The Pharmaceutical Corporation IM Kerala Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

The Pharmaceutical Corporation IM Kerala Limited - OUSHADHI Tender

Works
Eprocure
Opening Date24 Aug 2020
Closing Date4 Dec 2020
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying, Installation, Testing and Commissioning of electric driven pressurisation pump ( Jockey Pump )suitable for automatic operation and consisting of following, complete in all respect as required as per technical specification (a)Vertical in-line type pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal and flow of 180 lpm at 100 m. head conforming to IS 1520.(b) Suitable HP Sqiurrel cage induction motor, TEFC, synchronous speed 2900 RPM, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required along with flexible connections(expansion bellows) at suction and discharge ends.(d) Suitable cement concrete foundation duly plastered with anti vibration pads .

2

-

-

... More
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation, rated capacity of 900 lpm at 40 m approximate head and consisting of following, complete in all respects, as required and as oper the technical specifications: Monoblock Pump(Terrace Pump) of C.I body, bronze impeller,SS shaft with mechanical seal, volute type with suitable HP SQ cage induction motor, suitable for operation on 415V, 3phase 50Hz, AC with IP 55 class of protection for enclosure, horizontal foot mounted type with class F insulation.(c) M.S.fabricated common base plate, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. The rate must include the cost of suitable starter and 1 no. MCB isolator (starter control panel on the ground floor with push buttons for manual start & stop of the pump) and necessary wires/cables (power and control wirings along with earthing accessories & wires) and terminations for successful and automatic operation of pump; complete as required as per the technical specifications.

1

-

-

... More
Supply, installation, testing and commissioning of pressure gauge 0-200 PSI (0 - 16 Kg/sq.cm) range, 3/8" BSP bottom entry, 150 mm dial weather proof with stainless steel internals including fittings, ball valves etc. complete as required as per technical specification.

77

-

-

... More
Supply, installation, testing and commissioning of industrial type DIFFERENTIAL pressure switch having 1/4" BSP(F) connection IP:32 enclosure protection, phosphor bronze bellows as sensing element, SPDT contact system, switch rating 6A Inductive/10A resistive 380 V AC, 0.2A Inductive/10A resistive 250V DC suit with ball valve etc. complete as required as per technical specification.

6

-

-

... More
Supply, installation, testing and commissioning of air vessel made of 250 mm dia 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Gun metal wheel valve, with required accessories,and painting with synthetic enamel paint of approved shade as required as per technical specification.

1

-

-

... More
Supply, laying, testing & commissioning of 'C' class heavy duty GI pipe conforming to IS 1239/IS 3589 including jointing, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc., fixing the pipe on the wall/ceiling of existing buiings with suitable supports and painting with one coat of primer and two or more coats of synthetic enamel paint of required shade, making good the walls&ceilings &other structures etc complete as required as per technical specification.

-

-

-

... More
250 mm dia (6,3 mm thickness)

30

-

-

... More
200 mm dia (6.3 mm thickness)

12

-

-

... More
150 mm dia

516

-

-

... More
100 mm dia

1146

-

-

... More
80 mm dia

402

-

-

... More
65 mm dia

318

-

-

... More
50 mm dia

480

-

-

... More
40 mm dia

1140

-

-

... More
32 mm dia

150

-

-

... More
25 mm dia

2064

-

-

... More
Supply, laying, testing & commissioning of 'C' class heavy duty GI pipe conforming to IS 1239 including jointing, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. in ground at a depth of 1m, after excavation & providing cement concrete blocks as supports, applying one coat of bituminous primer and then providing anticorrosive wrapping coating of 4 mm thick as per IS 10221, refilling the trench etc. of following sizes complete as required as per technical specification.

-

-

-

... More
150 mm dia

1998

-

-

... More
100 mm dia

30

-

-

... More
80 mm dia

12

-

-

... More
Supply, installation, testing and commissioning of dual plate non-return valve of following sizes having PN 16 rating complete with CI body, ductile iron/steel disc, rubber gasket, GI bolts, nuts, washers etc. as required as per technical specification and conforming to API 594.

-

-

-

... More
250 mm dia

1

-

-

... More
150 mm dia

3

-

-

... More
100 mm dia

1

-

-

... More
65 mm dia

2

-

-

... More
Supplying, fixing, testing & commissioning of double flanged cast iron sluice valve as per IS 14846 of rating PN 1.6 with non rising spindle, bronze/gun metal seat, Stainless Steel spindle, Gland packing, Rubber gasket,ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 14846 of following sizes as required as per technical specification.

-

-

-

... More
250 mm dia

2

-

-

... More
200 mm dia

3

-

-

... More
150 mm dia

7

-

-

... More
80 mm dia

2

-

-

... More
Supply, installation, testing and commissioning of butterfly valve of following sizes having PN 16 rating, CI body, Ductile iron/SS disc,Nitrile rubber/EPDM liner complete with GI nuts, bolts, washers, gaskets conforming to relevant standards (IS 13095/API 609), complete as required as per technical specification.

-

-

-

... More
150 mm dia

47

-

-

... More
100 mm dia

35

-

-

... More
80 mm dia

32

-

-

... More
65 mm dia

16

-

-

... More
Supply, installation, testing and commissioning of forged brass ball valve of 40 mm dia complete with all accessories and conforming to relevant standards and as required as per technical specification.

28

-

-

... More
Supply,installation,testing and commissioning of gun metal fire hydrant valve ,single head oblique type with 63 mm instantaneous outlets with female socket for hose connection and inlet side with flange suitable for 80 mm pipe flange,valve conforming to IS:5290 complete with blank cap,chain etc as per technical specification. The rate shall also include the cost of orifice plate and its accessories wherever necessary as detailed in the technical specification.

49

-

-

... More
Supply, installation, testing and commissioning of First-aid Hose Reel with MS construction spray painted in Post office Red, conforming to IS 884 with up to date amendments, complete with the following as requiredas per technical specification. (a) 30 m. long 20 mm (nominal internal dia water hose Thermoplastic (Textile reinforced) Type-2 as per IS: 12585 (b) 20 mm (nominal internal ) dia gun metal globe valve & nozzle. (c) Drum and brackets for fixing the equipments on wall. (d) Connections from riser with suitable dia stop valve (gun metal) & M.S. Pipe & socket.

39

-

-

... More
Supply, installation, testing and commissioning of 63 mm dia, 15 mtr. Long RRL hose pipe with 63 mm dia Male and Female Gun metal couplings duly binded with GI wire, rivets etc. conforming to IS 636 (type-A) as required as per technical specification.

98

-

-

... More
Supply, installation, testing and commissioning of 63 mm dia Gun metal branch pipe with 20 mm (nominal internal diameter) size Gun Metal nozzle conforming to IS 903, suitable for instantaneous connection to inter-connect hose pipe coupling as required as per technical specification.

49

-

-

... More
Supply, installation, testing and commissioning of hose boxes wall/pedestal type of size 900/750 x 250 x 600 mm made out of 16 SWG MS sheet steel with front side glass, locking arrangement and painted with approved colour completed as required and as per specifications. The mounting arrangement as per the technical specifications and drawings shall be provided.

49

-

-

... More
Supply, installation, testing and commissioning of Fire brigade collective breaching with 4 nos. of 150 mm flanged out let connection and built in check valves complete as required as per technical specification.

7

-

-

... More
Supply, installation, testing and commissioning of fire brigade suction hose coupling (Two way draw out connection) in CI Body, gun metal internal connection with nut for female coupling as per IS‐904 complete with suction pipe and foot valve (to be connected to static tank) complete as required and as specified in the technical specification.

1

-

-

... More
Supply, installation, testing and commissioning of Air release valve, 25 mm dia, complete as required as pet the technical specification

33

-

-

... More
Providing, Installation, testing and commissioning of Y strainer with CI body, 3 mm perforated SS screen, flanged end connection, of following size confirming to IS specifications complete with gaskets, seal and accssesories as required as per the technical specification.

-

-

-

... More
200 mm dia

3

-

-

... More
100 mm dia

1

-

-

... More
80 mm dia

2

-

-

... More
Providing, fixing, testing & commissioning of UL listed sprinklers of the following type :

-

-

-

... More
Standard response, standard coverage sprinkler, pendant type sprinkler ;1/2" NPT, K -5.6, Chrome Finish; operating temperature at 68 deg. C. with rosette plate, complete as required as per the technical specification.

222

-

-

... More
Standard response, standard coverage sprinkler, upright type sprinkler ;1/2" NPT, K -5.6, Chrome Finish; operating temperature at 68 deg. C. complete as required as per the technical specification.

705

-

-

... More
Quick response, extended coverage sprinkler ;3/4" NPT, K-11.2, Chrome Finish; operating temperature at 68 deg.C, complete as required with all accessories as per the technical specification.

356

-

-

... More
Supply, installation, testing and commissioning of UL listed flow switch with SPDT contacts, with fixing accessories suitable for nominal pipe dia meters ranging from 1" to 6". The body of the flow switch shall be water proof with IP55 class protection. There shall be inbuilt settings to adjust the flow rate and alarm retard time. The flow switch should have minimum withstand pressure of 15Kg/cm2 and operating pressure ranging from 3.5kg/cm2 to 10Kg/cm2. complete as required as per the technical specification.

24

-

-

... More
Supply, installation, testing and commissioning of 1m unbraided flexible connection to position the sprinkler head in desired location in suspended ceilings. The unit must be complete with stainless steel flexible connection with nipple, reducer, square bar and brackets etc as required as per technical specification. The flexible connector shall be UL Listed complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar complete as required as per technical specification.

143

-

-

... More
Supply, Installation, testing and commissioning of Electromagnetic Flow meter (Digital type) on Test lines, pump discharge, discharge headers & farthest hydrant points to measure 150 % of pump flow, flow at farthest points etc and suitable to 80-200mm dia. pipe (flow range 47-6840 lpm) complete as required as per technical specification.

7

-

-

... More
Supply, Installation, Testing and Commissioning of 150mm dia Sprinkler alarm valve of Cast iron body and bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the Wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, GI pipe of required size, flanges, orifice plate, gasket etc. complete as required as per the technical specification.

13

-

-

... More
Providing and laying of 450mm dia Non Pressure NP-3 class (Medium duty) R.C.C. pipes (for laying of underground fire pipes at road crossings) including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete as directed by engineer in charge and as required as per the technical specification.

180

-

-

... More
Supply, Installation, Testing and Commissioning of gunmetal foam cum water monitors as per technical specification and conforming to IS: 8442-1996. Monitor shall be BIS approved, made out of IS:1239 seamless steel tubes, hot dip galvanised, 75mm N.B. flanged inlet having ANSI B 16.5 drilling welded to 63mm reducer, IS:318 LTB2 gunmetal ball bearing swivel joints with brass locking arrangement, permitting of 360 degrees horizontal, 80 to -45 degrees vertical traverse, 32mm bore aluminium/copper alloy nozzle with male threaded inlet suitable for a discharge of 1750 l.p.m. at 7kg/cm2 pressure, 53m horizontal throw at 30 deg. angle in still air, bearing IS:8442 mark complete with flanges, gasket,nuts, bolts, etc. as required. Monitors shall be painted with red enamel paint and fixed to suitable location as per instructions. 3% AFFF foam tank/can of 20 L along with necessary accessories for connection to the monitor for successful operation of the monitor shall also be provided.

2

-

-

... More
PORTABLE FIRE EXTINGUISHERS Supply and installation of ABC Stored pressure type Fire Extinguisher 6 Kgs Capacity Mono Ammonium Phosphate based Dry Chemical Powder as per IS 14609 with ISI Mark for Fighting ABC Class of Fire, stored Pressure type of Mild steel body pressurized by Nitrogen Gas. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket. The Extinguisher should be manufactured strictly as per IS: 15683:2018 with ISI mark.

104

-

-

... More
Supply and installation of Carbon-dioxide extinguisher of ISI marked (IS: 15683:2018) 4.5 Kg capacity made of high pressure seamless steel cylinder (CCE marked ) complete with wheel type valve with one meter long braided high pressure discharge hose complete in all respects including initial fill with CO2 gas. complete as required as per the technical specification.

14

-

-

... More
Supply and installation of ISI marked (IS: 15683:2018) Clean agent type fire extinguisher of 2kg capacity. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket, all the accessories and as per the technical specifications.

21

-

-

... More
Supply and installation of ISI marked (IS: 15683:2018) Mechanical foam fire extinguisher of 6L capacity. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket, all the accessories and as per the technical specifications.

5

-

-

... More
Providing and fixing initially fully charged Portable Fire Extinguisher of 25 Kg capacity, trolley mounted, ABC type complete with all accessories and conforming to relevant Indian standards (IS:16018) as required as per the technical specifications.

2

-

-

... More
Supply and installation of Modular (Ceiling mounted) ABC type extinguisher of 5Kg complete as required as per technical specification.

8

-

-

... More
Supply, installation, testing and commissioning of Addressable type Multi Detector (smoke and heat sensor) complete with all accessories like base, base box, etc. to be installed under/above false ceiling, roof and concealed space, interconnecting to loop cable, complete as required as per technical specification. The product shall be UL listed & FM Approved.

672

-

-

... More
Supply, installation, testing and commissioning of addressable type heat detector complete with all accessories like base, base box, etc. to be installed under/above false ceiling, roof and concealed space, etc. interconnecting to loop cable complete as required as per technical specification. The product shall be UL listed & FM Approved.

39

-

-

... More
Supplying, installation, testing & commissioning of addressable(or conventional with suitable modules for addressable detection) beam detector with short circuit isolator (inbuilt or seperate) complete with emitter and receiver including connections with remote test features, all necessary modules etc complete as required in all respect as per technical specification. The product shall be UL listed & FM Approved.

3

-

-

... More
Supply, installation, testing and commissioning of Addressable type Manual Call Point-Re-setable type via special key (non-breaking glass type) complete with push button enclosed in box with provision for cable or conduit coupling as required as per technical specification. The product shall be UL listed&FM Approved.

62

-

-

... More
Supply, installation, testing and commissioning of wall sounder cum strobe complete for both audio and visual indication with all fixing accessories, etc. under false ceiling, roof, wall, etc, interconnecting loop cable etc. and complete as required with necessary modules for successful operation and as per the technical specification. The product shall be UL listed&FM Approved.

57

-

-

... More
Supply, installation, testing and commissioning of 24v Power supply unit for hooters with battery backup. The status of the power supply unit must be monitored from the FACP with necessary modules and alarm shall be obtained if the power supply unit fails to operate, complete in all respect and as required as per technical specification.

23

-

-

... More
Supply, installation, testing and commissioning of fault isolator module to protect one area or a number of devices with complete set to be installed under/above false ceiling, roof, concealed space, wall, etc. interconnecting to loop cable complete as required as per technical specification. The product shall be UL listed&FM Approved.

66

-

-

... More
Supply, installation, testing and commissioning of LED Response indicator for all detectors located above false ceiling, with low profile, white case and shall not exceed 2.5 inches of extension below the finish ceiling, etc and complete as required as per the technical specification.

250

-

-

... More
Supply, installation, testing and commissioning of wall mounted talk back unit with speaker for 2 way communication of fire fighters including all necessary accessories complete as required as per the technical specification.

6

-

-

... More
Supply, installation, testing and commissioning of wall/ceiling mounted 6W speaker including all necessary accessories complete as required as per the technical specification.

9

-

-

... More
Supply, installation, testing and commissioning of micro controller based public address and talk back system consisting of 6 zone (expandable) public address cum talkback console with mike and selector.Multiple channel talk back master control panel shall be with LCD display,power supply, battery charger, battery housing, suitable watt PA & mic, multiple channel (zone) selector switch/facility with all call and mic on. It shall have the facility to connect the music player & USB to provide recorded messages to particular zones. It shall act as a master control station for talkback system to be used for 2-way communication with fire fighters. It shall have zone indication facility, meters to measure supply voltage, DC voltage, battery current. The console shall be provided with suitable capacity amplifier (as per system requirement), suitable capacity battery (min 12V), all assembled in a rugged cabinet (preferably made of 16 SWG MS sheet) and meeting the technical specifications. The rate shall include the cost of all the necessary accessories as required for the successful operation of the system.It shall have provision to integrate with the Fire alarm control panel for Voice evacuation.

1

-

-

... More
Supply of UL listed & FM approved microprocessor based 2 looped, intelligent addressable main fire alarm panel, central processing unit with the loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 150 detectors per loop, network communication card, character graphics/ LCD display with touch screen or other keypad and events history log in the non-volatile memory (EPROM), power supply unit (230 ± 5% V, 50 Hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall be networkable in peer-to-peer basis with other Addressable Fire Alarm Panels. The Panel shall be able to give pin point location of all Fire/Fault conditions of addressable units via the address codes for each unit. The Panel shall also be able to automatically switch off all Control Switches whenever any Alarm is triggered. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (PA- talkback System) and shall be complete with all accessories as per the technical specification. The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as required as per the technical specification and shall have following facilities. a) Programming software for the system b) Automatic system test activates c) Detector sensitivity adjustments d) Alarm verification e) Alpha/numerical display f) Provision to connect to PCs and external printers

2

-

-

... More
Supply of UL listed &FM approved microprocessor based Single looped, intelligent addressable main fire alarm panel, central processing unit with the loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 150 detectors per loop, network communication card, character graphics/ LCD display with touch screen or other keypad and events history log in the non-volatile memory (EPROM), power supply unit (230 ± 5% V, 50 Hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall be networkable in peer-to-peer basis with other Addressable Fire Alarm Panels. The Panel shall be able to give pin point location of all Fire/Fault conditions of addressable units via the address codes for each unit. The Panel shall also be able to automatically switch off all Control Switches whenever any Alarm is triggered. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (PA- talkback System) and shall be complete with all accessories as per the technical specification. The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as required as per the technical specification and shall have following facilities. a) Programming software for the system b) Automatic system test activates c) Detector sensitivity adjustments d) Alarm verification e) Alpha/numerical display f) Provision to connect to PCs and external printers

4

-

-

... More
Supply, installation, testing and commissioning of intelligent addressable Input module for monitoring purpose and send the signal from a flow switch to the alarm panel for initiating alarm when flow occur, as per the technical specification.

27

-

-

... More
Supply, installation, testing and commissioning of addressable control to automatically trigger on/off devices like jet fans, AHU, extract air fans etc in case of fire. The product must meet technical specification.

33

-

-

... More
Supply, installation, testing and commissioning of Repeater Panel for Fire Alarm System with piezo sounder, LCD alpha numeric character display with accept / reset buttons for alarm address of any sensor / field device. The Repeater Panel shall only provide field device address with room number. Analogue Output is not required. The Panel shall be connected to the Fire Alarm Panel. The repeater panel shall be provided with 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The product shall be UL listed&FM Approved.

2

-

-

... More
Supply and laying of 2x 1.5sq.mm armoured Copper FRLS cable ISI marked with proper clamping, supports and terminations appropriately above/below ground or on surface/in recess as required as per the technical specification.

16760

-

-

... More
Supply and laying of 25mm dia PVC conduit along with accessories like PVC bends,couplers,junction box,fastners, iron staples/saddles/screws,in surface/ recess including cutting the wall/ceiling and making good the same in case of recessed conduit etc. and complete as required as per the technical specification.

297

-

-

... More
Supply, installation, testing & commissioning of CO2/Clean agent based linear heat detection trace tube panel/modular flooding system for the MV main distribution electrical panel in the site consisting of gas cylinders with weight calculated on the basis of volume of single largest compartment within the panel. UL listed trace tube of required design length, a cylinder of required capacity, also consisting of master control unit with digital display, load cell, discharge hooter/flashers, pressure gauges, pressure switches for low pressure/discharge indications & interlocks with fire alarm system of the premises & all accessories of complete functionality of system, complete as required as per the technical specification. Bidder shall visit the site and ascertain the panel size.

1

-

-

... More
EMERGENCY SIGNAGE Supply and installation of photoluminescent glow signage such as Fire Duct/Fire Lift/Staircase /Hosereel/No smoking signage etc. of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

64

-

-

... More
Supply and installation of photoluminescent glow signage for "FIRE ASSEMBLY POINT" of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

23

-

-

... More
Supply and installation of photoluminescent glow signage containing standard instructions to the occupants in case of Fire emergency (FIRE ORDER), of standard size (600*800 MM minimum) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

35

-

-

... More
Supply and installation of photoluminescent glow signage such as Emergency Exit/Fire Exit signage etc. of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

83

-

-

... More
Supply and fixing (in appropriate location) of Fire Emergency Evacuation Plan (Color) Printed in Photo Paper of Size A2 sandwitched in Clear acrylic sheets fixed using SS Studs and other accessories complete as required as per the technical specification and conforming to IS 9457, IS12349, IS12407. Evacuation Plan shall be prepared by the contractor.

52

-

-

... More
EXISTING SYSTEM-REVAMPING Servicing, repairing, maintenance, testing and commissioning of existing Butterfly Valves, Air Release Valves, Non Return Valves, existing Foot Valves for Pumps including changing of gasket etc complete in all respects as per the site conditions and as per the technical specifications. (Bidder shall visit the site and inspect the existing system to ascertain the quantum of work).

1

-

-

... More
Servicing, repairing, maintenance, testing and commissioning of existing Hydrant Valve including changing of packing/lining if required,existing Hose Box including changing of broken glass, beeding etc & painting if required, existing Hose Reel including cleaning and greasing etc complete in all respects as per the site conditions and as per the technical specifications. (Bidder shall visit the site and inspect the existing system to ascertain the quantum of work).

25

-

-

... More
Painting of existing above ground pipe, sprinkler & hydrant pipe of internal dia upto 150mm with primer and red paint of required shade as per IS 5 and Pressure testing of existing Fire Protection system & repairing & making good the system including testing and commissioning of entire fire fighting system including the pumps and control panel etc complete in all respects as per the site conditions and as per the technical specifications.(Bidder shall visit the site and inspect the existing system to ascertain the quantum of work).

1

-

-

... More
Servicing, repairing, maintenance, testing and commissioning of existing fire alarm and detection System including changing of defective detectors, wiring, clamps, supports and panel etc complete in all respects as per the site conditions and as per the technical specifications. (Bidder shall visit the site and inspect the existing system to ascertain the quantum of work).

1

-

-

... More
WATER SUPPLY & PLUMBING Supplying, fixing, testing and commissioning of Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 62.5 mm nominal dia

150

-

-

... More
Providing and fixing gun metal gate valve with C.I. Wheel of approved quality (screwed end) including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer- in-Charge at all levels 65 mm nomonal bore

2

-

-

... More
Supplying and fixing of Centrifugal Monobloc drainage pump, with CI construction, CI impeller complete with motor, base plate, foundation bolts, nuts, pressure guage and all accessories. and working with 415V, 3ph and 50 Hz frequency complete as required as per direction of Engineer in Charge. Head- 12 m Discharge-24 m3/hr

1

-

-

... More
Supplying and fixing GM foot valve with all accessories including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels.

-

-

-

... More
40 mm dia

1

-

-

... More
50 mm dia

1

-

-

... More
Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer-in-Charge.

-

-

-

... More
100 mm

4

-

-

... More
150 mm

4

-

-

... More
200 mm

1

-

-

... More
250 mm

2

-

-

... More
Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer-in-Charge.

-

-

-

... More
65 mm

1

-

-

... More
80 mm

1

-

-

... More
100 mm

2

-

-

... More
150 mm

2

-

-

... More
200 mm

1

-

-

... More
250 mm

1

-

-

... More
Main Fire Pump Panel Supply, Installation, Testing and Commissioning of LT Switch board cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised formb construction, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with bus bars extendable on both sides, including all the necessary internal wiring, suitable spreader etc. The panel shall be fabricated from a firm having CPRI certification with test certificates (required for short circuit rating, temperature rise test and IP 42classification) with following switchgears, metering instruments and accessories etc. complete in all respect as per drawing and technical specification. The panel shall be with top/bottom entry to receive incoming & outgoing cable, all necessary interconnection & accessories as per particular specification & single line diagram. The panel shall be Top Entry/Exit and suitable for termination of cable system as per SLD and technical specification Incomer 400 A FP MCCB Isolator-1nos Busbar 400A TPN AL Busbar Instruments:4A, C curve SP MCB, Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, Protection Relays ,Surge protection device Type 1+2 as per SLD . Outgoing 250 A TP MCCB ISO- 1 Nos 320 A TP MCCB ISO- 1 Nos 32 A TP MCCB ISO - 2 Nos, 25 A DP MCB- 3 Nos VFD Starter for 90 kW motor with ON/OFF push button and indicators with Auxiliary and power contactors-1 nos. Fully Automatic Star-Delta starter suitable for 7.5 kW motor with ON/OFF push button with and indicators with Auxiliary and power contactors-2 nos. Space provision for fixing 3 phase VFD with on/off push button, auxillary & power contactors & ON/OFF indication lamps,capacitors in spare outlets suitable for 90 kW motor - 1no. Space provision for fixing 3 phase star-delta starter with on/off push button, auxillary & power contactors & ON/OFF indication lamps,capacitors in spare outlets suitable for 15 kW motor - 2no. Diesel Engine Control - 2No. , Each Diesel engine control consisting of: 25A DP C curve control MCB, 25A On/off control switch - 2 No. , Auto / manual selector switch, 3 attempt starting device, push button etc., All required timers, relays, fuses and accessories for automatic operation of diesel engine. Indication lamp for high water temperature, engine fail to start, engine On indication, high/low lube oil pressure. Necessary control wiring for start / stop solenoid, line / oil pressure switch, temperature switch, pressure switch to fire pump panel, diesel engine control panel to fire pump panel etc. Battery Charger suitable for 12 V / 24 V DC with boost and trickle selector switch, 0 -15 V / 0 - 30 V DC volt meter, 0 - 20 A DC Ammeter - 2 No. 6 panel annunciation window for fault indication with hooter, accept & reset push button, separate hooter for Diesel /electrical pump on running condition - 1 No The system shall include all accessories to control the operation of main electric pump, diesel pump, jockey pump as per the operating sequence for the fire fighting system indicated in the technical specification . The battery charger and all its components should be housed inside the main fire pump panel. The panel shall be painted with approved colour.

1

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. (Note:The total distance from the switch box to the point will not exceed 5mtr, incase if length increases above 5 metres, the wiring shall be measured under item 1.04.01 GROUP C

13

-

-

... More
Wiring for group controlled (looped) light point/fan point/ exhaust fan point/ call bell point(without independent switch etc.) with 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc as required.(Note:The total distance from one point to another the point will not exceed 3 mtr, incase if length increases above 3metres, the wiring shall be measured under item 1.04.01)- Group B

9

-

-

... More
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

150

-

-

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

120

-

-

... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire

60

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
20 mm

30

-

-

... More
25 mm

45

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

3

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

4

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
12 way Double door

1

-

-

... More
Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required. 2 pole 25 amps. (230 Volts),30mA sensitivity.

1

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 6A to 32A, SP, C-CURVE

8

-

-

... More
Supply installation, testing and commissioning of Full automatic star delta starter for 20 HP, 3ph motor including auxiliary contactors, illuminated pushbuttons, provision for connecting external pressure switch, and remote operationin the existing panel cubicle , etc, all the necessary accessories as required complete.

1

-

-

... More
Supply and fixing outdoor type START/STOP (2way) push button station (IP65) including all the necessary accessories as required complete with suitable mounting arrangement.(Cat No Hensel-PBS 0201 or equivalent approved make)

1

-

-

... More
Supply of indoor industrial surface mounted LED tube with Batten along with driver , surge protector,with a maximum system wattage of 40 Watts,lumen output of luminaire greater than 4000 lumen, power factor 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 100lumen/watt and including all necessary accessories as required complete.Make:- Cat No: WIPRO OPTIMA ll24 or equivalent make

12

-

-

... More
Supply of 10w LED Bulkhead fitting with die cast aluminium housing, PC diffuser and IP66 Protection suitable for operation on 230V 50Hz AC, wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire and making good the surface as required. (Make:Philips edura or equivalent approved make)

10

-

-

... More
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting/LED fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

22

-

-

... More
Numbering of ceiling fan / exhaust fan/ fluorescent fitting as required.

22

-

-

... More
Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date.

-

-

-

... More
3.5C 400 sqmm Al

600

-

-

... More
3.5C 185 sqmm Al

600

-

-

... More
3C 240 sqmm Al

24

-

-

... More
3C 25 sqmm Al

360

-

-

... More
3C 4 sqmm Cu

72

-

-

... More
2C 6 sqmm Cu

54

-

-

... More
4C 2.5 sqmm Cu

180

-

-

... More
Supplying and making end termination with brass double compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
3.5C 400 sqmm Al

4

-

-

... More
3.5C 185 sqmm Al

4

-

-

... More
3C 240 sqmm Al

2

-

-

... More
3C 25 sqmm Al

4

-

-

... More
3C 4 sqmm Cu

8

-

-

... More
2C 6 sqmm Cu

6

-

-

... More
4C 2.5 sqmm Cu

2

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.

-

-

-

... More
Cable size upto 35sq mm

100

-

-

... More
3 1/2 X 95 sq. mm

120

-

-

... More
3 1/2 X 120 sq. mm

240

-

-

... More
Laying of one number additional PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
Cable size upto 35sq mm

200

-

-

... More
Above 35 sq. mm and upto 95 sq. mm

250

-

-

... More
Above 185 sq. mm and upto 400 sq. mm

240

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required.

-

-

-

... More
Cable size upto 35sq mm

144

-

-

... More
3 X 185 sq. mm

102

-

-

... More
3 X 225 sq. mm

24

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on cable tray as required.

-

-

-

... More
Cable size upto 35sq mm

192

-

-

... More
3 1/2 X 35 sq. mm

98

-

-

... More
3 1/2 X 50 sq. mm

65

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.

-

-

-

... More
Cable size upto 35sq mm

30

-

-

... More
2 X 35 sq. mm

30

-

-

... More
2 X 50 sq. mm

55

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
150 mm width X 50 mm depth X 2 mm thickness

30

-

-

... More
300mm width X 50 mm depth X 2 mm thickness

40

-

-

... More
Fabrication, supply and installation of following size of Ladder Type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M8 threaded rod and all necessery accessories as required

-

-

-

... More
300 MM WIDTH X 50 MM DEPTH X 2 MM THICK

30

-

-

... More
Providing, laying and fixing following dia RCC pipe NP 2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required.

-

-

-

... More
150 mm dia

20

-

-

... More
300 mm dia

30

-

-

... More
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc. as required

-

-

-

... More
100 mm dia

15

-

-

... More
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

30

-

-

... More
Dismantling of existing electrical cables and also those components not explicitly mentioned here but required for the completion of job. Job includes the,de glanding, excavating , transportation of the cables from existing condtion,its stacking etc including supply of all tools, labour, lifting equipment, transportation equipment etc, complete as required as per the instruction of client/consultant. Dismantling of above cables including transportation and stacking of electrical equipments etc to the out of premises Oushadhi ,including supply of all tools, labour, lifting equipment, transportation equipment,etc complete as required as per the instruction of client/consultant.

200

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

4

-

-

... More
Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required.

-

-

-

... More
50mmX6mm GI

60

-

-

... More
25mm x 6 mm GI

30

-

-

... More
25mm x 3 mm Cu

40

-

-

... More
3.15mm Cu (10 SWG)

150

-

-

... More
Supplying and laying following GI or copper strip(tinned at the points of contacts) / wire at 0.6m below ground level including excavation and refilling for conductor earth electrode including welding etc as required.

-

-

-

... More
50mmX6mm GI

90

-

-

... More
25mm x 6 mm GI

30

-

-

... More
25mm x 3 mm Cu

40

-

-

... More
3.15mm Cu (10 SWG)

350

-

-

... More
Supply and providing ISI marked electrical 1.1 kV grade anti-skid insulated mat as per IS:15652.for the following sizes.

-

-

-

... More
2mx1mx2mm thick

6

-

-

... More
Supply and fixing of First aid box

1

-

-

... More
Supplying of Rubber hand gloves suitable for 1.1 KV.

1

-

-

... More
Supply and fixing anodised aluminum glass framed shock treatment chart.

1

-

-

... More
Supply and fixing single line diagram, schematic diagrams etc. of A1 size on suitable Aluminium sheet including lamination etc. as required complete on wall.

1

-

-

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

1

-

-

... More
Sump

-

-

-

... More
2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.

510

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

5

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

443.48

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

110.9

-

-

... More
od55980/2020_2021 : Disposal/stacking of building rubbish/ malba/ similar unserviceable, dismantled ,balance earth or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or within the site premises as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

5

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

38.94

-

-

... More
4.12 : Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification .

97216.54

-

-

... More
od55981/2020_2021 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. <br>All work upto plinth level

148.72

-

-

... More
od55982/2020_2021 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. <br>All work above plinth level upto floor V level

137.21

-

-

... More
od55983/2020_2021 : Extra for providing richer mixes at all floor levels.<br>Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).

285.93

-

-

... More
od55984/2020_2021 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete for all levels.<br>Thermo-Mechanically Treated bars of grade Fe-500D or more.

28922.77

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

54.05

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

679.58

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

423.72

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

111.21

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

18.38

-

-

... More
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide

125.8

-

-

... More
5.9.16.2 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsAbove 20 cm wide

41.93

-

-

... More
50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

9.28

-

-

... More
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

1

-

-

... More
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

63.79

-

-

... More
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

63.79

-

-

... More
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

14.18

-

-

... More
od55985/2020_2021 : Supplying and fixing rolling shutters of approved make,made of required size M.S laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets,side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs grade No.2 and M.S top cover of required thickness for rolling shutters including two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, including cost and conveyance of all materials, labour charges,lead,lift etc complete as directed by Engineer in Charge at all levels. 80 X 1.25 mm M.S.Laths with 1.25mm thick top cover

6

-

-

... More
10.7 : Providing and fixing ball bearing for rolling shutters.

2

-

-

... More
9.161 : Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontalside & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mmthick GI sheet ( Zinc coating not less than 120gm/m2) suita2ble for mounting 120min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineralwool Insulation having density min 96Kg/m2 . The frame will have a provision ofG.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style ofsize M10 x 80 ) suitable for fixing in the opening along with Factory madeTemplate for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire ratedglazed shutter . The frame shall be finished with a approved fire resistant primeror Powder coating of not less than 30 micron in desired shade as per thedirections of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded

6.2

-

-

... More
9.162 : Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minFire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certifiedas per laboratory approved by Engineer-in-charge, with suitable mounting ondoor frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mmwide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet(zinc coating not less than 120gm/m²) duly filled mineral wool insulation havingdensity min 96 kg/m³ and fixing with necessary stainless steel ball bearing hingesof size 100x89x3mm of approved make, including applying a coat of approvedfire resistant primer or powder coating not less than 30 micron etc all completeas per direction of Engineer-in-charge (panelling to be paid for seperately

1.68

-

-

... More
9.164 : Providing and fixing glazing in fire resistant door shutters, fixed panels & partitionsetc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mmfrom the edges and 150 mm c/c , including applying a coat of approved fire resistantprimer/powder coating of not less than 30 micron on G.I. beading, & special ceramictape of 5 x 20 mm size etc complete in all respect as per direction of Engineer-incharge.The glass shall be clear, toughened, interlayered, non-wired fire resistant having11 mm thickness of approved brand with 120 minutes of fire resistance both integrity &radiation control (EW120) and minimum 15 min of insulation (EI15) and having a soundreduction of ?37dB and LT of 86%. Glass shall be compliant to class 2(B)2 category ofImpact Resistance as per EN 12600. The glass should be manufactured in UL & TUVaudited Facility and including UL-EU Certification.The maximum glazing size cannotbe more than 1100 mm x 2200 mm (w x h) or 2.42 sq mts in total area. The test report forthe complete system (Glazed Door or Partition) will be considered valid only if it containsthe stamp and signature of the authorized signatory from the glass manufacturer.(Actual glass size is to be measured at site for payments).

0.42

-

-

... More
9.165.1 : Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125 mm

2

-

-

... More
od55986/2020_2021 : Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, etc. including cost and conveyance of all materials, labour, lead,lift etc. complete as directed by Engineer- in-Charge at all levels.<br>In gratings, frames, guard bar, ladders, railings, brackets, gates & similar works.

525.83

-

-

... More
od55987/2020_2021 : Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, etc. including cost and conveyance of all materials, labour, scaffolding, lead,lift etc. complete as directed by Engineer- in-Charge at all levels.<br>In stringers, treads, landings etc of staircases including use of chequered plate wherever required, all complete

227.4

-

-

... More
11.4 : 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete

119.49

-

-

... More
11.6.1 : Cement plaster askirting upto 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement .18 mm thick

7.26

-

-

... More
11.20.2 : Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Medium shade pigment using 50% white cement 50 % Grey cement

1

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

423.72

-

-

... More
13.1.2 : 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).

57.56

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

481.28

-

-

... More
13.44.1 : Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)

481.28

-

-

... More
13.21 : Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.

9994.05

-

-

... More
od55988/2020_2021 : 15mm cement plaster of mix, 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement 2 kg/sqm including mixing water proofing material in separately).proportion recommended by manufacturer over roof at all heights including cost and conveyance of all materials, labour charges, scaffolding, sundries etc complete as directed by the Engineer in charge at all levels. (water proofing liquid will be paid separately)

911.04

-

-

... More
22.22A : Providing and applying fibre reinforced elastomeric liquid water proofing membranewith resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top ofconcrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming ofelastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and twocoats of undiluted elastomeric waterproofing liquid (dry film thickness of completeapplication/system not less than 500 microns). The operation shall be carried outafter scrapping and properly cleaning the surface to remove loose particles withwire brushes, complete in all respect as per the direction of Engineer-in-Charge.

423.72

-

-

... More
22.23A : Providing & Applying polymer modified, flexible cementatious negative sidewaterproofing coating with elastic waterproofing polymers on interior wall plastersurface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatiouswaterproofing polymer(dilution with water in the ratio of 1:1) and two coats ofcementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) afterscrapping and properly cleaning the surface to remove pre-existing paint film &loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge.

487.31

-

-

... More
22.4.1 : Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:Serrated with central bulb ( 225 mm wide, 8-11 mm thick)

113.85

-

-

... More
od55989/2020_2021 : Providing and fixing light duty Cast Iron Manhole covers including cost and conveyance of all materials,labour charges,lead,lift etc complete as directed by Engineer in Charge.<br>600x600mm

4

-

-

... More
od55990/2020_2021 : Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required. (bituminous portion)

120

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.