Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 63,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
E-tender For The Electrification Work At The Mills For
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_TCSM_272199_4Tender No
TCSM/Electricalwork/2019-20/01Tender Authority
Trichur Cooperative Spinning Mills Limited ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Installation, Testing And Commissioning Of 12 KV 800A 26.3KA for 3 sec VCB HT Panel - 1 Incomer + Three Outgoing as specified in Annexure B
1
-
-
Installation Testing and Commissioning of 2 nos.1600 kVA,11 KV/433 OLTC oil filled Transformer as shown in Annexure C - Note: This amount is including the rent of Crane for its installation.
2
-
-
Installation, Testing and commissioning of 400 kVAR APFC Panel as per Annexture E.
4
-
-
BUS DUCT FROM 1600 kVA TRANSFORMER TO MSB - 2500A LT Bus Duct: Installation and commissioning of 2500A Sandwich type Aluminium bus duct rated voltage 415V/690V, bus duct 2R x 150mm x 10mm Aluminum for phase and 1R x 150mmx10mm Aluminum for Neutral .For earthing two runs of 25mm x 6mmCu strip run along both sides including interconnections having ingress protection of IP 54 Necessary flexible links at both ends shall be included. The bus duct shall be complete with protective earth and necessary supports. External supports shall be provided. The bus duct shall confirm to IEC 60439/II and IS8623/II, as specified in ANNEXURE D. Note: The length of the bus duct is approximate. It may vary according to site condition & based on bus duct layout.
30
-
-
MAIN SWITCH BOARD - Installation ,Testing and commissioning of mill supplied 2500A MV panel board with circuit breakers, multifunction metering unit , RS485 port for communication etc., IP 54, vermin proof, floor mounted, free standing, cubicle construction as per the relevant one line diagram approved by Electrical Inspectorate and according to IS.5138, 3072, 1554, 2516, 7098(Part-1),2705 (Part III) 1964,3043,2384-1964, DIN EN ISO1520,2815&2409,DIN EN ISO 1520, 2815,&2409&9227NSS, IEC60255,,IS3231,IEC 60947-3/IS-8623,IEC 60947-2/IS13947-Part2. as per Annexture:F. The testing and commisioning shall be conducted in the presence of the Panel board supplied Commisioning Engineers.The conceptual Drawing TCSM/ 1L-003/20 is a guide line for the preperation of Electrical Drawings for submission to Electrical Inspectorate and approval.
1
-
-
SUB MAIN SWITCH BOARD-SMSB-1,2,3,4,5,6,7 & 8 - Installation testing and commissioning of MV panel board conforming to relevant Indian standards specified in Annexture F and as per the relevant one line diagram approved by Electrical Inspectorate . The testing and commisioning shall be conducted in the presence of the Panel board supplied Commisioning Engineers. The conceptual Drawing no’s TCSM/1L-004/20 to 11/20 is a guide line for the preperation of Electrical Drawings for submission to Electrical Inspectorate and approval.
8
-
-
SECONDARY SWITCH BOARD - SSB 1.1 TO 1.5, 2.1,6.1,6.2 -
Installation testing and commissioning of MV panel board conforming to relevant Indian standards specified in Annexture F and as per the relevant one line diagram approved by Electrical Inspectorate . The testing and commisioning shall be conducted in the presence of the Panel board supplied Commisioning Engineers. The conceptual Drawing no’s TCSM/1L-0013/20 to 19/20 is a guide line for the preperation of Electrical Drawings for submission to Electrical Inspectorate and approval. Note: The SSB 1.1 shall be supplied by the Vendor/Supplier of the relevant equipments..
8
-
-
HT CABLE - Supply, laying and clamping of 3nos. 11/11KV grade XLPE cable (UE) of the following sizes using clamps fabricated from 20 x 3 mm MS flat, spacing of clamps not exceeding 60 cms as per Annexture G Recommended cable:-Gloster, Poly Cab, Finolex
Note:- Where ever possible, the cable shall be laid over runways(ladders) especially when laid in the concreted trenches within the building with a minimum separation of at least overall diameter of each cable laid. The laying and bending of the cable shall be as per IS7098(PartII) 1988 & IS 1255-1983. The Testing of cable shall be conducted as per IS 10810. Note: The cable shall be tested for its continuity and insulation before and after laying as per relevant standard and got confirmed for its quality and integrity.
1
-
-
1 R X 3 core x 185 sq mm cable from HT structure consumer side to HT VCB panel incomer.
15
-
-
Termination at both ends
2
-
-
2 R X 3 core x 185 sq mm cable from HT VCB Panel outgoing circuit 1 & 2 to 1600kVA Transformers 1 & 2 ( Primary Side).
30
-
-
Termination at both ends
4
-
-
LT CABLE FROM MSB TO VARIOUS SMSB 1,2,3,4,5,6,7 & 8 - Supplying & laying of XLPE insulated and XLPE sheathed armored aluminum power cable of 1.1 KV grades of the following sizes through the soil as well as through existing and new trenches inside Plant/Mill as per IS 7098 (Part I.) 1988. The cable layout details and schedule shall be made available to the awarded contractor later. All the cable shall be supplied as per IS 7098-P1-1988 and layed as per IS 732-1989 & IS 1255-1983 . For termination of cable use proper size compression type tubular terminal ends as specified in IS 8309-1993.
Note: The cable shall be tested for its continuity and insulation before and after laying as per IS 10810 and got confirmed for its quality and integrity.
1
-
-
2 X3.5 core X 400 sq mm LT cable 1.1KV XLPE Armored Cable (A2XFY)
670
-
-
Termination of 400 mm square cable at MSB & SMSB 1 TO 8
28
-
-
LT CABLE FROM SMSBs TO SSBs 1.1,1.2,1.3,1.4,1.5,2.1,6.1,6.2 & Humidification plant panels.- Note:-
1.All these cables are to be laid through the trenches within the Plant area (either new or existing) .As far as possible, the cables should be clamped on the runways/ cable ladders of suitable size, the latter fixed on the vertical side walls either horizontally and/ or vertically according to the site condition and switch Boards positions. The cables shall be bent as per relevant standard based on their overall diameters.
2. The cable shall be tested for its continuity and insulation before and after laying as per IS 10810 and got confirmed for its quality and integrity. 3.For termination of cable use proper size compression type tubular terminal ends as specified in IS 8309-1993. 4.All the cable shall be supplied as per IS 7098-P1-1988 and layed as per IS 732-1989 & IS 1255-1983
5. Recommended cables: Finolex,Poly cab, L&T
1
-
-
1X 3.5 core x 120 sq mm LT cable 1.1KV XLPE Armored Cable (A2XFY)
623
-
-
Termination at both ends
16
-
-
1X 3.5 core 300 sq mm LT cable 1.1KV XLPE Armoured Cable (A2XFY)
40
-
-
Termination at both ends
2
-
-
2X 3.5 core 185 sq mm LT cable 1.1KV XLPE Armoured Cable (A2XFY)
20
-
-
Termination at both ends
2
-
-
2X 3.5 core 95 sq mm LT cable 1.1KV XLPE Armoured Cable (A2XFY)
45
-
-
Termination at both ends
2
-
-
1X 3.5 core 70 sq mm LT cable 1.1KV XLPE Armoured Cable (A2XFY)
88
-
-
Termination at both ends
2
-
-
LT CABLE FROM SMSBs TO Equipment’s. Supplying & laying of XLPE insulated and XLPE sheathed armored cable from SMSB`s to Equipments. The cable shall be tested for its continuity and insulation before and after laying as per IS 10810 and got confirmed for its quality and integrity. All the cable shall be supplied as per IS 7098-P1-1988 and layed as per IS 732-1989 & IS 1255-1983
Recommended cables: Finolex,Poly cab, L&T
1
-
-
1X 3.5 core x 120 sq mm LT cable 1.1KV XLPE Armored Cable (A2XFY)
470
-
-
Termination at both ends
48
-
-
1X 3.5 core x 300 sq mm LT cable 1.1KV XLPE Armored Cable (A2XFY)
30
-
-
Termination at both ends
2
-
-
LT CABLE FROM SSBs TO the corresponding in built DBs of VARIOUS EQUIPMENTS provided by the Supplier/Vendor :-Supplying & laying of XLPE insulated and XLPE sheathed armored cable from SSB`s to Equipments. The cable shall be tested for its continuity and insulation before and after laying as per IS 10810 and got confirmed for its quality and integrity. All the cable shall be supplied as per IS 7098-P1-1988 and layed as per IS 732-1989 & IS 1255-1983
Recommended cables: Finolex,Poly cab, L&T
1
-
-
4 core 6 sq mm Copper cable (2XFY)
20
-
-
Termination at both ends
8
-
-
4 core 10 sq mm copper cable (2XFY)
400
-
-
Termination at both ends
66
-
-
CONTROL CABLE -Supply and laying of following sizes armored XLPE insulated Cu LT/control cables through existing/new cable trench/tray to the respective machineries from the DB of the supplied machine. All the cable shall be supplied as per IS 7098-P1-1988 and layed as per IS 732-1989 & IS 1255-1983. Recommended cable:Finolex,Polycab, Vguard
1
-
-
2CX1.5 Sq mm copper
115
-
-
2CX2.5 Sqmm copper
115
-
-
2CX4 Sqmm copper
115
-
-
4CX1.5 Sqmm copper
115
-
-
4CX2.5 Sqmm copper
115
-
-
4CX4 Sqmm copper
115
-
-
9CX2.5 Sqmm copper
115
-
-
12CX1.5 Sq mm copper -
115
-
-
Note:- The cable shall be tested for its continuity and insulation before and after lying as per relevant standard and got confirmed for its quality and integrity. The length shown are approximate. The contractor has to quote the rate per meter.
1
-
-
Checkered Plates - Supply and placing chequer plate over each manhole in front of all switch boards as well as at every 8 m (25ft) on the existing and new able trenches constructed by the civil Contractor as well as on the front and rear sides of all switch Boards.
1. Supply of 1.5m (L)x1m (B)x0.006m (T) mild steel chequer plate.
2. Fitting charges of 6mm thick chequer in each man hole of 1.5m x0. 60m and front & rear sides of all Switch Boards(Both HV and MV) (See cable trench and switch board lay out )Note:- Each cover should be provided with suffient lifting clamps which will be having moving slot within the plate so that the clamps will be in flush with the plate when not in use.
1
-
-
STRAIGHT JOINT FOR LT CABLE - Supply and making straight through joint for 400sq mm 1.1 KV grade XLPE Armoured cable (A2XFY). The cale jointing kit shall cable consisting of jointing compound, hardener, plastic mould, adhesive-cum-solvent, fast curing epoxy, sponge sheet, mould holding clips, earth continuity connection, epoxy cast spacer, PVC (NA) tapes etc. as required. The cable jointing kit and accesories including methords of jointing shall confirm to IS-13573 (Part –I):2011
8
-
-
EARTHING
1
-
-
Supply and providing plate earthing as per IS 3043 with 1200x1200x12 mm GI/CI earthplate,50 mm GI watering pipe fixed to the earth plate with 25x 3mm GI clamps, I funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone 910 cm thick ), brick work in cement mortar 1: 6 , plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick , ( the finished inside dimension shall be 450 x 450 x 450 mm ) but excluding test joint, earth continuity conductor to the plate, and covering at the top.( In hard soil). Note: The quantity of plate earthing shall be finalized after the earthing design is made based on the fault level of the supply system within the mill. Also see item-1 in the BOQ.
6
-
-
Supply and providing pipe earthling as per IS 3043 with 3.60 m long 40 mm dia B class GI pipe, GI funnel with weld mesh, filling required quantity of charcoal & salt including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm Brocken stone ( 10 cm thick ) ,brick work in cement mortar 1:6,plasteringthe surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick,( the finished inside dimension shall be300x300x300 mm) but excluding the test joint, earth continuity conductor to the plate, and covering at the top.( In hard soil) Note: The quantity of plate earthing shall be finalized after the earthing design is made based on the fault level of the supply system within the mill. Also see item-1 in the BOQ.
3
-
-
Supply and providing the following sizes of cast iron gully trap with covering at the top of the inspection chamber of the earth pit as required
1
-
-
450x450x10 mm cast iron gully trap with covering
6
-
-
300x300x10mm cast iron gully trap with covering
5
-
-
Supply and providing test joint for the earthling system using 2 No’s of the following sizes of strips including cutting and bending to the shape, drilling necessary holes and fixing to the watering pipe etc as required (in case of strip) and fixing firmly with plate test joint etc as required.
1
-
-
2x25x6mm tinned copper strip
6
-
-
2x25x3mm tinned copper strip
4
-
-
Supply and providing earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required.
1
-
-
25x6mm copper strip tinned at the point of contacts
50
-
-
4.00 mm bare copper conductor( SWG)
50
-
-
Supply and laying strips of the following sizes along with wiring/ cables and giving connection as required.
1
-
-
25x 3mm copper strip tinned at the point of contacts.
300
-
-
25x 6mm copper strip tinned at the point of contacts.
150
-
-
3.15 mm copper conductor (10 SWG)
150
-
-
Supply and laying the following sizes of strips laid 0.60 m below ground level including excavating trench of suitable size and refilling etc. as required (in hard soil). - .
1
-
-
25x 6 mm copper strip tinned at the point of contacts
350
-
-
4.00 mm copper conductor ( 8 SWG)
50
-
-
LIGHTING
1
-
-
Remove the existing lighting fixtures,conduits,wirings, related circuits and DB`s etc. in the mill area and power room area. Separate each item and keep them safely in a place as instructed by the mill authority for auction at later stage.
500
-
-
a)Preperation of General Lighting layouts from blow room area to post spinning area + power room as per lighting standards applicable to textile and milling areas &get them approved by the Electrical inspectorate and mill authority. The conceptual drawing no TCSM-LL-001 &TCSM-LL-002 may please be refered for preperation of the actual lighting. layout for the Inspectorate/KSEB approval and installation of all these lighting fixtures as per standard. Note: The lighing layout shown in the conceptual drawings are prepared based on SITRAguide lines.(South Indian Textile Reserch Association). If it is not accepted by electrical inspectorate, the contractor has to re design the lighting system according to relevent IS-6665-1972. b) Install new lighting fixtures with LED tubelights (supplied by the Mill) as per the aforesaid approved drawing from Blow room area to Post Spinning Area and Power room. (For details of wiring spec See item14 of NIT Pages 5&6of 34 and for light wiring see the conceptual drawing No.TCSM-LL-001 and the notes contained in it as guide line.).The conduit and fittings materials are PVC ISI Marked and medium type.
651
-
-
Installation of portable type 1 foot 9 watts LED Emergency lighting unit supplied by the mill as shown in the conceptual lighting layout TCSM-LL-001, TCSM-LL-002.
60
-
-
Installation of EXIT light supplied by the mill as shown in the conceptual lighting layout TCSM-LL-001, TCSM-LL-002.
15
-
-
a)Supply and install Industrial type power socket 20A DP(2P+E) with built-in RCBO cat #507820 IK08 Legrand or similar product. b) circuit wiring as per standard and based on allowable voltage drop and short cicruit level at the powerDB. Minimum size of cable and conduit shall be decided accordingly.(Please refer to Industrial Power Socket lay out vide Drwg.No.TCSM -PSL 001 as guide line only. The contractor has to prepare statutory circuit diagram and get it approved before doing the wiring.
57
-
-
MISCELLANEOUS
1
-
-
Supply and placing 2.5 mm thick and 1m wide electrical grade checkered type rubber mat to withstand 15 KV dielectric strength conforming to IS 2257 in front and rear sides of HT Panel, Control Panel and Transformers. (The actual length shall be decided at site.)
20
-
-
Supply and placing 2.5 mm thick and 1m wide electrical grade checkered type rubber mat to withstand 3.3 KV dielectric strength conforming to IS 5429/1969 in front and rear sides of all MV panels.
100
-
-
Supply and providing First Aid Chart duly framed and placed in conspicuous location for clear vision.
15
-
-
Supply route marker with 10 cm x 10 cm GI plate 5 mm thick with inscriptions there on bolted/welded to 35x35x 6 mm angle iron 60 cm long and fixing the same in ground as required
15
-
-
Supply and providing 5 Kg Dry chemical powder type fire extinguisher with hose and clamps including fixing it to the wall as required.
10
-
-
Supply and providing 9 liter capacity GI fire bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE" mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket / floor stand including making good the damages, color washing etc, as required.
5
-
-
Supply & Fabrication of MS Cable trays and supports duly painted - 1 coat of epoxy primer and 2 coats ofepoxy paint after removing completely all the rusts and oil if any. After painting each coat and on curing, the surface should be rubbed with fine sand paper of no.400 before applying the other coat.
1
-
-
Supply and erection of HTand LT danger boards on all switch Boards & elctrcal room and instruction sheets as required by the electrical inspectorate. All Switch Boards shall be sign written about their capacity, entry of incoming and outgoing cable details etc as specified by the Electrical Inspectorate .
1
-
-