Trichur Cooperative Spinning Mills Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Trichur Cooperative Spinning Mills Limited Tender

Works
Eprocure
Opening Date6 Aug 2021
Closing Date16 Aug 2021
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
H T CABLE TERMINATIONS: Supply and providing end termination for the following sizes of HT XLPE cables including all materials required for frim joints. (Heat shrinkable type, Raychom/ M Seal Make)----- 3Cx300 SQ.MM OUTDOOR

1

-

-

... More
3Cx300 SQ.MM INDOOR

5

-

-

... More
EMERGENCY OFF PUSH BUTTON:- Supply, Installation ,testing and commissioning of Lockable Push Button for Emergency OFF facility of the HT VCB Panel for the Incomer VCB. [Cable shall also be included, Out side Transformer Room-1, Out side Transformer Room-2 & I/C VCB]

3

-

-

... More
OUT DOOR CT/PT UNITS FOR SUPPLIERS METERING: Supply, installation, testing and commissioning of 11kV outdoor type CT/PT unit with, class 0.2S, 15VA CT with suitable ration as required as per KSEBL and 11kV/110V class 0.2S, 150VA PT on the existing DP structure with all necessary accessories for connecting 11kV lines, control cable, etc. as required. The existing CT PT Unit, Metering KIOSK and control cable shall be dismantled from the structure and stacked in stores as directed by the engineer in charge / consultant. The Unit shall be duly tested at the TMR section of KSEB and the certificates should be submitted to the concerned authorities for obtaining HT supply/ Regularised, as required.

1

-

-

... More
TOD METER - SUPPLIERS METERING]:- Supply, Installation ,testing and commissioning of a TOD meter for KSEB within HT Metering panel including connections from CT and PT etc. as per KSEB/ Suppliers recommendation. The Meter shall be duly tested at the TMR section of KSEB and the certificates should be submitted to the concerned authorities for obtaining HT supply, as required. [Make L&T; Trivector Meter Class 0.2s, Model ER300P Class 0.2s (Base Mounting) OR Equivalent. All statutory chargers shall be reimbursed from clients on production of proper receipts.

1

-

-

... More
TOD METER KIOSK [OUTDOOR]:- Supply, Installation, testing and commissioning of HT Out door Metering KIOSK/Panel with glass window and sufficient number of terminal connectors with 25% spares, for connections from CT and PT etc. as per KSEB/ Suppliers recommendation, Control fuses, etc. The KIOSK shall be made out of 2mm thick CRCA sheet steel, totally enclosed, IP 54, weather proof, with rain guard, undergone seven tank process, powder coated finish, earthing, entire civil work including suitable foundation and all mounting accessories as required complete as per the requirement of KSEBL.

1

-

-

... More
M. V PANELS/ DISTRIBUTION BOARDS- SSB#01 & SSB#02: [GENERAL SPECIFICATIONS:] Supply, installation, testing and commissioning of front operated free standing indoor cubicle type MV panel suitable for operation of 415V, 3 phase, 4 wire, 50Hz AC supply system and to with stand a short circuit level of 50kA rms symmetrical. The panel shall be made up of 14 SWG CRCA sheet with necessary anti corrosive treatment and shall be dust and vermin proof construction (IP 54) suitable for installation on floor. The panels shall be fully compartmentalised, duly rust inhibited, degreasing, zinc phosphating etc. and Powder coated with approved colour with hinged and earthed front doors, name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made of 3 mm thick sheet steel, with all connections and inter- connections and having appropriate rating busbars & earth bus. The busbars should be of suitably rated TPN Aluminium having the specified normal and short circuit capacities and should be insulated with heat shrinkable colour coded PVC sleeves and supported by DMC/SMC pillar/finger type busbar supports. The panel shall be manufactured as per the standards and requirements of State Electrical Inspectorate, Supply authority’s and Bureau of Indian standards. (Cable entry according to site conditions). Door shall be properly gasketed to avoid entry of moisture. All components, panels, cables etc. shall conform to relevant IS specifications and shall also be got approved by the EIC. Front door of the switches, cable alley shall be hinged type and earthed properly, All control wires shall be 1.1 kV grade, FRLS 2.5 Sq.mm Copper wire. Panel shall be fabricated only by an agency having both ISO & CPRI certification and shall be approved by the client/ consultant. Design and fabrication of the switch boards should be as per standards of State electrical inspectorate, Power Supply Company and Bureau of Indian standards. The panel drawings should be submitted for approval before the Consultants/ Client's Engineer before manufacturing. (Cable entry according to site conditions). All MCCs Shall be wired and completed in consultation with the Machinery Manufacturer OR their drawings/ layouts and shall be compatible with all the specific requirements and also provision for connecting control cables/ control equipment / control relays [if any] for fulfilling the satisfactory completion/ commissioning of plant and machinery. All MCCBs shall be provided with setting range of 0.8-1.0 - Sets as per Connected load at site/SLD OR as per the Approval from the approving Authority, and shall be provided with rotary front drive, door inter lock and pad lock. ------ SSB-01 AND SSB-02 (CARDING): Busbars: 200A TPN Al. Busbar - 1Set. [Minimum CD: 0.8A / Sq.mm, AL] & Earth bus - 25.4 x 6.3mm CU. Incomer-Grid Supply: 1 Set. 200A TPN Isolator, with rotary front drive, door inter lock and pad lock. Meters and instruments-Incomer Side: 1 No. Digital Combination meter with Voltage and Current values with 3Nos 200/5A, 10VA, Class 0.5, CTs, 2A HRC Control Fuses & fuse units, 1 Sets RYB Indicating lamps LED, with 2A HRC Control Fuses & fuse units. Out Goings: 6 Set and 5 Set 63A 3 Pole with neutral, MCCB, 25KA (Ics)

2

-

-

... More
SSB-03 (DRAWING) Description same as of MV Panels/ Distribution Boards but comprising the following specific components:- Busbars: 200A TPN Al. Busbar - 1Set. [Minimum CD: 0.8A/ sq.mm, AL] & Earth bus - 25.4 x 6.3mm CU. INCOMER - 1 Set. 200A TPN Isolator, with rotary front drive, door inter lock and pad lock. Meters and instruments- Incomer Side: 1 No. Digital Combination meter with Voltage and Current values with 3Nos 200/5A, 10VA, Class 0.5, CTs, 2A HRC Control Fuses & fuse units, 1 Sets RYB Indicating lamps LED, with 2A HRC Control Fuses & fuse units OUTGOINGS - 3 Set. 63A 3 Pole with neutral, MCCB, 25KA (Ics), 3 Set. 50A 3 Pole with neutral, MCCB, 25KA (Ics), 2 Set. 40A 3 Pole with neutral, MCCB, 25KA (Ics), All MCCBs shall be provided with setting range of 0.8-1.0 - Set as per Connected load at site/SLD OR as per the Approval from the approving Authority, and shall be provided with rotary front drive, door inter lock and pad lock.

1

-

-

... More
SSB-04 AND SSB-05 (SIMPLEX): Description same as of MV Panels/ Distribution Boards but comprising the following specific components Busbars:- 200A TPN Al. Busbar - 1Set. [Minimum CD: 0.8A/sq.mm, AL] & Earth bus - 25.4 x 6.3mm CU. INCOMER - 1 Set. 200A TPN Isolator, with rotary front drive, door inter lock and pad lock. Meters and instruments- Incomer Side - 1 No. Digital Combination meter with Voltage and Current values with 3Nos 200/5A, 10VA, Class 0.5, CTs, 2A HRC Control Fuses & fuse units, 1 Sets RYB Indicating lamps LED, with 2A HRC Control Fuses & fuse units. OUT GOINGS - 5 Set and 6 set 50A 3 Pole with neutral, MCCB, 25KA (Ics), All MCCBs shall be provided with setting range of 0.8-1.0 – Sets as per Connected load at site/SLD OR as per the Approval from the approving Authority, and shall be provided with rotary front drive, door inter lock and pad lock.

2

-

-

... More
SSB-06 (COMBER) Description same as item No. 2.0 above but installed separately at control room and comprising the following specific components:- Busbars: 200A TPN Al. Busbar - 1Set. [Minimum CD: 0.8A/sq.mm, AL] & Earth bus - 25.4 x 6.3mm CU. INCOMER: 1 Set. 200A TPN Isolator, with rotary front drive, door inter lock and pad lock. Meters and instruments-Incomer Side 1 No. Digital Combination meter with Voltage and Current values with 3Nos 200/5A, 10VA, Class 0.5, CTs, 2A HRC Control Fuses & fuse units, Etc. complete 1 Sets RYB Indicating lamps LED, with 2A HRC Control Fuses & fuse units. OUTGOINGS: 6 Set. 40A 3 Pole with neutral, MCCB, 25KA (Ics), All MCCBs shall be provided with setting range of 0.8-1.0 - Sets as per Connected load at site/SLD OR as per the Approval from the approving Authority, and shall be provided with rotary front drive, door inter lock and pad lock.

1

-

-

... More
MCC-A AND MCC-B (HUMIDIFICATION PLANT FOR SPG-I&II) Description same as item No. 2.0 above but installed separately at control room and comprising the following specific components: - Busbars: 200A TPN Al. Busbar - 1Set. [Minimum CD: 0.8A/sq.mm, AL] & Earth bus - 25.4 x 6.3mm CU. INCOMER - 1 Set. 200A TPN Isolator, with rotary front drive, door inter lock and pad lock. Meters and instruments-Incomer Side- 1 No. Digital Combination meter with Voltage and Current values with 3Nos 200/5A, 10VA, Class 0.5, CTs, 2A HRC Control Fuses & fuse units, 1 Sets RYB Indicating lamps LED, with 2A HRC Control Fuses & fuse units. OUTGOINGS: 2 Set. 80A 3 Pole with neutral, MCCB, 25KA (Ics), 4 Set. 50A 3 Pole with neutral, MCCB, 25KA (Ics), 2 Set. 25A 3 Pole with neutral, MCCB, 25KA (Ics), 2 Set. 20A 3 Pole with neutral, MCCB, 25KA (Ics), 1 set 18.5 kW- Fully Automatic STAR-DELTA Starter, 3 set 11.2 kW- Fully Automatic STAR-DELTA Starter, 3 set 11.2 kW- Fully Automatic STAR-DELTA Starter, 1 set 4.0 kW- Three Phase DOL Starter, 1 set 0.75 kW- Three Phase DOL Starter, 1 set 0.55 kW- Three Phase DOL Starter. All MCCBs shall be provided with setting range of 0.8-1.0 - Sets as per Connected load at site/SLD OR as per the Approval from the approving Authority, and shall be provided with rotary front drive, door inter lock and pad lock. All Star / Delta OR DOL Starters shall be provided with all necessary accessories, Thermal O/L Relay, Single phasing Preventer, start /stop illuminated Push Buttons, Remote control Etc. complete. The Panel shall also have provision for accommodating the VFD Provided by the M/C Supplier for pump Control with all connections/ terminations/ control wiring etc. complete as required.

2

-

-

... More
MCC-C (EXHAUST PLANT FOR SPG-I,II&III): Description same as item No. 2.0 above but installed separately at control room and comprising the following specific components:- Busbars: 200A TPN Al. Busbar - 1Set. [Minimum CD: 0.8A/ sq.mm, AL] & Earth bus - 25.4 x 6.3mm CU. INCOMER- 1 Set. 200A TPN Isolator, with rotary front drive, door inter lock and pad lock. Meters and instruments-Incomer Side - 1 No. Digital Combination meter with Voltage and Current values with 3Nos 200/5A, 10VA, Class 0.5, CTs, 2A HRC Control Fuses & fuse units, 1 Sets RYB Indicating lamps LED, with 2A HRC Control Fuses & fuse units. OUTGOINGS:- 4 Set. 63A 3 Pole with neutral, MCCB, 25KA (Ics), 4 Set. 32A 3 Pole with neutral, MCCB, 25KA (Ics), 1 Set. 20A 3 Pole with neutral, MCCB, 25KA (Ics), 3 set 15.0 kW- Fully Automatic STAR-DELTA Starter, 3 set 5.5 kW- Fully Automatic STAR-DELTA Starter, 1 set 0.55 kW- Three Phase DOL Starter. All MCCBs shall be provided with setting range of 0.8-1.0 - Sets as per Connected load at site/SLD OR as per the Approval from the approving Authority, and shall be provided with rotary front drive, door inter lock and pad lock. All Star / Delta OR DOL Starters shall be provided with all necessary accessories, Thermal O/L Relay, Single phasing Preventer, start /stop illuminated Push Buttons, Remote control, Etc. complete.

1

-

-

... More
MCC-D (EXHAUST PLANT FOR SPG-IV&V): Description same as item No. 2.0 above but installed separately at control room and comprising the following specific components:- Busbars: 200A TPN Al. Busbar - 1Set. [Minimum CD: 0.8A/sq.mm, AL] & Earth bus - 25.4 x 6.3mm CU. INCOMER- 1 Set. 200A TPN Isolator, with rotary front drive, door inter lock and pad lock. Meters and instruments-Incomer Side - 1 No. Digital Combination meter with Voltage and Current values with 3Nos 200/5A, 10VA, Class 0.5, CTs, 2A HRC Control Fuses & fuse units, Etc. 1 Sets RYB Indicating lamps LED, with 2A HRC Control Fuses & fuse units. OUTGOINGS:- 3 Set. 63A 3 Pole with neutral, MCCB, 25KA (Ics), 3 Set. 32A 3 Pole with neutral, MCCB, 25KA (Ics), 2 Set. 20A 3 Pole with neutral, MCCB, 25KA (Ics), 2 set 15.0 kW- Fully Automatic STAR-DELTA Starter, 2 set 5.5 kW- Fully Automatic STAR-DELTA Starter, 1 set 0.55 kW- Three Phase DOL Starter, All MCCBs shall be provided with setting range of 0.8-1.0 - Sets as per Connected load at site/SLD OR as per the Approval from the approving Authority, and shall be provided with rotary front drive, door inter lock and pad lock. All Star / Delta OR DOL Starters shall be provided with all necessary accessories, Thermal O/L Relay, Single phasing Preventer, start /stop illuminated Push Buttons, Remote control, Etc. complete.

1

-

-

... More
MCC-E (SUPPLY&EXHAUST PLANT FOR PREPARATORY):- Description same as item No. 2.0 above but installed separately at control room and comprising the following specific components:- Busbars: 200A TPN Al. Busbar - 1Set. [Minimum CD: 0.8A/sq.mm, AL] & Earth bus - 25.4 x 6.3mm CU. INCOMER: 1 Set. 200A TPN Isolator, with rotary front drive, door inter lock and pad lock. Meters and instruments-Incomer Side 1 No. Digital Combination meter with Voltage and Current values with 3Nos 200/5A, 10VA, Class 0.5, CTs, 2A HRC Control Fuses & fuse units, 1 Sets RYB Indicating lamps LED, with 2A HRC Control Fuses & fuse units OUTGOINGS: 4 Set. 63A 3 Pole with neutral, MCCB, 25KA (Ics), 2 Set. 50A 3 Pole with neutral, MCCB, 25KA (Ics), 1 Set. 32A 3 Pole with neutral, MCCB, 25KA (Ics), 2 Set. 25A 3 Pole with neutral, MCCB, 25KA (Ics), 1 Set. 20A 3 Pole with neutral, MCCB, 25KA (Ics), 2 set 15.0 kW- Fully Automatic STAR-DELTA Starter, 2 set 5.5 kW- Fully Automatic STAR-DELTA Starter, 1 set 0.55 kW- Three Phase DOL Starter, All MCCBs shall be provided with setting range of 0.8-1.0 - Sets as per Connected load at site/SLD OR as per the Approval from the approving Authority, and shall be provided with rotary front drive, door inter lock and pad lock. All Star / Delta OR DOL Starters shall be provided with all necessary accessories, Thermal O/L Relay, Single phasing Preventer, start /stop illuminated Push Buttons, Remote control. The Panel shall also have provision for accommodating the VFD Provided by the M/C Supplier for pump Control with all connections/ terminations/ control wiring etc. complete as required.

1

-

-

... More
MCC-F (SUPPLY&EXHAUST PLANT FOR POST SPG) Description same as item No. 2.0 above but installed separately at control room and comprising the following specific components:- Busbars: 200A TPN Al. Busbar - 1Set. [Minimum CD: 0.8A/sq.mm, AL] & Earth bus - 25.4 x 6.3mm CU. INCOMER - 1 Set. 200A TPN Isolator, with rotary front drive, door inter lock and pad lock. Meters and instruments-Incomer Side- 1 No. Digital Combination meter with Voltage and Current values with 3Nos 200/5A, 10VA, Class 0.5, CTs, 2A HRC Control Fuses & fuse units, Etc. complete, 1 Sets RYB Indicating lamps LED, with 2A HRC Control Fuses & fuse units OUTGOINGS:- 3 Set. 80A 3 Pole with neutral, MCCB, 25KA (Ics), 2 Set. 50A 3 Pole with neutral, MCCB, 25KA (Ics), 1 Set. 32A 3 Pole with neutral, MCCB, 25KA (Ics), 2 Set. 25A 3 Pole with neutral, MCCB, 25KA (Ics), 2 Set. 20A 3 Pole with neutral, MCCB, 25KA (Ics), 2 set 18.0 kW- Fully Automatic STAR-DELTA Starter, 1 set 11.2 kW- Fully Automatic STAR-DELTA Starter, 1 set 5.5 kW- Fully Automatic STAR- DELTA Starter, 1 set 4.0 kW- Three Phase DOL Starter, 1 set 0.75 kW- Three Phase DOL Starter, 1 set 0.55 kW- Three Phase DOL Starter. All MCCBs shall be provided with setting range of 0.8-1.0 - Sets as per Connected load at site/SLD OR as per the Approval from the approving Authority, and shall be provided with rotary front drive, door inter lock and pad lock. All Star / Delta OR DOL Starters shall be provided with all necessary accessories, Thermal O/L Relay, Single phasing Preventer, start /stop illuminated Push Buttons, Remote control, Etc. complete. The Panel shall also have provision for accommodating the VFD Provided by the M/C Supplier for pump Control with all connections/ terminations/ control wiring etc. complete as required.

1

-

-

... More
REPAIRE AND MAINTENANCE OF LT PANELS Supply of all necessary materials and carrying out repair and maintenance works of the following LT panels [Existing] as shown in the One Line Diagrams. The scope of works only includes cleaning, priming, spray painting with required colour [Grey], replacing of Bus Bar insulators/sleeves [where ever required] / SMC Supports [Pillar Type/ Finger Type], PVC Sleeves [where ever required], etc. and testing and commissioning. All panels boards shall be tested at site [SAT] and ensure all the values are sufficient and satisfactory as per standards and requirements at the point of electrical safety rules as per CEA regulations/ KSEI Guidelines/ Orders and shall be recorded in presence of the Engineer in Charge/ Consultant. ------- MSB [MAIN MV PANEL-DOUBLE BUS PANEL]

1

-

-

... More
PCC-1

1

-

-

... More
PCC-2

1

-

-

... More
PCC-3

1

-

-

... More
PCC-4

1

-

-

... More
PCC-5

1

-

-

... More
PCC-6

1

-

-

... More
PCC-7

1

-

-

... More
PCC-8

1

-

-

... More
PCC-9

1

-

-

... More
PCC-9-A

1

-

-

... More
PCC-10

1

-

-

... More
BUS DUCT 2000A, 4POLE, 415V.

20

-

-

... More
RETROFITTING DAMAGED SWITCHGEARS/ COMPONENTS.: Supply, installation, testing and commissioning of the following switch gears within the existing LT Panel Boards including necessary cutting, drilling, extension of Bus Bars, Interconnections etc. as required as per standards complete. The scope also includes dismantling and stacking of existing damages switches/ bus bars etc. as directed by the Engineer in Charge/ Consultant. ---- 400A TPN Isolators Incomer of PCC-10

2

-

-

... More
RETROFITTING DAMAGED SWITCHGEARS/ COMPONENTS.: Supply, installation, testing and commissioning of the following switch gears within the existing LT Panel Boards including necessary cutting, drilling, extension of Bus Bars, Interconnections etc. as required as per standards complete. The scope also includes dismantling and stacking of existing damages switches/ bus bars etc. as directed by the Engineer in Charge/ Consultant. ---- 630 A TPN Isolators or MCCB Incomer of MSB

2

-

-

... More
315A TPN Switch Fuse Units

1

-

-

... More
250A TPN Switch Fuse Units

4

-

-

... More
100A TPN Switch Fuse Units

6

-

-

... More
63A TPN Switch Fuse Units

4

-

-

... More
Heavy Duty APP Capacitors of Different ratings within the APFC Panel

250

-

-

... More
HRC FUSE LINKS: Supply, installation, testing and commissioning of the following rating HRC Fuse Links DIN Type [Bolted Type for lower rating] suitable for 315A/ 250A/100A/63A SFUs within the existing Panel Boards/ Switchgears. The Fuse links shall be provided as per the Standards and requirements of the Scheme Approval from the Department of Electrical Inspectorate in order to achieve Grading in between sections. The scope also includes dismantling and stacking of existing damages FUSE LINKS as directed by the Engineer in Charge/ Consultant. 400A

3

-

-

... More
300A/315A

30

-

-

... More
250A

3

-

-

... More
200A

6

-

-

... More
160A

36

-

-

... More
150A

36

-

-

... More
125A

33

-

-

... More
120A

21

-

-

... More
100A

9

-

-

... More
80A

72

-

-

... More
63A

3

-

-

... More
50A

3

-

-

... More
40A/35A

6

-

-

... More
25A

3

-

-

... More
2A [Control Fuses]

60

-

-

... More
METERS AND INSTRUMENTS: Supply, installation, testing and commissioning of the following instruments/ Cast Resin CTs/ panel accessories within the existing Panel Boards. The CTs shall be provided as per the Standards and requirements of the Scheme Approval from the Department of Electrical Inspectorate. The scope also includes dismantling and stacking of existing damages CTs/ Components Etc. as directed by the Engineer in Charge/ Consultant. --- RYB/ Trip Indication Lamps LED

48

-

-

... More
Cast Resin CTs 1250/5A, Class 05, 10VA

6

-

-

... More
Cast Resin CTs 400/5A, Class 05, 10VA

39

-

-

... More
Cast Resin CTs 300/5A, Class 05, 10VA

3

-

-

... More
25A HRC Fuse Units [Control Fuses]

60

-

-

... More
Digital Combination Meters V,A,F,PF, kVA, PF & kWhr

2

-

-

... More
Digital Combination Meters V,A & F

14

-

-

... More
Analogue Ammeters [0-1250A]

6

-

-

... More
Analogue Volt meters [0-500V]

2

-

-

... More
Volt Meter Selector Switches

2

-

-

... More
Mechanical Interlocks between Switchgears

10

-

-

... More
LOCAL ISOLATION FOR MOTORS/ EQUIPMENTS:- Supply, Installation, Testing and commissioning of Lockable OFF PBs with in suitable Sheet Steel Powder coated enclosures complete.

20

-

-

... More
Supply, Installation, Testing and commissioning of 32A TP Isolators, MCB Type with in suitable Sheet Steel Powder coated enclosures complete.

12

-

-

... More
Supply, Installation, Testing and commissioning of 63A TP Isolators, MCB Type with in suitable Sheet Steel Powder coated enclosures complete.

4

-

-

... More
POWER FACTOR IMPROVEMENT CAPACITORS: Supply, Installation, Testing and commissioning of the following ratings Heavy Duty, APP Capacitors with in suitable Sheet Steel Powder coated enclosures, and giving connections as direct connection near by Motors/ Equipments, complete. --- 15kVAR

20

-

-

... More
10kVAR

6

-

-

... More
LT CABLES AND CABLING:- Supply, laying, Testing and Commissioning of the following sizes of 650/1100 Volts Power/ Control Cables with Aluminium/ Copper Conductor (Solid up to 10 sqmm and Stranded for balance), XLPE Insulated, Cores Laid Up, Inner Sheathed, Armoured and Extruded PVC Type ST2 Outer Sheathed As Per IS-7098 (Part 1) 2011 with Up To Date Amendments. The cables shall be laid in cable trenches or on wall or through pipes as per specifications, including providing of cable route makers in every 50M and at all strategic turning/ diversion points [if burried Directly in ground], etc. Necessary clamping should be providing while burying cables in prepared trenches etc.as per standards. ALUMINIUM CONDUCTOR POWER CABLE --- 3.5x240 Sq.mm AL Armoured

200

-

-

... More
3.5x185 Sq.mm AL Armoured

150

-

-

... More
3.5x150 Sq.mm AL Armoured

10

-

-

... More
3.5x120 Sq.mm AL Armoured

1000

-

-

... More
3.5x95 Sq.mm AL Armoured

150

-

-

... More
3.5x70 Sq.mm AL Armoured

100

-

-

... More
3.5x50Sq.mm AL Armoured

100

-

-

... More
3.5x35Sq.mm AL Armoured

10

-

-

... More
3.5x25Sq.mm AL Armoured

10

-

-

... More
3.0x25Sq.mm AL Armoured

110

-

-

... More
4.0x16Sq.mm AL Armoured

100

-

-

... More
3.0x16Sq.mm AL Armoured

270

-

-

... More
4.0x10Sq.mm AL Armoured

200

-

-

... More
3.0x10Sq.mm AL Armoured

310

-

-

... More
4.0x6Sq.mm AL Armoured

10

-

-

... More
3.0x6Sq.mm AL Armoured

1200

-

-

... More
4.0x4 Sq.mm AL Armoured

10

-

-

... More
3.0x4Sq.mm AL Armoured

1200

-

-

... More
COPPER CONDUCTOR POWER CABLE --- 4.0x50Sq.mm - Cu Armoured

100

-

-

... More
4.0x25Sq.mm - Cu Armoured

40

-

-

... More
4.0x16Sq.mm - Cu Armoured

400

-

-

... More
4.0x10Sq.mm - Cu Armoured

800

-

-

... More
4.0x4Sq.mm - Cu Armoured

1

-

-

... More
3.0x4Sq.mm - Cu Armoured

35

-

-

... More
4.0x2.5Sq.mm - Cu Armoured

165

-

-

... More
3.0x2.5Sq.mm - Cu Armoured

600

-

-

... More
COPPER CONDUCTOR CONTROL CABLE 16.0x1.5Sq.mm

74

-

-

... More
12.0x1.5Sq.mm - Cu Armoured

246

-

-

... More
10.0x1.5Sq.mm - Cu Armoured

45

-

-

... More
8.0x1.5Sq.mm - Cu Armoured

96

-

-

... More
7.0x1.5Sq.mm - Cu Armoured

32

-

-

... More
6.0x1.5Sq.mm - Cu Armoured

38

-

-

... More
4.0x1.5Sq.mm - Cu Armoured

128

-

-

... More
3.0x1.5Sq.mm - Cu Armoured

1

-

-

... More
2.0x1.5Sq.mm - Cu Armoured

1

-

-

... More
3Cx0.75sQ.mm Copper Shielded Cable

90

-

-

... More
CABLE TERMINATIONS- ALUMINIUM CONDUCTOR POWER CABLE:- Supply and providing end terminations using siemens type compression gland for PVC insulated and PVC sheathed armoured conductor cable 1.1KV grade for the followings sizes including earthing the glands as required as per standards.--- 3.5x240 Sq.mm

4

-

-

... More
3.5x185 Sq.mm

10

-

-

... More
3.5x150 Sq.mm

2

-

-

... More
3.5x120 Sq.mm

50

-

-

... More
3.5x95 Sq.mm

10

-

-

... More
3.5x70 Sq.mm

2

-

-

... More
3.5x50Sq.mm

4

-

-

... More
3.5/3.0x35Sq.mm

2

-

-

... More
3.5x25Sq.mm

2

-

-

... More
3.0x25Sq.mm

8

-

-

... More
4.0x16Sq.mm

2

-

-

... More
3.0x16Sq.mm

16

-

-

... More
4.0x10Sq.mm

1

-

-

... More
3.0x10Sq.mm

8

-

-

... More
4.0x6Sq.mm

1

-

-

... More
3.0x6Sq.mm

12

-

-

... More
3.0 x 4 Sq.mm

40

-

-

... More
CABLE TERMINATIONS- COPPER CONDUCTOR POWER CABLE 4.0/3.5x50 Sq.mm

12

-

-

... More
4.0x25Sq.mm

16

-

-

... More
4.0x16Sq.mm

50

-

-

... More
4.0x10Sq.mm

40

-

-

... More
4.0x4Sq.mm

2

-

-

... More
3.0x4Sq.mm

2

-

-

... More
4.0x2.5Sq.mm

8

-

-

... More
3.0x2.5Sq.mm

6

-

-

... More
CABLE TERMINATIONS- COPPER CONDUCTOR CONTROL CABLE -- 16.0x1.5Sq.mm

4

-

-

... More
12.0x1.5Sq.mm

8

-

-

... More
10.0x1.5Sq.mm

2

-

-

... More
8.0x1.5Sq.mm

4

-

-

... More
7.0x1.5Sq.mm

2

-

-

... More
6.0x1.5Sq.mm

2

-

-

... More
4.0x1.5Sq.mm

8

-

-

... More
3.0x1.5Sq.mm

2

-

-

... More
3.0x1.5Sq.mm

2

-

-

... More
3Cx0.75sQ.mm Copper Shielded Cable

2

-

-

... More
GENERAL EARTHING - BARE COPPER EARTHING CONDUCTORS:- Supply, Laying/ fixing of earthing conductor with Purity not less than 99% of the following sizes/ type, jointing as per IS:3043/87 in trench walls pulling through pipes etc.as required. All joints in the system shall be braced properly with lead. 50x6 mm Copper Strip

1

-

-

... More
40x6 mm Copper Strip

1

-

-

... More
31x6 mm Copper Strip

1

-

-

... More
25x3 mm Copper Strip

270

-

-

... More
Copper wire No.4 SWG

310

-

-

... More
Copper wire No.10 SWG

800

-

-

... More
GENERAL EARTHING - HOT DIP GI EARTHING CONDUCTORS:- Supply, Laying/ fixing of earthing conductor of the following sizes/ type, jointing as per IS:3043/87 in trench walls pulling through pipes etc.as required. All joints in the system shall be welded properly and epoxy painted after priming. 50x6 mm HD GI Strip

560

-

-

... More
40x6 mm HD GI Strip

470

-

-

... More
31x6 mm HD GI Strip

360

-

-

... More
25x6 mm HD GI Strip

320

-

-

... More
MAINTENANCE OF EARTHING STATIONS: Supply of all necessary materials and carrying out repair works of the existing stations including replacing of damaged bolts/ nuts/ washers/ bracing the ends, etc. and taking earth reading in presence of the EIC/ Consultant to obtain a satisfactory value for each station, etc. complete.

10

-

-

... More
MISCELLANEOUS ITEMS:- Supply and Fixing of FRAMED KEY ONE LINE DIAGRAM in A-1 Size with frame work and glass at desired locations including supply of all fixing materials as required and as directed by EIC/ Consultant.

2

-

-

... More
Supply and fixing of standard Shock Treatment Chart with frame work and glass including supply of all fixing materials as required and as directed by EIC/ Consultant

4

-

-

... More
CABLE TRAYS/ SUPPORTS: Supply and Erection of Vertical/Horizontal type M.S. Cable Trays and cable supports fabricated out of M.S Angles (ISA) and M.S. flats with sufficient width and spacing between successive cross members and supported at adequate spacing. The cable trays and supports 'shall be painted with 2coats of Zinc chromate 'primer and 2coats of enamel paint. 25x25x6mm MS angles and 20x6mm MS flats shall be used for trays up to 450mm wide and 40x40x6mm MS angles and 20x6mm MS flats shall be used for trays up to 900mm wide.

1200

-

-

... More
CIVIL WORKS: Excavation of soil in all classes up to a depth of 750mm suitable for Cable Trench directly burying and backfilling with excavated soil after laying of cable including supply and laying of bricks, sand cushioning, etc. as required as per the standards for cable laying.

12

-

-

... More
CT&PT METER TESTING: Transporting CT/PT units and TOD meter (11KV) to the testing laboratories of KSEB and obtaining the necessary certificates for approval and load sanction from power supply company.

1

-

-

... More
TRANSFORMER PROTECTION CUM MAINTENANCE:- 'Supply and Providing protection Class, Cast Resin, CTs suitable for REF Protection Relay [4 CT Method], Class PS, 10VA with suitable ID and outer dimensions.

8

-

-

... More
Supply and Providing protection Class, Cast Resin, CTs suitable for Low set E/F Protection Relay. The NCT provided in the Earthing conductor shall be provided with necessary control box and supports.

2

-

-

... More
Supply and providing Buchholz Relay, Oil Temperature and Winding Temperature [high] Indicators [OTI&WTI], with marshalling box and provision for alarm trip at Primary Breaker.

2

-

-

... More
Supply of all necessary materials, labour etc. and carrying out Over all maintenance for the Existing 800 kVA ONAN OCTC Transformer, replacement of full set Gasket, Breather, Cleaning, Priming and Painting with approved colour Epoxy Paint, etc. complete. Test certificates/reports shall also be issued after conducting all necessary routine tests, through competent and approved agency.

2

-

-

... More
Supply and Filling of Brand New Transformer Oil as per IS 335 of sufficient quantity for 800kVA ONAN Transformer, [740 Litre] tested for BDV including draining out the old oil, cleaning and washing the tank etc. complete.

2

-

-

... More
Supply and providing new Radiators (4nos) with dimensions of (1100mm x 520mm x 10 fins.). Butterfly valve (8nos) along with fasteners and all necessary accessories, pipes etc. This scope includes all necessary fabrication, assembling and including replacing the existing tank, complete.

2

-

-

... More
RENOWATION OF 4 POLE STRUCTURE: Supply off all materials necessary for refurbishing of Four pole structure including patch works for rusted RS Joists, MS channels, Angles, cutting, welding, aluminium painting etc. including supply and installation of following overhead line accessories :- 2 Sets- of 11KV, 400A, 3 phase gang operated , vertical single make/break type off load Air break switches with operating rods, handle locking arrangements, 2 sets -DO fuses, 2 sets- 9kV, 5kA, Lightning arrestors, 11KV pin insulators, 11KV Disc insulators & complete with all hardware, re-conditioning of SWG '0' Copper Jumpering, 25x3mm Cu Earthing the structure, bolts, nuts, etc., 6 SWG Copper for Lightning arrestor earthing including repairing and painting of all round fencing to a height of 1.8 meter with all-round clearance of 1.25 meter and filling of 40mm granite jelly in the yard all as per standard requirements of Electrical inspectorate.

1

-

-

... More
DOCUMENTS & APPROVAL- ELECTRICAL INSPECTORATE APPROVALS & SANCTION ORDERS: Preparation of all documents, applications, forms and conducting Soil resistivity tests, submission of Scheme, obtaining Scheme Approval, Conducting Electrical Inspection, as installed drawings, obtaining Energisation Sanction Orders for the Entire Installation including installations/ equipment/ panels/ loads, etc. existing at the premises but to be regularised as per statutes, etc. complete. (Excluding statutory charges).

1

-

-

... More
SUPPLY AUTHORITY CONNECTED LOAD/ CD REGULARISATION: 'Preparation of necessary documents, forms, drawings, schemes, certificates, submitting completion reports, Executing HT Supply Agreement, etc. and obtaining Power sanction/ additional Power Sanction service connection @ 11kV from KSEB for the installation. All statutory charges shall be remitted by the clients.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.