Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 22,300Document Cost
₹ 2,100Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_UNILE_690364_1Bid Award Id
ViewTender No
PMC/MKTG/012A/24-25Tender Authority
United Electrical Industries Limited ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 5 NOS OF 8 METER MINI MAST WITH 5X150 WATT LED FLOOD LIGHT AT VARIOUS LOCATION IN NATTIKA LAC AND 10-METER-HIGH MAST WITH 6X200 WATT LED FLOOD LIGHT AT NATTIKA LAC
BOQ Items
... More
90.14.1.2 : Fabrication, Supply,installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.br
Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and Fabrication of MV Panel board using 1.6 mm CRCA sheet,Powder coated (excluding base frame).
10
-
-
... More
90.14.3.2 :Supply and providing heavy duty 'A' section neoprene gasket in the panel board U' scetion rubber beeding suitable for 1.60/2.00mm sheet
20
-
-
... More
90.14.5 :Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board.
50
-
-
... More
od39856/2024_2025 : Supply and fixing of 25A 2 Pole AC 1 rated power contactor, 25A Connector, Digital timer, Suitable Copper socket, 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable, 1.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable, OBO Bettermann makes V25-B+ C/1+ NPE (switching/lightning protection) for single-phase protection.
5
-
-
... More
od39756/2024_2025 :Supply and fixing HRC fuse base of 20/32A using suitable nut and bolt, 32A 2-way neutral links mounted on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable.
5
-
-
... More
2.14.2 :Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
5
-
-
... More
2.10.3 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
5
-
-
... More
2.10.1 :Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
5
-
-
... More
2.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
5
-
-
... More
90.6.5.11 :Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50sq mm
215
-
-
... More
5.3 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and
providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
5
-
-
... More
90.16.4.2 :Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25x3 mm GI strip
140
-
-
... More
90.16.1.3 :Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 3.15 mm copper conductor(10SWG)
40
-
-
... More
90.16.5.3 :Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 MM(10SWG)
14
-
-
... More
90.12.5.3 :Supply and laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm
55
-
-
... More
90.12.9.2 :Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench 50/38 mm or nearest size.
70
-
-
... More
9.1.2 :Suppplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
10
-
-
... More
Fabrication Supply coveyance and installation of granite name board indicating the cost
involved the commencement completion and inaugration date.
5
-
-
... More
Supply and fixing of Name Board with Angles, Flats, Square pipe, ACP Sheet including Nut
5
-
-
... More
CIVIL WORKS - minimast light
-
-
-
... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
7
-
-
... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
0.5
-
-
... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
18.2
-
-
... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
139.86
-
-
... More
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
2.61
-
-
... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
6.05
-
-
... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
4.35
-
-
... More
Installation of 10 Mtr high Mast System
-
-
-
... More
90.15.2.2 :Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/two sections of hot dip galvanised GI sheet 70mm top diameter, 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16 mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm dia double drum winching system w and including round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box and lighting spikes with single phase operation power tool installed inside the base compartment including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc, complete 10 Meters
1
-
-
... More
90.15.4.11 :Installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
6
-
-
... More
od39872/2024_2025 :Supply and Installation of Twin unit aviation LED obstruction light with stand yellow-painted die-cast aluminium alloy housing, red coloured polycarbonate dome and BC /EC lamp holders suitable for LED lamp
1
-
-
... More
1.17.3 :Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
44
-
-
... More
od39873/2024_2025 : Earthing with G.I. earth plate 300 mm X300 mm X 6 mm thick including wateringpipe of 2 metre long etc. with the earthing compound as required.<br>
2
-
-
... More
90.16.2.3 :supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.32 mm dia G.I pipe ( medium class)
15
-
-
... More
od39875/2024_2025 :Supplying and laying 25 mm X 3 mm G.I strip at 0.50 metre below ground including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required
22
-
-
... More
90.12.1.41 :Supply and laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 16 sq mm
33
-
-
... More
9.1.33 :Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
3
-
-
... More
od39876/2024_2025 : Supply of Box for Panel Board made out of Sheet Moulding Compound (560 x 280x 150 mm size) Surface mounted or recess-in wall (Indoor/Outdoor Use) One-piece moulded SMC base and SMC door with internal hinges. Knockout for wire entry, earthing bolt.<br>
1
-
-
... More
od39877/2024_2025 : Fabrication and fixing of the Panel Board Stand with 2 legs made up of B class GI<br>pipe 32mm dia 1.8mtr. length. 32 mm dia G.I pipe ( medium class)<br>
1
-
-
... More
od39878/2024_2025 :Supply of Meter Box made out of Sheet Moulding Compound (430 x 265 x 170 mm size) Surface mounted or recess-in wall (Indoor/Outdoor Use) One piece<br>moulded SMC base and SMC door with internal hinges. Knockout for wire entry, earthing bolt and earthing of the meter box.<br>
1
-
-
... More
od39879/2024_2025 : Fabrication and fixing of the Meter Box. Stand with 1 leg made up of GI pipe<br>40mm dia 2.5mtr. length.<br><br>
1
-
-
... More
od39871/2024_2025 : Fabrication and installation of Granite name board indicating the cost involved, the commencement, completion and inauguration date etc.
1
-
-
... More
od39874/2024_2025 :fixing of name board with angles , flats,square pipe, ACP sheet including nut and bolts, 4 no.s per mast ,2sqmm in area
1
-
-
... More
Civil works- 10 Mtr high Mast System
-
-
-
... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
4.9
-
-
... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
0.82
-
-
... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
0.33
-
-
... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
8.44
-
-
... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
113.33
-
-
... More
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
2.21
-
-
... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
2.24
-
-
... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
2.74
-
-