Travancore Devaswom Board Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Travancore Devaswom Board Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date9 Aug 2024
Closing Date12 Aug 2024
Tender Amount₹ 3,94,820 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 9,720Document Cost
₹ 917Tender Fee
Refer Documents
Summary
Electrification Of The Newly Constructed Dialysis Center At Old Danalekshmi Bank Nanthancode.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_TDB_684955_1Bid Award Id
ViewTender No
TDB/EEE/ET-58/2024-25Tender Authority
Travancore Devaswom Board ViewPurchaser Address
-Website
http://http://travancoredevaswomboard.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Single Control light point with 6A, plate ceiling rose - Short point
30
-
-
Single control light point without ceiling rose - Short point
10
-
-
Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
20
-
-
Independent plug - Short point
12
-
-
Supplying and fixing suitable size GI box with modular plate and cover in FRLS on to surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
10
-
-
Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required:1200 mm 1X20W LED Lamp with box type fixture
10
-
-
Supplying and fixing of Angle/straight batten holder with box, 200 mm PVC shade 12 W LED bulb fixing on and giving connection.
10
-
-
Supply and fixing 24W LED Square Panel Light (Havells/Equivalent) with all accessories including connections etc as required
20
-
-
Supply , installation, testing and commissioning of 400 mm wall mounting fan 5 leaf policab/Equivalent make complete with all accessories including connections etc as required
6
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required:25 mm
20
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required : 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
20
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required: 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
80
-
-
Earthing with GI earth pipe 2.5meter long 40mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe, etc. with charcoal/coke and salt, as required.
2
-
-
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required :3.15 mm copper conductor ( 10 SWG)
30
-
-
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (butwithout MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) : 4 way (4 + 12), Double door
1
-
-
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.:63 amps
1
-
-
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
1
-
-
Supply and fixing 5Amps to 32 Amps rating 240/415V, ‘C’ curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning, etc. as required. Single pole
12
-
-
4 way (8 + 12) double cover TPN vertical DB with provision for fixing
MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
1
-
-
16 A-100A, 16 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
1
-
-
APPENDIX B: Installation of 2.0 Ton split Air Conditioner to the newly constructed dialysis center at Old Dhanlaxmi bank, Nanthencode
-
-
-
Supply, installation, testing and commissioning of Split Air-Conditioner and allied accessories with following configuration
-
-
-
Daikin/Blue star/voltas/carrier - 1.8 Ton 5 Star inverter
Air Conditioners R32 refrigerant 100% Copper
2
-
-
5 kv Stabilizer working Voltage Range (175V -275V)
2
-
-
Outdoor Unit Stand with anti powder coated type Capacity – 1.0 TR to 2.0 TR
2
-
-
Supply and fixing of 25mm PVC Drain Pipe along with requires accessories
10
-
-
Supply and providing 10mm thick size soft drawn Copper Pipe
6
-
-
Supply and fixing of power cable
10
-
-
Unit Installation Charge
2
-
-
Evaluation Notes How It Works ?