Steel Industrials Kerala Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 26,668Document Cost
₹ 2,950Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_SILK_692655_1Bid Award Id
ViewTender No
SILK/SBU(B)/2024/2267BTender Authority
Steel Industrials Kerala Limited ViewPurchaser Address
-Website
http://https://steelindustrials.net/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
3
-
-
... More
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1
-
-
... More
90.15.4.7 : Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
4
-
-
... More
90.15.4.8 : Supply Conveyance, installation, testing and commissioning of 120W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
8
-
-
... More
90.15.4.9 : Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
14
-
-
... More
Dismantling and relocation of 3 Nos of Existing Highmast foundation
-
-
-
... More
15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
6.64
-
-
... More
15.6 : Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B work.
341.94
-
-
... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
14.7
-
-
... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
2.45
-
-
... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
0.82
-
-
... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
25.32
-
-
... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
341.89
-
-
... More
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
6.64
-
-
... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
6.82
-
-
... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
8.21
-
-
... More
Electrical
-
-
-
... More
od116312/2024_2025 : [Derived From 90.15.2.3] Supply of 24mm diameter (4 numbers) foundation bolts of 750mm bolt length, 385mm pitch circle diameter manufactured from special steel along with nuts, washers, anchor plate and common template.( suitable for 12 M highmast system)
3
-
-
... More
od102474/2024_2025 : Labour charges for disconnecting, dismantling, assembling and rewiring of high mast system etc all complete including commissioning for relocation of Highmast systems.
3
-
-
... More
od123087/2024_2025 : [Derived From 90.15.2.3] Crane operation charges for relocation of 12 m Highmast pole.
3
-
-
... More
Maintenance - Phase 2
-
-
-
... More
od52333/2024_2025 : Supply and installation of digital/analog timer with weather resistant, IP 65 rated device having astronomical clock, weekly scheduled and manual override capabilities, designed to automate and control for minimast/ highmast operations.
6
-
-
... More
od116177/2024_2025 : Supply and fixing HRC fuse base of 32 A using suitable nut and bolt, 32 A 2- way neutral links mounted on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable.
3
-
-
... More
od116340/2024_2025 : Supply and installation of Selector switch for control operation & functioning of motor for High mast .
3
-
-
... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
3
-
-
... More
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
3
-
-
... More
od117202/2024_2025 : Supply and Installation of dust and vermin proof powder coated, 1 phase syntax meter board(GS-MB-375), Size- 35cmx18cm & 45cm in depth and to fix KSEB meters, fuse units, CT etc., can operate in temperatures ranging from -20°C to 50°C. Electrically, the box is rated for 230V AC or 24V DC, with a current rating of 10-50 A and a power rating of 100-500 W having environmental ratings of IP55 or IP65 for dust and water protection and box features a hinged, lockable door with a transparent viewing window, and can be mounted on a wall or floor as required including fixing it on wall, making good the damages color washing etc., as required.
3
-
-
... More
od116183/2024_2025 : Supply and fixing of 25A 2 Pole AC 1 rated power contactor, 25A Connector,<br>Digital timer, Suitable Copper socket, 2.5 sq.mm ISI marked FRLS PVC insulated single core copper conductor cable, 1.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable.
3
-
-
... More
od116184/2024_2025 : Supply Conveyance and Installation of Surge protector device of IP 20,Mounting type: Screw,Voltage protection level(UP),Nominal voltage:230V ,UOC:10KV,L-N:7 KV,L-PE:7 KV,N-PE:7 KV,Nominal discharge current (8/20):10 KA,Total discharge current (8/20):60 KA, Response time :<35 ns, Ta: -10-55.
3
-
-
... More
2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
3
-
-
... More
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
3
-
-
... More
90.15.4.11 : Supply Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
18
-
-
... More
Taxable Amount = Rs. 10,66,731.00
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements