Technopark Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Technopark Tender
Electrical and Electronics
Eprocure
Opening Date24 Feb 2024
Closing Date26 Mar 2024
Tender Amount₹ 14,71,000
Costs
EMD
₹ 22,065Document Cost
₹ 2,950Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ETPK_663533_1Bid Award Id
ViewTender No
ETPK/PH-III/2023-24/E-08Tender Authority
Technopark ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
630A,50kA, 4P,Micro procesor type draw out type ACB with 3 O/C & 1 E/F releases and all accessories -1 Nos
-
-
-
100/5A ,10VA cast resin type,Class 5P10 CT- 1Nos
-
-
-
400/5A,10 VA,Cast resin type ,CL:1 ,CT-3 Nos
-
-
-
Earth Fault Relay- 1Nos
-
-
-
Digital Multifunction meter (VAF + W/VA/PF/Wh) LED meter Cl 1 with RS485 -1Nos
-
-
-
Outgoings:
-
-
-
400A,36kA, 4P,Thermal magnetic type MCCB with all accessories including spreader link and extended rotary handle-1 Nos
-
-
-
200A,36kA, 4P,Thermal magnetic type MCCB with all accessories including spreader link and extended rotary handle-1 Nos
-
-
-
Sub Panel
1
-
-
Fabrication Supply installation testing and commissioning of 400A, LT, floor mounted type, dust and vermin proof, free standing, cubical type construction, made out 14SWG thick CRCA sheet fully compartmentalised, duly rust inhibited, degreased, zinc phosphated and powder coating painted with approved colour and quality, complete with hinged and earthed front doors, name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel with CT Digital ammeters with cast resin type CTs and Digital Voltmeter with selector switch, indication lamps,high conductivity wrought aluminium busbars with SMC supports, heat shrinkable sleeves etc. all connections and inter-connections including mounting the following switch gears as per SLD with IP54
-
-
-
Incomer:
-
-
-
400A,36kA, 4P,Thermal magnetic type MCCB with all accessories including spreader link and extended rotary handle-1 Nos
-
-
-
Digital Multifunction meter (VAF + W/VA/PF/Wh) LED meter Cl 1 with RS485 -1Nos
-
-
-
400/5A,10 VA,Cast resin type ,CL:0.5s ,CT-3 Nos
-
-
-
Outgoings:
-
-
-
250A,25kA, 4P,Thermal magnetic type MCCB with all accessories including spreader link and extended rotary handle-2 Nos
-
-
-
125A,25kA, 4P,Thermal magnetic type MCCB with all accessories including spreader link and extended rotary handle-2 Nos
-
-
-
3-phase TOD meter,class 0.5s with RS 485 communication port - 3Nos
-
-
-
200/5A ,10VA cast resin type,Class 0.5s CT -3 Nos
-
-
-
100/5A ,10VA cast resin type,Class 0.5s CT-6 Nos
-
-
-
Power Cables
-
-
-
Removing of existing 11kV feeder cables from the existing routes without any damage in the system (work including dismatling of existing cables termination,removing cable from existing route,connection, etc)
-
-
-
3Cx185 Sqmm Cable
30
-
-
Supply of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size.
-
-
-
3Cx185 Sqmm Cable
40
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KVgrade of following size direct in ground in the same trench in one tier horizontal formationincluding excavation, sand cushioning, protective covering and refilling the trench etc
-
-
-
3Cx185 Sqmm Cable
40
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct/TRAY/RCC/ HUME / STONE WARE/ GI/ DWC pipe / Concrete trench/Clamping on wall etc. as required.
-
-
-
3Cx185 Sqmm Cable
10
-
-
Supply & laying of Following XLPE (Aluminium) power cable, conductors of best conductivity aluminium 1.1kV grade of the following sizes in the existing TRAY/RCC/ HUME / STONE WARE/ GI/ DWC pipe / Concrete trench/Clamping on wall etc. as required.
-
-
-
3.5Cx400 Sqmm
30
-
-
3.5Cx300 Sqmm
75
-
-
3.5Cx150 Sqmm
10
-
-
3.5Cx70 Sqmm
50
-
-
3.5Cx35 Sqmm
170
-
-
4Cx10 Sqmm
15
-
-
Supply & Laying of XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
-
-
-
3.5Cx300 Sqmm
75
-
-
3.5Cx70 Sqmm
10
-
-
3.5Cx35 Sqmm
140
-
-
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required.
-
-
-
3Cx185 Sqmm Cable
2
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
-
-
-
3.5Cx400 Sqmm Cable
6
-
-
3.5Cx300 Sqmm Cable
2
-
-
3.5Cx150 Sqmm Cable
2
-
-
3.5Cx70 Sqmm Cable
2
-
-
3.5Cx35 Sqmm Cable
6
-
-
4Cx10 Sqmm Cable
2
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
-
-
-
2Rx1.5sqmm with 1R 1.5sqmm Green wire for earthing
30
-
-
2Rx2.5sqmm with 1R 1.5sqmm Green wire for earthing
10
-
-
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, IP43, duly powder painted, inclusive of 100 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.
-
-
-
3P 4W VDB
1
-
-
Supplying and fixing 40A, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1
-
-
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following pole in the existing MCB DB complete with connections, testing and commisioning.
-
-
-
5A to 32A ,SP MCB
3
-
-
5A to 32A ,TPN MCB
3
-
-
Wiring for two light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
1
-
-
Wiring for three light point controled with one switch with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
2
-
-
Supply and fixing of 20 W, LED 4 feet wall mounted LED battern CRI = 80,PF=0.95 ,CCT 5700K,Efficacy =95
4
-
-
Supply and Installation of Independent plug point with 6A 3 pin plug socket controlled by 6A switch with suitable modular plate, GI box/PVC box in recess/ surface .
1
-
-
Supply and Installation of Independent plug point with 16A plug socket controlled by 16A switch with suitable modular plate ,GI box/PVC box in recess/ surface .
1
-
-
Supplying and fixing of 20mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
30
-
-
Supply and fixing 25 mm X 6 mm G.I. strip on surface or in recess for connections etc. as required.
300
-
-
Supply and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
15
-
-
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
3
-
-
Supply and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
25
-
-
Lifting&Transportation of 500kVA transformer from Technopark 110kV substation, Phase III to outdoor electrical room at Technopark Phase III campus(aproax2km) through public road
1
-
-
Overhauling of 500kVA Oil type transformer including oil leak arresting, oil refilling, BDV Testing, Oil testing, repairing of gaskets etc. as per tender conditions.
1
-
-
Erection,Testing and Commisioning of the 500kVA oil type transformer including transportation charges and necessary alteration work for transformer with essencial modification works for civil foundation etc. as required. The transformer shall be commissioned by performing all standard tests according to IS 10028 & necessary rules as per KSEI standards
1
-
-
Dismantling of existing Transformer,cable end terminations(3C×150Sq.mm.&3.5C×185 cables) and relocation of Transformer to a location as specified by Technopark engineer(max distance upto 1km)
1
-
-
Spray Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats after cleaning .
20
-
-
Supply and erection of vertical and horizontal type cable trays and cable supports fabricated out of MS angles (ISA) and MS flats with sufficient width and spacing between successive cross members and supported at adequate spacing. The cable trays and supports shall be painted with two coats of Zinc Chromate primer and two coats of enamel paint. (Size as specified by Technopark as per site conditions)
814
-
-
Supply and providing 3 mm thick sythetic type and 1 m wide electrical grade chequered type rubber mat to withstand 3.3 kV dielectric strength conforming to IS 15652 (2006).
4
-
-
Supply of CO2 Extinguisher 4.5Kg, Fire rating of 55B, PESO approved Aluminium cylinders with CCOE certification, IS 15683:2018 standard, Certifications from BIS, EN, CE, ISI and date of manufacture imprinted on cylinder, coated with High Glossy PU Paint, anti corrosive make, Discharge hose with the conductive wires to dissipate the static charge generated during CO2 discharge, Carbon dioxide gas having a purity of 99.5% and conforming to IS15222, “D” handle for ease of carrying and operator safety, Cold impact extrusion can, Used-Unused Mechanism, Squeeze Grip, Gross Weight 11.16 Kg, Empty Weight 6.66Kg, Can Height 860mm, Diameter 140mm, Discharge time minimum 8 Seconds, Controllable discharge mechanism, Range minimum 2m, two piece floating spindle valve with a handwheel to operate, venyl sticker/label with all the details including operational instructions, 10 years warranty
3
-
-
Preparation of all drawings submitting and getting approval from electrical inspectorate by a Licensed A Class Electrical Contractor for the electrification of proposed modules, load additions and modification works which include current and past additions in the existing Transformer, DG, HT & LT panels, submitting of Completion certificates and arranging inspection, getting sanction and energization certificate etc, providing and fixing neatly Laminated Electrical schemes and layout for Thejaswini Substation
1
-
-