The Kerala State Homeopathic Cooperative Pharmacy Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

The Kerala State Homeopathic Cooperative Pharmacy Limited Tender

Works
Coronavirus COVID 19
Eprocure
Opening Date5 Feb 2019
Closing Date25 Feb 2019
Tender Amount₹ 98,78,674 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Summary

Tender For Electrification Of The Existing Manufacturing Unit Of Homoeo Medicine

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, installation, testing and commissioning of a neutral CT of ratio 200/5A, CL: 5P10 ,15VA in a suitable metallic sheet steel enclosure in the transformer neutral for low set E/F protection, control cabling to the E/F relay including termination etc. complete.

1

-

-

... More
Supply Installation ,testing & commissioning of HT -TOD Meter for the above

1

-

-

... More
HT CABLE LAYING:-Supply and laying 3x300 Sqmm Aluminium conductor XLPE insulated PVC sheathed ,armoured 11 KV HT Cable from Two pole structure to 630 KVA Unitised substation.

70

-

-

... More
HT CABLE END TERMINATION:-Supply and providing HT cable termination with heat shrinkable end termination set for 3x300 Sq mm XLPE- HT Cable.

-

-

-

... More
Outdoor type

3

-

-

... More
Indoor type

1

-

-

... More
STANDBY DIESEL GENERATOR SETS

-

-

-

... More
Supply, Installation, testing and commissioning of 625 kVA, three phase D.G. Set with Acoustic Enclosure on the foundation provided near the Substation. (Civil works for the foundation will be done by the Owner).

1

-

-

... More
Supply, Fabrication and Fixing adequate size of exhaust line for 625kVA DG set.

3

-

-

... More
Errection, testing and commissioning of 63 kVA 415 Volts, 3 phase 50 Hz Diesel Engine Generator. (Civil works for the foundation will be done by the Owner).

1

-

-

... More
Supply, Fabrication and Fixing adequate size of exhaust line for 63kVA DG set.

3

-

-

... More
10 KVA UPS:-Supply,Installation testing and commisioning of 10 kVA (3 Phase input & 1Phase Output) UPS supply as per the design with battery (30minutes back up) and all accessories and giving neccessary connections complete as required.

1

-

-

... More
PANEL BOARDS:- Fabrication, conveyance, supply, installation, testing and commissioning of self-supported, free standing powder coated cubicle type, 415V, 36 kA Switch Board of CRCA No.14/16 gauge sheet steel construction with cable entry facility at top/bottom. Cable alley, switchgear compartment, meter chamber, bus bar chamber etc. shall be fully segregated & compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connections with 4 mm FRP. Control wiring shall be with 2.5 sq. mm copper cable of 1100 volt grade for CT leads and 1.5 sq. mm for voltage leads with 2A SP MCB. All meters, connectors, lamps etc. shall have safe finger proof terminals. Doors shall be provided with 4 sq. mm flexible copper and socketed earth leads of green/green and yellow stripped PVC insulation. The main earth bus shall be of size 25 x 3 mm copper and run through the switchboard for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock- outs of proper diameter shall be provided on glanding plates. Ring type CTs shall be rigidly fixed to the cable chamber walls so that socketed cable cores can be easily taken through the CTs. The height of the operating handle of any switch gear shall not be more than 1.8 metres or less than 0.6 metres from bottom level of the switch board. All MCCB's are rotary operated handle with spreader. Painting : Powder coated after seven tank metal treatment. Colour - Admiralty Grey as per I.S.S (RAL 7032). Enclosure : Degree of Protection - IP 54 or above. Doors / Cover : Doors with concealed hinges & bolted cover for bus chamber.Labelling : All incomers and outgoings shall be labelled. These name plates shall be of metal black colour base and white letter engraved and screwed to the panel or transparent acrylic sheet screwed for insertion of identification cards. PVC identification ferrule numbers shall be used for all internal wiring. The panel shall be provided with standard danger board.

-

-

-

... More
MSB:- Incommer -1 : 1000A, 50kA, FP Microprocessor Based Motorised ACB with Over current and Earth fault release. Incommer -2 : 1000A, 50kA, FP Microprocessor Based Motorised ACB with Over current and Earth fault release . Incommer -3: 125A, FP Isolator. BUS Coupler: 1000A, 50kA, FP Microprocessor Based Motorised ACB.125A FP Contactor -1No.PLC Based AMF with load sharing .Surge Protection Device (Type 1+2, Class I+II). Bus bars : Phase; 2x50x12 mm AL. Neutral; 1x50x12 mm AL..Outgoings:- 320A, 36kA, TPN MCCB - 3 No. 250A, 36kA, TPN MCCB - 4 No. 250A, 36kA, TPN Micro. Based MCCB- 1No. 125A, 36kA, TPN MCCB - 1 No. 160A TPN ISOLAOR - 1 No. Indication & Metering : RYB Indication -3 sets. Three phase multifunction meter to read V, A,F, PF and KW with CT's & control MCB - 1No. 1000/5A CL 1 15VA CT for APFC Relay - 1No. Earth Fault Relay with 150/5A CL 5P10 10VA CT - 1No.

1

-

-

... More
150kVAr APFC PANEL:- Incommer : 250A, FP 36kA MCCB - 1 No. Bus bars : Phase - 32 x 10 mm AL. Neutral - 32 x 6 mm AL. Outgoings : 63A, TP MCB - 5 No. 32A TP MCB - 1 No. 16A TP MCB - 1 No. 25kVAr capacitor with capacitor duty contactor - 4 No. 20kVAr capacitor with capacitor duty contactor - 1 No. 10kVAr capacitor with capacitor duty contactor - 1 Nos. 5kVAr capacitor with capacitor duty contactor - 1 No. 15kVAr capacitor without capacitor duty contactor - 1 No. Indication & Metering : RYB Indication -1 sets 0-300A Ammeter - 3 Nos. 250/5A, CL:1, 15 VA CT - 3 Nos. 0-500V Voltmeter with Selector Switch - 1 No. Eight stage APFC Relay with Auto/Manual provision - 1No.

1

-

-

... More
SSB-1:- Incommer : 315A, FP ISO - 1 No. Bus bars : Phase - 38 x 12 mm AL. :Neutral - 38 x 6 mm AL. Outgoings : 40A, TPN MCCB - 6 No. : 63A, TPN MCCB - 4 No. : 100A, TPN MCCB - 2 No. Indication & Metering RYB Indication -1 sets 0-350A Ammeter - 3 Nos. 350/5A, CL:1, 15 VA CT - 3 Nos. 0-500V Voltmeter with Selector Switch - 1 No.

1

-

-

... More
SSB-2:- Incommer : 315A, FP ISO - 1 No . Incommer:315A, FP ISO - 1 No. Bus bars : Phase - 38 x 12 mm AL. :Neutral - 38 x 6 mm AL. Outgoings : 40A, TPN MCCB - 6 No. : 63A, TPN MCCB - 4 No. : 100A, TPN MCCB - 1 No. Indication & Metering RYB Indication -1 sets 0-350A Ammeter - 3 Nos.350/5A, CL:1, 15 VA CT - 3 Nos. 0-500V Voltmeter with Selector Switch - 1 No.

1

-

-

... More
SSB-3:- Incommer : 315A, FP ISO - 1 No. Bus bars : Phase - 38 x 12 mm AL. :Neutral - 38 x 6 mm AL. Outgoings : 40A, TPN MCCB - 6 No.: 63A, TPN MCCB - 4 No. : 100A, TPN MCCB - 1 No. Indication & Metering RYB Indication -1 sets 0-350A Ammeter - 3 Nos.350/5A, CL:1, 15 VA CT - 3 Nos. 0-500V Voltmeter with Selector Switch - 1 No.

1

-

-

... More
FIRE PANEL:- Incommer : 125A, TPN ISO - 1 No. Bus bars : Phase - 25 x 6 mm AL. :Neutral - 25 x 6 mm AL. Outgoings : 63A, TPN ISO - 3 No.Indication & Metering RYB Indication -1 sets 0-100A Ammeter - 3 Nos. 50/5A, CL:1, 15 VA CT - 3 Nos. 0-500V Voltmeter with Selector Switch - 1 No.

1

-

-

... More
Labour charge for Dismantling, and Shifting of existing MSB Panel.

1

-

-

... More
Labour charge for Dismantling, and Shifting of existing SSB Panel.

2

-

-

... More
Supply, installation, testing and commissioning of 63A, FP, Isolator with enclosure.

3

-

-

... More
Supply, installation, testing and commissioning of 40A, FP, Isolator with enclosure.

5

-

-

... More
Supply, installation, testing and commissioning of 63A, DP, Isolator with enclosure.

1

-

-

... More
DISTRIBUTION BOARDS:- Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/MCCB or isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required.

-

-

-

... More
6way(8+18) double cover TPN vertical DB

2

-

-

... More
8way(8+18) double cover TPN vertical DB

4

-

-

... More
Supply and fixing of the following accessories suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure

-

-

-

... More
63A FP 100mA RCBO

4

-

-

... More
63A FP 30mA RCBO

2

-

-

... More
40A, 10kA TP MCB(C curve)

26

-

-

... More
32A, 10kA TP MCB(C curve)

18

-

-

... More
MV CABLE LAYING:- Supply and laying of one number XLPE aluminium armoured power cable of 1.1kV grade of the following sizes in ground including excavation of trench of size 35x75 cm, refilling the trench etc. as required

-

-

-

... More
3.5 x 400 Sqmm

70

-

-

... More
3.5 x 300 Sqmm

30

-

-

... More
3.5 x 240 Sqmm

30

-

-

... More
Supply and laying of one number XLPE aluminium armoured power cable of 1.1kV grade of the following sizes through cable rack/tray

-

-

-

... More
3.5 x 400 Sqmm

140

-

-

... More
3.5 x 300 Sqmm

45

-

-

... More
3.5 x 240 Sqmm

140

-

-

... More
3.5 x 185 Sqmm

15

-

-

... More
3.5 x 120 Sqmm

20

-

-

... More
3.5 x 95 Sqmm

90

-

-

... More
3.5 x 70 Sqmm

30

-

-

... More
3.5 x 50 Sqmm

140

-

-

... More
3.5 x 35 Sqmm

240

-

-

... More
4 x 25 Sqmm

110

-

-

... More
4 x 16 Sqmm

360

-

-

... More
4 x 10 Sqmm

270

-

-

... More
4 x 6 Sqmm

110

-

-

... More
3 x 16 Sqmm

30

-

-

... More
3 x 10 Sqmm

30

-

-

... More
2 x 25 Sqmm

30

-

-

... More
2 x 10 Sqmm

40

-

-

... More
2 x 6 Sqmm

60

-

-

... More
Supply and laying of one number 2XFY Copper armoured power cable of 1.1kV grade of the following sizes through cable rack/tray

-

-

-

... More
4 x 16 Sqmm

140

-

-

... More
4 x 10 Sqmm

100

-

-

... More
4 x 6 Sqmm

60

-

-

... More
4 x 4 Sqmm

40

-

-

... More
3 x 16 Sqmm

20

-

-

... More
3 x 10 Sqmm

20

-

-

... More
2 x 25 Sqmm

30

-

-

... More
2 x 10 Sqmm

20

-

-

... More
2 x 6 Sqmm

30

-

-

... More
2 x 4 Sqmm

40

-

-

... More
4 x 2.5 Sqmm

60

-

-

... More
2 x 2.5 Sqmm

60

-

-

... More
4 x 1.5 Sqmm

80

-

-

... More
12 x 1.5 Sqmm

80

-

-

... More
MV CABLE END TERMINATION:-Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.

-

-

-

... More
3.5 x 400 Sqmm

18

-

-

... More
3.5 x 300 Sqmm

2

-

-

... More
3.5 x 240 Sqmm

4

-

-

... More
3.5 x 185 Sqmm

1

-

-

... More
3.5 x 120 Sqmm

1

-

-

... More
3.5 x 95 Sqmm

2

-

-

... More
3.5 x 70 Sqmm

2

-

-

... More
3.5 x 50 Sqmm

6

-

-

... More
3.5 x 35 Sqmm

8

-

-

... More
4 x 25 Sqmm

4

-

-

... More
4 x 16 Sqmm

14

-

-

... More
4 x 10 Sqmm

12

-

-

... More
3 x 16 Sqmm

4

-

-

... More
3 x 10 Sqmm

2

-

-

... More
4 x 6 Sqmm

2

-

-

... More
2 x 25 Sqmm

4

-

-

... More
2 x 10 Sqmm

6

-

-

... More
2 x 6 Sqmm

2

-

-

... More
Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 kV grade as required.

-

-

-

... More
4 x 16 Sqmm

10

-

-

... More
4 x 10 Sqmm

8

-

-

... More
3 x 16 Sqmm

2

-

-

... More
3 x 10 Sqmm

2

-

-

... More
4 x 6 Sqmm

2

-

-

... More
2 x 25 Sqmm

2

-

-

... More
2 x 10 Sqmm

2

-

-

... More
2 x 6 Sqmm

2

-

-

... More
2 x 2.5 Sqmm

3

-

-

... More
4 x 1.5 Sqmm

4

-

-

... More
12 x 1.5 Sqmm

5

-

-

... More
CABLE TRAY:- Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

80

-

-

... More
300 mm width X 62.5 mm depth X 2.0 mm thickness

160

-

-

... More
450 mm width X 62.5 mm depth X 2.0 mm thickness

180

-

-

... More
600 mm width X 62.5 mm depth X 2.0 mm thickness

240

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

8

-

-

... More
300 mm width X 62.5 mm depth X 2.0 mm thickness

10

-

-

... More
450 mm width X 62.5 mm depth X 2.0 mm thickness

8

-

-

... More
600 mm width X 62.5 mm depth X 2.0 mm thickness

7

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

1

-

-

... More
300 mm width X 62.5 mm depth X 2.0 mm thickness

1

-

-

... More
450 mm width X 62.5 mm depth X 2.0 mm thickness

1

-

-

... More
600 mm width X 62.5 mm depth X 2.0 mm thickness

1

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required..

-

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

1

-

-

... More
300 mm width X 62.5 mm depth X 2.0 mm thickness

1

-

-

... More
450 mm width X 62.5 mm depth X 2.0 mm thickness

1

-

-

... More
600 mm width X 62.5 mm depth X 2.0 mm thickness

1

-

-

... More
EARTHING:-Supply and laying following sizes of strips laid 0.6m below ground level including excavating trench of suitable size and refilling etc. as required.

-

-

-

... More
25x3 mm copper strip

45

-

-

... More
25x6 mm copper strip

30

-

-

... More
32x6 mm copper strip

50

-

-

... More
Supply and clamping the following sizes of strips on surface of wall/ existing cable tray using clamps fabricated from 20x3 mm GI fat duty painted or heavy duty GI spacer saddles, spacing of saddles not exceeding 1 mtr, making good the damages colour washing etc. as required.

-

-

-

... More
25x3 mm copper strip

240

-

-

... More
25x6 mm copper strip

20

-

-

... More
32x6 mm copper strip

20

-

-

... More
Supply and drawing bare earthing conductors of the following size along with wiring/cables and giving connection as required.

-

-

-

... More
10 SWG bare copper

800

-

-

... More
8 SWG bare copper

410

-

-

... More
Supply and providing Plate Earthing as per IS 3043 with 1200 X1200 X 12 mm GI/CI earth plate, 50 mm GI Watering pipe fixed to the earth plate with 25x3 mm GI clamps, GI funnel with weld mesh, filling required quantity of charcol including construction of Earth pit inspection champer and Heavy duty C.I. Chequered plate for Earthpit Inspection Chamber cover etc. (Including all civil works)

4

-

-

... More
Supply and providing Plate Earthing as per IS 3043 with 600 X600 X 12 mm GI/CI earth plate, 50 mm GI Watering pipe fixed to the earth plate with 25x3 mm GI clamps, GI funnel with weld mesh, filling required quantity of charcol including construction of Earth pit inspection champer and Heavy duty C.I. Chequered plate for Earthpit Inspection Chamber cover etc. (Including all civil works)

5

-

-

... More
Earthing with G.I. earth pipe 2.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.(Including all civil works)

1

-

-

... More
MISCELLANEOUS ITEMS.

-

-

-

... More
Supply and providing HT Danger board

2

-

-

... More
Supply and providing LT Danger board

2

-

-

... More
Supply and providing HT Rubber glouse

2

-

-

... More
Supply and providing fire bucket -3 Nos with stand

1

-

-

... More
Supply and providing 12 mm Thick Rubber mat (Electrical grade-2m X 1m size)

3

-

-

... More
Supply and providing 5Kg dcp type Fire extinguisher

2

-

-

... More
Supply and providing neatly framed schematic layout

2

-

-

... More
Supply and fixing of shock treatment chart

2

-

-

... More
APPROVAL & SANCTION

-

-

-

... More
Professional charges for preparation of drawings, getting approval from the Electrical Inspectorate , submission of completion report, follow up action for getting sanction for energisation, complying all formalities with Electrical Inspectorate for getting power connection.All expenses excluding statutary charges. Statutary charges shall be paid by the client.

1

-

-

... More
Professional charges for preparation of documents, submission of completion report, follow up action for getting power connection from KSEB, complying all formalities. All expenses excluding statutary charges. Statutary charges shall be paid by the client.

1

-

-

... More
Appendix B:- LV WORK :- Supply, wiring and fixing following sockets with modular plate & suitable GI box including all the connections.

-

-

-

... More
RJ 11 Telephone Socket

15

-

-

... More
RJ 45 Data Socket Outlet

24

-

-

... More
Supply and Laying of 2Pair Telephone Cable in the existing surface/recess conduit.

200

-

-

... More
Supply and Laying of 10Pair Telephone Cable in the existing surface/recess conduit.

210

-

-

... More
Supply and Laying of CAT 6 Cable in the existing surface/recess conduit.

1240

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.