Steel Industrials Kerala Limited Tender
... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 28,306Document Cost
₹ 2,950Tender Fee
Refer Documents
Summary
Supply And Installation Of 1nos. Of 8 Meterminimast With 6x180w Led Floodlights And Supply And Installation Of 2nos. Of 12meterhighmast With 6x200w Ledfloodlights At Various Places Of Nattikalac Thrissurdistrict 24-25 Mla-ads Of Sri Cc Mukundanmla
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_SILK_747744_1Tender No
SILK/GEW/SP/2024-25/44Tender Authority
Steel Industrials Kerala Limited ViewPurchaser Address
-Website
http://https://steelindustrials.net/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
2.6.1
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas
(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated
earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of
soil
1.4
-
-
... More
4.1.8
Providing and laying in position cement concrete of specified grade excluding the cost of centering and
shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40
nominal size)
0.1
-
-
... More
5.9.1
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of
columns, etc for mass concrete
3.64
-
-
... More
5.22.6
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and
binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
27.97
-
-
... More
5.1.2
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of
centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse
sand :3 graded stone aggregate 20 mm nominal size
0.52
-
-
... More
2.25
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not
exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m
and lift up to 1.5 m.
0.87
-
-
... More
Electrical Works
-
-
-
... More
90.15.1.1
Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet
70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm
suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage
suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4
nos existing RCC foundation and junction box etc, complete 8 Meters
1
-
-
... More
90.15.4.10
Installation, testing and commissioning of 180W LED Flood light output greater than
105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor
greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast
Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98,
RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly
accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced
mentioning chip manufacturer)
6
-
-
... More
90.14.1.2
Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust
and vermin proof, cubicle type MV panel board comprising of the following components/ devices &
complying to IS 8623.brFabrication of fully partitioned, dust and vermin proof enclosure for panel
assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design
and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear
compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs
for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar
chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required.
CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the
fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for
panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using
1.6mm CRCA sheet, powder coated (excluding base frame)
1.5
-
-
... More
90.14.3.2
Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding
suitable for 1.60/ 2.00 mm sheet
2
-
-
... More
90.14.5
Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel
board
10
-
-
... More
od212715/2024_2025
Supply and fixing of 1 no. of 25 A 2 Pole AC 1 rated power contractor ,25 A connector , 1 nos of Digital
timer,suitable copper socket, 2.5 Sq.mm ISI marked FRLS PVC insulated single core copper conductor
cable, 1.5 sq.mm ISI marked FRLS PVC insulated single core copper conductor cable,
1
-
-
... More
od212716/2024_2025
Supply and fixing of Surge protector device of IP 20,Mounting type: Screw,Voltage protection
level(UP),Nominal voltage:230V ,UOC:10KV,L-N:7 KV,L-PE:7 KV,N-PE:7 KV,Nominal discharge current
(8/20):10 KA,Total discharge current (8/20):60 KA, Response time :35 ns, Ta: -10-55.
1
-
-
... More
od212717/2024_2025
Supply and fixing HRC fuse base of 20/32 A using suitable nut and bolt, 32 A 2- way neutral links
mounted on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper
conductor cable.
1
-
-
... More
2.14.2
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 amps
1
-
-
... More
2.12.1
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete
with connections, testing and commissioning etc. as required.40 amps
1
-
-
... More
2.10.3
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Double pole
1
-
-
... More
2.10.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Single pole
1
-
-
... More
90.6.5.11
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V
grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface /
recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq
mm
10
-
-
... More
90.6.5.12
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V
grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface /
recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq
mm
8
-
-
... More
5.3
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding
masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.
(but without charcoal/ coke and salt ) as required.
2
-
-
... More
90.16.4.2
Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using
clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps
not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3
mm GI strip
8
-
-
... More
90.16.1.3
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required3.15 mm copper conductor ( 10 SWG)
2
-
-
... More
90.16.5.3
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.3.15 mm (10 SWG)
5
-
-
... More
90.12.37.5
Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV
grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the
trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 4
sq mm
8
-
-
... More
90.12.9.2
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of
HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all
required accessories in ground in the existing trench50/38 mm or nearest size
8
-
-
... More
od212718/2024_2025
Supplying and making end termination with brass compression gland and aluminium lugs for
brfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV
brgrade as required. 3 X 4 sq. mm
2
-
-
... More
od212719/2024_2025
Charges for KSEB connections and PWD road cutting charges including all laison works ( Actual amount
paid on production of receipt).
1
-
-
... More
Miscellenous Works
-
-
-
... More
od212713/2024_2025
Supply and fixing of name board with angles, flats, square pipe, ACP sheet including nut and bolts. 4 nos
per mast, 2Sqm in area.
1
-
-
... More
od212714/2024_2025
Fabrication supply conveyance and installation of Granite name board indicating the cost involved,
commencement date, completion date and inaguration date etc.
1
-
-
... More
Supply and installation of 2 Nos. of 12 Meter High mast with 6X200W LED flood lights at various places of Nattika LAC Thrissur District. 2024- 25 MLA-ADS of Sri. C.C Mukundan MLA.
-
-
-
... More
Civil and Electrical works for Mast
-
-
-
... More
Civil Works
-
-
-
... More
2.6.1
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas
(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated
earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of
soil
5.47
-
-
... More
4.1.8
Providing and laying in position cement concrete of specified grade excluding the cost of centering and
shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40
nominal size)
0.42
-
-
... More
5.9.1
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of
columns, etc for mass concrete
10.68
-
-
... More
5.22.6
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and
binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
196.96
-
-
... More
5.1.2
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of
centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse
sand :3 graded stone aggregate 20 mm nominal size
2.48
-
-
... More
2.25
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not
exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m
and lift up to 1.5 m.
2.96
-
-
... More
Electrical Works
-
-
-
... More
90.15.2.3
Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/two
sections of hot dip galvanised GI sheet 100mm top diameter, 360mm bottom diameter thickness 3mm
mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system
with steel wire rope 5mm dia double drum winching system w and including round arm galvanized
luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box and
lighting spikes with single phase operation power tool installed inside the base compartment including
connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc, complete 12
Meters
2
-
-
... More
90.15.4.11
Installation, testing and commissioning of 200W LED Flood light output greater than
105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor
greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast
Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98,
RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly
accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced
mentioning chip manufacturer)
12
-
-
... More
od212635/2024_2025
Supply and installation of twin unit aviation LED obstruction light with stand yellow- painted die-cast
aluminum alloy housing, red coloured poly carbonate dome and BC/ EC lamp holders suitable for LED
lamp.
2
-
-
... More
90.14.1.2
Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust
and vermin proof, cubicle type MV panel board comprising of the following components/ devices &
complying to IS 8623.brFabrication of fully partitioned, dust and vermin proof enclosure for panel
assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design
and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear
compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs
for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar
chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required.
CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the
fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for
panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using
1.6mm CRCA sheet, powder coated (excluding base frame)
4
-
-
... More
90.14.3.2
Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding
suitable for 1.60/ 2.00 mm sheet
4
-
-
... More
od212636/2024_2025
Supply and fixing of 1 no. of 25 A 4 Pole AC 1 rated power contractor ,25 A connector , 1 nos of Digital
timer,suitable copper socket, 2.5 Sq.mm ISI marked FRLS PVC insulated single core copper conductor
cable, 1.5 sq.mm ISI marked FRLS PVC insulated single core copper conductor cable
2
-
-
... More
od212637/2024_2025
Supply Conveyance and Installation of Surge protector device of IP 20,Mounting type: Screw,Voltage
protection level(UP),Nominal voltage:230V ,UOC:10KV,L-N:7 KV,L-PE:7 KV,N-PE:7 KV,Nominal
discharge current (8/20):10 KA,Total discharge current (8/20):60 KA, Response time :35 ns, Ta: -10-55.
2
-
-
... More
od212638/2024_2025
Supply and fixing of 2 nos.of 25A 3 Pole AC 1 rated power contactor, Selector switch for motor control,
supply and fixing flush head push button NO-NC, 1.5 sq. mm ISI marked FRLS PVC insulated single core
copper conductor cable and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor
cable.
2
-
-
... More
od212639/2024_2025
Supply and fixing HRC fuse base of 20/32 A using suitable nut and bolt, 32 A 2- way neutral links
mounted on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper
conductor cable.
6
-
-
... More
90.14.5
Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel
board
20
-
-
... More
2.10.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Single pole
2
-
-
... More
2.10.5
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Triple pole and neutral
2
-
-
... More
2.13.1
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 amps
2
-
-
... More
2.15.2
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 ampsre 1.50 sq
mm
2
-
-
... More
90.6.5.11
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface /
recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq
mm
36
-
-
... More
90.6.5.19
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V
grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface /
recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq
mm
24
-
-
... More
5.3
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding
masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.
(but without charcoal/ coke and salt ) as required.
4
-
-
... More
90.16.4.2
Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using
clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps
not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3
mm GI strip
16
-
-
... More
90.16.1.3
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required3.15 mm copper conductor ( 10 SWG)
4
-
-
... More
90.16.5.3
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.3.15 mm (10 SWG)
10
-
-
... More
90.12.1.12
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of
1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling
the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core
4 sq mm
16
-
-
... More
90.12.1.38
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of
1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling
the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core
4 sq mm
16
-
-
... More
90.12.9.2
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of
HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all
required accessories in ground in the existing trench50/38 mm or nearest size
20
-
-
... More
9.1.32
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.4 X 10 sq. mm (25mm)
4
-
-
... More
od212640/2024_2025
Charges for KSEB connections and PWD road cutting charges including all laison works ( Actual amount
paid on production of receipt)
2
-
-
... More
Miscellenous Works
-
-
-
... More
od212633/2024_2025
Supply and fixing of name board with angles, flats, square pipe, ACP sheet including nut and bolts. 4 nos
per mast, 2Sqm in area.
2
-
-
... More
od212634/2024_2025
Fabrication supply conveyance and installation of Granite name board indicating the cost involved,
commencement date, completion date and inaguration date etc.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%