Sports Kerala Foundation Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Sports Kerala Foundation - SKF Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date9 Mar 2024
Closing Date18 Mar 2024
Tender Amount₹ 1,01,39,599 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
15.57 : Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge

45

-

-

... More
od195067/2023_2024 : Providing and fixing anodised aluminium louvers (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design or pattern, with approved standard section and fixed to the existing window frame with CP brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised alumnium standard section around the opening, all complete as per requirement and direction of engineer- in-charge. (only weight of grill to be measured for payment).

225

-

-

... More
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

403.2

-

-

... More
15.28.1 : Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :G.S. Sheet

720

-

-

... More
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

720

-

-

... More
24.2 : Providing and fixing double scaffolding system (Cup lock type ) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40 mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube chakkus, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and / or pointing and / or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-Charge. Note: - ( 1) The evaluational area of the scaffolding shall be measured for payment purpose, (2) The payment will be made once only for execution of all items of such works.

18

-

-

... More
Electrification work

-

-

-

... More
od204433/2023_2024 : Supply and installation of 125A, 4 pole On-Load Change Over Switches with SS Enclosure and others accessories as required.

1

-

-

... More
90.12.7.45 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

25

-

-

... More
1.10.1 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A

5

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

35

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

24

-

-

... More
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

10

-

-

... More
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

3

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

8

-

-

... More
90.16.1.4 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required

62.5

-

-

... More
90.15.4.3 : Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

5

-

-

... More
90.15.4.7 : Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

12

-

-

... More
90.12.7.1 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

75

-

-

... More
90.6.5.5 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.

45

-

-

... More
90.12.7.38 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

48

-

-

... More
od204447/2023_2024 : Supply and installation of pre-wired 20W LED batten fitting complete with all accessories and tube etc directly on ceiling/wall, including connection with 1.5sqmm FRLS PVC insulated,copper conductor single core cable and earthing<br>etc as required.Make: Phillips, Crompton greaves, Bajaj, Lucker or Approved by<br>engineering in charge

10

-

-

... More
od204448/2023_2024 : Supply and fixing of syntex box (150mm x 150 mmx100mm) including connector ,MCB rails and neutral links for giving connection with accessories complete as required

5

-

-

... More
od204449/2023_2024 : Engaging Electrician as per the direction of Engineer in Charge.

5

-

-

... More
od331561/2023_2024 : Supply and Installation of Heavy duty exhaust fan of 300 mm / 12 Inch Sweep Heavy Duty Motor with Double Ball Bearings and Dynamically Balanced Blade for Vibration Free Rotation, Specially Designed Guard to Make it Bird & Foreign Matter Proof Long life powder coating for anti-corrosion Metallic Finish. Crompton, RR, V Guard or make premium brand

8

-

-

... More
Fire fighting

-

-

-

... More
od204432/2023_2024 : Supply, installation, testing and commissioning of gun metal fire hydrant valve single head oblique type with 63mm instantaneous outlets with female socket for hose connection and inlet side with flange suitable for 80mm pipe flange,valve conforming to IS:5290 complete with blank cap,chain, GI nuts, bolts, gasket etc as per technical specification.

7

-

-

... More
od204434/2023_2024 : Supply of Controlled Percolated Hose conforming to IS: 636, 63mm dia, 15 Mtrs length with Aluminium 63 mm pair of male and female couplings With ISI Mark etc

14

-

-

... More
od204435/2023_2024 : Supply of Aluminium Branch Pipe, 63mm female instantaneous inlet, male threaded outlet, With ISI Mark complete with hexagonal base nozzle.

7

-

-

... More
od204436/2023_2024 : Supply and installation of 12v 180Ah battery

1

-

-

... More
od204437/2023_2024 : Supply of Sprinkler, 68 degree Celsius, pendent, normal response, standard coverage, chrome finish for spare.

6

-

-

... More
od204438/2023_2024 : Supply of Addressable heat detector for spare.

2

-

-

... More
od204439/2023_2024 : Supply of Addressable manual pull station type for spare.

2

-

-

... More
od204440/2023_2024 : Supply and installation of 12v 42 Ah Battery

2

-

-

... More
od204441/2023_2024 : Refilling of existing Fire extinguishers

5

-

-

... More
od204442/2023_2024 : Supply and installation of charger for diesel engine pump controller, 12 Volts 10 Amps.

1

-

-

... More
od204443/2023_2024 : Supply and refilling of coolant for diesel engine driven pump

5

-

-

... More
od204444/2023_2024 : Supply and refilling of diesel for diesel engine driven pump

25

-

-

... More
od204445/2023_2024 : Replacement of ammeter in main pump control panel and diesel engine controller.

2

-

-

... More
od204446/2023_2024 : Charges for removal and re-installation of Alarm check valve upside down for proper working including piping works.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.