluminium conductor HT power cable, insulation screened with extruded semi conducting compound in separate existing cable tray/ on surface using factory made clamps and the spacing between clamps will not exceed 60cm.<br>Above 120 sq. mm and upto 400 sq. mm<br>

20

-

-

... More
8.3.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm

12

-

-

... More
8.4.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.Above 120 sq. mm and upto 400 sq. mm

54

-

-

... More
BIDIRECTIONAL HT TOD NET METER

-

-

-

... More
od55579/2022_2023 : Supply, Installation, testing & commissioning of 3 phase 4 wire according to IS14697-1999, CBIP-325, IS 159595A, class: 0.2S, Bidirectional TOD meter with RS485 port, LCD with backlit display of Electricity board approved make, in existing enclosures of HT panel including all necessary accessories for fixing and connection complete as required getting tested and approved from statutory authorities, providing connection/inter-connections as required for complete installation and as instructed by engineer in charge/consultant. <br><br>Supply,Installation, testing and commisioning<br>

1

-

-

... More
HV CABLE END TERMINATION

-

-

-

... More
10.4.4 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm

5

-

-

... More
10.5.4 : Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm

1

-

-

... More
od55942/2022_2023 : Upgrading of existing HT supply point of the existing DP structure at site from which 11kV connection is taken, enhancing the supply point to carter to the newly proposed connected load and transformer rating, getting approvals, submitting completion certificates, upgrading the existing DP structure components such as HT fuses, AB switch and making new the damages, removing the existing HT cable connections for providing new cable connection, complete as required for taking cable connection to the new transformer for the premisis, making the entire premiss as a single HT consumer, making necessary changes and getting approvals complete as required<br>

1

-

-

... More
DESIEL GENERATORS, EXHAUST PIPES & ALLIED WORKS

-

-

-

... More
od55211/2022_2023 : 250kVA DESIEL GENERATORS<br>Supply, installation, testing and commissioning of radiator cooled 3 phase, 415V±0.1%, 0.8 pf 50hz. prime rated DG set of the rating 250 kVA comprising of diesel engine, alternator, fuel tank, starting system, battery, battery charger, electronic governor etc with all accessories required for load sharing with another DG set of same rating and automatic operation using AMF & PLC system, communication with PLC system etc, communication ports for integration with EMS & IBMS. The battery charger shall be included by the same manufacturer of auxillary DC power supply unit, with dry batteries with connecting leads and terminals with stationary type, high discharge perfomance, Valve Regulated Lead Acid (VRLA) sealed maintenance free battery and charger including all other accessories like interconnecting cables etc as required. The Generator set shall have a integral type acoustic enclosure as per latest CPCB II norms. <br>"The generator set shall be supplied in accordance but not limited with the following codes and standards - ISO 8528, ISO 3046, ISO 9001, BIS, CIEG, State electricity board regulation, BSI, state pollution control board, central pollution control board, Indian electricity rules , CPWD, IEC, ECBC & GRIHA standards, Alternator in accordance with IS: 4722/BS: 2613/IEC-34(Part-1), Specification for AC Generators driven by Reciprocating Engine: IS 13364(1-2)/1992, • Performance class of the DG SET Shall be as per ISO8528 to obtain following parameters - Steady-State Frequency Band = ≤0.5 %, Maximum Frequency Dip = ≤-7 %, Maximum Frequency Rise = ≤+10 %, Frequency Recovery Time - 3 sec, Steady-State Voltage Deviation = ≤ ± 1 %, Maximum Voltage Dip = ≤-15 %, Maximum Voltage Rise = ≤+20%, Voltage Recovery Time = 4 Sec. <br>"<br>The DG sets performance class shall be suitable to power highly non - linear loads. The supplier shall warrant the equipment to be free from defects in material and workmanship for the entire defects liability period. The Engine shall be suitable to drive alternator of base load application 24/7 operation. Engine/generator sets shall meet emergency power requirement to start and be on line within 10 seconds of onset of failure.<br>"Diesel Engine of required bhp, stationary type and four stroke with Inline cylinder arrangement shall be complete with integral air intake through suitable air filters and exhaust system, speed regulation system, fuel injection system, lube oil system, silencers, self-contained piping, instruments, mounted on anti-vibration mounts, turbo charged, multi- cylinder, 4-stroke, with continous power output at 1,500 r.p.m battery started .The engine shall have 10% overload capacity for one hour in every 12 hours of operation as per ISO. Fuel system shall comprise of fuel pump, fuel injectors, fuel filter, fuel hoses, lube oil pump, lube oil priming pump, lube oil filter, bypass filter etc. The DG set shall be supplied with standard fuel tank as per manufacturer standard within the canopy itself. <br>"<br>Following protection/warning shall be provided but not limited to with the DG set, Engine over Speed Shutdown, Low Lube Oil Pressure Warning /Shutdown, High Coolant Temperature Warning / Shutdown, Low Coolant Level Warning / Shutdown, Low Coolant Temperature Warning, Low And High Battery Voltage Warning, Weak Battery Warning, Dead Battery Shutdown, Over Crank Shutdown, Fail To Crank Shutdown. The governor shall be Electronic type confirming complete with Display unit and shall be a self-contained unit capable of monitoring speed.The engine/generator sets shall be provided with electronic governors suitable for unattended automatic paralleling and load sharing. <br>"The DG Set shall be supplied with micro-processor based generator monitoring, metering & protection feature with display viz Analogue & Digital AC output metering, Battery monitoring system to sense and warn against a weak battery condition.,Digital alarm & status message display, Overload, Overcurrent, Over voltage, Under voltage, Over frequency, Under frequency, Reverse Power Relay, Restricted Earth Fault<br>"<br>Controller shall be equiped with auto, manual, start, stop, fault reset and lamp test/panel lamp switches with alpha-numeric displays and push buttons, indications for genset running, remote start, not in auto, common shutdown, common warning, manual run mode, auto mode, stop etc with sync check. For alternator - line to neutral and line to line volts indication, current, frequency, kW, kVAr, power factor kVA and for engine following indications - DC voltage, engine speed, lube oil pressure, coolant temperature, coolant low level, comprehensive data, with start/stop attempts, runnings hours, kW hours, load profile, fault history, datta logging etc and all data shall be recoreded. Generator shall be including dust and vermin proof, type standard control panel board within the canopy, comprising of one number Microprocessor based MCCB rating of 400A, 4pole, 36 kA breaking capacity, thermal over load, voltage controlled O/C relay, over voltage, under voltage, negative sequence relay, voltmeter with selector switch, 3 ammeters of 0-400A range, frequency meter, kW, pf, electronic energy meter with CTs and indicating lamps with fuse and switch control etc. as complete with necessary control wiring interconnections etc. The DG controller shall be with necessary communication protocol to communicate the DG sets with PLC and IBMS<br>(Energy meters & CTs shall be tested and certificate shall be obtained from electrical inspectorate lab) Following sanction may be obtained by the contractor,<br>(i) Sanctions from Municipality/ Corporation<br>(ii) Sanction from Pollution control Board<br>(ii) Sanction from electrical inspectorate<br>Outdoor acoustic enclosure for the DG set. The sound level shall be brought down to 70DB+/-5 with at a distance of 1m (as per CPCB norms the sound level shall be 75dB at a distance of 1m from the silencer at the top of the enclosure).Accoustic enclosure shall be provided as per manufacturer standards confirmining to CPWD standards mentioned. Doors shall be openable on either side.Sufficient fresh air intake and hot air outlet with splitters to be arranged so that the temperature inside should not increase to 5 degree above ambient temperature. (The enclosure shall bare certificate from the generator manufacturer conforming the CPCB II norms and serial numbers of the test certificate).The supply of DG set shall include first filling of oil and lube for commissioning of the DG set. Push button for emergency OFF shall be placed outside in seperate enclosure, painted in red covered by glass.<br>Supply, Installation, testing and commisioning<br>

2

-

-

... More
EXHAUST PIPES

-

-

-

... More
od55224/2022_2023 : Supply, erection, commissioning of additional length of exhaust pipes with long radius bend from residential silencer with necessary clamps, fixtures, etc painted with heat resistant, rust proof, bituminous paint of approved colors to a maximum of 10 m in stages of following sizes including suitable rain cap at top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. It is also recommended that horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other acessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for istallation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbocharger. Exhaust pipe height shall be 3m more than the top of any adjacent building withing 10m radius of the exhaust.<br>150mm dia <br>

20

-

-

... More
od55245/2022_2023 : Supply & providing thermal insulation for silencer with inner glass wool and providing aluminium cladding for DG set silencer as per standards.<br>

2

-

-

... More
od55445/2022_2023 : Supply & providing insulation for exhaust pipe with thermal insulation and providing aluminium cladding as per standards.<br>

10

-

-

... More
od55469/2022_2023 : DG set commisioning of both 250kVA DG sets including Trial run of DG sets on no-load and variable load condition and to record the parameters as per prescribed format as per manufacturer standards. Cost of consumable ( fuel oil, lube oil, etc.) to be borne by Contractor. This shall also include first fill of diesel for commisiong of the DG set. Full tank Diesel shall be filled for initial commisioning for both DG .<br>

1

-

-

... More
EXHAUST PIPES - CIVIL ITEMS

-

-

-

... More
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

500

-

-

... More
CPRI CERTIFIED MV PANELS AS PER IS 8623

-

-

-

... More
od56799/2022_2023 : MAIN PANEL <br>Incomer -<br>EB Incomer - 1000A 50kA FP EDO Microprocessor based ACB with 3 O/C and 1 E/F releases. Standby low set E/F relay with CT at neutral earthing strip -1 No.<br>DG Incomer 1 & 2 - 400A 36 kA FP MCCB Microprocessor based with 400A FP Contactor- 2 Nos. <br>1000A,FP,50kA.EDO Microprocessor based Buscoupler- 1 no<br>1000A 433V best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required, as per IEC norms<br>RYB phase indicating LED lamps with control fuses and switches - 3 set.<br>Multifunction meter as per IEC 62053-21, specified above including CTs and all accesories- 3 set<br>All CTs as required for complete installation<br>Class B Surge arrestor with HRC fuses for backup as per manufacturer standard, including copper cable connection between arrestor and fuses - 2 set<br>Reverse power relay with CTs and accessories - 2 nos<br>PLC with demand controller and auto main faiuler feature to automatically turn ON each DG set automatically during power supply failure, including turning ON DG sets as per confirmed interlocking chart, turning ON/OFF as per demand, complete control of DG set as required, including PLC, and all other accesoires and connections complete as required<br>Outgoings<br>500A 36kA TP Microprocessor based MCCB - 2 nos<br>400A 36kA TP Microprocessor based MCCB - 1 no<br>320A 36kA TP Microprocessor based MCCB - 4 nos<br>250A 36kA TP Microprocessor based MCCB - 1 no<br>315A FP Isolator - 1 no<br>Multifunction meter as per IEC 62053-21, specified above including CTs and all accessories - 8 set<br>

1

-

-

... More
od56802/2022_2023 : UPS IN PANEL <br>Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor / wall mounted, front operated MV panel board as per IS 8623, CPRI Certified, compartmentalised (minimum form 3b) complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. These panel should include surge arrester Class B or Class B+C/ Class 1+2 as per IEC 61643 (IP 20) with remote indication for defective arresters, arrester Spark Gap type to connect between Neutral and Earth.complete with back up fuse for SPD protection as per manufacturer standard. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. All switchgears shall be with with spreader links and rotary handle. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. Necessary electrical and mechanical interlocking arrangements shall be provided as per scehmatic drawing to achieve operational functionalityAll panels shall be with separate channels isolated from LT cable chambers for running of RS485 & other ELV cables for integration with EMS & IBMS. Switchgears and meters shall be with necessary communication ports for integration with BMS & EMS and Potential free contacts for BMS. All panel meters should be with RS485 ports for EMS integration. All Multifunction meter shall be as per IEC 62053-21, class 1, having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be capable of integration with EMS SoftwareAll opening parts of the panel shall be sealable. Panels shall be complete with Al bus bars, separate earth bus bar to be provided through out the length of the panel along with base chanel of suitable size, cable alleys as per requirement, complete, numbering, danger plate etc as required as per specifications and drawings. Current density for busbarsize shall be designed considering not more than 0.8 A/sq.mm for aluminium. The switchgear live parts shall be isolated with proper insulation material. All switchgears shall be with spreader links, operating knobs/handles, DIN rail provision for isolators with required cable alleys. The panel design shall be in accordance with IS & Kerala state norms. All panels shall be cable alleys and seperate bus bar compartments for easy terminations as per KSEI standards with proper clearances. <br>Incomer -<br>320A 36kA FP Microprocessor based MCCB - 1 nos<br>320A 433V best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required, as per IEC norms<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Class B Surge arrestor with HRC fuses for backup as per manufacturer standard, including copper cable connection between arrestor and fuses - 1 set<br>Outgoings<br>160A 36 kA FP MCCB Microprocessor based - 3 Nos. <br>RYB phase indicating LED lamps with control fuses and switches - 3 set.<br>Multifunction meter as per IEC 62053-21, specified above including CTs and all accessories - 3 set<br>

1

-

-

... More
od56841/2022_2023 : UPS OUT PANEL <br>Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor / wall mounted, front operated MV panel board as per IS 8623, CPRI Certified, compartmentalised (minimum form 3b) complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. These panel should include surge arrester Class B or Class B+C/ Class 1+2 as per IEC 61643 (IP 20) with remote indication for defective arresters, arrester Spark Gap type to connect between Neutral and Earth.complete with back up fuse for SPD protection as per manufacturer standard. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. All switchgears shall be with with spreader links and rotary handle. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. Necessary electrical and mechanical interlocking arrangements shall be provided as per scehmatic drawing to achieve operational functionalityAll panels shall be with separate channels isolated from LT cable chambers for running of RS485 & other ELV cables for integration with EMS & IBMS. Switchgears and meters shall be with necessary communication ports for integration with BMS & EMS and Potential free contacts for BMS. All panel meters should be with RS485 ports for EMS integration. All Multifunction meter shall be as per IEC 62053-21, class 1, having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be capable of integration with EMS SoftwareAll opening parts of the panel shall be sealable. Panels shall be complete with Al bus bars, separate earth bus bar to be provided through out the length of the panel along with base chanel of suitable size, cable alleys as per requirement, complete, numbering, danger plate etc as required as per specifications and drawings. Current density for busbarsize shall be designed considering not more than 0.8 A/sq.mm for aluminium. The switchgear live parts shall be isolated with proper insulation material. All switchgears shall be with spreader links, operating knobs/handles, DIN rail provision for isolators with required cable alleys. The panel design shall be in accordance with IS & Kerala state norms. All panels shall be cable alleys and seperate bus bar compartments for easy terminations as per KSEI standards with proper clearances. <br>Incomer -<br>160A 36 kA FP MCCB Microprocessor based - 3 Nos. <br>320A 433V best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required, as per IEC norms<br>Multifunction meter as per IEC 62053-21, specified above including CTs and all accessories - 3 set<br>RYB phase indicating LED lamps with control fuses and switches - 3 set.<br>Class B Surge arrestor with HRC fuses for backup as per manufacturer standard, including copper cable connection between arrestor and fuses - 1 set<br>Outgoings<br>320A 36kA FP Microprocessor based MCCB - 1 no<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>

1

-

-

... More
od56849/2022_2023 : 150 kVAr APFC PANEL<br>Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor / wall mounted, front operated MV panel board as per IS 8623, CPRI Certified, compartmentalised (minimum form 3b) complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. These panel should include surge arrester Class B or Class B+C/ Class 1+2 as per IEC 61643 (IP 20) with remote indication for defective arresters, arrester Spark Gap type to connect between Neutral and Earth.complete with back up fuse for SPD protection as per manufacturer standard. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. All switchgears shall be with with spreader links and rotary handle. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. Necessary electrical and mechanical interlocking arrangements shall be provided as per scehmatic drawing to achieve operational functionalityAll panels shall be with separate channels isolated from LT cable chambers for running of RS485 & other ELV cables for integration with EMS & IBMS. Switchgears and meters shall be with necessary communication ports for integration with BMS & EMS and Potential free contacts for BMS. All panel meters should be with RS485 ports for EMS integration. All Multifunction meter shall be as per IEC 62053-21, class 1, having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be capable of integration with EMS SoftwareAll opening parts of the panel shall be sealable. Panels shall be complete with Al bus bars, separate earth bus bar to be provided through out the length of the panel along with base chanel of suitable size, cable alleys as per requirement, complete, numbering, danger plate etc as required as per specifications and drawings. Current density for busbarsize shall be designed considering not more than 0.8 A/sq.mm for aluminium. The switchgear live parts shall be isolated with proper insulation material. All switchgears shall be with spreader links, operating knobs/handles, DIN rail provision for isolators with required cable alleys. The panel design shall be in accordance with IS & Kerala state norms. All panels shall be cable alleys and seperate bus bar compartments for easy terminations as per KSEI standards with proper clearances.<br> 150 kVAr with 7% harmonic block reactor copper wound with tuned heavy duty box type capacitors with heavy duty polypropylene as a dielectric with vaccum deposited conductors on the polypropylene as electrodes using contactor swtiching, using Microprocessor based relay operated controller with 8 stage which should be capable to switch on the required kVAr for compensation based on cyclic switching. All controls shall be mounted on enclosure door with door interlocks. Heavy duty capacitor duty contactors with high rupturing MCCB shall be used for individual stage control. Box type heavy duty capacitor with following characteristics but not limited to- Over current withstand capability 1.8 x In, Operating losses < 0.35 W/kVAr, Peak Inrush current withstand capability 300 x In, and Max. Temperature of 55ºC and long operating life. Each capacitor shall be in seperate compartment<br>Incomer - 400A 36kA 4P MCCB, microprocessor based with high rupturing capacity and in built overload and short circuit releases as per specifications as incomer <br>400A 433V best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required, as per IEC norms<br>Class B Surge arrestor with HRC fuses for backup as per manufacturer standard, including copper cable connection between arrestor and fuses - 1 set<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Multifunction meter as per IEC 62053-21, specified above including CTs and all accessories - 1 set<br>8 stage APFC relay - 1 no<br>APFC panel capacitor segregation to achieve 150 kVAr shall be as below -<br>125A TP high rupturing capacity MCCB with 125A TP contactor for 2 nos x 27.7 kVAr Capacitors in parallel with 7% harmonic block reactor - 1 set<br>63A TP high rupturing capacity MCCB with 63A TP contactor for 27.7 kVAr Capacitor with 7% harmonic block reactor - 1 set<br>50A TP high rupturing capacity MCCB with 50A TP contactor for 20 kVAr Capacitor with 7% harmonic block reactor - 1 set<br>32A TP high rupturing capacity MCCB with 32A TP contactor for 11.1 kVAr Capacitor with 7% harmonic block reactor - 1 set<br>16A TP high rupturing capacity MCCB with 16A TP contactor for 4.4 kVAr Capacitor with 7% harmonic block reactor - 1 set<br>10A TP high rupturing capacity MCCB with 10A TP contactor for 3.3 kVAr Capacitor with 7% harmonic block reactor - 2 set<br>100A TP high rupturing capacity MCCB for (2 x 20 kVAr = 40 kVAr) Capacitor to be connected for No Load Compensation directly to transformer - 1 set<br>"All compartments shall be with Push Buttons, R Y B Indication with control fuse -1Set, Automanual selector switch- 1No , Forced cooling using fans (both manual and automatic operation of fans should be possible with Auto/Manual toggle) including all connections and interconnections, all accesories as required for complete installation as instructed by engineer in charge/consultant. <br>"<br>

1

-

-

... More
od56853/2022_2023 : FIRE PANEL <br>Incomer -<br>315A TPN Isolator - 1 No.<br>315A 433V, 25kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Surge Protection Device Class B+C/ Class 1+2 with HRC fuses for backup as per manufacturer standard, including copper cable connection between arrestor and fuses - 1 set<br>Outgoings<br>200A TP ISOLATOR for 50HP pump along with starter w/o OLR, controllers, PB, indicators and all other accessories required as per fire norms - 1 no.<br>63A TP ISOLATOR for 12HP pump along with starter w/o OLR, controllers, PB, indicators and all other accessories required as per fire norms - 1 nos.<br>63A TP ISOLATOR - 1 nos.<br>Multifunction meter as per IEC 62053-21, specified above including CTs and all accessories - 1 set<br>

1

-

-

... More
od56875/2022_2023 : UTILITY PANEL <br>Incomer -<br>250A FP Isolator - 1 No.<br>63A 25kA FP Thermal magnetic based MCCB - 1 no<br>250A 433V, 25kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>RYB phase indicating LED lamps with control fuses and switches - 2 set.<br>Multifunction meter as per IEC 62053-21, specified above including CTs and all accessories - 2 set<br>Surge Protection Device Class B with HRC fuses for backup as per manufacturer standard, including copper cable connection between arrestor and fuses - 1 set<br>Outgoings<br>100A 25kA TP Thermal Magnetic Based MCCB - 5 nos<br>63A 25kA TP Thermal Magnetic Based MCCB - 3 nos<br>Multifunction meter as per IEC 62053-21, specified above including CTs and all accessories - 8 set<br>

1

-

-

... More
od56893/2022_2023 : MEDICAL GAS PANEL<br>Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor / wall mounted, front operated MV panel board as per IS 8623, CPRI Certified, compartmentalised (minimum form 3b) complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. These panel should include surge arrester Class B or Class B+C/ Class 1+2 as per IEC 61643 (IP 20) with remote indication for defective arresters, arrester Spark Gap type to connect between Neutral and Earth.complete with back up fuse for SPD protection as per manufacturer standard. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. All switchgears shall be with with spreader links and rotary handle. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. <br>Necessary electrical and mechanical interlocking arrangements shall be provided as per scehmatic drawing to achieve operational functionality<br>All panels shall be with separate channels isolated from LT cable chambers for running of RS485 & other ELV cables for integration with EMS & IBMS. Switchgears and meters shall be with necessary communication ports for integration with BMS & EMS and Potential free contacts for BMS. All panel meters should be with RS485 ports for EMS integration. <br>All Multifunction meter shall be as per IEC 62053-21, class 1, having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be capable of integration with EMS Software<br>All opening parts of the panel shall be sealable. Panels shall be complete with Al bus bars, separate earth bus bar to be provided through out the length of the panel along with base chanel of suitable size, cable alleys as per requirement, complete, numbering, danger plate etc as required as per specifications and drawings. Current density for busbarsize shall be designed considering not more than 0.8 A/sq.mm for aluminium. The switchgear live parts shall be isolated with proper insulation material. All switchgears shall be with spreader links, operating knobs/handles, DIN rail provision for isolators with required cable alleys. The panel design shall be in accordance with IS & Kerala state norms. All panels shall be cable alleys and seperate bus bar compartments for easy terminations as per KSEI standards with proper clearances. <br>Incomer -<br>100A FP Isolator - 1 no<br>100A 433V, 25kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Surge Protection Device Class B+C/ Class 1+2 with HRC fuses for backup as per manufacturer standard, including copper cable connection between arrestor and fuses - 1 set<br>Outgoings<br>63A 16kA TP Thermal Magnetic Based MCCB - 7 nos<br>

1

-

-

... More
od56895/2022_2023 : LIFT PANEL 2<br>Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor / wall mounted, front operated MV panel board as per IS 8623, CPRI Certified, compartmentalised (minimum form 3b) complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. These panel should include surge arrester Class B or Class B+C/ Class 1+2 as per IEC 61643 (IP 20) with remote indication for defective arresters, arrester Spark Gap type to connect between Neutral and Earth.complete with back up fuse for SPD protection as per manufacturer standard. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. All switchgears shall be with with spreader links and rotary handle. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. <br>Necessary electrical and mechanical interlocking arrangements shall be provided as per scehmatic drawing to achieve operational functionality<br>All panels shall be with separate channels isolated from LT cable chambers for running of RS485 & other ELV cables for integration with EMS & IBMS. Switchgears and meters shall be with necessary communication ports for integration with BMS & EMS and Potential free contacts for BMS. All panel meters should be with RS485 ports for EMS integration. <br>All Multifunction meter shall be as per IEC 62053-21, class 1, having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be capable of integration with EMS Software<br>All opening parts of the panel shall be sealable. Panels shall be complete with Al bus bars, separate earth bus bar to be provided through out the length of the panel along with base chanel of suitable size, cable alleys as per requirement, complete, numbering, danger plate etc as required as per specifications and drawings. Current density for busbarsize shall be designed considering not more than 0.8 A/sq.mm for aluminium. The switchgear live parts shall be isolated with proper insulation material. All switchgears shall be with spreader links, operating knobs/handles, DIN rail provision for isolators with required cable alleys. The panel design shall be in accordance with IS & Kerala state norms. All panels shall be cable alleys and seperate bus bar compartments for easy terminations as per KSEI standards with proper clearances. <br>Incomer -<br>63A FP Modular Isolator - 1 no<br>63A 433V, 16kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Surge Protection Device Class B+C/ Class 1+2 with HRC fuses for backup as per manufacturer standard, including copper cable connection between arrestor and fuses - 1 set<br>Outgoings<br>40A 100mA FP RCBO - 1 nos<br>25A 30mA DP RCBO - 1 no<br>25A best conductivity extensible Al SPN bus bar<br>6A SP MCB - 4 nos<br><br>

1

-

-

... More
od56898/2022_2023 : LIFT PANEL 1<br>Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor / wall mounted, front operated MV panel board as per IS 8623, CPRI Certified, compartmentalised (minimum form 3b) complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. These panel should include surge arrester Class B or Class B+C/ Class 1+2 as per IEC 61643 (IP 20) with remote indication for defective arresters, arrester Spark Gap type to connect between Neutral and Earth.complete with back up fuse for SPD protection as per manufacturer standard. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. All switchgears shall be with with spreader links and rotary handle. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. <br>Necessary electrical and mechanical interlocking arrangements shall be provided as per scehmatic drawing to achieve operational functionality<br>All panels shall be with separate channels isolated from LT cable chambers for running of RS485 & other ELV cables for integration with EMS & IBMS. Switchgears and meters shall be with necessary communication ports for integration with BMS & EMS and Potential free contacts for BMS. All panel meters should be with RS485 ports for EMS integration. <br>All Multifunction meter shall be as per IEC 62053-21, class 1, having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be capable of integration with EMS Software<br>All opening parts of the panel shall be sealable. Panels shall be complete with Al bus bars, separate earth bus bar to be provided through out the length of the panel along with base chanel of suitable size, cable alleys as per requirement, complete, numbering, danger plate etc as required as per specifications and drawings. Current density for busbarsize shall be designed considering not more than 0.8 A/sq.mm for aluminium. The switchgear live parts shall be isolated with proper insulation material. All switchgears shall be with spreader links, operating knobs/handles, DIN rail provision for isolators with required cable alleys. The panel design shall be in accordance with IS & Kerala state norms. All panels shall be cable alleys and seperate bus bar compartments for easy terminations as per KSEI standards with proper clearances. <br>Incomer -<br>100A FP Modular Isolator - 1 no<br>100A 433V, 16kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Surge Protection Device Class B+C/ Class 1+2 with HRC fuses for backup as per manufacturer standard, including copper cable connection between arrestor and fuses - 1 set<br>Outgoings<br>40A 100mA FP RCBO - 2 nos<br>25A 30mA DP RCBO - 1 no<br>25A best conductivity extensible Al SPN bus bar<br>6A SP MCB - 6 nos<br>

1

-

-

... More
od56901/2022_2023 : EXTERIOR LIGHTING PANEL<br>Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor / wall mounted, front operated MV panel board as per IS 8623, CPRI Certified, compartmentalised (minimum form 3b) complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. These panel should include surge arrester Class B or Class B+C/ Class 1+2 as per IEC 61643 (IP 20) with remote indication for defective arresters, arrester Spark Gap type to connect between Neutral and Earth.complete with back up fuse for SPD protection as per manufacturer standard. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. All switchgears shall be with with spreader links and rotary handle. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. <br>Necessary electrical and mechanical interlocking arrangements shall be provided as per scehmatic drawing to achieve operational functionality<br>All panels shall be with separate channels isolated from LT cable chambers for running of RS485 & other ELV cables for integration with EMS & IBMS. Switchgears and meters shall be with necessary communication ports for integration with BMS & EMS and Potential free contacts for BMS. All panel meters should be with RS485 ports for EMS integration. <br>All Multifunction meter shall be as per IEC 62053-21, class 1, having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be capable of integration with EMS Software<br>All opening parts of the panel shall be sealable. Panels shall be complete with Al bus bars, separate earth bus bar to be provided through out the length of the panel along with base chanel of suitable size, cable alleys as per requirement, complete, numbering, danger plate etc as required as per specifications and drawings. Current density for busbarsize shall be designed considering not more than 0.8 A/sq.mm for aluminium. The switchgear live parts shall be isolated with proper insulation material. All switchgears shall be with spreader links, operating knobs/handles, DIN rail provision for isolators with required cable alleys. The panel design shall be in accordance with IS & Kerala state norms. All panels shall be cable alleys and seperate bus bar compartments for easy terminations as per KSEI standards with proper clearances. <br>Incomer -<br>40A FP Modular Isolator - 1 no<br>40A 433V, 16kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>Astronomical time switch for automatic switching On & Off of street lights at sun set & sun rise or twilight (Auto ON, Auto Off, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay - 1 no.<br>40A TP Contactor - 1 no<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Surge Protection Device Class B+C/ Class 1+2 with HRC fuses for backup as per manufacturer standard, including copper cable connection between arrestor and fuses - 1 set<br>Outgoings<br>25A TP MCB - 3 nos<br>25A SP MCB - 3 nos<br>

1

-

-

... More
od56930/2022_2023 : PLUMBING PANEL<br>Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor / wall mounted, front operated MV panel board as per IS 8623, CPRI Certified, compartmentalised (minimum form 3b) complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. These panel should include surge arrester Class B or Class B+C/ Class 1+2 as per IEC 61643 (IP 20) with remote indication for defective arresters, arrester Spark Gap type to connect between Neutral and Earth.complete with back up fuse for SPD protection as per manufacturer standard. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. All switchgears shall be with with spreader links and rotary handle. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. <br>Necessary electrical and mechanical interlocking arrangements shall be provided as per scehmatic drawing to achieve operational functionality<br>All panels shall be with separate channels isolated from LT cable chambers for running of RS485 & other ELV cables for integration with EMS & IBMS. Switchgears and meters shall be with necessary communication ports for integration with BMS & EMS and Potential free contacts for BMS. All panel meters should be with RS485 ports for EMS integration. <br>All Multifunction meter shall be as per IEC 62053-21, class 1, having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be capable of integration with EMS Software<br>All opening parts of the panel shall be sealable. Panels shall be complete with Al bus bars, separate earth bus bar to be provided through out the length of the panel along with base chanel of suitable size, cable alleys as per requirement, complete, numbering, danger plate etc as required as per specifications and drawings. Current density for busbarsize shall be designed considering not more than 0.8 A/sq.mm for aluminium. The switchgear live parts shall be isolated with proper insulation material. All switchgears shall be with spreader links, operating knobs/handles, DIN rail provision for isolators with required cable alleys. The panel design shall be in accordance with IS & Kerala state norms. All panels shall be cable alleys and seperate bus bar compartments for easy terminations as per KSEI standards with proper clearances. <br>Incomer -<br>100A FP Isolator - 1 no<br>100A 433V, 25kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Surge Protection Device Class B+C/ Class 1+2 with HRC fuses for backup as per manufacturer standard, including copper cable connection between arrestor and fuses - 1 set<br>Outgoings<br>63A TP MCB - 1 no<br>32A TP MCB - 15 nos<br>

1

-

-

... More
od56934/2022_2023 : HVAC PANEL<br>Incomer -<br>500A FP Isolator - 1 no<br>500A 433V, 25kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Surge Protection Device Class B with HRC fuses for backup as per manufacturer standard, including copper cable connection between arrestor and fuses - 1 set<br>Outgoings<br>200A 25kA TP MCCB - 2 nos<br>100A 25kA TP MCCB - 4 nos<br>63A 16kA TP MCCB - 3 nos<br>

1

-

-

... More
od56935/2022_2023 : UPS MAIN PANEL<br>Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor / wall mounted, front operated MV panel board as per IS 8623, CPRI Certified, compartmentalised (minimum form 3b) complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. These panel should include surge arrester Class B or Class B+C/ Class 1+2 as per IEC 61643 (IP 20) with remote indication for defective arresters, arrester Spark Gap type to connect between Neutral and Earth.complete with back up fuse for SPD protection as per manufacturer standard. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. All switchgears shall be with with spreader links and rotary handle. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. <br>Necessary electrical and mechanical interlocking arrangements shall be provided as per scehmatic drawing to achieve operational functionality<br>All panels shall be with separate channels isolated from LT cable chambers for running of RS485 & other ELV cables for integration with EMS & IBMS. Switchgears and meters shall be with necessary communication ports for integration with BMS & EMS and Potential free contacts for BMS. All panel meters should be with RS485 ports for EMS integration. <br>All Multifunction meter shall be as per IEC 62053-21, class 1, having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be capable of integration with EMS Software<br>All opening parts of the panel shall be sealable. Panels shall be complete with Al bus bars, separate earth bus bar to be provided through out the length of the panel along with base chanel of suitable size, cable alleys as per requirement, complete, numbering, danger plate etc as required as per specifications and drawings. Current density for busbarsize shall be designed considering not more than 0.8 A/sq.mm for aluminium. The switchgear live parts shall be isolated with proper insulation material. All switchgears shall be with spreader links, operating knobs/handles, DIN rail provision for isolators with required cable alleys. The panel design shall be in accordance with IS & Kerala state norms. All panels shall be cable alleys and seperate bus bar compartments for easy terminations as per KSEI standards with proper clearances. <br>Incomer -<br>315A FP Isolator - 1 no<br>315A 433V, 36kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Surge Protection Device Class B with HRC fuses for backup as per manufacturer standard, including copper cable connection between arrestor and fuses - 1 set<br>Outgoings<br>40A 25kA TP Thermal Magnetic based MCCB - 1 no.<br>100A 25kA TP Thermal Magnetic based MCCB - 7 nos.<br>Multifunction meter as per IEC 62053-21, specified above including CTs and all accessories - 8 set<br>

1

-

-

... More
od56940/2022_2023 : SSB 1<br>Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor / wall mounted, front operated MV panel board as per IS 8623, CPRI Certified, compartmentalised (minimum form 3b) complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. These panel should include surge arrester Class B or Class B+C/ Class 1+2 as per IEC 61643 (IP 20) with remote indication for defective arresters, arrester Spark Gap type to connect between Neutral and Earth.complete with back up fuse for SPD protection as per manufacturer standard. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. All switchgears shall be with with spreader links and rotary handle. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. <br>Necessary electrical and mechanical interlocking arrangements shall be provided as per scehmatic drawing to achieve operational functionality<br>All panels shall be with separate channels isolated from LT cable chambers for running of RS485 & other ELV cables for integration with EMS & IBMS. Switchgears and meters shall be with necessary communication ports for integration with BMS & EMS and Potential free contacts for BMS. All panel meters should be with RS485 ports for EMS integration. <br>All Multifunction meter shall be as per IEC 62053-21, class 1, having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be capable of integration with EMS Software<br>All opening parts of the panel shall be sealable. Panels shall be complete with Al bus bars, separate earth bus bar to be provided through out the length of the panel along with base chanel of suitable size, cable alleys as per requirement, complete, numbering, danger plate etc as required as per specifications and drawings. Current density for busbarsize shall be designed considering not more than 0.8 A/sq.mm for aluminium. The switchgear live parts shall be isolated with proper insulation material. All switchgears shall be with spreader links, operating knobs/handles, DIN rail provision for isolators with required cable alleys. The panel design shall be in accordance with IS & Kerala state norms. All panels shall be cable alleys and seperate bus bar compartments for easy terminations as per KSEI standards with proper clearances. <br>Incomer -<br>500A FP Isolator - 1 no<br>500A 433V, 36kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Surge Protection Device Class B with HRC fuses for backup as per manufacturer standard, including copper cable connection between arrestor and fuses - 1 set<br>Outgoings<br>Multifunction meter as per IEC 62053-21, specified above including CTs and all accessories - 7 set<br>100A 25kA TP Thermal Magnetic Based MCCB - 5 nos<br>80A 25kA TP Thermal Magnetic Based MCCB - 1 no<br>63A 25kA TP Thermal Magnetic Based MCCB - 1 no<br>

1

-

-

... More
od56942/2022_2023 : SSB 2<br>Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor / wall mounted, front operated MV panel board as per IS 8623, CPRI Certified, compartmentalised (minimum form 3b) complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. These panel should include surge arrester Class B or Class B+C/ Class 1+2 as per IEC 61643 (IP 20) with remote indication for defective arresters, arrester Spark Gap type to connect between Neutral and Earth.complete with back up fuse for SPD protection as per manufacturer standard. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. All switchgears shall be with with spreader links and rotary handle. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. <br>Necessary electrical and mechanical interlocking arrangements shall be provided as per scehmatic drawing to achieve operational functionality<br>All panels shall be with separate channels isolated from LT cable chambers for running of RS485 & other ELV cables for integration with EMS & IBMS. Switchgears and meters shall be with necessary communication ports for integration with BMS & EMS and Potential free contacts for BMS. All panel meters should be with RS485 ports for EMS integration. <br>All Multifunction meter shall be as per IEC 62053-21, class 1, having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be capable of integration with EMS Software<br>All opening parts of the panel shall be sealable. Panels shall be complete with Al bus bars, separate earth bus bar to be provided through out the length of the panel along with base chanel of suitable size, cable alleys as per requirement, complete, numbering, danger plate etc as required as per specifications and drawings. Current density for busbarsize shall be designed considering not more than 0.8 A/sq.mm for aluminium. The switchgear live parts shall be isolated with proper insulation material. All switchgears shall be with spreader links, operating knobs/handles, DIN rail provision for isolators with required cable alleys. The panel design shall be in accordance with IS & Kerala state norms. All panels shall be cable alleys and seperate bus bar compartments for easy terminations as per KSEI standards with proper clearances. <br>Incomer -<br>315A FP Isolator - 1 no<br>315A 433V, 36kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Surge Protection Device Class B with HRC fuses for backup as per manufacturer standard, including copper cable connection between arrestor and fuses - 1 set<br>Outgoings<br>Multifunction meter as per IEC 62053-21, specified above including CTs and all accessories - 5 set<br>160A 25kA TP Thermal Magnetic Based MCCB - 1 no<br>100A 25kA TP Thermal Magnetic Based MCCB - 3 nos<br>63A 25kA TP Thermal Magnetic Based MCCB - 1 no<br>

1

-

-

... More
od62948/2022_2023 : DUMBWAITER PANEL<br>Incomer -<br>63A FP Modular Isolator - 1 no<br>63A 433V, 16kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Surge Protection Device Class B+C/ Class 1+2 with HRC fuses for backup as per manufacturer standard, including copper cable connection between arrestor and fuses - 1 set<br>Outgoings<br>32A 100mA FP RCBO - 2 nos<br>25A 30mA DP RCBO - 1 no<br>25A best conductivity extensible Al SPN bus bar<br>6A SP MCB - 4 nos<br>

1

-

-

... More
od62956/2022_2023 : AC PANEL 1<br>Incomer -<br>200A FP Isolator - 1 no<br>200A 433V, 25kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Surge Protection Device Class B+C/ Class 1+2 with HRC fuses for backup as per manufacturer standard, including copper cable connection between arrestor and fuses - 1 set<br>Outgoings<br>63A 16kA TP Thermal Magnetic Based MCCB - 4 nos<br>32A 16kA TP Thermal Magnetic Based MCCB - 2 nos<br>25A 16kA TP Thermal Magnetic Based MCCB - 4 nos<br>

1

-

-

... More
MV CABLE SUPPLY

-

-

-

... More
od59017/2022_2023 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br><br>3.5cx400sq.mm Al Cable<br><br><br>

262

-

-

... More
od59143/2022_2023 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>4cx400sq.mm Al Cable<br>

115

-

-

... More
od59292/2022_2023 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br><br>3.5cx300sq.mm Al Cable<br>

15

-

-

... More
od59293/2022_2023 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br><br>3.5cx240sq.mm Al Cable<br>

55

-

-

... More
od59294/2022_2023 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br><br>3.5cx185sq.mm Al Cable<br>

54

-

-

... More
od59308/2022_2023 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br><br>3.5cx70sq.mm Al Cable<br>

174

-

-

... More
od59311/2022_2023 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx95sq.mm Al Cable<br>

126

-

-

... More
od59331/2022_2023 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br><br>3.5cx50sq.mm Al Cable<br>

1159

-

-

... More
od59373/2022_2023 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br><br>3.5cx35sq.mm Al Cable<br>

130

-

-

... More
od65513/2022_2023 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br><br>4cx25sq.mm Al Cable<br>

753

-

-

... More
od65517/2022_2023 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br><br>4cx16sq.mm Al Cable<br><br>

323

-

-

... More
od65524/2022_2023 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br><br>4cx10sq.mm Al Cable<br>

5262

-

-

... More
od65527/2022_2023 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br><br>4x6sq.mm Al Cable<br>

646

-

-

... More
od65528/2022_2023 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>2cx6sq.mm Al Cable<br>

966

-

-

... More
od65537/2022_2023 : Supply and laying, including providing terminations for following PVC sheathed, unarmoured flexible copper conductor cable confirming to IS 7098 (part 1) ammended upto date for providing dedicated earthing. <br><br>1Cx50sq.mm Copper Flexible Cable (2XY) <br>

416

-

-

... More
od67954/2022_2023 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>12cx2.5sq.mm Cu Control Cable (2XFY)<br>

55

-

-

... More
od67975/2022_2023 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>2cx2.5sq.mm Cu Control Cable (2XFY)<br>

132

-

-

... More
MV CABLE LAYING

-

-

-

... More
7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

658

-

-

... More
7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm

435

-

-

... More
7.5.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm

25

-

-

... More
7.5.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185 sq. mm

11

-

-

... More
7.5.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 185 sq. mm and upto 400 sq. mm

9

-

-

... More
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

2550

-

-

... More
7.7.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

832

-

-

... More
7.7.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

31

-

-

... More
7.7.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

337

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

4624

-

-

... More
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

1018

-

-

... More
7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

12

-

-

... More
7.8.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

101

-

-

... More
7.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

33

-

-

... More
MV CABLE END TERMINATION

-

-

-

... More
9.1.31 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)

14

-

-

... More
9.1.30 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)

2

-

-

... More
9.1.29 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)

6

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

4

-

-

... More
9.1.24 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)

2

-

-

... More
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)

26

-

-

... More
9.1.21 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)

4

-

-

... More
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)

16

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

20

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

200

-

-

... More
od66976/2022_2023 : MV CABLE END TERMINATION<br>Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.<br><br>4 X 6 sq. mm (25mm)<br>

18

-

-

... More
9.1.1 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)

20

-

-

... More
od66995/2022_2023 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.<br><br>12cx2.5sq.mm Cu Control Cable (25mm) - with copper lugs<br>

8

-

-

... More
od67069/2022_2023 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.<br>2cx2.5sq.mm Cu Control Cable (19mm) - with copper lugs<br>

12

-

-

... More
od67452/2022_2023 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.<br><br>1Cx50sq.mm Copper Flexible Cable (2XY) - with copper lugs<br>

60

-

-

... More
od67944/2022_2023 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.<br><br>4 X 400 sq. mm (82mm)<br>

4

-

-

... More
od67945/2022_2023 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.<br><br>3½ X 70 sq. mm (38mm)<br>

4

-

-

... More
LIGHT FIXTURES

-

-

-

... More
od67870/2022_2023 : Supply of surface mountable, LED Batten Luminaire with Minimum 3600 Lumens output with System efficacy => 100 Lumen/Watts. Total wattage of fixture to be limited to 40W, Luminaire Housing shall be CRCA/aluminium with polycarbonate Diffuser with minimum IP20 protection. The Luminaire should be having Minimum 50,000 Burning hours with CRI ≥80 and CCT >= 5700K. The luminaire must have minimum 2KV surge protection integrated in driver, PF≥0.95,and total harmonic distortion THD≤10%. BIS approved , including all accesories as required .

176

-

-

... More
od67871/2022_2023 : Supply of surface mountable, LED Batten Luminaire with Minimum 1800 Lumens output with System efficacy => 100 Lumen/Watts. Total wattage of fixture to be limited to 20W, Luminaire Housing shall be CRCA/aluminium with polycarbonate Diffuser with minimum IP20 protection. The Luminaire should be having Minimum 50,000 Burning hours with CRI ≥80 and CCT >= 5700K. The luminaire must have minimum 2KV surge protection integrated in driver, PF≥0.95,and total harmonic distortion THD≤20%. BIS approved , including all accesories as required .

227

-

-

... More
od67875/2022_2023 : Supply of recess mountable, low height, LED downlight fixture with Minimum 1800 Lumens output with System efficacy => 100 Lumen/Watts. Total wattage of fixture to be limited to 18W, Luminaire Housing shall be aluminium die cast with polycarbonate Diffuser with minimum IP20 protection. The Luminaire should be having Minimum 50,000 Burning hours with CRI ≥80 and CCT >= 5700K. The luminaire must have minimum 2KV surge protection, PF≥0.95,and total harmonic distortion THD≤10%. BIS approved , including all accesories as required .

53

-

-

... More
od67877/2022_2023 : Supply of recess mountable, low height, LED downlight fixture with Minimum 1500 Lumens output with System efficacy => 100 Lumen/Watts. Total wattage of fixture to be limited to 15W, Luminaire Housing shall be aluminium die cast with polycarbonate Diffuser with minimum IP20 protection. The Luminaire should be having Minimum 50,000 Burning hours with CRI ≥80 and CCT >= 5700K. The luminaire must have minimum 2KV surge protection, PF≥0.95,and total harmonic distortion THD≤10%. BIS approved , including all accesories as required .

29

-

-

... More
od67882/2022_2023 : Supply of recess mountable, low height, LED downlight fixture with Minimum 1200 Lumens output with System efficacy => 100 Lumen/Watts. Total wattage of fixture to be limited to 12W, Luminaire Housing shall be aluminium die cast with polycarbonate Diffuser with minimum IP20 protection. The Luminaire should be having Minimum 50,000 Burning hours with CRI ≥80 and CCT >= 5700K. The luminaire must have minimum 2KV surge protection, PF≥0.95,and total harmonic distortion THD≤10%. BIS approved , including all accesories as required .

122

-

-

... More
od67893/2022_2023 : Supply of surface mountable, LED downlight fixture with Minimum 1500 Lumens output with System efficacy => 100 Lumen/Watts. Total wattage of fixture to be limited to 15W, Luminaire Housing shall be with polycarbonate cover for mounting with Diffuser and minimum IP20 protection. The Luminaire should be having Minimum 50,000 Burning hours with CRI ≥80 and CCT >= 5700K. The luminaire must have minimum 2KV surge protection, PF≥0.95,and total harmonic distortion THD≤10%. BIS approved , including all accesories as required .

27

-

-

... More
od67898/2022_2023 : Supply of recess mountable, low height, LED 2x2 light fixture with Minimum 3600 Lumens output with System efficacy => 100 Lumen/Watts. Total wattage of fixture to be limited to 36W, Luminaire Housing shall be CRCA with polycarbonate Diffuser with minimum IP20 protection. The Luminaire should be having Minimum 50,000 Burning hours with CRI ≥80 and CCT >= 5700K. The luminaire must have minimum 2KV surge protection, ripple content<5%, UGR<19, PF≥0.95,and total harmonic distortion THD≤10%. BIS approved , including all accesories as required .

55

-

-

... More
od67905/2022_2023 : Supply of recess mountable, low height, LED 2x2 light fixture with Minimum 3600 Lumens output with System efficacy => 100 Lumen/Watts. Total wattage of fixture to be limited to 36W, Luminaire Housing shall be CRCA with polycarbonate Diffuser with minimum IP20 protection. The Luminaire should be having Minimum 50,000 Burning hours with CRI ≥80 and CCT >= 5700K. The luminaire must have minimum 2KV surge protection, ripple content<5%, PF≥0.95,and total harmonic distortion THD≤10%. BIS approved , including all accesories as required .

312

-

-

... More
od67908/2022_2023 : Supply of Led Clean room Recessed mounded 2 X 2 Fittings with 3600Lumens output with System efficacy> 100 Lumen/Watt and Housing Shall be made of CRCA body and cover to ensure IK08 and minimum IP65 protection. The Luminaire should be having Minimum 50,000 Burning hours with CRI ≥80, Ripple <5% , and CCT >5700K, UGR<19. The luminaire should have minimum 2KV surge protection integrated in driver, PF≥0.95, Total harmonic distortion THD≤10% , bottom opening type. BIS approved including all accesories as required .

48

-

-

... More
od67936/2022_2023 : Supply, installation, testing and commisioning of LED Street Post Top with a minimum system lumen of 2800Lm with a nominal efficiency 90 lumen/watt. CCT of 5700K with CRI > 70. The housing should be of non-corrosive aluminum to with stand outdoor environments.PF > 0.95. Lifetime of 50K hours. Product should be suitable for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of minimum 08 . Under Voltage protection with Input Voltage Stress and EMI/EMC compliant . The Luminaire should have minmum 4KA Surge protection in the Luminaire BIS approved including all accesories as required .

4

-

-

... More
od67943/2022_2023 : Supply of Led Bulk head surface mountable with System efficacy> 90 Lumen/Watt and Housing Shall be made of strong body for outdoor application to avoid rusting and Polycarbonator diffuser to reduce glare with IP66 and IK09 Protection. The Luminaire should be having Minimum 50,000 Burning hours with CRI ≥80, (CCT) > 5700K. The luminaire should have minimum 2KV surge protection integrated in driver, PF≥0.95, Total harmonic distortion THD≤10% including all accesories as required .

100

-

-

... More
od67953/2022_2023 : Supply, fixing, testing and commissioning of 6 M octagonal poles of approved Make having top dia 70 mm, bottom dia 130 mm, Sheet thickness 3 mm, pitch circle dia (PCD) of 200 mm, Base plate dimentions 200mm length x 200mm bredth x 12mm thickness, EN8 grade Foundation bolts of size 4 x 20 mm dia, having bolt length of 600 mm. The Octagonal Poles shall be designed to withstand the maximum wind speed as per IS 875. The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The octagonal Poles shall have door of approximate 500 mm length at the elevation of 500 mm from the Base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connections. The door shall be flush with the exterior surface and shall have suitable locking arrangement. There shall also be suitable arrangement for the purpose of earthing. Material Octagonal Poles HT Steel Conforming to grade S355JO.Base Plate Fe 410 conforming to IS 226 / IS 2062Foundation Bolts EN.8 grade

7

-

-

... More
od67972/2022_2023 : Supply, fixing, testing and commissioning of 6 M octagonal poles of approved Make having top dia 70 mm, bottom dia 130 mm, Sheet thickness 3 mm, pitch circle dia (PCD) of 200 mm, Base plate dimentions 200mm length x 200mm bredth x 12mm thickness, EN8 grade Foundation bolts of size 4 x 20 mm dia, having bolt length of 600 mm. The Octagonal Poles shall be designed to withstand the maximum wind speed as per IS 875. The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The octagonal Poles shall have door of approximate 500 mm length at the elevation of 500 mm from the Base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connections. The door shall be flush with the exterior surface and shall have suitable locking arrangement. There shall also be suitable arrangement for the purpose of earthing. Material Octagonal Poles HT Steel Conforming to grade S355JO.Base Plate Fe 410 conforming to IS 226 / IS 2062Foundation Bolts EN.8 grade . The poles shall be hot dip galvanised as per IS 2629 / IS 2633 / IS 4759 standards with average coating thickness of 85 micron. The galvanizing shall be done in single dipping. The pole shall include one arm for fixing including supply of minimum 4500 lumen output LED Street light with >=100Lumen/Watt efficacy minimum, CRI >70 , CCT>5700 K , pf>0.95. The luminaire must have a IP66 protection and IK07 protection minimum, and minimum 2 kV internal surge protection. BIS certified including all accesories required for complete installation.

10

-

-

... More
od67974/2022_2023 : Supply, fixing, testing and commissioning of single arm bracket with mounting baseplate welded at the end, with anchors necessary to fix on the wall, 1 - 1.5m long for fixing including supply of minimum 4500 lumen output LED Street light with >=100Lumen/Watt efficacy minimum, CRI >70 , CCT>5700 K , pf>0.95. The luminaire must have a IP66 protection and IK07 protection minimum, and minimum 2 kV internal surge protection. BIS certified including all accesories required for complete installation

2

-

-

... More
od68526/2022_2023 : Supply of recess mountable, low height, LED 2x2 light fixture with Minimum 2800 Lumens output with System efficacy => 100 Lumen/Watts. Total wattage of fixture to be limited to 28W, Luminaire Housing shall be CRCA with polycarbonate Diffuser with minimum IP20 protection. The Luminaire should be having Minimum 50,000 Burning hours with CRI ≥80 and CCT >= 5700K. The luminaire must have minimum 2KV surge protection, ripple content<5%, PF≥0.95,and total harmonic distortion THD≤10%. BIS approved , including all accesories as required .

62

-

-

... More
od68527/2022_2023 : Supply of surface mountable, LED downlight fixture with Minimum 1200 Lumens output with System efficacy => 100 Lumen/Watts. Total wattage of fixture to be limited to 15W, Luminaire Housing shall be with polycarbonate cover for mounting with Diffuser and minimum IP20 protection. The Luminaire should be having Minimum 50,000 Burning hours with CRI ≥80 and CCT >= 5700K. The luminaire must have minimum 2KV surge protection, PF≥0.95,and total harmonic distortion THD≤10%. BIS approved , including all accesories as required .

24

-

-

... More
od70524/2022_2023 : Supply of surface mountable, LED 2x2 light fixture with Minimum 3200 Lumens output with System efficacy => 100 Lumen/Watts. Total wattage of fixture to be limited to 34W, Luminaire shall be with polycarbonate / CRCA outer cover for surface mounting and polycarbonate Diffuser with minimum IP20 protection. The Luminaire should be having Minimum 50,000 Burning hours with CRI ≥80 and CCT >= 5700K. The luminaire must have minimum 2KV surge protection, ripple content<5%, PF≥0.95,and total harmonic distortion THD≤10%. BIS approved , including all accesories as required .

84

-

-

... More
Fan fixtures

-

-

-

... More
od67980/2022_2023 : Supply of 5 star rated , BEE certified 26W, ceiling fan with BLDC motor,remote control for operation, with super enamelled copper wire winding, 230 V, single phase 50 HZ remote control operated fan with 1200mm sweep and 3 blades including all accessories as required with remote and standard length downrod all accesories required for complete installation

159

-

-

... More
od67983/2022_2023 : Supply of heavy duty exhaust fan of 450mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required, including all accessories as rquired for complete installation incluidng shutter etc complete as required.

10

-

-

... More
1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

1304

-

-

... More
1.44 : Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.

159

-

-

... More
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep

10

-

-

... More
3 x 80 kVA UPS in PRS Mode

-

-

-

... More
od69026/2022_2023 : Supply, installation,  and commissioning of 3 nos x 80kVA UPS, Three phase in and out with PRS configuration. UPS shall be indoor type (IP20) with surge protection system with SMF battery of reputed approved make, optimised Input should be pf >0.95 at full load, input THDi <3 % without use of any external filters, double conversion technology, 50Hz Three Phase, output 415V, 50Hz Three phase, BMS card for IBMS integration with modbus/TCP/IP communication protocol. It shall be 100% generator compatible, with Efficiency minimum 94% and in ECO mode should reach upto 99%. Output power factor should be >0.95 upto 1,after optimisation in normal mode of operation, and including all accessories etc as required.The system shall comply to EN 62040-1, IEC 61000-4, IEC 62040-2 and relevant IS & statutory standards. The acoustic noise at 1m of the system should be <75dB. The system shall be true online double - conversion DSP based UPS system and also UPS shall be with automatic bypass builtin. The system shall have IGBT rectifier and inverter. Each UPS shall be with communicable port compatiable with Modbus communcation/TCP/IP communication protocol, for integration of UPS with lBMS/EMS and all valuable paramaters of the UPS including battery cablinet temperature details should be obtainable from the UPS for integration. UPS shall be with parallel redundancy feature with expansion possible in the future. Each UPS should have minimum 15 min backup with seperate battery bank<br>80kVA standalone UPS - 3 Nos (in PRS mode of operation), Battery Circuit Breakers as required, MODBUS CARD with modbus/TCP/IP communication protocol -3 Nos, Battery -12V sealed maintenance free batteries (SMF VRLA) with required number of batteries to attain minimum 48,000VAh for providing 15 Minutes Back up for each UPS individually with Battery Accessories like battery rack, interconnecting cables, battery isolators etc. Battery calculation shall be provided before supply of the system.<br>

1

-

-

... More
3 kVA UPS (Single phase)

-

-

-

... More
od69054/2022_2023 : Supply installation, testing and commissioning of 3kVA single phase to single phase UPS with inbuilt battery backup, indoor (IP20) in stand alone configuration,true online double conversion DSP based UPS system, with min 10 min backup battery (Quanta/Exide) with, input pf>0.9, less input current consumption, with input 230V single phase, output 230V single phase , IGBT rectifier and IGBT inverter. It shall be 100% generator compatabile with efficiency > 90% and output power factor > 0.8 and including all accessories etc as required. The UPS system shall be with manual maintenance bypass switch facility.The system shall comply to IEC /EN 62040-1 and relevant IS standardand.The acoustic noise of the system should be less than 65dB, including all accesories required for complete installation as per requirement. <br>

1

-

-

... More
ENERGY MANAGEMENT SYSTEM

-

-

-

... More
od64575/2022_2023 : "Supply, installation, testing & integration of EMS. The Energy Management System shall be capable of integrating all digital panel and DIN rail meters, which are provided with RS485 communication port and MODBUS RTU Protocol. The Energy Management system shall assist the organization to comply with ISO 50001 & GRIHA standards. It shall be able to monitor data on real time basis i.e real time, trends based on real time and historical basis and multiple reports. Inclusive of Modules to access Realtime, Data History, Reports, Email, SMS and Device Configuration. with a Dash Board with critical information shall be provided along with alarm popup & acknowledge.There shall be no tag limitation, all the data from the device is monitored with any combination of devices and parameters for data analysis.Database Backup and Restore facility shall be provided in the software. The software shall provide graphical gauge representation of multiple parameters that can be selected by user at site. with Bar graph energy consumption representation on hourly basis, monthly basis, yearly basis, TOD basis. Shall come with provision for Multiple energy report generation including daily, weekly, monthly and yearly basis. Option of entry for no of slabs, slab rates, fixed charges, bill no. & date, tax percentage, special instructions, miscellaneous charges etc. (Liscence shall considered for monitoiring of all parameters of 70 digital meters with RS485 port with provision for adding in future if required) (L&T SmartComm or equivalent)<br>"<br>The software shall be installed in seperate PC. Static IP to be shared with GRIHA portal for two way communication. Price shall be quoted inclusive of instllation and commisiong and providing technical support and training to client maintenance staff. Standard features and reports, graphs and all other services shall be included in the EMS software alongwith the liscence. All features of the softawre as per manufacturer standard to be availiable upon installation and operation. The system shall be includive of Webview (WebBrowser Based Monitoring). The rate shall be inclusive of Installation charges for EMS installations, integration charges and all charges for complete installation of componets, installation of switches, meter configuration, tagging, software settingup, controllers, software etc, calibration, installation, integration and commisioning as per satisfaction of client and integrating as required<br>Supply instllation, testing and commisioning of PC server system with following minimum specification, the processor shall be minimum Intel i5, 8 core CPU (3 GHz or better), 64 bit, 8 GB RAM, DVD ROM, 1TB HDD ( Approx. 2 year data saving), USB PORT (2 Nos.), NIC (2 Nos. – 4 ports), 2GB graphics card, 24” inch full LED monitor, USB Keyboard, colour A4 printer with printer software and initial ink, USB Mouse three button & scrolling and all other accesories required which is required for the proper functioning of the system alongwith workstation furniture for installing the sytem complete as required. The software installed in the system shall be as below but not limited to the same - MS Office 2010, Windows 10, 64 bit, best class Anti-Virus software with 2 year liscence, Adobe Reader and all other basic softwares as required for proper functioning of the system and all other accesories as required for PC server system.<br>

1

-

-

... More
od64697/2022_2023 : Supply instllation, testing and commisioning of PC server system with following minimum specification, the processor shall be minimum Intel i5, 8 core CPU (3 GHz or better), 64 bit, 8 GB RAM, DVD ROM, 1TB HDD ( Approx. 2 year data saving), USB PORT (2 Nos.), NIC (2 Nos. – 4 ports), 2GB graphics card, 24” inch full LED monitor, USB Keyboard, colour A4 printer with printer software and initial ink, USB Mouse three button & scrolling and all other accesories required which is required for the proper functioning of the system alongwith workstation furniture for installing the sytem complete as required. The software installed in the system shall be as below but not limited to the same - MS Office 2010, Windows 10, 64 bit, best class Anti-Virus software with 2 year liscence, Adobe Reader and all other basic softwares as required for proper functioning of the system and all other accesories as required for PC server system.<br>

1

-

-

... More
od64710/2022_2023 : Supply installation, testing and commisioning of 1 /port RS485 Serial to Modbus TCP/IP Communication Gateway including all assecories as required<br>

5

-

-

... More
od64732/2022_2023 : "Supply installation, testing and commissioning of 6 Port Non-PoE Network switch with below specifications as minimum or higher as required and with all the accessories required to complete the system.<br> - Ports 12 x 10/100/1000 Mbps<br> - Standards - IEEE 802.3i/802.3u/ 802.3ab/802.3x<br> -Type - Unmanaged<br>- Mount Type - Wall Mount/ Table Top / Rack mount"<br>

1

-

-

... More
od64804/2022_2023 : Supply installation, testing and commissioning of 12 Port unloaded patch panel with rack mounting accessories<br>

1

-

-

... More
od64999/2022_2023 : Supply installation, testing and commissioning of CAT6 Information outlet for above patch panels<br>

14

-

-

... More
od65003/2022_2023 : Supply installation, testing and commissioning of CAT6 Patch Cords - 1 Meter<br>

7

-

-

... More
od65039/2022_2023 : Supply installation, testing and commissioning of 4U wall mount Network Rack with all the necessary accessories such as wall mount kit, fan, PDU etc. to complete the system.<br>

1

-

-

... More
od65045/2022_2023 : Supply, laying, tieying/clamping, testing and commisioning of Shielded data cable, copper with low impedance, 0.5mm capable to transmit the data of energy meter's serial port RS485 including all accessories as required<br>

823

-

-

... More
od65062/2022_2023 : Providing termination for RS485 cable with RS485 connectors, crimpring, testing complete as required<br>

122

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

403

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

36

-

-

... More
1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable

72

-

-

... More
od65140/2022_2023 : "Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching<br>(75 cm deep)and re-filling etc as required"<br>32mm<br>

420

-

-

... More
INTERNAL WIRING

-

-

-

... More
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

863

-

-

... More
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

4

-

-

... More
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

712

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

6185

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

6341

-

-

... More
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire

2588

-

-

... More
1.14.7 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire

2114

-

-

... More
1.14.8 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 4 sq. mm + 2 X 4 sq. mm earth wire

863

-

-

... More
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

1246

-

-

... More
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

1174

-

-

... More
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm

479

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

120

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

320

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

280

-

-

... More
1.40 : Providing and fixing plain 16/0.20 mm (0.50 sqmm) twin circular flexible FRLS PVC insulated, PVC sheathes copper cable direct on the wall with PVC clips etc as required.

159

-

-

... More
1.39 : Providing and fixing plain 16/0.20mm (0.50sqmm) twin flat flexible, FRLS PVC insulated, copper cable, in PVC sleeve of suitable size on the floor / wall, or side of the table / door etc. as required.

16

-

-

... More
1.43 : Providing and fixing extra conduit down rod of 20 mm dia, 2X10 cm length wiring with 2 X1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)

531

-

-

... More
1.49 : Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.

1586

-

-

... More
od58364/2022_2023 : Supply and clamping the following size of corrugated pvc fiexible conduit with necessary locking ring and check nut at termination pointed using suitable size GI saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc.as required<br>25mm dia <br>

120

-

-

... More
od58365/2022_2023 : Supply and clamping the following size of corrugated pvc fiexible conduit with necessary locking ring and check nut at termination pointed using suitable size GI/painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc.as required<br>20mm dia <br><br>

907

-

-

... More
od70854/2022_2023 : Wiring for Staircase Light Point (UPS POWERED)<br>Wiring for stair case light points with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in and including surface / recessed medium class PVC conduit and all acessories required for complete installation etc , with 1 way modular switch, modular plate, suitable GI box medium class PVC conduit and all acessories required etc and earthing the point with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required and instructed by engineer in charge/consultant. (*Note - Staircase light point shall be controlled by a single switch located inside fire command room in ground floor as per latest fire norms, this switch should turn on the first light point of stair in GF and remaining staircase lights shall be considered in loop wiring. The staircase wiring shall be UPS powered for emergency backup)<br><br>One light point controlled by one way switch <br>

3

-

-

... More
SWITCH & SOCKETS

-

-

-

... More
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

76

-

-

... More
1.27.5 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)

60

-

-

... More
1.28.2 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module

47

-

-

... More
1.28.5 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module

12

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

141

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

180

-

-

... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

357

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

108

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

422

-

-

... More
od58369/2022_2023 : Supplying and fixing suitable size GI box with modular plate and cover in FRLSont<br>on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular<br>socket outlet and 15/16 amps modular switch, connection etc. as required

453

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

14

-

-

... More
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

14

-

-

... More
DBs AND COMPONENTS

-

-

-

... More
2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door

1

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

9

-

-

... More
2.3.4 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door

1

-

-

... More
2.5.1 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (4 + 12), Double door

3

-

-

... More
2.5.2 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (4 + 24), Double door

11

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

851

-

-

... More
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole

11

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

24

-

-

... More
2.10.5 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral

22

-

-

... More
od58393/2022_2023 : Supplying and fixingfollowing rating, 415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.<br><br>40A Triple pole<br>

27

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

159

-

-

... More
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

40

-

-

... More
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

1

-

-

... More
2.15.1 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

9

-

-

... More
od58406/2022_2023 : "Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB),<br>having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required."<br>40A<br>

40

-

-

... More
od58412/2022_2023 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.<br>25A<br>

1

-

-

... More
od58413/2022_2023 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker with overload protection (RCBO), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.<br>16A<br>

9

-

-

... More
2.25 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.

32

-

-

... More
2.5.3 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)12 way (4 + 36), Double door

2

-

-

... More
od70894/2022_2023 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator). Conforms to IS 8623-1 & 3, IEC 61439-1 & 3, IK 09, double door DBs, CRCA sheet steel, powder coated, with insulated phase bus-bars, neutral bar/s with shroud/s, earth bar/s, sticking saddles, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identification labels, IP 43 rated including all acessories and making good damages as required<br>4 way (8 + 12), Double door<br>

25

-

-

... More
od70902/2022_2023 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator). Conforms to IS 8623-1 & 3, IEC 61439-1 & 3, IK 09, double door DBs, CRCA sheet steel, powder coated, with insulated phase bus-bars, neutral bar/s with shroud/s, earth bar/s, sticking saddles, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identification labels, IP 43 rated including all acessories and making good damages as required<br>6 way (8 + 18), Double door<br>

23

-

-

... More
od70910/2022_2023 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator). Conforms to IS 8623-1 & 3, IEC 61439-1 & 3, IK 09, double door DBs, CRCA sheet steel, powder coated, with insulated phase bus-bars, neutral bar/s with shroud/s, earth bar/s, sticking saddles, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identification labels, IP 43 rated including all acessories and making good damages as required<br>

1

-

-

... More
od71203/2022_2023 : Supplying and fixing following rating, three pole, 415 V, modular isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.<br><br>40A

4

-

-

... More
od71473/2022_2023 : Supplying and fixingfollowing rating, 415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.<br>63A Triple pole<br>

3

-

-

... More
od71512/2022_2023 : Supplying and fixing FP CRCA sheet steel enclosure on surface/ recess with provision to mount MCB/Isolator/RCCB/RCBO and other four pole modular devices complete with connections, testing and commissioning etc. as required. Conforms to IS 8623-1 & 3, IEC 61439-1 & 3<br>

13

-

-

... More
od71518/2022_2023 : Supplying and fixing outdoor enclosure with openable door made of Thermoplastic Glass Fiber Reinforced Polycarbonate (PC) with an Ingress Protection IP 65 along with following rating four pole 300mA RCBO, surface mounted alongwith all accesories complete with connections, testing and commissioning etc. as required, knockouts for cable entry with all acessories, DIN rail etc complete as required, complete with connections, testing and commissioning etc. as required.<br>63A <br><br><br>

5

-

-

... More
od71525/2022_2023 : Supplying and fixing outdoor enclosure with openable door made of Thermoplastic Glass Fiber Reinforced Polycarbonate (PC) with an Ingress Protection IP 65 along with following rating four pole 300mA RCBO, surface mounted alongwith all accesories complete with connections, testing and commissioning etc. as required, knockouts for cable entry with all acessories, DIN rail etc complete as required, complete with connections, testing and commissioning etc. as required.<br><br>100A <br>

1

-

-

... More
Isolator With Enclosure

-

-

-

... More
od58431/2022_2023 : Isolator With Enclosure<br>"Supply and fixing of SDF isolators in Sheet enclosures of following ratings, 415, with provision for cable glanding of cables as per schematic layout with Terminal Shrouds on both sides and Phase Barriers included. The enclosure should be of Sheet Steel constuction powder coated, spacious design for easy cable glanding and connection to terminals,conforming to IEC 60947-3, IS/IEC 60947-3, suitable for Cylindrical/DIN fuse-link inclusive of fuse links with Door interlock & padlock facility, including spreader links, handle and all accesoires including mounting on wall and making clear all damages complete with testing and commissioning etc. as required.<br>"<br>160A FP Isolator with enclosure<br>

1

-

-

... More
od58434/2022_2023 : "Supply and fixing of SDF isolators in Sheet enclosures of following ratings, 415, with provision for cable glanding of cables as per schematic layout with Terminal Shrouds on both sides and Phase Barriers included. The enclosure should be of Sheet Steel constuction powder coated, spacious design for easy cable glanding and connection to terminals,conforming to IEC 60947-3, IS/IEC 60947-3, suitable for Cylindrical/DIN fuse-link inclusive of fuse links with Door interlock & padlock facility, including spreader links, handle and all accesoires including mounting on wall and making clear all damages complete with testing and commissioning etc. as required.<br><br>63A FP Isolator with enclosure<br><br>

14

-

-

... More
od58435/2022_2023 : "Supply and fixing of SDF isolators in Sheet enclosures of following ratings, 415, with provision for cable glanding of cables as per schematic layout with Terminal Shrouds on both sides and Phase Barriers included. The enclosure should be of Sheet Steel constuction powder coated, spacious design for easy cable glanding and connection to terminals,conforming to IEC 60947-3, IS/IEC 60947-3, suitable for Cylindrical/DIN fuse-link inclusive of fuse links with Door interlock & padlock facility, including spreader links, handle and all accesoires including mounting on wall and making clear all damages complete with testing and commissioning etc. as required.<br><br>40A FP Isolator with enclosure<br><br><br>

4

-

-

... More
od58437/2022_2023 : "Supply and fixing of SDF isolators in Sheet enclosures of following ratings, 415, with provision for cable glanding of cables as per schematic layout with Terminal Shrouds on both sides and Phase Barriers included. The enclosure should be of Sheet Steel constuction powder coated, spacious design for easy cable glanding and connection to terminals,conforming to IEC 60947-3, IS/IEC 60947-3, suitable for Cylindrical/DIN fuse-link inclusive of fuse links with Door interlock & padlock facility, including spreader links, handle and all accesoires including mounting on wall and making clear all damages complete with testing and commissioning etc. as required.<br><br>32A FP Isolator with enclosure<br><br>

20

-

-

... More
INDUSTRIAL SOCKETS

-

-

-

... More
od58442/2022_2023 : INDUSTRIAL SOCKETS<br>Supplying, installation, testing & commisioning following surface mounting insulated plug and socket arrangement, power socket in independent position housed in suitable enclosure with high ingress protection (IP 64) with DIN rail for providing MCB protection of suitable rating including MCB supply and installation , with safe entry for cable and straight plugs with instant locking with screwless clamping, with direct connection with universal screws all terminals facing the same direction with large body size making wiring easy, maximum safety with elongated earth pin disconnected last on removal with direct mounting onto base and maximum cable grip with screwless clamp giving necessary connection as required including all acessories as required for complete installation and as directed by engineer in charge/consultant, and making good any damages made during installation complete with testing and commissioning etc. as required... <br><br>16 A, 3 Pin + 16A DP MCB <br>

6

-

-

... More
od58445/2022_2023 : Supplying, installation, testing & commisioning following surface mounting insulated plug and socket arrangement, power socket in independent position housed in suitable enclosure with high ingress protection (IP 64) with DIN rail for providing MCB protection of suitable rating including MCB supply and installation , with safe entry for cable and straight plugs with instant locking with screwless clamping, with direct connection with universal screws all terminals facing the same direction with large body size making wiring easy, maximum safety with elongated earth pin disconnected last on removal with direct mounting onto base and maximum cable grip with screwless clamp giving necessary connection as required including all acessories as required for complete installation and as directed by engineer in charge/consultant, and making good any damages made during installation complete with testing and commissioning etc. as required... <br><br>32 A, 3 Pin + 32A DP MCB <br>

1

-

-

... More
od58458/2022_2023 : Supplying, installation, testing & commisioning following surface mounting insulated plug and socket arrangement, power socket in independent position housed in suitable enclosure with high ingress protection (IP 64) with DIN rail for providing MCB protection of suitable rating including MCB supply and installation , with safe entry for cable and straight plugs with instant locking with screwless clamping, with direct connection with universal screws all terminals facing the same direction with large body size making wiring easy, maximum safety with elongated earth pin disconnected last on removal with direct mounting onto base and maximum cable grip with screwless clamp giving necessary connection as required including all acessories as required for complete installation and as directed by engineer in charge/consultant, and making good any damages made during installation complete with testing and commissioning etc. as required... <br><br>32 A, 5 Pin + 32A FP MCB<br>

7

-

-

-

-

-

... More
od58473/2022_2023 : MCCB:<br>Supply, fixing, testing and commisioning of following rating, breaking capacity and pole, MCCB in existing Vertical Distribution Board with spredear links, terminal connections and all accesories as required making all necessary connections etc as required and instructed by engineer in charge/consultant complete with testing and commissioning etc. as required..<br>63 / 80 / 100 Amp (16-18)kA FP MCCB <br>

15

-

-

... More
od71484/2022_2023 : Supply, fixing, testing and commisioning of following rating, breaking capacity and pole, MCCB in existing Vertical Distribution Board with spredear links, terminal connections and all accesories as required making all necessary connections etc as required and instructed by engineer in charge/consultant complete with testing and commissioning etc. as required.<br><br>40 Amp (16-18)kA FP MCCB <br>

1

-

-

... More
SURGE ARRESTOR FOR DBs

-

-

-

... More
od70675/2022_2023 : Supply, installation, testing and commisioning of pluggable type surge arrester in suitable enclosure Class B+C/ Type 1+2 as per IEC 61643 -11 for lightning current equipotential bonding. Modular connectable arrestor with dynamic cut-off unit and visual status display for each cartridge. It should be included Locking mechanism with vibration protection and voltage keying for safe operation of the device. Nominal voltage -230V 50Hz, type single MOV with built in thermal fuse and cooling gel(L to N) & spark gap encapsulated / non exhausting (N to E) . Lightning Impulse Current - (10/350µ sec) for Line to Neutral & (10/350µ sec) for Neutral to Earth, Nominal discharge current- (8/20µ sec) for Line to Neutral & (8/20µ sec) for Neutral to Earth, Total Max discharge current - (8/20µ sec), Voltage protection level (L to N) & (N to E), Operating temp -40º to +80ºC should be as minimum as per IS standards with response time <25 nano sec (L to N), < 100 nano sec (N to E) DIN rail mounting type etc The arrestor shall be DIN rail mounting type etc complete with back up fuse as required and as per manaufacturer standard with enclosure for mounting the SPD near the DB, including copper cables for connection between SPD and DB incomer such that the cable length should be within 0.5m, including all accesories complete as required, testing and commisioning making good the damages<br>

11

-

-

... More
od70923/2022_2023 : SURGE ARRESTOR FOR DBs<br>Supply, installation, testing and commisioning of pluggable type surge arrester in suitable enclosure Class B+C/ Type 1+2 as per IEC 61643 -11 for lightning current equipotential bonding. Modular connectable arrestor with dynamic cut-off unit and visual status display for each cartridge. Nominal voltage -230V 50Hz, type single MOV with built in thermal fuse and cooling gel(L to N) & spark gap encapsulated / non exhausting (N to E) . Total Lightning Impulse Current shall be as per IS standards (10/350µ sec) for Line to Neutral & (10/350µ sec) for Neutral to Earth, Total Nominal discharge current- shall also be as per IS standards for Line to Neutral & (8/20µ sec) for Neutral to Earth, Total Max discharge current & voltage protection level - should be minmum as per IS standards (8/20µ sec). Response time <25 nano sec (L to N), < 100 nano sec (N to E). The arrestor shall be DIN rail mounting type etc complete with back up fuse as required and as per manaufacturer standard with enclosure for mounting the SPD near the DB, including copper cables for connection between SPD and DB incomer such that the cable length should be within 0.5m, including all accesories complete as required, testing and commisioning making good the damages<br>

65

-

-

... More
MICROWAVE SENSORS

-

-

-

... More
od58373/2022_2023 : MICROWAVE SENSORS<br>"Supplying,installation,testing and commissioning of Microwave technology based occupancy sensor with day light dimming(lighting level shall be regulated as per availability of natural day light in an area along with occupancy detection.) having high preformance and high sensitivity motion detection of fine even fine minute finger movements such as typing, regulating programmable type, suitable for connected load upto 10Amp , for mounting height up to 2.8 - 3 mtr and for 6-8 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete with testing and commissioning etc. as required.<br>

88

-

-

... More
TERMINATION BOXES

-

-

-

... More
od70757/2022_2023 : TERMINATION BOXES<br>Supply, installation, testing and commisioning of self extinguishing, weatherproof cabinets suitaible tfor outdoor application (IP 65, IK 09) with reversible door and cabinet with terminals for looping of cables and rail for fixing modular isolator along with 16/25A DP isolator including all connections and interconnections as required for outdoor application as instructed by engineer in charge.(For bollards, postops etc)<br>

2

-

-

... More
CAR CAHRGING EV STATION

-

-

-

... More
od70773/2022_2023 : CAR CHARGING EV STATION<br>Supply, installation, testing and commissioning of single phase 230V, 32A AC Type-2 7kW car charging socket suitable to charge 1 car with 1 plug with residual current detection of 30mA, earth pin detection and indication, emergency shutdown, LED indicators with simultaneous charging including 4 meter plug cable with power and energy monitoring using LCD display. The enclosure shall be IP66 wall mountable as per CE compliance as required as per standards including all accessories required for complete installation and commissioning as required by the engineer in charge.<br>

1

-

-

... More
LIGHTNING PROTECTION

-

-

-

... More
od67738/2022_2023 : Supply, installation and testing of 8 mm Aluminum Round Conductor complete as specified in drawing & Meets the requirements of DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305) including all accessories as required and as instructed by engineer in charge <br>

1270

-

-

... More
od67751/2022_2023 : Supply and installation of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. including all accessories as required and as instructed by engineer in charge <br>

272

-

-

... More
od67752/2022_2023 : Supply and installation of Roof conductor holder for parapet/down comers- Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance including all accessories as required and as instructed by engineer in charge <br>

747

-

-

... More
od67776/2022_2023 : Supply and installation of cross universal connector: for T and cross connection, to route vertical down conductor /mesh formation made of hot dipped galvanised iron with necessary screws etc as required. Installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts and all other accesories as required as per the area to be fixed shall be considered alongwith the same<br>

70

-

-

... More
od67789/2022_2023 : Supply, installation and testing of maintenance free earthing system with UL Listed & CPRI tested maintenance free, Low carbon copper coated earth rod of 3 metre electrode having diameter of 14.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 with self-coupling peg & bore arrangement with fault current withstand capability of 20 KA rms value for 1 second and I peak of 50 KA & provided with universal clamp made of SS to connect rod with flat conductor, Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested The material shall be mineral inert to sub soil and shall not pollute the environment and non corrosive to earth rod. The material should have a resistivity less than 0.2 Ωm. It should be free from hazardous substances The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system <br>

5

-

-

... More
od67790/2022_2023 : Supply and installation of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric.including all accessories as required and as instructed by engineer in charge.<br>

80

-

-

... More
od67791/2022_2023 : Supply and installation of flat conductor holder suitable Installed with 2 hexagonal bolts. including all accessories as required and as instructed by engineer in charge <br>

80

-

-

... More
od67792/2022_2023 : Supply and installation of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal including all accessories as required and as instructed by engineer in charge <br>

20

-

-

... More
od67793/2022_2023 : Supply, installation and testing of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor shall be of Hot Dipped & Cross sectional area of 90mm square According to DIN EN 50164-2 (VDE 0185 part 202) Meets the requirement of VDE0185/305(IS-IEC 62305) Zinc coating: 500 g/m square (Approx :70 micron coating) Should be tested and used exclusively for lightning protection earthing system and ring equipotential bonding. including all accessories as required and as instructed by engineer in charge <br>

341

-

-

... More
od67794/2022_2023 : Supply, installation and testing of Lightnig counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6. including site programing, enclosure for mounting and including all accessories as required and as instructed by engineer in charge<br>

1

-

-

... More
od67795/2022_2023 : Supply, installation and testing of Test Joint (Folding Clamp) made of SS,suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer within enclosed box suitable for opening including all accessories as required and as instructed by engineer in charge<br>

20

-

-

... More
od67796/2022_2023 : Supply and installation of expansion piece with parallel/T connectors (2 nos), For equalising temperature related length changes. To be used on conductors length over 20 meters. For round conductor. T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Conforms to the requirements according to DIN VDE 0185-305 (IS-IEC 62305)(2nos/expansion piece) including all accessories as required and as instructed by engineer in charge <br>

39

-

-

... More
od67821/2022_2023 : Supply, installation and testing of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 16mm rod tapered to 10 mm aluminium rod :Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202).Meets the requirement of VDE0185/305(IS/IEC 62305) 4Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load including all accessories as required and as instructed by engineer in charge. System shall consist of Fang Fix with base and clamp, on the top air terminal is erected. Fang fix clamp made of SS, lightning tested for 100 KA 10/350 micro sec waveform. 16 KG stone of 365 mm diameter, high level of stability.Quick and easy mounting of interception rod using anchors, 16 KG stone of 365 mm diameter, high level of stability. Quick and easy mounting of interception rod using anchors.Concrete, frost-resistant, can be stacked<br>

2

-

-

... More
od67822/2022_2023 : Supply and installation of holder for for metal roof Stainless steel base with Polyamide Conductor holder top min 8.5mm diameter slot With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance including all accessories as required and as instructed by engineer in charge <br><br>

251

-

-

... More
EARTHING PROTECTION

-

-

-

... More
od69264/2022_2023 : Supply, installation and tesing of 1200mmx1200mmx12mm CI plate electrode earth station conforming to IS:3043-1987 / NEC / IEE complete with brick masonry chamber, heavy duty CI cover, CI frame, GI watering pipe of 50 mm dia with funnel having 20G GI wire mesh etc. The CI cover (heavy duty) frame/ chamber shall be of 450mm x 450mm size. CI manhole cover with frame shall be painted with bitumastic paint, identification of earthpit with yellow paint below the chamber cover, mixtures of charcoal & common salt around electrode including digging of pit up to permanent moisture level but not less than 3 metre depth and back filling. ( value of earth resistance should be less than 1 ohm )<br>

14

-

-

... More
5.6 : Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

6

-

-

... More
5.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required

6

-

-

... More
od69374/2022_2023 : Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling ,including necessary clamps and bolts etc and all accessories as required for complete installation as instructed by engineer in charge/consultant. <br>25x3 mm Cu strip tinned at the point of contact<br>

274

-

-

... More
od69375/2022_2023 : Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling ,including necessary clamps and bolts etc and all accessories as required for complete installation as instructed by engineer in charge/consultant. <br>32x6 mm Cu strip tinned at the point of contact<br>

273

-

-

... More
od70516/2022_2023 : Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling ,including necessary clamps and bolts etc and all accessories as required for complete installation as instructed by engineer in charge/consultant. <br>Copper wire No.8 SWG <br>

2329

-

-

... More
od70517/2022_2023 : Supply and laying the following sizes of strips on cable tray/wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant. <br>Copper wire No.10 SWG <br>

2270

-

-

... More
od70518/2022_2023 : Supply and laying the following sizes of strips on cable tray/wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant. <br>25x3mm Cu strips tinned at the point of contact<br>

2075

-

-

... More
od70519/2022_2023 : Supply and laying the following sizes of strips on cable tray/wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant. <br>32x6 mm Cu strip tinned at the point of contact<br>

90

-

-

... More
od70520/2022_2023 : Supply and laying, including providing terminations for following PVC sheathed, unarmoured flexible copper conductor cable confirming to IS 7098 (part 1) ammended upto date for providing dedicated earthing. <br><br>1Cx16sq.mm Copper Flexible Cable (2XY) <br>

154

-

-

... More
od70521/2022_2023 : Supply and laying, including providing terminations for following PVC sheathed, unarmoured flexible copper conductor cable confirming to IS 7098 (part 1) ammended upto date for providing dedicated earthing. <br><br>1Cx6sq.mm Copper Flexible Cable (2XY) <br>

1463

-

-

... More
od70522/2022_2023 : Supply and laying, including providing terminations for following PVC sheathed, unarmoured flexible copper conductor cable confirming to IS 7098 (part 1) ammended upto date for providing dedicated earthing. <br><br>1Cx50sq.mm Copper Flexible Cable (2XY) <br>

150

-

-

... More
od70523/2022_2023 : Providing coil/spring earthing using 2 runs of 8 SWG, Cu wire for street light pole etc. Cu wire buried to a minimum depth of 1.5m, with excavation, refilling and connecting Cu wire to pole using bolt and nut complete including all accessories required.(For street lighting poles etc)<br>

20

-

-

... More
5.10 : Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.

65

-

-

... More
5.20 : Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.

5

-

-

... More
CABLE TRAYS

-

-

-

... More
od70487/2022_2023 : Supply and fixing of strip galvanised Perforated Cable tray confirming to IEC-61537 with galvanized 8mm threaded support system with 2 nos of anchor bolts with threaded rods from ceiling with cross channels of maximum width as per tray size bolted to it for supporting perforated cable tray and other accessories as required. The Tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461 .The trays should be tested for a max. safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standardand and safety factor as per IEC & ISO standards.Cable tray routing shop drawing shall got approved from Consultant before execution at site. Supports shall be placed at intervals as per loading of the tray but minimum interval of 100cm to be kept between the supports . Fabrication works by welding, cutting, bendng etc required for reducing of shape, size, providing bends and cross connections or offseting of cable trays as per site requirement shall also be considered in this scope without any additional cost in a proffesional manner. The cut areas shall be repainted with anticorrosive material to avoid rusting. All other assecories as required for complete installations shall be considered in this scope of work " 100mm width x 60mm Height

1064.8

-

-

... More
od70488/2022_2023 : "Supply and fixing of strip galvanised Perforated Cable tray confirming to IEC-61537 with galvanized 8mm threaded support system with 2 nos of anchor bolts with threaded rods from ceiling with cross channels of maximum width as per tray size bolted to it for supporting perforated cable tray and other accessories as required. The Tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461 .The trays should be tested for a max. safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standardand and safety factor as per IEC & ISO standards.Cable tray routing shop drawing shall got approved from Consultant before execution at site. Supports shall be placed at intervals as per loading of the tray but minimum interval of 100cm to be kept between the supports . Fabrication works by welding, cutting, bendng etc required for reducing of shape, size, providing bends and cross connections or offseting of cable trays as per site requirement shall also be considered in this scope without any additional cost in a proffesional manner. The cut areas shall be repainted with anticorrosive material to avoid rusting. All other assecories as required for complete installations shall be considered in this scope of work " 150mm width x 60mm Height

1268.73

-

-

... More
od70489/2022_2023 : Supply and fixing of Cable Ladder trays confirming to IEC-61537.The Cable Ladder shall be made of 1.5mm thick sheet steel including supply and providing galvanized 8mm (200 - 300mm wide trays) & 10mm (400-600mm wide trays) threaded support system with 2 nos of dropp in anchor bolts from ceiling with heavy duty profile rail of suitable size as per tray width.The cable Ladder shall be galvanized for corrosion protection confirming to ISO 1461 .The cable ladder should be tested for safe working load of 225 Kg/ Mtr (for 400 - 600mm wide tray) & 140 Kg / Mtr (for 200 - 300mm wide tray) with a span distance of 2 Mtr the deflection should be within the limits as per standard. The cable ladder shall be supplied in standard length of 3000 mm. The rung size shall be of 30x15mmm size suitable for fixing the cable clamps, the space between the rungs shall be 300mm. Cable tray routing shop drawing shall got approved from Consultant before execution at site. Supports shall be placed at intervals as per loading of the tray but minimum interval of 60cm to be kept between the supports . Fabrication works by welding, cutting, bendng etc required for reducing of shape, size, providing bends and cross connections or offseting of cable trays as per site requirement shall also be considered in this scope without any additional cost in a proffesional manner. The cut areas shall be repainted with anticorrosive material to avoid rusting. All other assecories as required for complete installations shall be considered in this scope of work. Cable tray suspenders shall be the same make as the tray manufacturer including Wall and support brackets With flange-welded head plate Steel St Length 610mm suitable for 600mm ladder, Suspended support from ceiling With flange-welded head plate Steel St 50x50x400 for 450mm tray and galvanized 8mm threaded support system with 2 nos of dropp in anchor bolts, with heavy duty profile rail for remaining cable tray sizes" 200mm width x 50mm Height

2045.81

-

-

... More
od70493/2022_2023 : "Supply and fixing of Cable Ladder trays confirming to IEC-61537.The Cable Ladder shall be made of 1.5mm thick sheet steel including supply and providing galvanized 8mm (200 - 300mm wide trays) & 10mm (400-600mm wide trays) threaded support system with 2 nos of drops in anchor bolts from ceiling with heavy duty profile rail of suitable size as per tray width.The cable Ladder shall be galvanized for corrosion protection confirming to ISO 1461 .The cable ladder should be tested for safe working load of 225 Kg/ Mtr (for 400 - 600mm wide tray) & 140 Kg / Mtr (for 200 - 300mm wide tray) with a span distance of 2 Mtr the deflection should be within the limits as per standard. The cable ladder shall be supplied in standard length of 3000 mm. The rung size shall be of 30x15mmm size suitable for fixing the cable clamps, the space between the rungs shall be 300mm. Cable tray routing shop drawing shall got approved from Consultant before execution at site. Supports shall be placed at intervals as per loading of the tray but minimum interval of 60cm to be kept between the supports . Fabrication works by welding, cutting, bendng etc required for reducing of shape, size, providing bends and cross connections or offseting of cable trays as per site requirement shall also be considered in this scope without any additional cost in a proffesional manner. The cut areas shall be repainted with anticorrosive material to avoid rusting. All other assecories as required for complete installations shall be considered in this scope of work. Cable tray suspenders shall be the same make as the tray manufacturer including Wall and support brackets With flange-welded head plate Steel St Length 610mm suitable for 600mm ladder, Suspended support from ceiling With flange-welded head plate Steel St 50x50x400 for 450mm tray and galvanized 8mm threaded support system with 2 nos of drops in anchor bolts, with heavy duty profile rail for remaining cable tray sizes" 450mm width x 50mm Height

2571.39

-

-

... More
od70494/2022_2023 : "Supply and fixing of Cable Ladder trays confirming to IEC-61537.The Cable Ladder shall be made of 1.5mm thick sheet steel including supply and providing galvanized 8mm (200 - 300mm wide trays) & 10mm (400-600mm wide trays) threaded support system with 2 nos of dropp in anchor bolts from ceiling with heavy duty profile rail of suitable size as per tray width.The cable Ladder shall be galvanized for corrosion protection confirming to ISO 1461 .The cable ladder should be tested for safe working load of 225 Kg/ Mtr (for 400 - 600mm wide tray) & 140 Kg / Mtr (for 200 - 300mm wide tray) with a span distance of 2 Mtr the deflection should be within the limits as per standard. The cable ladder shall be supplied in standard length of 3000 mm. The rung size shall be of 30x15mmm size suitable for fixing the cable clamps, the space between the rungs shall be 300mm. Cable tray routing shop drawing shall got approved from Consultant before execution at site. Supports shall be placed at intervals as per loading of the tray but minimum interval of 60cm to be kept between the supports . Fabrication works by welding, cutting, bendng etc required for reducing of shape, size, providing bends and cross connections or offseting of cable trays as per site requirement shall also be considered in this scope without any additional cost in a proffesional manner. The cut areas shall be repainted with anticorrosive material to avoid rusting. All other assecories as required for complete installations shall be considered in this scope of work. Cable tray suspenders shall be the same make as the tray manufacturer including Wall and support brackets With flange-welded head plate Steel St Length 610mm suitable for 600mm ladder, Suspended support from ceiling With flange-welded head plate Steel St 50x50x400 for 450mm tray and galvanized 8mm threaded support system with 2 nos of dropp in anchor bolts, with heavy duty profile rail for remaining cable tray sizes" 600mm width x 75mm Height

2981.53

-

-

... More
SAFETY EQUIPMENTS

-

-

-

... More
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

270.15

-

-

... More
2.22 : Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

291.98

-

-

... More
od70495/2022_2023 : Supply and fixing of 4 Kg ABC Dry Powder (Stored Pressure) Type Fire Extinguisher. pressurized with dry nitrogen gas at 15 bar. Design, construction and testing as per IS 2171-1999 external epoxy powder coating with PO Red Shade No. 538 of IS 5, Supplied with standard accessories.

2003.59

-

-

... More
od70497/2022_2023 : Supply and providing First Aid Box.

1135.37

-

-

... More
od70499/2022_2023 : Supply and providing laminated First Aid chart duly framed and placed in a conspicuous location for clear vision.

1602.87

-

-

... More
od70500/2022_2023 : Supply & fixing Laminated drawings of electrical lay out, schematic drawing etc on good frame work.

6612.5

-

-

... More
od70501/2022_2023 : Supply and providing MS chequered plate of suitable thickness including cutting, welding, painting etc. as required for cable duct covering etc.

6612.5

-

-

... More
od70502/2022_2023 : Supply & fixing of Class A Electrical rubber mat, used for up to 11 kV, Dielectric Strength of 33 kV , as per IS. 15652 - 2006 in front of various type HT equipments with ISI certification mark of standard 1 Mtr width.The work includes cleaning of the floor, fixing of insulation mat by using suitable adhesive, waterproofing compound, sealing materials etc., complete as required

4125.63

-

-

... More
14.14.2 : Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 150 mm dia

716.31

-

-

... More
14.15.1 : Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63 mm· dia (OD-63 mm & ID-51 mm nominal)

129.62

-

-

... More
14.15.3 : Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 120 mm dia (OD-120 mm & ID-103 mm nominal)

287.89

-

-

... More
11.6.2 : Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. 40 mm dia

440.7

-

-

... More
od70504/2022_2023 : Supply & fixing of Class A Electrical rubber mat, used for up to 3.3 kV, Dielectric Strength of 33 kV , 2 Mtr x 1 Mtr size 2 mm thick, as per IS. 15652 - 2006 in front of various type MV panels. as per IS:15652 - 2006 with ISI certification mark of standard 1 Mtr width.The work includes cleaning of the floor, fixing of insulation mat by using suitable adhesive, waterproofing compound, sealing materials etc., complete as required

3005.38

-

-

... More
CIVIL ITEMS

-

-

-

... More
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

120.54

-

-

... More
10.17 : Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.

202.75

-

-

... More
10.18 : Providing and fixing circular / hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing .

204.05

-

-

... More
Plumbing Sanitory fixtures and fittings

-

-

-

... More
od43714/2022_2023 : Providing and fixing white vitreous china pedestal type floor mounted water closet (European type W.C. pan) with seat and lid, 3/6 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (twin flush), with flow rate of 4.5 lpm including flow regulator with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid

52

-

-

... More
od43964/2022_2023 : Providing and fixing Under counter wash basin installed on granite/ marble with C.I. brackets, 15 mm C.P. brass pillar taps of standard pattern having low flow fixture with flowrate of 5 lpm including flow regulator confirming to IS standards, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require as per IS specification.(Granite / Marble counter will be installed by other agency)

36

-

-

... More
od43968/2022_2023 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps of standard pattern having low flow fixture with flowrate of 5 lpm including flow regulator confirming to IS standards, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:<br>White Vitreous China Flat back wash basin size 550x400mm with single 15 mm C.P.brass pillar taps

35

-

-

... More
od113927/2022_2023 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,of standard pattern having low flow fixture with flowrate of 5 lpm including flow regulator confirming to IS standards, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Angle back wash basin size 400x400 mm with single 15 mm C.P. brass pillar tap

14

-

-

... More
od43970/2022_2023 : Providing and fixing brass bib cock of approved quality having low flow fixture with flow rate of 5 lpm including flow regulator confirming to IS standards.

6

-

-

... More
od44138/2022_2023 : Providing and fixing C.P brass long nose bib cock of approved quality with flow rate of 5 lpm including flow regulator to IS standards and weighing not less than 810 gms. 15 mm nominal bore

35

-

-

... More
od43973/2022_2023 : Providing and fixing of 15 mm C.P. brass sink cock of low flow fixture category wall mounted with 188mm long swivel spout and wall flange with flow rate of 5 lpm including flow regulator with all fittings and brackets of approved quality

14

-

-

... More
17.10.1.1 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 250 mm

9

-

-

... More
17.10.2.1 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x510 mm bowl depth 200 mm

2

-

-

... More
od44050/2022_2023 : Providing and fixing of cleaner's sink of 600x520 mm including C.I. brackets, 32 mm C.P. brass waste of standard pattern ,pillar tap, connection pipe of 15mm including painting of fittings and brackets, cutting and making good the walls wherever require:

6

-

-

... More
od44051/2022_2023 : Providing and fixing of Hospital SS Bed Pan Sink SS 304/18 SWG SIZE 850 MM x 600 MM X 300 MM with 10 Liter CI High Level Flushing Cistern Flush Pipe, C.I./M.S. (Painting with 3 Coats of White Paint Complete with accessories.)

5

-

-

... More
od100370/2022_2023 : Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of flow rate of 2 lpm 430x260x350 mm or 340x410x265 mm sizes respectively including cp push cock of approved quality and colour

24

-

-

... More
od44068/2022_2023 : Providing & fixing, testing and commissioning of approved make & coloured urinal division plate of size 90 x320x720mm and fixed to wall by using CP brass screws etc. complete as per specifications. Make cera 5011

22

-

-

... More
18.65 : Providing and fixing PTMT Soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fittings arrangements, weighing not less than 106 gms.

99

-

-

... More
50.17.1.2 : Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

27

-

-

... More
17.72 : Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms

22

-

-

... More
od44103/2022_2023 : Supply, installation, testing and commissioning of mixer type shower system consisting of conversion bend for overhead shower with wall flanges and shower arm ,shower head etc having low flow fixture with flow rate of 5 lpm including flow regulator as per IS specification make and approved by the consultant, complete in every respect including, cutting, chasing & making good the walls

25

-

-

... More
od44104/2022_2023 : Supply, instalation,testing and commissioning of approved make of vertical / horizontal type Electric water heater suitable for pressure rating up to 4 Kg / Sqcm with heating element with thermostat, pressure relief valve, non - return valve with CP copper connecting pipes with wall flanges etc., complete with all inlets, outlets, valves and all other accessories etc., complete. Toilet Geyser.10 ltr

25

-

-

... More
17.69.2 : Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.Waste coupling 38 mm dia of 83 mm length and 77 mm breadth, weighing not less than 60 gms

92

-

-

... More
18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore

289

-

-

... More
od44109/2022_2023 : Supplying and fixing CP Health Faucet superior quality with with flow rate of 5 lpm including flow regulator, cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge

56

-

-

... More
17.28.1.1 : Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC. waste fittings complete.Semi rigid pipe32 mm dia

100

-

-

... More
17.31 : Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

87

-

-

... More
od44121/2022_2023 : Providing and fixing Disabled Toilet, Complete Set, including White Floor Mounted Water Closet with 3/6 Litre per flush, Plastic Cistern, Lid, Antimicrobial Seat Cover etc, Faucet/Tap with spactula lever and with 1no of Hinged Arm, 760mm. Long, 2nos of Grab Rail, each of 600mm. long, health faucet with flow rate of 5 lpm, pillar tap with flow rate 5 lpm and with all necessary accessories and fixed with Brackets Expansion/Rawl sleeves, stainless steel/ brass bolts/screws, nuts, washers etc, including cutting and making good the walls and floors wherever required. including all as per manufacture's and to the approval of Engineer-in-charge based on below 50% griha base rate

4

-

-

... More
od44123/2022_2023 : Fixing of superior quality Rob hook with brackets and flange with concealed brass screws etc as per IS specification make and approved by the client / consultant, including cutting & making good the walls.

53

-

-

... More
17.75 : Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2" BSP thread and shapes, weighing not less than 60 gms.

24

-

-

... More
17.71 : Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms

10

-

-

... More
od44126/2022_2023 : Supply,Installation, testing and commission, of scrub sink with ss grade 304,1.2mm thickness size: with taps - 1 no. with flow rate 5 LPM,pu pipe,male/female connectors(8nos),foot operated valve(1no etc ) im: 150X60X90+60(LWH) <br>• MADE OF 1.50MM THICK SS 304 SHEET AND TUBES <br>• BACK SPLASH 60CM , side splash 15cm<br>• WALL/FLOOR MOUNTED <br>• PERFORATED DRAIN BOARD & HIGH QUALITY WASTE COUPLING<br>• SENSOR CONTROLLED MIXER TAP WITH AC/DC POWER SUPPLY-OF 1 no<br>• KNEE OR FOOT OPERATED TAP OF 2 NOS<br>• SENSOR COTROLLED SOAP DISPENSOR -2Nos with 1 lire capacity, SS body

1

-

-

... More
od44127/2022_2023 : Supply,Installation, testing and commission, of water purifier with input water source filtering capabilty of RO ,UV MTDS 7Ltr water purifier,6 stages of purification electrical and non storage:electrical purification-suitable for direct water suppy,UV: Suitable for municipal water,purifies microbes levels with ISO Certified system complete with all fittings and acessories.The unit includes RO membarne,filters etc.

4

-

-

... More
od44128/2022_2023 : Supply,Installation, testing and commission, of eye washer SS-304 type-10 inch size round type,foot operated with shower height of 1020mm

1

-

-

... More
18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

5000

-

-

... More
PART B-WATER SUPPLY PIPES AND FITTINGS

-

-

-

... More
18.8.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes

572

-

-

... More
18.8.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes

180

-

-

... More
18.8.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.32 mm nominal outer dia pipes

6

-

-

... More
18.7.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal outer dia pipes

80

-

-

... More
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes

72

-

-

... More
18.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal outer dia pipes

30

-

-

... More
18.7.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal outer dia pipes

12

-

-

... More
od44193/2022_2023 : Providing and fixing UPVC pipes, for cold water supply, including all UPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.- 20 mm nominal outer dia Pipes ASTM D 1785 Sch.40

245

-

-

... More
od44196/2022_2023 : Providing and fixing UPVC pipes, for cold water supply, including all UPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.- 25 mm nominal outer dia Pipes ASTM D 1785 Sch.40

42

-

-

... More
od44198/2022_2023 : Providing and fixing UPVC pipes, for cold water supply, including all UPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.- 32mm nominal outer dia Pipes ASTM D 1785 Sch.40

10

-

-

... More
od44205/2022_2023 : Providing and fixing UPVC pipes, including all UPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall. 20 mm nominal outer dia Pipes ASTM D 1785 Sch.40

258

-

-

... More
od44207/2022_2023 : Providing and fixing UPVC pipes, including all UPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal outer dia Pipes ASTM D 1785 Sch.40

300

-

-

... More
od44209/2022_2023 : Providing and fixing UPVC pipes, including all UPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall. 32 mm nominal outer dia Pipes ASTM D 1785 Sch.40

90

-

-

... More
od44210/2022_2023 : Providing and fixing UPVC pipes, including all UPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 40 mm nominal outer dia Pipes ASTM D 1785 Sch.40

105

-

-

... More
od44213/2022_2023 : Providing and fixing UPVC pipes, including all UPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 50 mm nominal outer dia Pipes ASTM D 1785 Sch.40

302

-

-

... More
od44214/2022_2023 : Providing and fixing UPVC pipes, including all UPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 65 mm nominal outer dia Pipes

221

-

-

... More
od44223/2022_2023 : Providing and fixing UPVC pipes includings jointing of pipes with one step upvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia ASTM D 1785 Sch.40

210

-

-

... More
od44229/2022_2023 : Providing and fixing UPVC pipes includings jointing of pipes with one step upvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 65 mm dia ASTM D 1785 Sch.40

30

-

-

... More
18.17.1A : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore

31

-

-

... More
18.17.1 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore

39

-

-

... More
18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

7

-

-

... More
18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

5

-

-

... More
18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore

16

-

-

... More
18.17.5 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore

1

-

-

... More
18.19.4.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal boreHorizontal

10

-

-

... More
18.19.5.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):65 mm nominal boreHorizontal

1

-

-

... More
18.21.2.1 : Providing and fixing uplasticised PVC connection pipe with brass unions:45 cm length15 mm nominal bore

153

-

-

... More
18.60.1 : Providing and fixing enclosed type water meter (bulk type) conforming to IS: 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. ( The tail pieces if required will be paid separately):80 mm dia nominal bore

1

-

-

... More
od44236/2022_2023 : Providing, fixing, testing and commissioning of brass body nickel plated automatic air release valves with necessary GI Specials, thread, holdtight, brass spindle, NBR and elastomeric, stainless steel spring polypropylenic float at the top most points of water supply distribution ring main. 20 mm dia.

20

-

-

... More
od44239/2022_2023 : Supplying & Fixing at site in position Fabricated u PVC Astm Sch 80 Puddle flanges in the underground and overhead water tanks as per the drawings and the requirement of the Project Manager. 50mm dia

12

-

-

... More
od44240/2022_2023 : Supplying & Fixing at site in position Fabricated u PVC Astm Sch 80 Puddle flanges in the underground and overhead water tanks as per the drawings and the requirement of the Project Manager. 65mm dia

4

-

-

... More
od44242/2022_2023 : Supply and fixing of plastic ball float valve with gun metal lever of IS specification make and approved by the client / consultant for muncipal water inlet pipe to UG sump. 25 mm dia

2

-

-

... More
od44265/2022_2023 : Supply, Installation, testing and commissioning of smart water meter confirming to IS 4064 ,IP68 protection,radio interface with min 7 km range ,replaceable battery of multijet class B magnetic type 100mm meter battery powered with necessary fittings such as threaded pieces, unions, check nuts complete as required size:50mm dia

6

-

-

... More
od44273/2022_2023 : Supply, Installation, testing and commissioning of smart water meter confirming to IS 4064 of multijet class B magnetic type 100mm meter battery powered with necessary fittings such as threaded pieces, unions, check nuts complete as required- 32 mm size

1

-

-

... More
od44308/2022_2023 : Supply, Installation, testing and commissioning of data concentrator panel/control module for water meter (IP65 protection, radio interface for reading data) which is to be compactible for processing the data to the server. Price shall be including software for installation in the existing server, integration with all water meters, for processing of data with user interface and data storage facility to collect water consumption and meter details from all the water meters installed for the project.

3

-

-

... More
PART C- DRAINAGE PIPES-SOIL ,WASTE ,VENT PIPES AND FITTINGS

-

-

-

... More
50.18.8.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2

80

-

-

... More
50.18.7.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall

200

-

-

... More
50.18.8.8.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2

66

-

-

... More
50.18.8.9.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2

60

-

-

... More
od44324/2022_2023 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes, fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall

330

-

-

... More
od44326/2022_2023 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps/Clips at 1.00 m spacing. This included jointing of pipes, fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kfg/cm2 - External work - Exposed on wall

180

-

-

... More
od44328/2022_2023 : Providing and fixing PVC pipes including fixing the pipe, fittings with clamps/clips at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 4 Kgf/cm2- External work - exposed on wall

48

-

-

... More
od44330/2022_2023 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall

840

-

-

... More
od44332/2022_2023 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of & fittings pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall

495

-

-

... More
50.18.9.8.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2

80

-

-

... More
50.18.9.9.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2

75

-

-

... More
50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2

520

-

-

... More
od44333/2022_2023 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 200 mm dia 6 Kgf/cm2

245

-

-

... More
19.6.2 : Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:150 mm dia R.C.C. pipe

36

-

-

... More
19.6.3 : Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:250 mm dia R.C. C. pipe

60

-

-

... More
19.7.1.1 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

30

-

-

... More
19.8.1.1 : Extra for depth for manholesSize 90x80 cmWith common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5

10

-

-

... More
od44335/2022_2023 : Providing and fixing of floor traps (4'') to toilet floors and making good the concrete floor as per direction of engineer in charge:75x110mm size

130

-

-

... More
19.4.1.1 : Providing and fixing square-mouth S.W. gully trap class SP -1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5

16

-

-

... More
od44338/2022_2023 : Providing and fixing of P traps (4'') 110MM X110MM dia and making good the concrete floor as per direction of engineer in charge

8

-

-

... More
od303072/2022_2023 : Supply and fixing of SS floor clean out gratings with all accessories 5 inch of 304 grade thick with rim including setting in floor with white cement mortar and making good the floor.

16

-

-

... More
50.18.9.21.7 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl

12

-

-

... More
50.18.9.22.8 : Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl

24

-

-

... More
od44344/2022_2023 : Supplying, Installing & Testing at site in position PVC Rodding Eye (6 kg/cm2) complete in all respects.<br>110 mm dia <br>

54

-

-

... More
od44346/2022_2023 : Supplying, Installing & Testing at site in position PVC Rodding Eye (6 kg/cm2) complete in all respects.75 mm dia

30

-

-

... More
od44347/2022_2023 : Supply ,fixing ,testing and commissioning of PVC rain water khurra with C.I grating The quoted rate shall include necessary grouting the base of Khurras with approved sealant complete.150mmx150mm C.I grating

15

-

-

... More
19.32.1 : Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

1

-

-

... More
18.77 : Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.

330

-

-

... More
19.7.3.1 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x 90 cm and 90 cm deep including C.I. cover with frame ( heavy duty ) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg ( weight of cover 108 kg and weight of frame 100 kg)With common burnt clay F.P.S. ( non modular) bricks of class designation 7.5

22

-

-

... More
19.8.2.1 : Extra for depth for manholesSize 120x90 cmWith common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5

10

-

-

... More
PUMPS AND FITTINGS

-

-

-

... More
od67476/2022_2023 : Supply, testing and commissioning of Bore well submersible pump of with Moc of cast iron body, bronze impeller,IE3 efficiency for pumping water from well to ug tank with automatic control panel including level switches, control wires ,startor, Single phase preventor & dry run preventor etc capacity to deliver 50 lpm at 180m head (Depth of bore well considered is 500ft) (approximately 4HP)

1

-

-

... More
od67477/2022_2023 : Providing ,fixing, testing and commission, of open well submersible Type Water Transfer Pump with Moc of cast iron body, bronze impeller, IE3 efficiency for pumping water from STP treated water tank to overhead non domestic water tank with automatic control panel including level switches, control wires ,startor, Single phase preventor & dry run preventor etc. The price shall inclusive of all connected electrical work. Capacity 250 lpm at 40Mtrs. head, each, Electric motor driven, (HP as per selection of pump), 1 working +1 standby, three phase, 415V, AC Supply

1

-

-

... More
od67478/2022_2023 : Providing ,fixing, testing and commission, of open well submersible Type Water Transfer Pump with Moc of cast iron body, bronze impeller, IE3 efficiency for pumping water from Underground domestic water tank to overhead domestic water tank with automatic control panel including level switches, control wires ,startor, Single phase preventor & dry run preventor etc. The price shall inclusive of all connected electrical work. Capacity 250 lpm at 40Mtrs. head, each, Electric motor driven, (HP as per selection of pump), 1 working +1 standby, three phase, 415V, AC Supply

1

-

-

... More
od67479/2022_2023 : Providing & fixing, testing and commissioning of SS centrifugal Waste water Transfer Pump(sewage pump), for pumping waste water waste from collection pit from fire pump room, with  including solenoid valves, level switches, control wires etc. (1Working pump) with suitable HP Capacity:150lpm@25mtr head

1

-

-

... More
od69291/2022_2023 : Supply and installation of RO based water treatment plant of capacity 1000LPH as per below specification<br> <br>2.Anti-scalent Dosing System:- <br>Quantity :One ,Type :Positive Displacement Pump , Flow Range :0.2 to 4 LPH ,Max. Working Pressure :3.5 kg / cm2 MOC of Dosing Tank :HDPE – 100 Litres. 3.Acid Dosing System:<br>Quantity :One,Type :Positive Displacement Pump,Flow Range :0.2 to 4 LPH,Max. Working Pressure :3.5 kg / cm2,MOC of Dosing Tank :SS 304. 4.Cartridge Filter:- <br>No. of Unit :One,Type of Cartridge :PP Spun bonded type,Rating :5 micron,Flow Rate :1000 LPH.,Feed WaterTurbidity :5 NTU,No. of Cartridge :2 Nos. 500 mm long x 100mm dia.,MOC of Housing :SS 316. 5.Reverse Osmosis High Pressure Pump:- No. of Unit :Two,Type of Pump :Vertical Multistage Pump,Maximum Flowrate :1000 LPH<br>Operating Pressure :20.0 kg/cm2 (shall be indicated,Material of Construction :SS 316 6.Reverse Osmosis Membrane:- No. of Membrane : as per req qty,Size of Membrane :200mm Dia & 1000 mm Long,Type of Membrane :High rejection & low energy,Membrane Polymer :Composite Polyamide,Flow rate :80-100 LPH per membrane,Maximum Feedwater Turbidity :1.0 NTU <br>7.Reverse Osmosis Membrane Housing:- No. of Housing :2,Purpose :To pack membranes and operate at high pressure.,Maximum Flow rate :1000 LPH,Material of Construction :FRP/ Stainless Steel 316 Operating Pressure :20 Kg/cm2 (or higher if required),Position :Horizontal <br>8.pH Correction System:- Quantity :One,Type :Positive Displacement Pump,Flow Range :0.2 to 4 LPH,Max. Working Pressure :3.5 kg / cm2,MOC of Dosing Tank :SS 304. 9.Post Chlorination System:- Quantity :One,Type :Positive Displacement Pump,Flow Range :0.2 to 4 LPH,Max. Working Pressure :3.5 kg / cm2,MOC of Dosing Tank :SS 304.<br<br>10.Sytex tank:-1500ltrs<br><br>b.Instrumentation <br><br>1.Digital Type Conductivity Meter:- Digital Display,No. of Units : One,Type :Digital Display,Range :0-500 ohms /cm,Location :at the outlet of Reverse Osmosis System , 2.Pressure Gauges:- Specification :SS Pressure Gauge with brass internals with glycerin filled.,Size of Guage :65 mm Dial , <br>3.Rotameter:-<br><br>Specification :Acrylic Rotameter.,Range :Minimum 1.5 times the feed flow.,Location :Discharge of RawWater Pump. 4.Conductivity Indicator (CI) :- <br>Specification :Conductivity Sensor/Indicator.,Type of Sensor :On-Line Sensor.,Location :Outlet of RO Unit. <br>5.Pressure Switch :- <br>Seamless Bellow type Pressure,switch. Specification :Magnetic Type Level switch.,Level Switch :Alum Dosing System.Antiscalent Dosing System.<br><br><br>

1

-

-

... More
CABLES

-

-

-

... More
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

200

-

-

... More
od68633/2022_2023 : Providing of 4 pair 1.5 sq mm cable as control cable of liquid water level controller through a ISI Heavy duty 20mm conduit

200

-

-

... More
AIR HANDLING UNIT

-

-

-

... More
od49392/2022_2023 : "Supply, Installation ,Testing & commissioning of Floor Mounted AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil) made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain AL sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 8 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings , strip heaters (3x1.5KW), germicidal UV-C lamps etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.7.0 TR , 2491 CFM , 1500 Pa<br>

1

-

-

... More
od49394/2022_2023 : "Supply, Installation ,Testing & commissioning of Floor Mounted AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil) made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain AL sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 8 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings , strip heaters (3x1.5KW), germicidal UV-C lamps etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used. 7.5 TR , 2595 CFM , 1500 Pa<br>

3

-

-

... More
od49422/2022_2023 : "Supply, Installation ,Testing & commissioning of Floor Mounted AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil) made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain AL sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings , strip heaters (3x1.5KW), germicidal UV-C lamps etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.7.5 TR , 2843 CFM , 750 Pa<br>

1

-

-

... More
od49441/2022_2023 : "Supply, Installation ,Testing & commissioning of Floor Mounted AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil) made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain AL sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings , strip heaters (3x1.5KW), germicidal UV-C lamps etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.6.5 TR , 2390 CFM , 750 Pa<br>

1

-

-

... More
od49450/2022_2023 : "Supply, Installation ,Testing & commissioning of Floor Mounted AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil) made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain AL sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings , strip heaters (3x1.5KW), germicidal UV-C lamps etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used. 6.0 TR , 1777 CFM , 750 Pa<br>

2

-

-

... More
od49453/2022_2023 : "Supply, Installation ,Testing & commissioning of Floor Mounted AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil) made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain AL sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings , strip heaters (3x1.5KW), germicidal UV-C lamps etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used. 4.0 TR , 1491 CFM , 750 Pa

1

-

-

... More
od49471/2022_2023 : "Supply, Installation ,Testing & commissioning of Floor Mounted AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil) made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain AL sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings , strip heaters (3x1.5KW), germicidal UV-C lamps etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used . 2.5 TR , 803 CFM , 400 Pa

1

-

-

... More
od49708/2022_2023 : Supply,Installation and commissioning of copper refrigerant piping, complete with 19 mm thick closed cell Class O Nitrile Rubber Insulation for pipe size(22.2mm,9.5mm) Minimum thickness of copper tube is 1.2mm. fittings, elbows, bends, supporting and clambing arrangement on walls, cable trays/trenches including necessary civil works.Refrigerant piping to be measured based on the distance between the indoor and outdoor units irrespective of number of circuits. The piping will be measured as one length for suction and liquid line. Insulation will be measured along with the piping and not be claimed as extra. Copper tubes, shall be with thickness conforming to L type to ATM standards.The tubes shall be bright annealed copper upto and including 15 mm size. <br>

125

-

-

... More
od220397/2022_2023 : Supply, Installation ,Testing & commissioning of Floor Mounted AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil) made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain AL sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air & return air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings , strip heaters (3x1.5KW), germicidal UV-C lamps etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.9.0 TR , 3550 CFM , 750 Pa

2

-

-

-

-

-

... More
od49751/2022_2023 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of 1.0 TR HI-WALL VRV INDOOR UNIT UNIT . All Indoor Units shall be factory assembled, wired and tested. <br>

3

-

-

... More
od49754/2022_2023 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of 1.3 TR HI-WALL VRV INDOOR UNIT UNIT . All Indoor Units shall be factory assembled, wired and tested. <br>

2

-

-

... More
od49757/2022_2023 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of 1.6 TR VRV INDOOR UNIT UNIT . All Indoor Units shall be factory assembled, wired and tested. <br>

5

-

-

... More
od49764/2022_2023 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit,, conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of 2 TR HI-WALL VRV INDOOR UNIT UNIT . All Indoor Units shall be factory assembled, wired, piped and tested. <br>

7

-

-

... More
od49771/2022_2023 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit,, conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of 2.5 TR FOUR WAY CASSETTE UNIT . All Indoor Units shall be factory assembled, wired, piped and tested. All Units shall be controlled by Electronic Expansion Valves only. indoor Units shall have provision for connecting Fresh Air Ducts/Pipes<br>

2

-

-

... More
od49775/2022_2023 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit,, conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of 3.2 TR FOUR WAY CASSETTE UNIT . All Indoor Units shall be factory assembled, wired, piped and tested. All Units shall be controlled by Electronic Expansion Valves only. indoor Units shall have provision for connecting Fresh Air Ducts/Pipes<br>

4

-

-

... More
od220412/2022_2023 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit,, conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of 2.56 TR HI-STATIC DUCTABLE UNIT . All Indoor Units shall be factory assembled, wired, piped and tested. All Units shall be controlled by Electronic Expansion Valves only. indoor Units shall have provision for connecting Fresh Air Ducts/Pipe

1

-

-

... More
od49780/2022_2023 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit,, conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of 4.0 TR HI-STATIC DUCTABLE UNIT . All Indoor Units shall be factory assembled, wired, piped and tested. All Units shall be controlled by Electronic Expansion Valves only. indoor Units shall have provision for connecting Fresh Air Ducts/Pipes<br>

1

-

-

... More
od220445/2022_2023 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit,, conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of 5.4 TR HI-STATIC DUCTABLE UNIT . All Indoor Units shall be factory assembled, wired, piped and tested. All Units shall be controlled by Electronic Expansion Valves only. indoor Units shall have provision for connecting Fresh Air Ducts/Pipes

2

-

-

... More
od49803/2022_2023 : Supply, Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled outdoor units suitable for cooling and heating, having all hermetically sealed inverter type scroll compressor(s), minimum two compressors for above 14HP modules,microprocessor based controller, top discharge type<br>condensing unit(s), with R 410 A Refrigerant, vibration isolators,with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI conditions and work even at 50 deg C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5.” 20 HP Double Compressor , Top Discharge

2

-

-

... More
od50049/2022_2023 : Supply, Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled outdoor units suitable for cooling and heating, having all hermetically sealed inverter type scroll compressor(s), minimum two compressors for above 14HP modules,microprocessor based controller, top discharge type<br>condensing unit(s), with R 410 A Refrigerant, vibration isolators,with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI conditions and work even at 50 deg C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5.” 10 HP Single Compressor ,Top Discharge

2

-

-

... More
od50067/2022_2023 : Central remote controller<br>

5

-

-

... More
od50087/2022_2023 : Drain Pump for a 1.6 TR Hi Wall unit<br>

1

-

-

... More
od50094/2022_2023 : Drain Pump for a 2.0 TR Hi Wall unit<br>

1

-

-

... More
od50136/2022_2023 : Supply, Installation, testing and commissioning including Vacuumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with 19mm thick class-O close cell elastomeric nitrile rubber tubular sleeves sections for suction and liquid lines, all accessories as per specifications etc. as required. tube thickness is 1.2mm. (6.4 mm Dia)

130

-

-

... More
od50210/2022_2023 : Supply, Installation, testing and commissioning including<br>Vacuumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with 19mm thick class-O close cell elastomeric nitrile rubber tubular sleeves sections for suction and liquid lines, all accessories as per specifications etc. as required.tube thickness is 1.2mm.” 9.5 mm Dia

283

-

-

... More
od50292/2022_2023 : Supply, Installation, testing and commissioning including Vacuumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with 19mm thick class-O close cell elastomeric nitrile rubber tubular sleeves sections for suction and liquid lines, all accessories as per specifications etc. as required. tube thickness is 1.2mm.”12.7 mm Dia

105

-

-

... More
od50362/2022_2023 : Supply, Installation, testing and commissioning including Vacuumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with 19mm thick class-O close cell elastomeric nitrile rubber tubular sleeves sections for suction and liquid lines, all accessories as per specifications etc. as required. tube thickness is 1.2mm. 15.9 mm Dia

229

-

-

... More
od50379/2022_2023 : Supply, Installation, testing and commissioning including<br>Vacuumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with 19mm thick class-O close cell elastomeric nitrile rubber tubular sleeves sections for suction and liquid lines, all accessories as per specifications etc. as required. tube thickness is 1.2mm.19.1 mm Dia

81

-

-

... More
od50382/2022_2023 : Supply, Installation, testing and commissioning including Vacuumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with 19mm thick class-O close cell elastomeric nitrile rubber tubular sleeves sections for suction and liquid lines, all accessories as per specifications etc. as required. tube thickness is 1.2mm.28.6 mm Dia

57

-

-

... More
od50388/2022_2023 : Supply, Installation, testing and commissioning including Vacuumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with 19mm thick class-O close cell elastomeric nitrile rubber tubular sleeves sections for suction and liquid lines, all accessories as per specifications etc. as required. tube thickness is 1.62 mm.34.9 mm Dia

19

-

-

... More
od50443/2022_2023 : Supply,Installation and commissioning of copper ruff nut joint with insulation , all necessary support and accessories<br>

25

-

-

... More
od50584/2022_2023 : Supply, installation, testing & commissioning of following sizes insulated PVC drain pipe' from terminal units (AHUs, split units etc.) drain pans to nearest floor drain complete with interconnection, flanges, elbows, tees, nuts, U-trap etc. The insulation shall be 6 mm thick closed cell Class O Nitrile Rubber foam insulation.<br>25 MM Insulated PVC<br>

94

-

-

... More
od50585/2022_2023 : Supply, installation, testing & commissioning of following sizes insulated PVC drain pipe' from terminal units (AHUs, split units etc.) drain pans to nearest floor drain complete with interconnection, flanges, elbows, tees, nuts, U-trap etc. The insulation shall be 6 mm thick closed cell Class O Nitrile Rubber foam insulation.<br>32 MM Insulated PVC<br>

117

-

-

... More
od50586/2022_2023 : Supply, installation, testing & commissioning of following sizes insulated PVC drain pipe' from terminal units (AHUs, split units etc.) drain pans to nearest floor drain complete with interconnection, flanges, elbows, tees, nuts, U-trap etc. The insulation shall be 6 mm thick closed cell Class O Nitrile Rubber foam insulation.<br>40 MM Insulated PVC<br>

75

-

-

... More
od50587/2022_2023 : Supply, installation, testing & commissioning of following sizes insulated PVC drain pipe' from terminal units (AHUs, split units etc.) drain pans to nearest floor drain complete with interconnection, flanges, elbows, tees, nuts, U-trap etc. The insulation shall be 6 mm thick closed cell Class O Nitrile Rubber foam insulation.<br>50 MM Insulated PVC<br>

22

-

-

... More
od51638/2022_2023 : Supply, Installation, testing and commissioning including Vacuumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with 19mm thick class-O close cell elastomeric nitrile rubber tubular sleeves sections for suction and liquid lines, all accessories as per specifications etc. as required. tube thickness is 1.2mm. 22.2 mm Dia

37

-

-

... More
od108920/2022_2023 : Supply, Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled outdoor units suitable for cooling and heating, having all hermetically sealed inverter type scroll compressor(s), minimum two compressors for above 14HP modules,microprocessor based controller, top discharge type<br>condensing unit(s), with R 410 A Refrigerant, vibration isolators,with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI conditions and work even at 50 deg C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5.” 6 HP Single Compressor , Top Discharge<br>

1

-

-

... More
VENTILATION AND FRESH AIR FAN

-

-

-

... More
od50449/2022_2023 : Supply, installation, testing and commissioning Direct driven axial flow fans for exhaust suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , ≥ IE 3 : 225 CFM, 129 Pa

3

-

-

... More
od50457/2022_2023 : Supply, installation, testing and commissioning Direct driven axial flow fans for exhaust suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , ≥ IE 3 : 960 CFM, 136 Pa.

2

-

-

... More
od50469/2022_2023 : Supply, installation, testing and commissioning Direct driven axial flow fans for exhaust suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , ≥ IE 3 : 160 CFM, 125 Pa.

4

-

-

... More
od221727/2022_2023 : Supply, installation, testing and commissioning Direct driven axial flow fans for exhaust suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , ≥ IE 3 : 190 CFM , 143 Pa

1

-

-

... More
od50473/2022_2023 : Supply, installation, testing and commissioning Direct driven axial flow fans for exhaust suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , ≥ IE 3 : 600 CFM, 134 Pa

7

-

-

... More
od50475/2022_2023 : Supply, installation, testing and commissioning Direct driven axial flow fans for exhaust suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficiency , ≥ IE 3 : 300 CFM, 129 Pa

4

-

-

... More
od50491/2022_2023 : Supply, installation, testing and commissioning Direct driven axial flow fans for exhaust suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , ≥ IE 3 : 450 CFM, 138 Pa

4

-

-

... More
od50577/2022_2023 : Supply, installation, testing and commissioning Direct driven axial flow fans for exhaust suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , ≥ IE 3 : 1500 CFM , 160 Pa

1

-

-

... More
od50582/2022_2023 : Supply, installation, testing and commissioning Direct driven axial flow fans for exhaust suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , ≥ IE 3 : 100 CFM WALL MOUNTED FANS

13

-

-

... More
od50590/2022_2023 : Inline Fans - AHU room Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen Motor Efficiency , ≥ IE 3 : 600 CFM, 134 Pa

3

-

-

... More
od50592/2022_2023 : Inline Fans - AHU room Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen Motor Efficiency , ≥ IE 3 : 160 CFM , 125 Pa

8

-

-

... More
od50602/2022_2023 : Inline Fans - AHU room Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen Motor Efficiency , ≥ IE 3 : 225 CFM, 136 Pa

3

-

-

... More
od50603/2022_2023 : Inline Fans - AHU room Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen Motor Efficiency , ≥ IE 3 : 450 CFM, 132 Pa

4

-

-

... More
od50634/2022_2023 : Supply installation testing and commissioning of PVC Pipes 4 Kg/cm2 for Fresh air to cassette units with necessary elbows, butterfly dampers to regulate the air flow, hangers and also with necessary supports and accessories.200 mm Dia

29

-

-

... More
od50635/2022_2023 : Supply installation testing and commissioning of PVC Pipes 4 Kg/cm2 for Fresh air to cassette units with necessary elbows, butterfly dampers to regulate the air flow, hangers and also with necessary supports and accessories..160 mm Dia

21

-

-

... More
od108968/2022_2023 : Supply, installation, testing and commissioning Direct driven axial flow fans for exhaust suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , ≥ IE 3 : 450 CFM WALL MOUNTED FANS

1

-

-

... More
od108986/2022_2023 : Supply, installation, testing and commissioning Direct driven axial flow fans for exhaust suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , ≥ IE 3 : 200 CFM WALL MOUNTED FANS

3

-

-

... More
od108988/2022_2023 : Inline Fans - AHU room Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen Motor Efficiency , ≥ IE 3 : 1993 CFM , 132 Pa

1

-

-

... More
od221754/2022_2023 : Inline Fans - AHU room Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen Motor Efficiency , ≥ IE 3 : 1400 CFM, 160 Pa

1

-

-

... More
od271986/2022_2023 : Inline Fans - AHU room Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen Motor Efficiency , ≥ IE 3 : 960 CFM, 136 Pa

2

-

-

... More
SHEET METAL WORK AND INSULATION

-

-

-

... More
16.12.2.1 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick

1100

-

-

... More
16.12.2.2 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick

104

-

-

... More
od221912/2022_2023 : Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Actuator

8

-

-

... More
od221913/2022_2023 : Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Fire Damper

8

-

-

... More
od50747/2022_2023 : Supply & fixing of 8 mm thick Class O nitrile rubber insulation with antimicrobial property with adhesive as per the recommendation of the manufacturer with density 45-55kg/m3. Moisture Diffusion Resistance Factor or ‘µ’ value of the base insulation material shall be minimum 10,000 K value shall be - 0.033 @ 0 deg C<br>

1520

-

-

... More
od50749/2022_2023 : Supply & fixing of 10 mm thick Class 1 acoustic nitrile rubber insulation with antimicrobial property with adhesive as per the recommendation of the manufacturer with density 140-180kg/m3<br>

456

-

-

... More
od109176/2022_2023 : Supply, installation, balancing and commissioning of fabricated at site Aluminium sheet rectangular ducting complete with rubber gaskets, elbows, splitter dampers, vanes, hangers, supports , sealent etc. as per approved drawings and specifications of following sheet thickness complete as required. 22 Gauge (0.80MM)<br>

316

-

-

... More
AIR TERMINAL UNITS , DIFFUSERS AND LOUVERS

-

-

-

... More
od50760/2022_2023 : Supply, Installation, testing, commissioning and balancing of GSS powder coated fresh air/exhaust air louver with 4 side flanges, Bird netscreen, damper arrangement and all neccessary supprt and accessories , color should be approved by architect as per drawing. <br>

7.2

-

-

... More
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper

20

-

-

... More
16.17 : Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring and removable core.

8.8

-

-

... More
16.18 : Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring and removable core.

8.8

-

-

... More
od50925/2022_2023 : Supply, installation, testing and commissioning of AL volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc., as per specifications.<br>

15

-

-

... More
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

5

-

-

... More
od51004/2022_2023 : Supply, installation, testing and commissioning of powder coated extruded aluminium Return Air grills with louvers and without Aluminium volume control dampers as per specification <br>

10

-

-

... More
CONTROL WIRING

-

-

-

... More
od51062/2022_2023 : Supply, installation and commissioning of humidistats and control wiring between the strip heaters and humidistats with necessory accessories like relays, transformers, sensors etc.<br>

4

-

-

... More
od51100/2022_2023 : Supply, installation and commissioning of comminication cabling between indoor unit to out door unit with all necessary supports and accessories<br>

1750

-

-

... More
od51285/2022_2023 : Supply, installation and commissioning of electrical cabling between unit to isolator with all necessary supports and accessories<br>

445

-

-

... More
od51291/2022_2023 : Supply, nstallation, testing and commissioning of Back net Module with necessary supprots and accessories.<br>

1

-

-

... More
LAMINAR FLOW PANELS WITH HEPA FILTERS

-

-

-

... More
od55971/2022_2023 : Unidirectional Laminar flow plenum for the OT's with HEPA filters .plenum construction with 1 mm thick aluminium sheet, perforated diffuser:1 mm thick stainless stel(ss 304),19mm thick class"O" nitrile insulation with aluminium foil lamination on exterior side, 4 nos of duct connecting colar based on user requirement (maximum height 150mm/225mm),provision of upstream ports for testing and measurement,provision for OT light, SS 'L' angle brackets for ceiling suspension of the plenum. all in line with the OT standards.Mini Pleat HEPA Filters, Flange type Casing : Anodized Aluminium extruded profile - Flange typeMedia : Micro Glass Fiber of "Lydall, France" make Pack Depth: 50 mm Sealant : PU Sealant Gasket : 3mm thick XLPE Face Guard : Powder coated, Aluminium flattened expanded metal on both sides of the filtration media pack.Particle size efficiency : ≥ 99.99% @ 0.3 microns .Maximum operating temperature : 50º CEquivalent to : H14 of EN1822-1 TYPE 'D' of TEST - RP - CC - 001.5<br>Plenum Size: 2350 (L) x 1740 (W) x 455 (H) mm<br>Perforated Diffuser size : 2440 (L) x 1830 (W) mm<br>

4

-

-

... More
ELECTRICAL DRIVEN MAIN PUMP

-

-

-

... More
od44650/2022_2023 : Supplying, installation, testing and commissioning of diesel engine driven main fire pump <br>suitable for automatic operation and consisting of following, complete in all respects, as <br>required : (Diesel Driven Pump)<br>Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with<br>stainless steel shaft, mechanical seal conforming to IS 1520.<br>Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS<br>standard complete with auto starting mechanism, 12 /24 volts electric starting equipment,<br>diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm<br>thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer,<br>instruments and protection as per standard specification, stop solenoid for auto stop in the<br>event of fault with audio indications, painted with post office red colour etc. as required.<br>M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as<br>required.<br>Suitable cement concrete foundation duly plastered and with anti vibration pads<br>2280 lpm at 65 m Head<br><br>

1

-

-

... More
od44934/2022_2023 : Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable <br>for automatic operation and consisting of following, complete in all respects, as required : <br>Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze <br>impeller with stainless steel shaft, mechanical seal conforming to IS 1520.<br>Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for <br>operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, <br>horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.<br>M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as <br>required.<br>Suitable cement concrete foundation duly plastered with anti vibration pads.<br>2280lpm at 65mtr head

1

-

-

... More
od44935/2022_2023 : Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180lpm @65mtr head

1

-

-

... More
od44937/2022_2023 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3cx10sq.mm Al Cable<br>

12

-

-

... More
od44938/2022_2023 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3cx120sq.mm Al Cable<br>

12

-

-

... More
od44939/2022_2023 : Providing and fixing CI `Y' strainer suitable for operating pressure of 16 Kg / sqcm with SS 304 perforated sheet basket including rubber gasket, flanges, nuts, bolts and washers, complete as required.200 mm dia

1

-

-

... More
od44942/2022_2023 : Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :<br>100 mm dia

4

-

-

... More
od44943/2022_2023 : Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :<br>150 mm dia

6

-

-

... More
od58163/2022_2023 : Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating<br>with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers,<br>gaskets conforming to IS 13095 of following sizes as required 200mm dia

3

-

-

... More
od44945/2022_2023 : Supply,Installation, Testing and Commissioning of double flanged horizontal type Non-Return Valve as per IS 5312 of following sizes having CI body and GM moving parts, with nuts bolts, gaskets etc & tested 21 kg/cm2 150 mm dia

4

-

-

... More
od44946/2022_2023 : Supply,Installation, Testing and Commissioning of double flanged horizontal type Non-Return Valve as per IS 5312 of following sizes having CI body and GM moving parts, with nuts bolts, gaskets etc & tested 21 kg/cm2 100 mm dia

1

-

-

... More
od44966/2022_2023 : Supply,Installation, Testing and Commissioning of Air cushion tank (air-vessel) 250 mm dia. x 1.5 M high with dished top, made of minimum 6 mm thick M.S. pipe/plate complete with 25 mm dia. Brass Air Valve (Ball valve, pressure gauge type), 25 mm dia. Stop with brass stop cock, nipple, tees, elbow, pipe, drain valve and all accessories as required incl. fixing brackets.

1

-

-

... More
od44967/2022_2023 : Supply,Installation,Testing and Commissioning of Pressure switch bellow type of approved make.

4

-

-

... More
od44968/2022_2023 : Supply, Installation,Testing and Commissioning of Pressure gauge with 0 to 200PSI,25 mm dia.

10

-

-

... More
od44969/2022_2023 : Supply,Installation,Testing & Commissioning of Bronze body lever operated stainless steel ball valve (PN 20) of approved make with necessary MTA fittings in position as per drawings.-25 mm dia

2

-

-

... More
HYDRANT SYSTEM

-

-

-

... More
od44971/2022_2023 : Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Gunmetal

10

-

-

... More
od44972/2022_2023 : Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required: Single headed Gunmetal

6

-

-

... More
od44973/2022_2023 : Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal<br>internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required

16

-

-

... More
od44974/2022_2023 : Supply and Fixing of weather proof Hose cabinet suitable size "having made of 16 gauge MS Sheet with common keylock arrangements, suitable to accommodate two lengths of 15mtr hoses, and one no branch pipe with nozzle. The cabinet shall be painted to scarlet red colour out side and off-white inside.

16

-

-

... More
od44976/2022_2023 : Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female<br>couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :<br>

32

-

-

... More
od44977/2022_2023 : Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office<br>red, conforming to IS 884 complete with the following as required.<br>20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS:<br>12585<br>20 mm nominal internal dia gun metal globe valve & nozzle.<br>Drum and brackets for fixing the equipmets on wall.<br>Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.

10

-

-

... More
od45028/2022_2023 : Supply,Installation,Testing and Commissioning of Hydrant valve Chamber: Brick masonry chambers in cement mortar 1:5 (1 cement: 5 Coarse sand) on cement concrete foundations 150mm thick 1:4:8 mix (1 cement: 4 fine sand: 8 graded stone aggregate 40mm nominal size) 15mm thick cement plaster inside and outside finished with a floating coat of neat cement inside with cast iron surface box approved by local fire brigade including excavation, back filling complete Valve chambers shall be of following sizes:For depths up to 1mtr. 450mm X 450mm. For depths up to 1mtr. & beyond 1000mm X 1000mm

3

-

-

... More
od45029/2022_2023 : Supply,Installation,Testing and Commissioning of Air Release Valve GM 20mm<br>dia type of approved make

4

-

-

... More
od68919/2022_2023 : Supplying and fixing of fire brigade tank filling connection of cast iron body with gun metal male<br>instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia GI pipe<br>connection conforming to IS 904 as required :<br>4way-150mm dia Gi pipe<br>

1

-

-

... More
od58415/2022_2023 : Supplying and fixing of fire brigade connection of cast iron body with gun metal male<br>instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia GI pipe<br>connection conforming to IS 904 as required :<br>4way-150 mm dia G.I. Pipe

1

-

-

... More
HYDRANT PIPE

-

-

-

... More
od118982/2022_2023 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required : 200mm dia

18

-

-

... More
od119185/2022_2023 : <br>Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS<br>1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground<br>including welding, excavation & providing cement concrete blocks as supports, anticorrosive<br>treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes<br>complete as required. 150 mm dia

310

-

-

... More
od119131/2022_2023 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required :<br>150mm dia

50

-

-

... More
od119132/2022_2023 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required :<br>100mm dia

24

-

-

... More
FIRE SPRINKLER SYSTEM

-

-

-

... More
od45097/2022_2023 : Sprinkler Bulbs : Supply,Installation,Testing and Commissioning of 15 mm gun metal sprinkler heads Quick response standard coverage with quarts bulb and set to operate at a specified temperature as per the specifications.<br>Temperature of operation 68 degree Celsius. K 80 for other areas.Upright sprinkler type

100

-

-

... More
od45099/2022_2023 : Sprinkler Bulbs : Supply,Installation,Testing and Commissioning of 15 mm gun metal sprinkler heads Quick response standard coverage with quarts bulb and set to operate at a specified temperature as per the specifications.<br>Temperature of operation 68 degree Celsius. K 80 for other areas. Pendant type sprinkler

560

-

-

... More
od44942/2022_2023 : Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :<br>100 mm dia

10

-

-

... More
od58598/2022_2023 : Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :<br>80mm dia

1

-

-

... More
od45117/2022_2023 : Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of<br>stainless steel complete with 15 NPT on reducer thread with maximum working pressure of<br>175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to<br>sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center<br>bracket, stockbar of following sizes complete as required.-1200 mm

80

-

-

... More
od45118/2022_2023 : Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of<br>stainless steel complete with 15 NPT on reducer thread with maximum working pressure of<br>175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to<br>sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center<br>bracket, stockbar of following sizes complete as required. 1000 mm

280

-

-

... More
od45119/2022_2023 : Supply,Installation,Testing & Commissioning of Bronze body lever operated stainless steel ball valve (PN 20) of approved make with necessary MTA fittings in position as per drawings.-25 mm dia

24

-

-

... More
od119132/2022_2023 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required :<br>100mm dia

115

-

-

... More
od119133/2022_2023 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia

115

-

-

... More
od119134/2022_2023 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required :<br>65mm dia

195

-

-

... More
od119135/2022_2023 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required :<br>50mm dia

280

-

-

... More
od119136/2022_2023 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required :40mm dia

230

-

-

... More
od119137/2022_2023 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required :32 mm dia<br>

130

-

-

... More
od119138/2022_2023 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required :25mm dia

950

-

-

... More
FIRE ALARMS (ADDRESSABLE) SYSTEM

-

-

-

... More
od75904/2022_2023 : Supplying, installation, testing and commissioning of micro processor based<br>intelligent addressable main fire alarm panel, central processing unit with the<br>following loop modules and capable of supporting not less than 240 devices<br>(including detectors) and minimum 120 detectors per loop and loop length up to 2<br>km, network communication card, minimum 320 character graphics/ LCD display<br>with touch screen or other keypad and minimum 4000 events history log in the non<br>volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up<br>with 24 volt sealed maintenance free batteries with automatic charger. The panel<br>shall have facility to connect printer to printout log and facility to have seamless<br>integration with analog/digital voice evacuation system ( which is part of the schedule<br>of work under SH: PA System) and shall be complete with all accessories .upto 5 extendable cards 2 loop panel

1

-

-

... More
od46001/2022_2023 : Supply,Installation,Testing and Commissioning of Intelligent Addressable Heat Detector with base.The detector shall be suitable for both rate of rise and fixed temperature.

6

-

-

... More
od46002/2022_2023 : Supply, installation, testing and commissioning of Sounder cum Strobe rated at 80 dBA @ 3m for Audible annunciation and 115cd flashintg at 1 Hz for visual indication. UL Listed

14

-

-

... More
od46003/2022_2023 : Supply, Installation,Testing and Commissioning of Addressable Manual Call Point (Pull down / Break Glass Type). The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device at indicated locations with necessary termination complete with all accessories like base. base box, etc as per acceptable specifications and full ready for operation.

14

-

-

... More
od46004/2022_2023 : Supply,Installation,Testing and Commissioning of Short Circuit Isolator Module for isolating the affected segment of the circuit, allowing the remaining devices to continue operation.

24

-

-

... More
od46005/2022_2023 : Supply,Installation,Testing & Commissioning of Analogue Addressable Response indicator including all accessories compatible with all the fire detectors required for complete installation.

42

-

-

... More
od75880/2022_2023 : Supply, installation, testing and commissioning of Addressable Photoelectric Smoke Detector with sensitivity range of 0.5 to 4.0% obs/ft. The detector shall have group decision technology for faster response & avoid false alarms. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches complete with all accessories like base. base box, etc. Designed to meet UL268, 7th Edition.

290

-

-

... More
od46009/2022_2023 : Supply, Installation,Testing and Commissioning of addressable control module for hooters at different locations complete with all fixing accessories.

14

-

-

... More
od46011/2022_2023 : Supply, laying, testing and commisioning and making terminations for 2 Core x 1.5 Sq.mm cable, Armoured Screened FRLS Twin Twisted PVC Insulated copper cable along with all accessories required for complete installation, making terminations etc where required

1300

-

-

... More
od46012/2022_2023 : Supply,Installation,Testing and Commissioning of Intelligent Addressable monitor modules for Sprinkler Flow Switch, Fire doors, magnetic contacts & WLD monitoring complete as required as per specifications

10

-

-

... More
od58583/2022_2023 : Supply installation and testing and commissioning of Flow Switches as shown and as specified in the specifications and drawings.

10

-

-

... More
TWO WAY TALK BACK SYSTEM

-

-

-

... More
od46014/2022_2023 : Supply, installation, testing & commissioning of automatic 10 ZONE master control console to connect 16<br>no.s of PA Talk back unit microprocess based complete with floor to floor announcing and talkback<br>facilities with the following features and made functional:(a)Feather type keypads to select the zones.<br>(b) Moulded plastic attractive enclosure. (c)Back light Liquid Crystal Display (LCD) (d) User friendly<br>interactive display.(e)Announcement selector PTTSwitch. (f)Listen selector switch. (g) All Call switch to<br>select all zones simultaneously for announcement (h) Zones Call Display On the LCD With Audio Alarm.<br>Panel to be installed in the Fire Control Room

1

-

-

... More
od46015/2022_2023 : Controller Unit Goose neck type microphone and with the following features: (i) Built in Power supply.( ii) Zone Selector switching Circuit (iii) Terminal blocks to terminate zones wires, amplifier wires etc., (iv) Zone Call processing Circuit etc and made functional .Panel to be installed in the Fire Control Room.

1

-

-

... More
od46017/2022_2023 : Supply, laying, testing and commisioning of 4Cx 1.0 Sqmm PVC insulated, Tinned Copper Conductor Cable- Unscreened<br>

180

-

-

... More
od46018/2022_2023 : Supply,installation,testing and commisioning of Public Address speaker with talk back facility 6 Watts with LMT and call switch, made out of powder coated CRC A sheet ,wall mounting type and to be installed at a height of not less than 150 CM from the finished floor levels, suitable for concealed mounting.

4

-

-

... More
od46019/2022_2023 : CONDUITING<br>Supply and laying of 25MM PVC Conduit with all accessories<br>

180

-

-

... More
FIRE RATED DOORS

-

-

-

... More
od51681/2022_2023 : Providing and fixing of Sheet metal duct door for the fire duct size 1500 X900mm ,fabricated from 16SWG GI CR Sheet & 18SWG shutter, sheets fully powder coated as per standard colour requirements of the Client with door handle, hinges and locking arrangements.

10

-

-

... More
SIGNAGES

-

-

-

... More
od51684/2022_2023 : Providing and installation in position the following type of sign boards made out of 3 mm thick "Opaque" PVC foam board with computer cut,Photoluminescent type self glowing vinyle painted foam board,complete with mirror fastners, glasscovering etc.Samples has to approved by the Architect before procuring the same. Signage with printed IN CASE OF FIRE DO NOT USE LIFT,USE THE STAIRS,of 1.25 cm height letters in red with white background. The board shall be fixed at the height of 2 mts. from finished floor near lifts.

12

-

-

... More
od51685/2022_2023 : Providing and installation in position the following type of sign boards made out of 3 mm thick "Opaque" PVC foam board with computer cut,Photoluminescent type self glowing vinyle painted foam board,complete with mirror fastners, glasscovering etc.Samples has to approved by the Architect before procuring the same. Floor indentification signages (ie,GROUNDFLOOR,FIRSTFLOOR,…etc.) at each stair enclosure on every floor,indicating the floor number in words,lettering size shall be7.5cm with contrasting colour from background.

15

-

-

... More
od58584/2022_2023 : Providing and installation in position Signage with printed SAFE ASSEMBLY AREA, of 1.25 cm height letters in red with white background.The size of the board shall be 40x30 cm and shall be fixed at the safe assembly areas demarked outside the building.

1

-

-

... More
od58585/2022_2023 : Supply and installation of in position the signages "FIRE ORDER" it should contain the following matter on 3mm thick "Opaque" PVC foam board of computerized cut, PVC Non-reflective self adhesive vinylepainted foamboard of 3'x4'. Samples has to approved by the Architect before procuring the same.A) ALERT THE SECURITY BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATIONS. B) EVACUATE THE OCCUPANTS BY USING FIRE EXITS AND EMERGENCY EXITS ONLY, AND ASSEMBLE AT VARIOUS ASSEMBLY POITS. C) IF POSSIBLE TRY TO EXTINGUISH THE FIRE BY USING NEAREST / SUITABLE PORTABLE FIRE EXTINGUISHER OR WATER FROM NEAREST HOSE REEL. D) BE CALM AND DO NOT GIVE ANY ROOM FOR PANIC. WALK, DO NOT RUN. E) IF YOU ENCOUNTER SERIOUS DIFFICULTY IN EVACUATION ,LAY FLAT AND TRY TO ATTRACT ATTENTION OF RESCUE TEAM. F) TRY TO COVER YOUR FACE WITH A WET TOWEL TO AVOID BREATHING SMOKE OR OTHER TOXIC FUMES. ACTION BY SECURITY / RECEPTION UPON RECEIPT OF INFORMATION THROUGH FIRE ALARM OR PUBLIC ADDRESS SYSTEM. A) ALERT THE OCCUPANTS BY USING PUBLIC ADDRESS SYSTEM. B) INFORM FIRE CONTROL THROUGH ANYONE OF THE FOLLOWING PHONE NUMBERS:101 /………………….( Local fire station number) C) REFER EVACUATION PLAN.D) GUIDE THE FIRE FORCE, ON THEIR ARRIVAL TO THE SEAT OF FIRE. E) IN CASE OF CASUALTIES, CALL AMBULANCE (Local numbers:) PHONE : -----------------------

1

-

-

... More
od58586/2022_2023 : Supply and installation in position self glowing Signage with printed IN CASE OF FIRE BREAK GLASS, of 1.25cm height letters in red with white background.The size of the board shall be 10x15 cm and shall be fixed at the height of 2 mts. from finished floor near the Manual Call Points.

14

-

-

... More
od58587/2022_2023 : Providing and installation in position self glowing "FIREEXIT" / "EXIT" signboards with directional arrow markings of made of luminescent safety ,rigid sheet in green colour,photoluminescent type Samples has to be approved by the Architect before procuring the same.

32

-

-

... More
od58588/2022_2023 : Providing and installation in position self glowing Signage with printed FIRE EXTINGUISHER /FIREHYDRANT /FIREFIGHTING EQUIPMENTS OREDINSIDE, of 1.25 cm height letters in red with white background. The size of the board shall be 25 x35 cm and shall be fixed at the height of 2 mts. from finished floor near the fire ducts

28

-

-

... More
od58589/2022_2023 : Providing and installation in position 1 x 6W, 240 V, 1 ph, 50 Hz indoor type emergency exit light fixture with 1.3 AH 4hrs battery back up unit, LED Lamps, indicating Fire Exit, recess mounted type. 24hrs x 7days working conditional.

15

-

-

... More
FIRE EXTINGUISHER

-

-

-

... More
od58590/2022_2023 : Supply and fixing of 4 Kg ABC Dry Powder (Stored Pressure) Type Fire Extinguisher. pressurized with dry nitrogen gas at 15 bar. Design, construction and testing as per IS 2171-1999 external epoxy powder coating with PO Red Shade No. 538 of IS 5, Supplied with standard accessories.<br>

12

-

-

... More
od58591/2022_2023 : Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters “FIRE” in black and gold. Cost shall be inclusive of providing MS stand for 4 nos of fire buckes, or , duly painted over a coat of primer.

2

-

-

... More
od58592/2022_2023 : Supply and fixing of 2 Kg Fire Extinguisher Clean Agent HFC 236 FA, Stored Pressure Type, Pressure Gauge, Ozone Depletion Potential Zero, Gross Weight 3.7 Kg, Empty Weight 1.7 Kg,, Discharge time minimum 8 Seconds, Controllable discharge mechanism, Range minimum 2 Meters IS 15683

6

-

-

... More
od58594/2022_2023 : Supply and fixing of 9Kg Mechanical foam Type Fire Extinguisher storred pressure, Design, construction and testing as per IS 15683 externally painted with PO Red Shade No. 538 of IS 5, Supplied with standard accessories.

1

-

-

... More
od58595/2022_2023 : Supply and fixing of 2Kg ABC Dry Powder (Stored Pressure) Type Fire Extinguisher. pressurized with dry nitrogen gas at 15 bar. Design, construction and testing as per IS 2171-1999 external epoxy powder coating with PO Red Shade No. 538 of IS 5, Supplied with standard accessories.

32

-

-

... More
od58596/2022_2023 : Supply and fixing of 4.5 Kg CO2 (Wheel) Type Fire Extinguisher, Design, construction and testing as per IS 2878 -2004 externally painted with PO Red Shade No. 538 of IS 5, Supplied with standard accessories.

2

-

-

... More
od58597/2022_2023 : Supply and fixing of 2Kg CO2 (Wheel) Type Fire Extinguisher, Design, construction and testing as per IS 2878 -2004 externally painted with PO Red Shade No. 538 of IS 5, Supplied with standard accessories.

4

-

-

... More
Oxygen Supply System

-

-

-

... More
od59547/2022_2023 : Supply, Installation, Testing and commissioning of fullyautomatic Oxygen Control Panel with minimum flow rate of 1500 LPM<br>

1

-

-

... More
od59569/2022_2023 : Supply, Installation, Testing and commissioning of Oxygen Manifolds - 2 banks x 10 cylinders with all accessories etc.<br>

1

-

-

... More
od59798/2022_2023 : Supply, Installation, Testing and commissioning of Emergency Cylinder Manifold 2 bank x 4 cylinders with emergency Oxygen high flow regulator with gauges and safety valves with all accessories etc.<br>

1

-

-

... More
Nitrous Oxide Supply System

-

-

-

... More
od59800/2022_2023 : Supply, Installation, Testing and commissioning of Semi automatic N2O Control Panel with minimum flow rate of 130 LPM<br>

1

-

-

... More
od59802/2022_2023 : Supply, Installation, Testing and commissioning of N2O Manifold - 2 banks x 2 cylinders with all accessories etc<br>

1

-

-

... More
od59803/2022_2023 : Supply, Installation, Testing and commissioning of Emergency N2O Cylinder Manifold -1 bank x 2cylinders with emergency N2O high flow regulator with gauges and safety valves with all accessories etc<br>

1

-

-

... More
Carbon Dioxide Supply System

-

-

-

... More
od59804/2022_2023 : Supply, Installation, Testing and commissioning of CO2 Manifold - 2 banks x 2 cylinders with all accessories etc.<br>

1

-

-

... More
od59805/2022_2023 : Supply, Installation, Testing and commissioning of Semi automatic CO2 Control Panel with minimum flow rate of 80LPMN<br>

1

-

-

... More
Compressed Air Plant

-

-

-

... More
od59806/2022_2023 : Supply, Installation, Testing and commissioning of Duplex Mediacl grade compressed Air System must have 2 nos medical grade scroll compressor in compact super sound absorbing tower design complete with all required cooling, control and monitoring facilities for operations in system with 2 compressors, a control panel, 1 air receivers 1500 L., 2 Dryer and double filtration unit - 5-stage conditioning systems with filters and adsorption dryer and a pressure reducer station, electrical control panel including starter and necessary connections etc. The installation must fully comply with the standard EN ISO7396-1/NFPA 99 and the produced air must be for medical use according to the European Pharmacopoeia as per the tech spec.. Each compressor should have minimum FAD of 1930 LPM (68CFM). Third party certification to be produced for medical grade air quality and compressor FAD capacity verification.<br>

1

-

-

... More
Vacuum Plant

-

-

-

... More
od59807/2022_2023 : Supply, Installation, Testing and commissioning of Medical grade Duplex Vacuum System must have 2 rotary vane type vacuum pumps directly driven by motor, a control panel, 1 vacuum receivers 2000 Ltr.,secretion Trap and bacteria filter, electrical control panel etc. The installation must fully comply with the standard EN ISO7396-1/NFPA 99. each vacuum pump should have FAA 2045 LPM at 450mmHg,<br>

1

-

-

... More
Area control unit (Area alarm + Area valves)

-

-

-

... More
od59808/2022_2023 : Area Control Unit for 6 Gases (O2, Air4,Air7,N2O,N, CO2) and 1 Vac<br>

2

-

-

... More
od59809/2022_2023 : Area Control Unit for 2 Gases (O2, Air4) and 1 Vac<br>

1

-

-

... More
od59810/2022_2023 : Area Control Unit for 1 Gases (O2) and 1 Vac (DN 20)<br>

1

-

-

... More
Isolation valves

-

-

-

... More
od59814/2022_2023 : Supply, Installation, Testing and commissioning of Ball Valve, DN 20 - 22x1<br>

12

-

-

... More
od59815/2022_2023 : Supply, Installation, Testing and commissioning of Ball Valve, DN 25 - 28x1,5<br>

5

-

-

... More
od59816/2022_2023 : Supply, Installation, Testing and commissioning of Ball Valve, DN 32 - 35x1,5<br>

4

-

-

... More
od59836/2022_2023 : Supply, Installation, Testing and commissioning of Ball Valve, DN 40 - 42x1,5<br>

7

-

-

... More
od59837/2022_2023 : Supply, Installation, Testing and commissioning of Ball Valve, DN 42 - 54x1,5

4

-

-

... More
od64780/2022_2023 : Ball Valve, DN 80 - 76x1,5<br>

1

-

-

... More
od64799/2022_2023 : Ball Valve, DN 100 -108x1,5<br>

2

-

-

... More
od75744/2022_2023 : Supply, Installation, Testing and commissioning of Ball Valve, DN 15 - 15x1<br>

25

-

-

... More
Terminal units Wall mounted - BS standard

-

-

-

... More
od59817/2022_2023 : Terminal Unit N<br>

4

-

-

... More
od59818/2022_2023 : Terminal Unit CO2<br>

4

-

-

... More
od59819/2022_2023 : Terminal Unit Air 700<br>

4

-

-

... More
od59820/2022_2023 : Terminal Unit Vac<br>

82

-

-

... More
od59821/2022_2023 : Terminal Unit Air 400<br>

41

-

-

... More
od59822/2022_2023 : Terminal Unit N2O<br>

4

-

-

... More
od59823/2022_2023 : Terminal Unit O2<br>

111

-

-

... More
od39031/2024_2025 : Terminal unit AGSS

4

-

-

... More
od59824/2022_2023 : Probes<br>

221

-

-

... More
Medical Equipment

-

-

-

... More
od59825/2022_2023 : Supply, installation, testing and commissioning of Ward Suction Unit with 1000 ml suction jar as per specifications. Matching probe / adaptor shall be provided at one end suitable for vacuum gas outlets and other end for Vacuum Hose.<br>

4

-

-

... More
od59826/2022_2023 : Supply, installation, testing and commissioning of Oxygen Flow meter with humidifier bottle. Matching probe / adaptor shall be provided at one end suitable for Oxygen Gas Outlets and other end for flow meter.<br>

4

-

-

... More
od64846/2022_2023 : Supply, installation, testing and commissioning of Theatre Suction Unit with 3200 ml jars as per specifications. Matching probe / adaptor shall be provided at one end suitable for Vacuum Gas outlets and other end for Vacuum Hose including trolley.<br>

4

-

-

... More
od65284/2022_2023 : Supply, Installation, Testing and commissioning of pendant operated WAGD SYSTEM (meeting ISO<br>7396-2/HTM02-01)

4

-

-

... More
Master plant alarm

-

-

-

... More
od59827/2022_2023 : Master plant alarm<br>

1

-

-

... More
Copper Piping As per EN13348 standards.

-

-

-

... More
od59828/2022_2023 : Copper Piping As per EN13348 standards.<br>54mm

400

-

-

... More
od59829/2022_2023 : Copper Piping As per EN13348 standards.<br>42mm

500

-

-

... More
od59830/2022_2023 : Copper Piping As per EN13348 standards.<br>35mm

320

-

-

... More
od59832/2022_2023 : Copper Piping As per EN13348 standards.<br>28mm

380

-

-

... More
od59833/2022_2023 : Copper Piping As per EN13348 standards.<br>22mm

530

-

-

... More
od59834/2022_2023 : Copper Piping As per EN13348 standards.<br>15mm<br><br>

1220

-

-

... More
od59835/2022_2023 : Copper Piping As per EN13348 standards.<br>12mm

1380

-

-

... More
od62073/2022_2023 : 76mm<br>

50

-

-

... More
od62079/2022_2023 : 108 mm<br>

50

-

-

... More
Bed Head Panels

-

-

-

... More
od38337/2024_2025 : Supply, installation, testing and commissioning of Horizontal Bed Head Panels of 4 feet long with provision for 3 nos electrical (power & data) & min 5 nos Gas outlets - as per technical specification for ICU beds

45

-

-

... More
od65284/2022_2023 : Supply, Installation, Testing and commissioning of pendant operated WAGD SYSTEM (meeting ISO<br>7396-2/HTM02-01)

5

-

-

... More
10 cum Bio gas plant

-

-

-

... More
od46391/2022_2023 : Supply, installation, testing and commissioning of 10 cum biogas plant with a waste treatment capacity of 50kg/day. The rate shall be inclusive of all safety devices and accessories required for complete installation as required.

1

-

-

... More
SEWAGE TREATMENT PLANT-60KLD MBBR

-

-

-

... More
od92388/2022_2023 : Supply, Installation,Testing & Commissioning of Fine Screen for sullage MoC: SS 304, Bucket Type Screen, Frame in 1” Square Pipe and Perforated Sheet with 6 mm Spacing with suitable facility to remove trapped materials.

1

-

-

... More
od92460/2022_2023 : Supply, Installation,Testing & Commissioning of Coarse Screen forsewage MoC: SS 304, Angle of Inclination – 45 deg, Frame in 1” Square Pipe and Bars made of 10 mm Square Pipe with 12 mm Spacing with suitable facility to remove trapped materials.

1

-

-

... More
od92470/2022_2023 : Supply, Installation,Testing & Commissioning of Aeration Grid withCoarse Bubble Diffusers Disc or Tube Type Coarse Bubble Diffusers with Design Flow rate of 3-5 m3/hr with EPDM membrane construction, 8 Nos with associated Pipe work in MSEP up to Main Header and uPVC ASTM Sch 40 Pipe for Wetted Parts for Aeration Grid as required in Equalization tank, Chemical precipitation tank etc.

1

-

-

... More
od92478/2022_2023 : Supply, Installation,Testing & Commissioning of Aeration Grid with Fine Bubble Diffusers in MBBR tank.Disc or Tube Type Fine Bubble Diffusers with Design Flow rate of 3-5 m3/hr with EPDM membrane construction, 12 Nos with associated Pipe work in MSEP up to Main Header and uPVC ASTM Sch 40 Pipe for Wetted Parts for Aeration Grid as required for achieving uniform aeration.

1

-

-

... More
od92489/2022_2023 : Supply, Installation,Testing & Commissioning of Raw sewage transfer pump Submersible Sewage Transfer Pumps(cutter pump), Continuous Duty, Minimum Discharge of 250 LPM, or above, with 10 m Head, three phase with Power: 2.0 HP,in a configuration of 1 Working & 1 Standby, with Outlet Pressure monitoring, Strainers, Recirculation Valves, Check Valves & all required accessories etc. Complete

1

-

-

... More
od92620/2022_2023 : Supply, Installation,Testing &Commissioning of Twin Lobe Blower with Motor Continuous Duty, Operating Discharge of 120 m3/hr or above, with differential Pressure of 4m WC, With three phase Motors, pulley fixed on a frame with Inlet / Outlet Silencers and Header Piping as required in MSEP, in a configuration of 1 Working & 1 Standby, also with Outlet Pressure monitoring, Pressure Relief Valves, Check Valves, Hand Valves & all required accessories etc. Complete.

1

-

-

... More
od92624/2022_2023 : Supply, Providing in Position, Testing & Commissioning of Aerobic Bio media for MBBR Tank Minimum Specific Surface Area of 500 m2/m3, Voidage - 95%, MoC: Virgin PE (Preferably Imported), Type - Cylindrical,Size: 25mm X12mm

3

-

-

... More
od92647/2022_2023 : Supply, Providing in Position, Testing & Commissioning of tube settler media in secondary settling tank.Minimum Specific (1.1mm thick PVC of unequal hexagonal chevron shape)

12

-

-

... More
od92656/2022_2023 : Supply, Installation,Testing & Commissioning of Electronic metering pumps Diaphragm Type Electronic Dosing Pump, MoC: PP, Foot Valve, Suction/Discharge LDPE Tubing, Strokes: Manually Regulated,Pressure: 0.0-3.5 kg/cm2, PE Storage Tank - 50 L and all accessoriescomplete.

1

-

-

... More
od92701/2022_2023 : Supply, Installation,Testing & Commissioning of Sludge Transfer Pump Non Clog Self Priming Type with back pull out design, MoC: CI,Packing - Non asbestos PTFE gland, Capacity 3 m3/Hr, Head - 10 m,Power- 1.0 HP, in a configuration of 1 Working with No Standby

1

-

-

... More
od92707/2022_2023 : Supply, Installation,Testing & Commissioning of Filter Feed Pumps MoC: Cast Iron, Duty: Continuous, Packing: Mechanical Seal, with a Flow Rate of min 200 LPM or above at a Head >25 m In a configuration of 1 Working & 1 Standby, Power- 3.0 HP, with Outlet Pressure monitoring, Strainers, Recirculation Valves, Check Valves &all required accessories etc. Complete

1

-

-

... More
od92721/2022_2023 : Supply, Installation,Testing & Commissioning of Pressure Sand Filter Working Pressure : 2.5 - 3.0 Bar, MoC: MS, Flow Rate: 8 - 10 m3/hr, Media Type: Sand & Pebbles, Diameter – 900mm, Height -1800mm, Process Connection - T&B, Valve type: valve assembly, with Inlet & Outlet Pressure monitoring, Hand Valves and all required accessories etc. Complete

1

-

-

... More
od92731/2022_2023 : Supply, Installation,Testing & Commissioning of Activated Carbon Filter Working Pressure : 2.5 - 3.0 Bar, MoC: FRP Composite, Flow Rate: 8 - 10 m3/hr, Media Type: Activated Carbon with Silex and Pebbles,Diameter – 900mm Height - 1800mm, Process Connection -T&B, Valve type: Multiport Valve -2", with Inlet & Outlet Pressure monitoring, Hand Valves and all required accessories etc. Complete

1

-

-

... More
od92752/2022_2023 : Supply, Installation,Testing & Commissioning of Electrical control panel:Automatic Operation All Switch gear- MCB, OLR, Single Phase Preventer, H/L Protection,Volt meter, Push Button, Indication Lamp ,TOD energy meter, flow meter etc of approved Make for Level based On-off Control Valves provided with float switch etc.

1

-

-

... More
od92736/2022_2023 : Supply, Installation,Testing & Commissioning of Electrical Cables considering a plant room with in 5 m nearby STP.Cables of approved make 4Core 10 mm2, Aluminium Armored Cable, 2.5 mm2- Flexible Cu Cable, 1.5 mm2-Cu Cable Flexible

1

-

-

... More
od92735/2022_2023 : Supply, Installation, Testing & Commissioning of plumbing interconnections considering a plant room with in 5 m nearby STP Airline Header: GI/MS, Air line after header UPVC-ASTM,Pressurized Water & Wastewater lines - UPVC-ASTM, Overflow Conduits / Gravity Lines – PVC 10 kg/cm2, Ball Valves - UPVC, Gate & Globe Valves – Brass,Slotted Chanel & Rod – GI

1

-

-

... More
od92734/2022_2023 : Liaising Works & Engineering Consultancy(free of cost) – if required Consent to Operate from KSPCB, Preparation of Installation and as built drawings for the Project, SOPs, Operating Manuals and Detailed Engineering

1

-

-

-

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

552.96

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

345.6

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

19.7

-

-

... More
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level

131.41

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

25.1

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

676.2

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

105.34

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

15768.72

-

-

... More
5.34.1 : Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).

131.41

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

831.93

-

-

... More
22.6 : Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured)

831.93

-

-

... More
19.32.1 : Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

2

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

421.55

-

-

... More
od55498/2022_2023 : :Providing heavy duty FRP manhole cover and frame of size 75cmx75cm internal<br>dimension with load<br>bearing capcity of 2.5 tonne made of polyster resin , fibre glass and fillers of<br>approved quality fixing in<br>correct line and level as directed by Engineer-in-charge

22

-

-

... More
STP Plant room

-

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

4.35

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

2.5

-

-

... More
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

3.05

-

-

... More
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level

8.1

-

-

... More
5.34.1 : Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).

8.1

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

1.73

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

59.22

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

10.34

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

1058.4

-

-

... More
od55975/2022_2023 : Solid block masonry using pre cast Fly ash solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.

13.42

-

-

... More
13.13 : 12 mm cement plaster 1:2 ( 1 cement : 2 stone dust)

302.88

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

455.58

-

-

... More
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

102.18

-

-

... More
13.83.2 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats

111

-

-

... More
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

28.8

-

-

... More
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

21.89

-

-

... More
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness

9

-

-

... More
od55532/2022_2023 : Providing and fixing Aluminium composite panel 4mm thick for aluminium doors with necessary screws, beedings etc complete<br>

2.52

-

-

... More
9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc

90

-

-

... More
od55685/2022_2023 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:<br>150x10 mm

2

-

-

... More
od55686/2022_2023 : Providing and fixing SS lock of size suitable for glass door with SS screws etc. complete as per direction of Engineer-in-Charge.

2

-

-

... More
od55687/2022_2023 : Providing and fixing SS H handle of size with SS screws etc. complete as per direction of Engineer-in-Charge.

1

-

-

... More
9.71.2 : Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete:100x60x2.50 mm

4

-

-

... More
9.82 : Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.

2

-

-

... More
22.6 : Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured)

39.84

-

-

... More
od40686/2024_2025 : Providing of good Quality Heavy Duty Wall Supported type ALUMINUM LADDER Made<br>from 10<br>SWG<br>Aluminum Alloy ""C"" Section size - 66 x 33 x 3.15 mm, Rung - 25.4 mm Fluted type<br>fixing<br>correct line<br>and level as directed by Engineer-in-charge

4734

-

-

... More
WATER TREATMENT PLANT-12000lph

-

-

-

... More
od66973/2022_2023 : Supplying, installing, testing and commissioning approved make Filter Feed pump for feeding water to the Filtration Plant including all required suction and delivery piping & valving, pressure guages etc complete. MoC of the pump shall be CI, Configuration 1W+1S.<br>Flow rate = 15000 Litres/Hr<br>Head: 30 m<br>Power :5 HP (VTC)

1

-

-

... More
od66981/2022_2023 : Supplying, installing, testing and commissioning approved make Raw Water Iron Removal filter with necessary Accessories complete with Frontal Piping, valves, suitable supports for mounting pressure gauges, orifice plates. The cost of filter shall also include initial charge of underbed & multi -grade filter media to suit the requirement etc. complete as per standards.<br>Max flow rate = 15000 Litres/Hr<br>Max working Pressure = 3.5 kg/sqmm.<br>Size: 42 inch Dia X 72 " Height<br>MoC: FRP<br>

1

-

-

... More
od66985/2022_2023 : Supplying, installing, testing and commissioning approved make Raw Water Pressure sand filter with necessary Accessories complete with Frontal Piping, valves, suitable supports for mounting pressure gauges, orifice plates. The cost of filter shall also include initial charge of underbed & multi -grade filter media to suit the requirement etc. complete as per standards.<br>Max flow rate = 15000 Litres/Hr<br>Max working Pressure = 3.5 kg/sqmm.<br>Size: 42 inch Dia X 72 " Height<br>MoC: FRP<br>

1

-

-

... More
od66989/2022_2023 : Supplying, installing, testing and commissioning approved make Raw Water Activated carbon filter with necessary Accessories complete with Frontal Piping, valves, suitable supports for mounting pressure gauges, orifice plates. The cost of filter shall also include initial charge of underbed & multi -grade filter media to suit the requirement etc complete as per standards.<br>Max flow rate = 15000 Litres/Hr<br>Max working Pressure = 3.5 kg/sqmm.<br>Size: 42 inch Dia X 72 " Height<br>MoC: FRP<br>Media: Activated Carbon: 1100 IV<br>

1

-

-

... More
od67021/2022_2023 : Supplying, installing, testing and commissioning approved make Electronic dosing system for dosing Chlorine into the Treated water with pre - set dosage based on the quantity of water. The Dosing system shall consist of Electronic dosing Pump with positive displacement type with adjustable stroke length and frequency. The quoted rate shall also include FRP/HDPE chemical solution tank, necessary electricals etc., complete to make the operation automatic.<br>Capacity - 6 to 12 LPH<br>Maximum head: 4 Bar<br>Power : VTC<br>MoC of wet parts: PP<br>Chemical Tank Capacity: 50 L

1

-

-

... More
od67025/2022_2023 : Supplying, installing, testing and commissioning Electrical Control Panel Suitable for Auto/Manual operation. The panel shall have Switch gear, MCB, OLR, Single Phase Preventer, H/L Protection, Push Button, Indication Lamp etc. of approved make.

1

-

-

... More
od67037/2022_2023 : Supplying, installing, testing and commissioning approved make Treated Water Transfer Pump including all required suction and delivery piping & valving, pressure guages etc complete. MoC of the pump shall be CI, Configuration 1W+1S<br>Flow rate = 15000 Litres/Hr<br>Head: 25 m<br>Power :3 HP

1

-

-

-

-

-

... More
od62204/2022_2023 : Supply, Installation,testing and commissioning of 3.6 mm fixed lens ,2MP , IR Dome camera 0 lux, 120 db WDR POE and vandal proof with all connectors and necessary accessories for mounting in True/false ceiling

52

-

-

... More
od62205/2022_2023 : Supply, Installation,testing and commissioning of Varifocal Dome Camera with 2 MP 0lx, built-in IR LED,120DB WDR , 2.8-12 mm POE,Vandal proof with all connectors and necessary accessories for mounting on true/false ceiling

9

-

-

... More
od62206/2022_2023 : Supply, Installation, testing and commissioning of Outdoor weatherproof camera Varifocal Bullet type with 2 MP 0lx, built-in IR LED,DWDR , 2.8-12 mm POE ,IP 67 ,Vandal proof with all connectors and necessary mounting accessories for external areas.

15

-

-

... More
od62207/2022_2023 : Supply, installation, testing and commissioning of 32 Channel Network Video Recorder Supports 32 channels 1080p resolution video recording at real time, NVR ONVIF , Recording resolution of Max 5MP, Minimum of 200Mbps of recording, should support dual video output,H265+, H.265,H.264, MJPEG Compression .video playback / relay at real time

3

-

-

... More
od63865/2022_2023 : Supply, installation, testing and commissioning of 64 Channel Network Video Recorder Supports 64 channels 1080p resolution video recording at real time, NVR ONVIF , Recording resolution of Max 5MP, Minimum of 200Mbps of recording, should support dual video output,H265+, H.265,H.264, MJPEG Compression.video playback / relay at real time

1

-

-

... More
od63866/2022_2023 : Supply, installation, testing and commissioning of HDD for cameras recording at 1080p @ 10fps for 30 days 24 hours - 6 TB

3

-

-

... More
od63867/2022_2023 : Supply, installation, testing and commissioning of workstation with Intel I7 or above, 8GB ram and 2TB HDD. with Dual Output Graphics Card. Same system will be used for Access control. The system shall come with video manager software for interacting with all cameras including all accessories.

1

-

-

... More
od63868/2022_2023 : Supply, Installation, Testing and Commissioning of LED Monitor 40" with all required accessories. HDMI cable of length 5m should be provided.

6

-

-

... More
PA SYSTEM

-

-

-

... More
od62602/2022_2023 : Supply & Installation of ceiling mount 6/9W Speaker for PA system

58

-

-

... More
od62603/2022_2023 : Supplying, installing, testing and commissioning Audio booster Amplifier 240 Watts RMS, complete with Speaker wires and RGB connectors for Integrated Music & PA system

1

-

-

... More
od62604/2022_2023 : Supplying, installing, testing and commissioning Audio booster Amplifier 120 Watts RMS, complete with Speaker wires and RGB connectors for Integrated Music & PA system

1

-

-

... More
od62605/2022_2023 : Supply & Installation of Master Controller for managing and controlling upto 6 zone should be able to integrated with FAS

1

-

-

... More
od62606/2022_2023 : Supply & Installation of 6 zone call station with mic

1

-

-

... More
od62607/2022_2023 : Supply & Wiring of Speaker system using 2 core of 1.5sqmm PVC insulated copper FRLS unarmoured cable

910

-

-

... More
od62608/2022_2023 : Supply, installation, testing & commissioning of Audio player with DVD/USB/FM connectivity option for playing music<br>

1

-

-

... More
PASSIVE

-

-

-

... More
od62613/2022_2023 : Supplying and drawing of UTP 4 pair LSZH F/UTP CAT6 Cable in the existing surface/ recessed Steel/ PVC conduit as required

5500

-

-

... More
od62614/2022_2023 : Supply, Installation, Testing and Commissioning of 24 Port Cat6 Patch Panel with all accessories loaded

12

-

-

... More
od62615/2022_2023 : Supply, fixing, testing and commissioning of Cable Manager

12

-

-

... More
od62616/2022_2023 : Supply, fixing, testing and commissioning of CAT6 Patch Cable - 2 Meter as required for complete installation.

100

-

-

... More
od62617/2022_2023 : Supply, fixing, testing and commissioning of CAT6 Patch Cable - 1 Meter as required for complete installation

150

-

-

... More
od62618/2022_2023 : Supply, fixing, testing and commissioning of CAT6 Information Outlets for Data with faceplate, Keystone Jack, faceplate, baseplate and GI mounting box. as required for complete installation

96

-

-

... More
od62619/2022_2023 : Supply, fixing, testing and commissioning of Keystone jack for data outlets (for Camera) as required installation

82

-

-

... More
od62620/2022_2023 : Supply, Installation, Testing & commissioning of 6 Core Fibre Cable Single Mode OS2 , 9/125/250 µm

260

-

-

... More
od62621/2022_2023 : Supply, Installation,Testing & commissioning of 6 Port LIU, 19" rackmount, with adaptors, Swing-out splicetray in 1U Size. Should have front access for easy splice & patch management. Fuly loaded with SC SM Pigtails & adapters for all the cores.

2

-

-

... More
od62622/2022_2023 : Supply, Installation,Testing & commissioning of 12 Port LIU, 19" rackmount, with adaptors, Swing-out splicetray in 1U Size. Should have front access for easy splice & patch management. Fuly loaded with SC SM Pigtails & adapters for all the cores.

3

-

-

... More
od62623/2022_2023 : Supply, Installation, Testing & commissioning of Fiber optic patch cords SM(SC to LC PC) - 50/125 - 1 Meter

22

-

-

... More
od62624/2022_2023 : 19", 12U 500MM wide x 550MM Depth Wall Mount Networking Rack with Front Glass Door, Horizontal Cable Manager - 2 Nos, Cantilever Shelf - 1 No, Horizontal PDU 6X5Amps - 1 No, Cooling Fan - 2 Nos, Hardware Screws and all other required accessories

2

-

-

... More
od62625/2022_2023 : 19", 22U 600 M M Wide X 800 M M Depth Floor Mount Networking Rack with Front Perforated Convex Door, Rear Perforated SPLIT Doors, Side Openable Panels, Castors, Heavy Duty Shelf - 1 No, Horizontal Cable Manager - 2 Nos, Cantilever Shelf - 1 No, Vertical PDU 12X5Amps - 1 No, Fan Housing Unit with 4 Fans - 1 Set, Mounting Hardware Screw sand all other required accessories

1

-

-

... More
od62626/2022_2023 : 19", 42U 800MM Wide X 1000MM Depth Floor Mount Server Rack with Front Perforated Convex Door, Rear Perforated SPLIT Doors, Side Openable Panels, Castors, Heavy Duty Shelf - 1 No, Horizontal Cable Manager - 2 Nos, Cantilever Shelf - 1 No, Vertical PDU 12X5Amps - 1 No, Fan Housing Unit with 4 Fans - 1 Set, Mounting Hardware Screws And all other required accessories

1

-

-

... More
od62627/2022_2023 : Supply, Installation, Testing & Commissioning of Single port coaxial TV outlet with faceplate, baseplate and GI mounting box.

15

-

-

... More
od62628/2022_2023 : Supplying and drawing coaxial TV cable RG6 grade, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/ PVC conduit as required.

630

-

-

... More
SWITCHES

-

-

-

... More
od62641/2022_2023 : Supply, Installation, Testing & Commissioning of 24 port PoE with 1G copper uplink module loaded and all related termination accessories as per vendor specific System requirement including minimum 2 nos fibre optic uplink.

5

-

-

... More
od62642/2022_2023 : Supply, Installation, Testing & Commissioning of 24 port 10/100/1000 Base-T network Switch with 1G copper uplink and all related termination accessories as per vendor specific System requirement including minimum 2 nos fibre optic uplink.

7

-

-

... More
od62643/2022_2023 : Supply, Installation, Testing & Commissioning of 24 port Core switch loaded with all the necessary Uplink Modules

1

-

-

-

-

-

... More
od62653/2022_2023 : Supply, installation, testing and commissioning of Digital master console phone with 5 navigation keys with necessary connection as required for complete installation.

1

-

-

... More
od62654/2022_2023 : Supply, installation, testing and commissioning of Digital phone with necessary connection as required for complete installation as directed by the engineer in charge

2

-

-

... More
od62655/2022_2023 : Supply, installation, testing and commissioning of Basic user phone with necessary connection as required for complete installation as directed by the engineer in charge

91

-

-

... More
od62656/2022_2023 : Supply and fixing 30 pair 0.51 mm dia telephone tag block "Krone or equivalent make" with termination box and enclosure including clamping on wall making good the damages complete as required

3

-

-

... More
od62657/2022_2023 : Supply and fixing 20 pair 0.51 mm dia telephone tag block "Krone or equivalent make" with termination box and enclosure including clamping on wall making good the damages complete as required

1

-

-

... More
od62658/2022_2023 : Supply and laying 20 pair telephone cable

35

-

-

... More
od62659/2022_2023 : Supply and laying 30 pair telephone cable

130

-

-

... More
od62660/2022_2023 : Supply and laying 100 pair telephone cable

5

-

-

... More
od62661/2022_2023 : Supply and installation of modular type telephone socket outlet mounted in separate GI box including supply of modular mounting box, telephone socket covering with modular, baseplate and coverplate giving connection etc as required

93

-

-

... More
od62662/2022_2023 : Supply, Installation, Testing and Commissioning of "PBX with 100 Analog extensions expandable up to 50 ports (Extensions/Trunks) , 5 Digital IP Extensions and 2 SIP License with maximum of 30 concurrent<br>calls Network Interface: 1×10/100M LAN port 2 PRI interface, RAM: DDR3 1GB, Power Consumption:<br>12V, 10W Maximum, Failover Function (optional), Web Interface, Call Dashboard, DISA, IVR, Call<br>Hunt, rack mountable etc. Features:Room monitoring from outside, Warning Message during, night mode, Remote Inspection, with auto-emergency call, Sensor Connectivity with auto emergency, call and warning message sending, Built-In Auto Answer, (Standby mode) during night, mode, Voice Mail Integration. Paging Announcement. Programmable Function Keys complete as required.

1

-

-

... More
od62663/2022_2023 : Supply and fixing 100 pair 0.51 mm dia telephone tag block "Krone or equivalent make" with termination box and enclosure including clamping on wall making good the damages complete as required

1

-

-

... More
od62664/2022_2023 : Supplying and drawing 2 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,<br>unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.

2030

-

-

... More
NURSE CALL SYSTEM

-

-

-

... More
od62666/2022_2023 : Supply, Installation, Testing & Commissioning of Nurse Station Terminals with all the necessary connection accessories for the installation.

7

-

-

... More
od62667/2022_2023 : Supply, Installation, Testing & Commissioning of Patient Bedside unit - with nurse call switch, call acknowledgement & without speech provisions.

73

-

-

... More
od62668/2022_2023 : Supply, Installation, Testing & Commissioning of Toilet Pull Cord with all the accessories required.

15

-

-

... More
od62669/2022_2023 : Supply, Installation, Testing & Commissioning of Dome Light with all the accessories required.

22

-

-

... More
od62670/2022_2023 : Supply, Installation, Testing & Commissioning of Workstation with NCS management software with Intel i7 Processor, 8GB RAM, 2TB HDD, MS Office Suite Latest version, 24 Inch Monitor, Keyboard & Mouse and all the necessary accessories

1

-

-

... More
ACCESS CONTROL SYSTEM

-

-

-

... More
od62676/2022_2023 : Supply and Surface laying of 2 CoreX 1.0 Sq.mm unarmoured shielded FRLS PVC Insulated Cable - controller to exit switch

50

-

-

... More
od62677/2022_2023 : Supply and Surface laying of 8 CoreX 0.75 Sq.mm unarmoured FRLS PVC Insulated Cable - Reader to Controller

50

-

-

... More
od62678/2022_2023 : Supply and Surface laying of 4 Core X 0.75 Sq.mm unarmoured FRLS PVC Insulated Cable - for controller to Electromagnetic lock

15

-

-

... More
od62679/2022_2023 : Supply, Installation, Testing and Commissioning of licensed security management software with Time Attendance and Access including programming of access cards

1

-

-

... More
od62680/2022_2023 : Supply, Installation, Testing and Commissioning of Single Leaf Electromagnetic Lock with Magnetic Contact

15

-

-

... More
od62681/2022_2023 : Supply, Installation, Testing and Commissioning of Double Leaf Electromagnetic Lock with Magnetic Contact

5

-

-

... More
od62682/2022_2023 : Supply, Installation, Testing and Commissioning of Exit push button

9

-

-

... More
od62683/2022_2023 : Supply, Installation, Testing & Commissioning of Mifare cards with below specifications as minimum and all the necessary accessories<br> - Type - Mifare 13.56<br> - Construction - PVC<br> - Transaction Time - <110ms<br> - Memory - 1K

100

-

-

... More
od62684/2022_2023 : Supply, Installation, Testing & Commissioning of Smart card based access control reader with all required specifications and all the necessary accessories

9

-

-

... More
od62685/2022_2023 : Supply, Installation, Testing & Commissioning of Door Controller with below specifications as minimum and with enclosure, power supply and all the necessary accessories - 2 Door Integration - Onboard TCP/IP Port - 32 Bit Architecture or better - Cardholder - 50,000 Transaction -40,000 - IOs - 8/4 - Readers - 2

9

-

-

... More
MISCELLANEOUS

-

-

-

... More
od62688/2022_2023 : Supplying and installing following size of perforated GI cable trays with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with GI suspenders including bolts & nuts, required bends, tees, reducers etc as required.<br><br>150 mm width X 50 mm depth X 1.6 mm thickness

210

-

-

... More
od62689/2022_2023 : Supplying and installing following size of perforated GI cable trays with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with GI suspenders including bolts & nuts, required bends, tees, reducers etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness

240

-

-

... More
od62690/2022_2023 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. <br>20 mm

2200

-

-

... More
od62691/2022_2023 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm

1845

-

-

... More
TOKEN/ QUEUE MANAGEMENT SYSTEM

-

-

-

... More
od62694/2022_2023 : Supply, Installation, Testing & Commissioning of Touch screen Token/ Vending Machine

2

-

-

... More
od62695/2022_2023 : Supply, Installation, Testing & Commissioning of 42 Inch Token Display Unit with media player and all the necessary accessories to complete the system.

2

-

-

... More
od62696/2022_2023 : Supply, Installation, Testing & Commissioning of queue Calling Software Client

10

-

-

... More
od62697/2022_2023 : Supply, Installation, Testing & Commissioning of Token Management software with server machine

1

-

-

... More
Passenger lift

-

-

-

... More
od58371/2022_2023 : Supply, installation, testing and commissioning of 24 persons staff lift; with machine room; 1m/s speed<br>serving 4 stops having well size of 2.37 X 3.02 M; one front opening with automatic power doors; complete<br>with all standard features like direction and position indicators in car and all floors, full height infrared door<br>curtain, pit ladder and safety curtain, inverter based emergency light and alarm, Open and Close door . button in car, Fan switch in car, handrail on the rear side, mirror in the rear side, emergency rescue<br>device, load weighing sensor, fireman drive with 2 ph operation, dedicated intercom, lift announcement<br>system, 1 hour fire rating

1

-

-

... More
od58372/2022_2023 : Supply, installation, testing and commissioning of 24 persons passenger/bed lift; with machine room; 1m/s speed. serving 4 stops having well size of 2.49 X 3 M; one front opening with automatic power doors; complete. with all standard features like direction and position indicators in car and all floors, full height infrared door<br>curtain, pit ladder and safety curtain, inverter based emergency light and alarm, Open and Close door<br>button in car, Fan switch in car, handrail on the rear side, mirror in the rear side, emergency rescue<br>device, load weighing sensor, fireman drive with 2 ph operation, dedicated intercom, lift announcement<br>system, 1 hour fire rating

2

-

-

... More
Dumbwaiter

-

-

-

... More
od64150/2022_2023 : Supply, installation, testing & commissioning of 150kg dumbwaiter, 0.6m/s speed serving 2 stops. Well size is 1300 mm W X 1000 mm D.

2

-

-

... More
50KW solar power generating System

-

-

-

... More
od325168/2023_2024 : Supply, Installation, testing and commisioning of 50KW solar power generating System including solar accessories, fabrication & commissioning etc complete. The cost includes KSEB application and Registration Fee, Solar Meter and Net Meter including testing activities if required or with test certificate, Electrical Inspectorate charges, Harmonics test and its co-ordination and all the laisoning activities required for grid connectivity approval of the Solar Power Plant.Transportation, Loading and Unloading charges are included. All civil works shall be measured in the relavent BOQ items. <br>

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.