Steel Industrials Kerala Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
₹ 2,950Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_SILK_390577_1Bid Award Id
ViewTender No
SILK/SBU-A/2020-21/879Tender Authority
Steel Industrials Kerala Limited ViewPurchaser Address
-Website
http://https://steelindustrials.net/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
2.25
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not
exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m
and lift up to 1.5 m.
43.7
-
-
5.2.2
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth
and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level
excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand :
3 graded stone aggregate 20 mm nominal size)
4.56
-
-
5.1.2
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of
centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse
sand :3 graded stone aggregate 20 mm nominal size
14.27
-
-
5.3 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings,
balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor
five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement :
1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
33.46
-
-
5.9.1
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of
columns, etc for mass concrete
34.68
-
-
5.9.3
Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs,
landings, balconies and access platform
153
-
-
5.9.16.1
Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in
floors and wallsUnder 20 cm wide
80.3
-
-
5.9.19
Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels
etc., including edges
35.4
-
-
5.9.5
Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams,
girders bressumers and cantilevers
131.61
-
-
5.9.6
Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers,
Abutments, Posts and Struts
68.4
-
-
5.22.6
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and
binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
1069.68
-
-
5.22A.6
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and
binding all complete above plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
2361.41
-
-
50.9.1.1
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed
and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or
dash fastener shall be paid for separately), using good quality Anjili wood /jack wood
0.05
-
-
50.9.2.1 Providing and fixing paneled and glazed shutters for doors, windows and clerestory windows, 35 mm
thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with
necessary screws, excluding panelling which will be paid for separately, all complete as per direction of
Engineerin - charge.using Anjili/ Jack wood
1.64
-
-
9.7.7.1
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for
doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside
grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40
mm thick:Float glass panes4 mm thick glass pane
12.17
-
-
10.6.3
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked
together through their entire length and jointed together at the end by end locks, mounted on specially
designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push
and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire
springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1
and M.S. top cover of required thickness for rolling shutters.80x0.90 mm M.S. laths with 0.90 mm thick to
cover
5.6
-
-
11.36
Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be
specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green,
black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm
thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg
per sqm, including pointing in white cement mixed with pigment of matching shade complete.
10.5
-
-
11.37
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the
manufacturer), of 1st quality conforming to IS: 15622, of approved make, in colours such as White, Ivory,
Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including
pointing the joints with white cement and matching pigment etc., complete.
3.3
-
-
11.41.2
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer)
with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and
shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints
with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
113.13
-
-
13.50.1
Applying priming coat:With ready mixed pink or Grey primer of approved and manufacture on wood work
(hard and soft wood)
1.89
-
-
13.61.1
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or
more coats on new work
35.15
-
-
13.1.1
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
396.05
-
-
13.16.1
6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
188.4
-
-
13.48.1
Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per
manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including
one coat of special primer applied @ 0.75 ltr /10 sqm
584.45
-
-
50.6.7.1
Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement
mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.
5.54
-
-
50.6.7.2
Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement
mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour
charges etc
21.79
-
-
10.15.1
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular
/L-Type sections, made of 1.60 mm thick M.S. Sheet,joints mitred, welded and grinded finish, with profiles
of required size, including fixing of necessary butt hinges and screws and applying a priming coat of
approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block
15x10x10 cm of C.C. 1:3:6 ( 1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
1398.3
-
-
2.31
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up
to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50
m outside the periphery of the area cleared
500
-
-
PVC DOOR
1
-
-
PLUMPING
-
-
-
17.2.2
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat
and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled
device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and
making good the walls and floors wherever required:W.C. pan with ISI marked black solid plastic seat
and lid
1
-
-
17.7.4
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste
of standard pattern, including painting of fittings and brackets, cutting and making good the walls
wherever require:White Vitreous China Flat back wash basin size 550x400mm with single 15 mm
C.P.brasspillar taps
1
-
-
17.28.1.1
Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC.waste fittings complete.Semi
rigid pipe32 mm dia
1
-
-
50.17.1.1
Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc
complete as per the direction of site Engineer-in-charge.
1
-
-
50.17.1.3
Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and
labour charges etc complete as per the direction of site Engineer-in-charge.
1
-
-
50.17.1.4
Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc.
complete as per the direction of site engineer-in-charge.
1
-
-
50.18.7.2.1
Providing and fixing PVC pipes, fittings including fixing the pipe with claps at 1.00 metre spacing. This
includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as
per direction of Engineer-in-Charge 20 mm dia 12Kgf/cm2 - Internal work - Exposed on wall
15
-
-
50.18.7.2.2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This
includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as
per direction of Engineer -in-Charge 20 mm dia 10 Kgf/cm2- Internal work - Exposed on wall
15
-
-
50.18.9.9.2
Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching,
refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2
7
-
-
18.48
Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked,
with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow
pipes but without fittings and the base support for tank.
500
-
-
Providing and installation of PVC septic tank for 25 flush per day
1
-
-
CHIMNEY FOUNDATION
-
-
-
2.8.1
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation
trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and
ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus
excavated soil as directed, within a lead of 50 m.All kinds of soil
18.23
-
-
2.26.1
Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked
materials.All kinds of soil
7.29
-
-
4.1.8
Providing and laying in position cement concrete of specified grade excluding the cost of centering and
shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40
nominal size)
0.73
-
-
51.2.4
Filling with Sand
Supplying and filling sand in foundation trenches of culvert for stabilizing the top clay layer including
watering, ramming, consolidating and dressing, etc complete for improving bearing capacity of soil.
1.09
-
-
5.1.2
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of
centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse
sand :3 graded stone aggregate 20 mm nominal size
9.41
-
-
6.1.1
Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and
plinth in:Cement mortar 1:4 (1cement: 4 coarse sand)
4.31
-
-
5.9.1
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of
columns, etc for mass concrete
1.56
-
-
5.22.6
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and
binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
470.7
-
-
WASTE WATER TANK
-
-
-
2.8.1
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation
trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and
ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus
excavated soil as directed, within a lead of 50 m.All kinds of soil
5.63
-
-
4.8.1
Providing and fixing up to floor five level precast cement concrete hollow block, including hoisting and
setting in position with cement mortar 1:3 ( 1 cement : 3 coarse sand), cost of required centering,
shuttering complete:1:1.5:3 ( 1 cement : 1.5 coarse sand (Zone III): 3 graded stone aggregate 20 mm
nominal size)
0.38
-
-
5.9.3
Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs,
landings, balconies and access platform
4.95
-
-
5.22.6
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and
binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
42.19
-
-
5.3
Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings,
balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor
five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement :
1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
0.56
-
-
50.6.7.1
Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement
mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.
3.15
-
-
GENERAL ELECTRIFICATION
-
-
-
1.10.1
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated
copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch,
modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper
conductor single core cable etc as required.Group A
6
-
-
1.10.2
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated
copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch,
modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper
conductor single Core cable etc as required.Group B
3
-
-
od214930/2019_2020
Supply wiring light point as detailed above but without ceiling rose for batten point with fixing brass
batten/ angle holder including connection etc. as required.brGroup A
24
-
-
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate
switch box including connections but excluding modular plate etc. as required.
1
-
-
1.31
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess,
including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch,
connection etc. as required. (For light plugs to be used in non residentialbuildings).
3
-
-
1.32
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess,
including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular
switch, connection etc. as required.
3
-
-
90.4.1
Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required
1
-
-
1.27.1
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular
switches in recess etc as required.1 or 2 Module (75mmX75mm)
6
-
-
1.21.1
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/
recess including cutting the wall and making good the same in case of recessed conduit as required.20
mm
86
-
-
1.17.3
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
572
-
-
1.17.12
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
118
-
-
2.3.2
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,
on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8
way, Double door
1
-
-
2.10.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Single pole
6
-
-
2.12.1
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete
with connections, testing and commissioning etc. as required.40 amps
1
-
-
2.14.2
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent
circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB
complete with connections, testing and commissioning etc. as required.40 amps
1
-
-
90.4.5.2
Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using
standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC
insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended
original wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod ,
canopies, shackeles and blades and resistance type regulator working on 230V/240V single phase A/C
1
-
-
od214931/2019_2020
Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the
existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including
giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3core round
copper conductor flex wire conforming to relevant ISS
4
-
-
5.4
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding
masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.
with charcoal/ coke and salt as required.
1
-
-
Supply and installation of 20W LED tube
14
-
-
Supply of 9W LED bulb
1
-
-
Provisions for meter board and paneling
1
-
-
KSEB Charges
1
-
-
Supply of 15W LED bulb-
6
-
-
ELECTRICAL AND PLUMBING WORKS FOR CREMATORIUM MACHINERY
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements