Steel Industrials Kerala Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
₹ 2,950Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_SILK_665672_1Bid Award Id
ViewTender No
ASBU/4.02(42)/2023-24/1512Tender Authority
Steel Industrials Kerala Limited ViewPurchaser Address
-Website
http://https://steelindustrials.net/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
od185159/2023_2024
Fabrication and fixing of the Panel Board Stand with 2 legs made up of B class GIbrpipe 32mm dia
1.8mtr. length. 32 mm dia G.I pipe ( medium class)br
A. 32 mm dia. G.I. pipe (medium class) - 3.6 Metre B. MS Flat (Ref. MR6004) - 2 Kg
C. Welding Electrode 10 Guage - 6 Each
D. MS Bolts and Nuts (Ref. MR6007) - 0.25 Kg
E. Stone aggregate (single size) 20mm nominal size - 0.268 M3
F. Stone aggregate (single size) 10 mm nominal size - 0.088 M3
G. Coarse sand (Zone III) - 0.180 M3
H. Cement - 0.128 Tonne
I. Grey Paint ( Ref. MR7137 ) - 0.100 per litre
J. Labour Charges
29
-
-
... More
od185160/2023_2024
Supply of Meter Box made out of Sheet Moulding Compound (430 x 265 x 170 mm size) Surface
mounted or recess-in wall (Indoor/Outdoor Use) One piecebrmoulded SMC base and SMC door with
internal hinges. Knockout for wire entry, earthing bolt and earthing of the meter box.br
A. 2.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable - 5 Metre
B. SMC Meter Box 430 x 265 x 170 mm size - 1 Each
C. 63 A rating, 2 pole, 100 mA RCCB - 1 Each
D. 63A, HRC Fuse Base with HRC Fuse link - 1 Each
E. 63A, 2 Way neutral links mounted on DMC/SMC base - 1 Each
F. Supply and ProvPiding OBOR(SwitchinIgbrSurge/Lighting protection) for singlebrphase protectionbr - 1 Each
G. G.I Pipes 25mm dia (Ref. LMR 1547) - 1 Metre
H. Earth Wire (Ref. MR6044) - 0.15 Kg
I. Iron bolts and nuts of various sizes - 0.05 Kg
J. PVC pipe 32 mm outer dia 6Kgf/cm2 - 4 Metre
K. Earthing Compound - 4 Kg
L. Labour Charges
29
-
-
... More
od185161/2023_2024
Fabrication and fixing of the Meter Box. Stand with 1 leg made up of GI pipebr40mm dia 2.5mtr.
length.brbr
A. MS Flat (Ref. MR6004) - 2 Kg
B. MS Bolts and Nuts (Ref. MR6007) - 0.25 Kg
C. Stone aggregate (single size) 20mm nominal size - 0.268 M3
D. Stone aggregate (single size) 10 mm nominal size - 0.088 M3
E. Coarse sand (Zone III) - 0.18 M3
F. Cement - 0.128 Tonne
G. Grey Paint ( Ref. MR7137 ) - 0.10 Per Litre
H. G.I. pipes 40 mm dia (Ref. LMR 1549) - 2.5 Metre
I. Welding Electrode 10 Guage (Ref. MR7113) - 2 Each
J. Labour Charges
29
-
-
... More
od185164/2023_2024
Supply and fixing HRC fuse base of 20/32A using suitable nut and bolt, 32A 2-way neutral links mounted
on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable.
A. HRC fuse base of 20/32A using suitable nut and bolt - 1 Each
B. 32A 2-way neutral links mounted onDMC/SMC base - 1 Each
C. 2.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable - 3 Metre
D. Labour Charges
29
-
-
... More
2.14.2
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 amps
29
-
-
... More
2.10.3
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Double pole
58
-
-
... More
2.10.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Single pole
29
-
-
... More
2.12.1
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete
with connections, testing and commissioning etc. as required.40 amps
29
-
-
... More
90.6.5.11
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V
grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface /
recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq
mm
580
-
-
... More
5.3
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding
masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.
(but without charcoal/ coke and salt ) as required.
58
-
-
... More
90.16.4.2
Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using
clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps
not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3
mm GI strip
377
-
-
... More
90.16.1.3
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required3.15 mm copper conductor ( 10 SWG)
464
-
-
... More
90.16.5.3
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.3.15 mm (10 SWG)
232
-
-
... More
90.12.5.3
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of
1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as
required.2 core 10 sq mm
232
-
-
... More
90.12.9.2
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of
HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all
required accessories in ground in the existing trench50/38 mm or nearest size
290
-
-
... More
9.1.2
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.2 X 10 sq. mm (19mm)
87
-
-
... More
od185165/2023_2024
Charges for KSEB connection including all laison works (Actual Amount paid on production of receipt).
29
-
-
... More
2.6.1
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas
(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated
earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of
soil
40.6
-
-
... More
4.1.8
Providing and laying in position cement concrete of specified grade excluding the cost of centering and
shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40
nominal size)
2.9
-
-
... More
5.9.1
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of
columns, etc for mass concrete
105.56
-
-
... More
5.22.6
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and
binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
811.19
-
-
... More
5.1.2
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of
centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse
sand :3 graded stone aggregate 20 mm nominal size
15.12
-
-
... More
13.1.1
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand
27.91
-
-
... More
2.25
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not
exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m
and lift up to 1.5 m.
25.21
-
-
... More
od185162/2023_2024
Supply and fixing of name board with angles , flats,square pipe, ACP sheet including nut and bolts, 4 no.s
per mast ,2sqmm in area
29
-
-
... More
od185225/2023_2024
Fabrication supply conveyance and installation of Granite name board indicating the cost involved,
commencement date, completion date and inaguration date etc