Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Sports Kerala Foundation - SKF Tender

Works
Civil And Construction
Building Construction
Consultancy Services
Civil And Architectural Services
Eprocure
Opening Date22 Jan 2024
Closing Date1 Feb 2024
Tender Amount₹ 82,40,517 
Notes
Download

Costs

Summary

Development Of Sports Infrastructure Facilities At Kazhakuttam Lac- Ground At Govt Hss, Kulathoor

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge

207.9

-

-

... More
od189953/2023_2024 : Design, supply, fabrication and erecting of Pre Engineered steel structure for indoor court of size 31.5mx22.0mx10m or nearest, including roof members. The rate includes cost of steel sections, fasteners, ties, bracings, Z-section purlins, charges for design, fabrication, erection, supervision, applying a priming coat and two coats of epoxy paint over the steel surface. The structure shall have an eve projection up to 75 cm on all sides as provided in the drawing where as the work will be measured based on the plinth area of the building. Basic elements like dimensions of the building, number and spacing of columns shall remain unchanged in the detailed structural design.

693

-

-

... More
od305682/2023_2024 : Providing and fixing 30cm wide UPVC rain water Gutter pipe/pathy (White,brick red,royal blue,grey) of overall size 45 cm in rectangular section with clamp/brackets @ a spacing 1200mm and 2x12 gauge screws mm, necessary bolts, nuts and including making necessary connections with rain water pipes complete.<br>0.63 mm thick with zinc coating not less than 275 gm/ m2

69

-

-

... More
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

897

-

-

... More
od304726/2023_2024 : Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:<br>Ridges profile (500-600 mm)

34.5

-

-

... More
12.41.2 : Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter

120

-

-

... More
12.42.5.2 : Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionBend 87.5sup0/sup110 mm bend

36

-

-

... More
od304860/2023_2024 : SKF_OD 7/2022-2023 Supplying and stacking for measurement sieved red earth at site including royalty and carriage upto 5 k.m. lead, all labour charges for stacking, loading and unloading etc complete.( Based on CPWD 30.2.2 & 30.2.4.3)

83.16

-

-

... More
od304861/2023_2024 : SKF_OD 4/2022-2023 Supplying and stacking for measurement Sieved Jamuna Sand at site including cost of sand and carriage upto 5 k.m. lead all labour charges for stacking, loading and unloading etc complete.( Based on CPWD 30.2.2 & 30.2.4.3)

20.79

-

-

... More
od304862/2023_2024 : SKF_OD 2/2022-2023 Mixing earth and jamuna sand in the required proportion specified or directed by the Officer-in-charge including all cost of labour charges,hire charges of machineries etc complete.(Based on CPWD 30.2.9)

103.95

-

-

... More
od304863/2023_2024 : SKF_OD 3/2022-2023 Spreading of earth and jamuna sand in required thickness as per direction of officer-in-charge including all cost of labour charges, hire charges of machineries etc complete. (cost of earth and jamuna sand to be paid separately).( Based on CPWD 30.2.8)

103.95

-

-

... More
od304864/2023_2024 : SKF_OD 10/2022-2023 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity with road roller including making good the undulations etc. including all cost of labour, hire charges, fuel, oil, etc. complete.( Based on CPWD 16.1)

693

-

-

... More
Indoor Foundation and Drainage (CPWD)

-

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

195.67

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

31.2

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

93.6

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

19.8

-

-

... More
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

59.59

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

218.48

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

150

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

107

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

5784.86

-

-

... More
od305548/2023_2024 : Lifting, conveying and fixing the newly casted RCC covering slabs of any thickness on top of drain in position including all labour charges and miscellaneous expenses etc complete. ( Based on MoRTH 55.25)

5.25

-

-

... More
50.6.1.8 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etc complete

18.45

-

-

... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

273.99

-

-

... More
13.48.1 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm

273.99

-

-

... More
13.88 : Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete

744.5

-

-

... More
13.112.1 : Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shadeOld work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface

744.5

-

-

... More
15.2.1 : Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

1.13

-

-

... More
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar

2.25

-

-

... More
10.1 : Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

21.78

-

-

... More
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

1

-

-

... More
od306220/2023_2024 : Providing and laying of interlock concrete block pavements having thickness 60mm (M35) as per drawings and technical specification clause 1504 confirming to IS 15658 and laid in required colour and pattern over and including 50mm thick compacted bed of 6 mm metal including edge concreting for 300mm width and 150mm depth with CC M35( @ 0.045 m3/m)

230

-

-

... More
Electrical works

-

-

-

... More
90.11.1.11 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required. 6 way (8+18) - three phase double cover (IP 42/43)

1

-

-

... More
90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required. 6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

6

-

-

... More
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

-

-

... More
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

1

-

-

... More
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

-

-

... More
2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

1

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

24

-

-

... More
90.12.7.2 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 2 core 6 sq mm with factory made clamp

77

-

-

... More
90.12.7.39 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 6 sq mm with factory made clamp

225

-

-

... More
90.12.7.42 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 25 sq mm with factory made clamp

18

-

-

... More
90.12.5.42 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 4 core 25 sq mm

35

-

-

... More
90.6.5.11 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 3 core 1.50 sq mm

117

-

-

... More
90.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 10 sq mm with factory made clamp

10

-

-

... More
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required.3.15mm copper conductor ( 10 SWG)

270

-

-

... More
od189861/2023_2024 : Supply and Installation of 200W Sports Flood light with low glare LED Floodlight luminaire with system power [200W ± 5%], color temperature (5700K ± 355K), made of a single piece Pressure die cast aluminum (PDC) housing with separate driver and optical compartment separated by natural air gap for Thermal isolation & Powder coated by Corrosion resistant Nano coating technology. The fixture is provided with a injection moulded UV stabilized Polycarbonate cluster Lens optics with beam angle 60° beam angle for optimum light spread.<br>Integral encapsulated high efficiency electronic driver having a Aluminium extrusion construction with rated voltage of 140-270V, power factor > 0.95, THD < 5%, IP66 protection, Inbuilt surge protection of 10 KV, has mis wiring, Over voltage, Short circuit, Reverse Polarity protection, Input over Voltage cut-off at 320V with Auto Recovery feature. Also upgraded with integral external IP67 protected SPD of 20KV/10KA surge protection & Line-Line 440VAC Withstand capacity up to 4Hrs. <br>Luminaire has a Ingress protection of IP66 and Impact Resistance of IK08. <br>The luminaire lumen output > 150 LPW & system lumen package of >30000 Lm , CRI of 70 . The LEDs used have a life of 50000 burning hrs Lumen maintenance as per L70 and suitable for Cradle mount application.<br>Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge: IEC 61000-4-5, EMC: EN 55015, IES, LM 79, LM 80, & TTC certificates will be provided from NABL accredited lab certification: CE Certified, ROHS compliant, BIS Certification for Luminaires & Drivers. Luminaire should have a system warranty for 5 years.

18

-

-

... More
4.6.1 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width X 50 mm depth X 1.6 mm thickness Details of cost for 30 metres

105

-

-

... More
od305478/2023_2024 : SKFOD_ Supply and fixing SINTEX Box (150mmx150mmx100mm) or nearest size including MCB Rail or Connectors for giving connections including all accessories complete as required

12

-

-

... More
od305457/2023_2024 : SKF_OD - Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, with providing masonry enclosure with cover plate / FRP Earth Pit Chamber. ( but without charcoal/ coke and salt ) etc as required.<br>

2

-

-

... More
9.1.1 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)

20

-

-

... More
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)

2

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

2

-

-

... More
90.12.5.38 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 4 core 4 sq mm

80

-

-

... More
90.12.10.2 : Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation 50/38 mm or nearest size

115

-

-

... More
90.15.3.3 : Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 6 Meters

2

-

-

... More
90.15.4.2 : Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

2

-

-

... More
90.16.1.2 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required. 2.65 mm copper conductor (12 SWG)

80

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.