Steel Industrials Kerala Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 49,171Document Cost
₹ 2,950Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_SILK_652683_1Bid Award Id
ViewTender No
SILK/GEW/SP/2023-24/41Tender Authority
Steel Industrials Kerala Limited ViewPurchaser Address
-Website
http://https://steelindustrials.net/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
14.9
Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
0.4
-
-
14.10
Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
2.09
-
-
od249043/2023_2024
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and
binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more
110.46
-
-
90.15.1.1
Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet
70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters
4
-
-
Installation, testing and commissioning 150 W Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/ Lumilled/ Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly
accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced
mentioning chip manufacturer)
20
-
-
90.14.1.2
Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.brFabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar
chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required.
CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the
fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for
panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using
1.6mm CRCA sheet, powder coated (excluding base frame)
8
-
-
90.14.3.2
Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding
suitable for 1.60/ 2.00 mm sheet
8
-
-
90.14.5
Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel
board
40
-
-
od249044/2023_2024
Supply and fixing of 2 nos of Digital timer, suitable copper socket, 2.5 Sq.mm ISI marked FRLS PVC insulated single core copper conductor cable, 1.5 sq.mm ISI marked FRLS PVC insulated single core copper conductor cable, Surge Protector (switching/lighting protection ) for single phase protection,1 No.of over voltage under voltage protector.
4
-
-
od249045/2023_2024
Supply and fixing HRC fuse base of 20/32 A using suitable nut and bolt, 32 A 2- way neutral links mounted on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable.
4
-
-
2.14.2
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
4
-
-
2.10.3
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
4
-
-
2.12.1
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete
with connections, testing and commissioning etc. as required.40 amps
4
-
-
90.6.5.11
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
60
-
-
90.6.5.19
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm
40
-
-
5.3
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding
masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.
(but without charcoal/ coke and salt ) as required.
8
-
-
90.16.4.2
Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using
clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps
not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3
mm GI strip
32
-
-
90.16.1.3
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required3.15 mm copper conductor ( 10 SWG)
8
-
-
90.16.5.3
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.3.15 mm (10 SWG)
12
-
-
90.12.1.38
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 4 sq mm
32
-
-
90.12.9.2
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
32
-
-
9.1.2
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.2 X 10 sq. mm (19mm)
4
-
-
od307487/2023_2024
Charges for KSEB connection including all laison works (Actual Amount paid on production of receipt).
4
-
-
Miscellenous Works
-
-
-
Supply and fixing of name board with angles, flats, square pipe, ACP sheet including nut and bolts. 2 nos
per mast, 2Sqm in area.
4
-
-
Fabrication supply conveyance and installation of Granite name board indicating the cost involved,
commencement date, completion date and inaguration date etc.
4
-
-
Supply and Installation Of 02 Nos. of 10 Mtr High Mast with 6x180W LED Flood Lights in Kuttanad LAC, Alappuzha District.
-
-
-
Civil and Electrical works for Mast
-
-
-
14.1
Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m
including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead
of 50 metres.
5.47
-
-
14.9
Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
0.42
-
-
14.10
Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
2.48
-
-
od253884/2023_2024
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and
binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more
196.96
-
-
90.15.2.2
Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/two
sections of hot dip galvanised GI sheet 70mm top diameter, 130mm bottom diameter thickness 3mm
base plate dimensions of 200x200x16 mm suitable for wind speed as per IS 875 Part III with head frame
assembly two point suspension system with steel wire rope 5mm dia double drum winching system w and
including round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetrical
arrangement control gear box and lighting spikes with single phase operation power tool installed inside
the base compartment including connector foundation bolt 4 nos fixed in existing RCC foundation and
junction box etc, complete 10 Meters
2
-
-
installation, testing and commissioning of 180W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree /Lumilled /Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly
accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced
mentioning chip manufacturer)
12
-
-
od253885/2023_2024 Supply and installation of Twin unit aviation LED obstruction light with stand yellow-painted die-cast
aluminium alloy housing, red coloured polycarbonate dome and BC /EC lamp holders suitable for LED
lamp
2
-
-
90.14.1.2
Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.brFabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar
chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required.
CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the
fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for
panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using
1.6mm CRCA sheet, powder coated (excluding base frame)
4
-
-
90.14.3.2
Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding
suitable for 1.60/ 2.00 mm sheet
4
-
-
od253886/2023_2024
Supply and installation of 2 nos of Digital timer,suitable copper socket, 2.5 Sq.mm ISI marked FRLS PVC insulated single core copper conductor cable, 1.5 sq.mm ISI marked FRLS PVC insulated single core copper conductor cable, Surge protector (switching/lighting protection ) for single phase protection.1 nos of over voltage under voltage protector
2
-
-
od253887/2023_2024
Supply and fixing HRC fuse base of 20/32 A using suitable nut and bolt, 32 A 2- way neutral links mounted on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable
2
-
-
90.14.5
Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel
board
20
-
-
od253888/2023_2024
Supply and fixing of f 2 Nos of 18 A 3 Pole AC 1 rated power contactor, selector switch for motor control
,supply and fixing flush head push button NO-NC and 2.5 sq.mm ISI sq.mm ISI marked FRLS PVC
insulated single core copper conductor cable ,1.5 sq.mm ISI marked FRLS PVC insulated single core
copper conductor cable.
2
-
-
2.10.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Single pole
2
-
-
2.10.3
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Double pole
2
-
-
2.12.1
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete
with connections, testing and commissioning etc. as required.40 amps
2
-
-
2.14.2
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 amps
2
-
-
90.6.5.11
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V
grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface /
recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq
mm
18
-
-
90.6.5.19
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm
12
-
-
5.3
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding
masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.
(but without charcoal/ coke and salt ) as required.
4
-
-
90.16.4.2
Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using
clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps
not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3
mm GI strip
8
-
-
90.16.1.3
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required3.15 mm copper conductor ( 10 SWG)
4
-
-
90.16.5.3
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.3.15 mm (10 SWG)
10
-
-
90.12.1.38
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 4 sq mm
16
-
-
90.12.9.2
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
16
-
-
9.1.32
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.4 X 10 sq. mm (25mm)
4
-
-
od316933/2023_2024
Charges for KSEB connection including all laison works (Actual Amount paid on production of receipt).
2
-
-
Miscellenous Works
-
-
-
od253882/2023_2024
Supply and fixing of name board with angles, flats, square pipe, ACP sheet including nut and bolts. 4 nos
per mast, 2Sqm in area.
2
-
-
od253883/2023_2024
Fabrication supply conveyance and installation of Granite name board indicating the cost involved,
commencement date, completion date and inaguration date etc.
2
-
-
Supply and Installation of 01 No. of 12Mtr. High Mast (Motorized) with 6x200W LED Flood Lights at various locations in Kuttanad LAC Alappuzha District
-
-
-
Civil and Electrical works for Mast
-
-
-
14.1
Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m
including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead
of 50 metres.
4.9
-
-
14.9
Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
0.27
-
-
14.10
Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
2.21
-
-
od254061/2023_2024
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and
binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more
112.76
-
-
90.15.2.3
Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/two
sections of hot dip galvanised GI sheet 100mm top diameter, 360mm bottom diameter thickness 3mm
mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system
with steel wire rope 5mm dia double drum winching system w and including round arm galvanized
luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box and
lighting spikes with single phase operation power tool installed inside the base compartment including
connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc, complete 12
Meters
1
-
-
Installation, testing and commissioning of 200W LED Flood light output greater than
105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor
greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast
Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98,
RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly
accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced
mentioning chip manufacturer)
6
-
-
od254062/2023_2024
Supply and installation of twin unit aviation LED obstruction light with stand yellow- painted die-cast
aluminum alloy housing, red coloured polycarbonate dome and BC/ EC lamp holders suitable for LED
lamp.
1
-
-
90.14.1.2
Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust
and vermin proof, cubicle type MV panel board comprising of the following components/ devices &
complying to IS 8623.brFabrication of fully partitioned, dust and vermin proof enclosure for panel
assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design
and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear
compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs
for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar
chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required.
CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the
fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for
panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using
1.6mm CRCA sheet, powder coated (excluding base frame)
2.5
-
-
90.14.3.2
Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding
suitable for 1.60/ 2.00 mm sheet
2
-
-
od254063/2023_2024
Supply and fixing of 2 nos of Digital timer, suitable copper socket, 2.5 Sq.mm ISI marked FRLS
PVCbrinsulated single core copper conductor cable, 1.5 sq.mm ISI marked FRLS PVC insulated single
corebrcopper conductor cable, Surge Protector (switching/lighting protection ) for single phase
protection,1brNo.of over voltage under voltage protector.
1
-
-
od254064/2023_2024
Supply and fixing of 2 Nos of 18 A 3 Pole AC 1 rated power contactor, selector switch for motor control
,supply and fixing flush head push button NO-NC and 2.5 sq.mm ISI sq.mm ISI marked FRLS PVC
insulated single core copper conductor cable ,1.5 sq.mm ISI marked FRLS PVC insulated single core
copper conductor cable.
1
-
-
90.14.5
Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel
board
15
-
-
od254065/2023_2024
Supply and fixing of HRC fuse base of 20/32A using suitable nut and bolt, 32A 2-way neutral link
mounted on DMC/SMC base and 2.5Sqmm ISI marked FRLS PVC insulated single core copper
conductor cable
1
-
-
2.14.2
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 amps
1
-
-
2.10.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Single pole
1
-
-
2.10.3
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
1
-
-
2.12.1
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete
with connections, testing and commissioning etc. as required.40 amps
1
-
-
90.6.5.11
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V
grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface /
recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq
mm
18
-
-
90.6.5.19
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V
grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface /
recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq
mm
14
-
-
5.3
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding
masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required
2
-
-
90.16.4.2
Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using
clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps
not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3
mm GI strip
10
-
-
90.16.1.3
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required3.15 mm copper conductor ( 10 SWG)
2
-
-
90.16.5.3
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.3.15 mm (10 SWG)
6
-
-
90.12.1.38
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of
1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling
the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core
4 sq mm
10
-
-
90.12.9.2
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of
HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all
required accessories in ground in the existing trench50/38 mm or nearest size
10
-
-
9.1.2
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.2 X 10 sq. mm (19mm)
2
-
-
od317253/2023_2024
Charges for KSEB connection including all laison works (Actual Amount paid on production of receipt)
1
-
-
Miscellenous Works
-
-
-
od254059/2023_2024
Supply and fixing of name board with angles, flats, square pipe, ACP sheet including nut and bolts. 2 nos per mast, 2Sqm in area
1
-
-
od254060/2023_2024
Fabrication supply conveyance and installation of Granite name board indicating the cost involved,
commencement date, completion date and inaguration date etc.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements